Pacemaker DddPOCKET-RCTNCT02931760
Placement Of Cardiac PacemaKer Trial (POCKET)-RCT
A study testing subcutaneous pacemaker and intramuscular pacemaker in people with Pacemaker Ddd, run by Region Gävleborg at 1 site in Sweden.
Trial summary
Aim: To compare patient satisfaction with intramuscular placement of a pacemaker pocket to subcutaneous placement. Patients will be randomized (approximately half i each group) to receive the pacemaker device either subcutaneously (current practise) or intramuscular) Read more about this study
- Who is it for?
- Any age
- Conditions the study is for
- Pacemaker Ddd
- What is being tested?
- subcutaneous pacemaker and intramuscular pacemaker
- Type of treatment
- Injection or infusion, Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 200 participants
- Where
- 1 siteSweden
- Study dates
- Oct 2016to Jun 2019
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages Any age
- All sexes
- No healthy volunteers
- Child, Adult, Older adult
Who may be able to join
- Indication of a bradycardia pacemaker (DDDR, VVIR).
Who cannot join
- CRTP, CRTD, ICD.
- Very skinny patient deemed as such by implanting physician to clearly benefit from intramuscular implant.
Trial locations and contacts
1 site in 1 country.
Sweden1 site, 1 recruiting
- Recruiting
Region Gavleborg
Gävle, Gävle, 80325
Peter Magnusson, M.D., +46705089407, peter.magnusson@regiongavleborg.se
Leo Wennstrom, M.D., +4626154000, leo.wennstrom@regiongavleborg.se
About this study
Aim: To compare patient satisfaction with intramuscular placement of a pacemaker pocket to subcutaneous placement.
Patients will be randomized (approximately half i each group) to receive the pacemaker device either subcutaneously (current practise) or intramuscular)
Read the detailed description
Background: Implantation of a cardiac pacemaker may be indicated in patients with a significant bradycardia according to current guidelines.1 Annually, around 691 pacemakers per million inhabitants are implanted in Sweden.2 A pacemaker system consist of one or two leads connected to a device that is implanted beneath the collarbone.3,4 Vessel access is typically on the left side through the cephalic, axillary or subclavian vein. The pacemaker is inserted into a pocket. Routinely this pocket is just above the pectoral fascia (subcutaneously) or sometimes in skinny patients with a small amount of subcutaneous fat between the pectoral muscular layer (intramuscular). Even though technical developments have diminished the size of pacemakers markedly over time, complications due to superficial implants still do occur.5,6 Occasionally the device erode the skin and a complete extraction of the system is necessary. More frequently patients complain about the device being too superficial which sometimes require surgical repositioning of the device.5,6 The device may create discomfort, pain, and unsightly.5,6 The lateral corner of the device may disturb the shoulder movement, sleep and the leads can be turned within the pocket (Twiddler's syndrome). Minor branches from the supraclavicular nerves may result in discomfort. When vessels from the subcutaneous adipose tissue are distorted, extensive bruising may be bothersome and a large hematoma is a known risk of infection. The perfusion in the operation area is diminished and the amount of fat over device may be reduced to an extent that was unexpected at first implant. The change of device due to battery depletion can result in even less surrounding tissue. An alternative approach is an intramuscular placement of the device.7,8 This has been advocated by Kistler et al based on personal experience but there are neither systematic observational studies nor randomized controlled studies to support this approach.6 To the knowledge of the investigators no randomized controlled trial have addressed the question about the optimal placement of a bradycardia pacemaker.
Aim: To compare patient satisfaction with intramuscular placement of a pacemaker pocket to subcutaneous placement.
Research questions: Primary outcome: Is there a different in patient overall satisfaction (on a Visual Analog Scale (VAS)-scale between 0-10) with the pocket between patients with intramuscular placement of a pacemaker pocket and patients with subcutaneous placement at 24 months after implant? Secondary outcomes: Complications (revision of pocket, dislodgement, hematoma requiring surgery, infection (local/systemic). Patient reported satisfaction at 1, 12, 24 months (overall satisfaction, pain, discomfort, degree of unsightly look, movement problems due to device, and sleep problems due to device). Pacemaker nurse judgement of unsightly look of the pacemaker pocket (month 1, 12, and 24). Picture of pocket (1, 12, 24 months) judged by an experienced implanting physician who is blinded to the group allocation and has not operated on the patient.
Method: Power analysis: the investigators performed a power analysis based on expectations and clinical experience of the research group. Figure 1 shows two hypothetical truncated lognormal distributions of patient overall satisfaction with the pacemaker, where median overall satisfaction of the intramuscular and the subcutaneous group are assumed to be 2.4 and 4, respectively. Monte Carlo-simulations from these distributions showed that a total of 200 patients, 100 in each arm, would yield a statistical power of 90% for Mann-Whitney U-test at a significance level of 0.05.
In total, 200 consecutive patients with indication of are expected to be randomized in the study (100 patients in each arm, intramuscular vs subcutaneously). In Region Gavleborg , the annual primary implant volume of bradycardia pacemakers is approximately 220.
Figure 1. Assumed distributions of patient overall satisfaction in the power analysis, as measured by an visual analogue scale where 0 means "very satisfied" and 10 means "very dissatisfied". The intramuscular group is assumed to follow a lognormal distribution with mean 1.5 and standard deviation of 1, on the logarithmic scale. The subcutaneous patients are assumed to follow a lognormal distribution with mean 1.5 and standard deviation of 1, on the logarithmic scale.
Randomization: At the time of implant 1:1 randomization (100 patients in each group) to either subcutaneous (usual care) or intramuscular implant, in blocks with random block sizes. The randomization is performed by a statistician with no insight in the ongoing clinical work and patients' group allocation is revealed for implanting physician by the assistant nurse at the start of the surgical procedure. Randomization procedure: stratification (age strata: ≤65 years and >65 years) and sex (female, male); totally 4 strata). Consecutive group allocations will be stored in sealed opaque envelopes that will be opened at the time of starting the implant procedure.
Inclusion: Indication of a bradycardia pacemaker (DDDR, VVIR). Exclusion: Cardiac Resynchronisation Therapy Pacemaker (CRTP), Cardiac Resynchronisation Therapy Defibrillator (CRTD), implantable cardioverter defibrillator (ICD). Very skinny patient deemed as such by implanting physician to clearly benefit from intramuscular implant.
Surgical procedure: Standard procedure and vascular access by each operator's preference. Blunt dissection of the pocket.
Statistical methods: For comparisons between groups: Mann-Whitney U-test. For test of changes in VAS-estimations between 1, 12, and 24 months: pair-wise Wilcoxon signed-rank test.
Informed consent: Written and oral information by nurse/physician before implant.
Ethical approval: Approved by Uppsala Regional Committee. Clinical Trial Registration: Registration before start of study.
Variables:
Clinical variables: age, sex, coronary artery disease, open-heart surgery, diabetes, kidney disease Pacemaker system: (VVIR, DDDR), brand, model (lead(s) and device. Vascular access: (cephalic, axillary, subclavian vein), fluro-time, procedure time Periprocedural analgetics (dosage): alfentanil, morphine, diazepam, paracetamol Pre och post-operative anticoagulant medication (dosage and withdrawal with respect to procedure: acetylic acid, clopidogrel, ticagrelor, dual oral anticoagulants, warfarin, low-molecular weight heparin) Preoperative current medication: (psychoactive drugs, betablockers, corticosteroids, inflammatory modulating drugs Outcome measurements: Patient satisfaction (overall, chronic pain, discomfort, degree of unsightly look, movement disorder due to device, sleep problems due to device) scale 0-10 (10 worst) Paper questionnaire at 1,12,and 24 months. Patient knowledge if device was intramuscular or subcutaneously implanted at 24 months.
Pacemaker nurse judgement: unsightly look (0-10, 10 worst). Physician evaluation (blinded to the patient and not operator in the study): photo of pocket (1, 12, 24 months) scale 0-10 (10 worst).
Complications requiring surgery: pocket revision, dislodgment, hematoma requiring surgery, infection (local, systemic), pneumothorax, pericardial effusion requiring drainage, other.
Clinical perspectives: The surgical approach to the pacemaker pocket needs to be evaluated. The optimal approach including patient reported outcomes may result in more long-term satisfaction and may reduce the need for pocket revisions.
- Conditions
- Pacemaker Ddd
- Being tested
- subcutaneous pacemaker, intramuscular pacemaker
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
subcutaneous pacemakerDevice
During implant of a pacemaker the device is either implanted subcutaneously or intramuscular
intramuscular pacemakerDevice
During implant of a pacemaker the device is either implanted subcutaneously or intramuscular
| Study group | Role | What they receive |
|---|---|---|
| subcutaneous pacemaker | Active comparator | The patients who are randomized to receive a subcutaneously implanted pacemaker Receives: Device: subcutaneous pacemaker |
| intramuscular pacemaker | Active comparator | The patients who are randomized to receive an intramuscular implanted pacemaker Receives: Device: intramuscular pacemaker |
What is being measured
The primary outcome is the main question the study is designed to answer.
patient overall satisfaction
Is there a different in patient overall satisfaction (on a VAS-scale between 0-10) with the pocket between patients with intramuscular placement of a pacemaker pocket and patients with subcutaneous placement at 24 months after implant?
Measured: 24 months
Secondary outcomes (8)
complications due to pacemaker procedure
Complications (revision of pocket, dislodgement, hematoma requiring surgery, infection (local/systemic). Measurement: number of each event (n)
Measured: 24 months
pain problems due to pacemaker device
Patient reported pain at 1, 12 and 24 months on a VAS-scale 0-10.
Measured: 24 months
discomfort due to pacemaker device
Patient reported discomfort at 1, 12, 24 months on a VAS-scale 0-10.
Measured: 24 months
Patient own judgement of degree of unsightly look due to pacemaker device
Patient reported satisfaction at 1, 12, 24 months on a VAS-scale 0-10.
Measured: 24 months
movement problems due to device
Patient reported satisfaction at 1, 12, 24 months on a VAS-scale 0-10.
Measured: 24 months
sleep problems due to device
Patient reported satisfaction at 1, 12, 24 months on a VAS-scale 0-10.
Measured: 24 months
Pacemaker nurse judgement of unsightly look of the pacemaker pocket
Pacemaker nurse judgement of unsightly look of the pacemaker pocket (month 1, 12, and 24) on a VAS-scale 0-10.
Measured: 24 months
Picture of pocket
Picture of pocket (1, 12, 24 months) judged by an experienced implanting physician who is blinded to the group allocation and has not operated on the patient on a VAS-scale 0-10.
Measured: 24 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted13 Oct 2016 (estimated)
- Study startOct 2016
- Primary completionDec 2017 (estimated)
- Study completionJun 2019 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (7)Papers the sponsor has linked to this study.
- Other trials for Pacemaker DddStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind
- Who is masked
- Participant
- Enrolment
- 200 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Region Gävleborg
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Peter Magnusson, Region Gävleborg
- Investigators
- Per Liv, Ph.D, Principal investigator, Centre for Research and Development Gavleborg/Uppsala University
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT02931760
- Sponsor's protocol ID
- 2016371
- Acronym
- POCKET-RCT
- Status last verified
- Oct 2016
- First submitted
- 1 Oct 2016
- Last updated
- 13 Oct 2016
- Results posted
- No
- Data monitoring committee
- No
- Individual data sharing
- Yes: IPD will be available (without identification of each individual) upon request by the journal (i.e Supplement file)
Publications
Brignole M, Auricchio A, Baron-Esquivias G, Bordachar P, Boriani G, Breithardt OA, Cleland J, Deharo JC, Delgado V, Elliott PM, Gorenek B, Israel CW, Leclercq C, Linde C, Mont L, Padeletti L, Sutton R, Vardas PE; ESC Committee for Practice Guidelines (CPG); Zamorano JL, Achenbach S, Baumgartner H, Bax JJ, Bueno H, Dean V, Deaton C, Erol C, Fagard R, Ferrari R, Hasdai D, Hoes AW, Kirchhof P, Knuuti J, Kolh P, Lancellotti P, Linhart A, Nihoyannopoulos P, Piepoli MF, Ponikowski P, Sirnes PA, Tamargo JL, Tendera M, Torbicki A, Wijns W, Windecker S; Document Reviewers; Kirchhof P, Blomstrom-Lundqvist C, Badano LP, Aliyev F, Bansch D, Baumgartner H, Bsata W, Buser P, Charron P, Daubert JC, Dobreanu D, Faerestrand S, Hasdai D, Hoes AW, Le Heuzey JY, Mavrakis H, McDonagh T, Merino JL, Nawar MM, Nielsen JC, Pieske B, Poposka L, Ruschitzka F, Tendera M, Van Gelder IC, Wilson CM. 2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy: the Task Force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). Eur Heart J. 2013 Aug;34(29):2281-329. doi: 10.1093/eurheartj/eht150. Epub 2013 Jun 24. No abstract available.
PubMed 23801822Gadler F, Valzania C, Linde C. Current use of implantable electrical devices in Sweden: data from the Swedish pacemaker and implantable cardioverter-defibrillator registry. Europace. 2015 Jan;17(1):69-77. doi: 10.1093/europace/euu233. Epub 2014 Oct 21.
PubMed 25336667Rajappan K. Permanent pacemaker implantation technique: part II. Heart. 2009 Feb;95(4):334-42. doi: 10.1136/hrt.2008.156372. No abstract available.
PubMed 19176569Rajappan K. Permanent pacemaker implantation technique: part I: arrhythmias. Heart. 2009 Mar;95(3):259-64. doi: 10.1136/hrt.2007.132753. No abstract available.
PubMed 19144885Kirkfeldt RE, Johansen JB, Nohr EA, Jorgensen OD, Nielsen JC. Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in Denmark. Eur Heart J. 2014 May;35(18):1186-94. doi: 10.1093/eurheartj/eht511. Epub 2013 Dec 17.
PubMed 24347317Kistler PM, Fynn SP, Mond HG, Eizenberg N. The subpectoral pacemaker implant: it isn't what it seems! Pacing Clin Electrophysiol. 2004 Mar;27(3):361-4. doi: 10.1111/j.1540-8159.2004.00442.x.
PubMed 15009864Gold MR, Peters RW, Johnson JW, Shorofsky SR. Complications associated with pectoral implantation of cardioverter defibrillators. World-Wide Jewel Investigators. Pacing Clin Electrophysiol. 1997 Jan;20(1 Pt 2):208-11. doi: 10.1111/j.1540-8159.1997.tb04844.x.
PubMed 9121991
Study at a glance
From the registry record, last updated by the sponsor on 13 Oct 2016. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Placement Of Cardiac PacemaKer Trial (POCKET)-RCT
- ClinicalTrials.gov ID
- NCT02931760
- Acronym / sponsor ID
- POCKET-RCT / 2016371
- Conditions
- Pacemaker Ddd
- Study type
- Interventional
- Recruitment status
- Unknown status
- Enrolment
- 200 participants (estimated)
- Lead sponsor
- Region GävleborgUniversity, hospital or other
- Study start
- Oct 2016
- Primary completion
- Dec 2017 (estimated)
- Study completion
- Jun 2019 (estimated)
- First posted
- 13 Oct 2016 (estimated)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Aim: To compare patient satisfaction with intramuscular placement of a pacemaker pocket to subcutaneous placement.
Patients will be randomized (approximately half i each group) to receive the pacemaker device either subcutaneously (current practise) or intramuscular)
Detailed description
Background: Implantation of a cardiac pacemaker may be indicated in patients with a significant bradycardia according to current guidelines.1 Annually, around 691 pacemakers per million inhabitants are implanted in Sweden.2 A pacemaker system consist of one or two leads connected to a device that is implanted beneath the collarbone.3,4 Vessel access is typically on the left side through the cephalic, axillary or subclavian vein. The pacemaker is inserted into a pocket. Routinely this pocket is just above the pectoral fascia (subcutaneously) or sometimes in skinny patients with a small amount of subcutaneous fat between the pectoral muscular layer (intramuscular). Even though technical developments have diminished the size of pacemakers markedly over time, complications due to superficial implants still do occur.5,6 Occasionally the device erode the skin and a complete extraction of the system is necessary. More frequently patients complain about the device being too superficial which sometimes require surgical repositioning of the device.5,6 The device may create discomfort, pain, and unsightly.5,6 The lateral corner of the device may disturb the shoulder movement, sleep and the leads can be turned within the pocket (Twiddler's syndrome). Minor branches from the supraclavicular nerves may result in discomfort. When vessels from the subcutaneous adipose tissue are distorted, extensive bruising may be bothersome and a large hematoma is a known risk of infection. The perfusion in the operation area is diminished and the amount of fat over device may be reduced to an extent that was unexpected at first implant. The change of device due to battery depletion can result in even less surrounding tissue. An alternative approach is an intramuscular placement of the device.7,8 This has been advocated by Kistler et al based on personal experience but there are neither systematic observational studies nor randomized controlled studies to support this approach.6 To the knowledge of the investigators no randomized controlled trial have addressed the question about the optimal placement of a bradycardia pacemaker.
Aim: To compare patient satisfaction with intramuscular placement of a pacemaker pocket to subcutaneous placement.
Research questions: Primary outcome: Is there a different in patient overall satisfaction (on a Visual Analog Scale (VAS)-scale between 0-10) with the pocket between patients with intramuscular placement of a pacemaker pocket and patients with subcutaneous placement at 24 months after implant? Secondary outcomes: Complications (revision of pocket, dislodgement, hematoma requiring surgery, infection (local/systemic). Patient reported satisfaction at 1, 12, 24 months (overall satisfaction, pain, discomfort, degree of unsightly look, movement problems due to device, and sleep problems due to device). Pacemaker nurse judgement of unsightly look of the pacemaker pocket (month 1, 12, and 24). Picture of pocket (1, 12, 24 months) judged by an experienced implanting physician who is blinded to the group allocation and has not operated on the patient.
Method: Power analysis: the investigators performed a power analysis based on expectations and clinical experience of the research group. Figure 1 shows two hypothetical truncated lognormal distributions of patient overall satisfaction with the pacemaker, where median overall satisfaction of the intramuscular and the subcutaneous group are assumed to be 2.4 and 4, respectively. Monte Carlo-simulations from these distributions showed that a total of 200 patients, 100 in each arm, would yield a statistical power of 90% for Mann-Whitney U-test at a significance level of 0.05.
In total, 200 consecutive patients with indication of are expected to be randomized in the study (100 patients in each arm, intramuscular vs subcutaneously). In Region Gavleborg , the annual primary implant volume of bradycardia pacemakers is approximately 220.
Figure 1. Assumed distributions of patient overall satisfaction in the power analysis, as measured by an visual analogue scale where 0 means "very satisfied" and 10 means "very dissatisfied". The intramuscular group is assumed to follow a lognormal distribution with mean 1.5 and standard deviation of 1, on the logarithmic scale. The subcutaneous patients are assumed to follow a lognormal distribution with mean 1.5 and standard deviation of 1, on the logarithmic scale.
Randomization: At the time of implant 1:1 randomization (100 patients in each group) to either subcutaneous (usual care) or intramuscular implant, in blocks with random block sizes. The randomization is performed by a statistician with no insight in the ongoing clinical work and patients' group allocation is revealed for implanting physician by the assistant nurse at the start of the surgical procedure. Randomization procedure: stratification (age strata: ≤65 years and >65 years) and sex (female, male); totally 4 strata). Consecutive group allocations will be stored in sealed opaque envelopes that will be opened at the time of starting the implant procedure.
Inclusion: Indication of a bradycardia pacemaker (DDDR, VVIR). Exclusion: Cardiac Resynchronisation Therapy Pacemaker (CRTP), Cardiac Resynchronisation Therapy Defibrillator (CRTD), implantable cardioverter defibrillator (ICD). Very skinny patient deemed as such by implanting physician to clearly benefit from intramuscular implant.
Surgical procedure: Standard procedure and vascular access by each operator's preference. Blunt dissection of the pocket.
Statistical methods: For comparisons between groups: Mann-Whitney U-test. For test of changes in VAS-estimations between 1, 12, and 24 months: pair-wise Wilcoxon signed-rank test.
Informed consent: Written and oral information by nurse/physician before implant.
Ethical approval: Approved by Uppsala Regional Committee. Clinical Trial Registration: Registration before start of study.
Variables:
Clinical variables: age, sex, coronary artery disease, open-heart surgery, diabetes, kidney disease Pacemaker system: (VVIR, DDDR), brand, model (lead(s) and device. Vascular access: (cephalic, axillary, subclavian vein), fluro-time, procedure time Periprocedural analgetics (dosage): alfentanil, morphine, diazepam, paracetamol Pre och post-operative anticoagulant medication (dosage and withdrawal with respect to procedure: acetylic acid, clopidogrel, ticagrelor, dual oral anticoagulants, warfarin, low-molecular weight heparin) Preoperative current medication: (psychoactive drugs, betablockers, corticosteroids, inflammatory modulating drugs Outcome measurements: Patient satisfaction (overall, chronic pain, discomfort, degree of unsightly look, movement disorder due to device, sleep problems due to device) scale 0-10 (10 worst) Paper questionnaire at 1,12,and 24 months. Patient knowledge if device was intramuscular or subcutaneously implanted at 24 months.
Pacemaker nurse judgement: unsightly look (0-10, 10 worst). Physician evaluation (blinded to the patient and not operator in the study): photo of pocket (1, 12, 24 months) scale 0-10 (10 worst).
Complications requiring surgery: pocket revision, dislodgment, hematoma requiring surgery, infection (local, systemic), pneumothorax, pericardial effusion requiring drainage, other.
Clinical perspectives: The surgical approach to the pacemaker pocket needs to be evaluated. The optimal approach including patient reported outcomes may result in more long-term satisfaction and may reduce the need for pocket revisions.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Single blind (participant)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| subcutaneous pacemaker | Active comparator | Device: subcutaneous pacemakerThe patients who are randomized to receive a subcutaneously implanted pacemaker |
| intramuscular pacemaker | Active comparator | Device: intramuscular pacemakerThe patients who are randomized to receive an intramuscular implanted pacemaker |
Who may qualify
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Child, Adult, Older adult
Key inclusion criteria (1 listed)
- Indication of a bradycardia pacemaker (DDDR, VVIR).
Key exclusion criteria (2 listed)
- CRTP, CRTD, ICD.
- Very skinny patient deemed as such by implanting physician to clearly benefit from intramuscular implant.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| subcutaneous pacemakerDuring implant of a pacemaker the device is either implanted subcutaneously or intramuscular | Device | subcutaneous pacemaker |
| intramuscular pacemakerDuring implant of a pacemaker the device is either implanted subcutaneously or intramuscular | Device | intramuscular pacemaker |
Primary outcome
patient overall satisfaction
Time frame: 24 months
Is there a different in patient overall satisfaction (on a VAS-scale between 0-10) with the pocket between patients with intramuscular placement of a pacemaker pocket and patients with subcutaneous placement at 24 months after implant?
8 secondary outcomes
complications due to pacemaker procedure
Time frame: 24 months
pain problems due to pacemaker device
Time frame: 24 months
discomfort due to pacemaker device
Time frame: 24 months
Patient own judgement of degree of unsightly look due to pacemaker device
Time frame: 24 months
movement problems due to device
Time frame: 24 months
sleep problems due to device
Time frame: 24 months
Pacemaker nurse judgement of unsightly look of the pacemaker pocket
Time frame: 24 months
Picture of pocket
Time frame: 24 months
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 13 Oct 2016.
- Background: PubMed 23801822Brignole M, Auricchio A, Baron-Esquivias G, Bordachar P, Boriani G, Breithardt OA, Cleland J, Deharo JC, Delgado V, Elliott PM, Gorenek B, Israel CW, Leclercq C, Linde C, Mont L, Padeletti L, Sutton R, Vardas PE; ESC Committee for Practice Guidelines (CPG); Zamorano JL, Achenbach S, Baumgartner H, Bax JJ, Bueno H, Dean V, Deaton C, Erol C, Fagard R, Ferrari R, Hasdai D, Hoes AW, Kirchhof P, Knuuti J, Kolh P, Lancellotti P, Linhart A, Nihoyannopoulos P, Piepoli MF, Ponikowski P, Sirnes PA, Tamargo JL, Tendera M, Torbicki A, Wijns W, Windecker S; Document Reviewers; Kirchhof P, Blomstrom-Lundqvist C, Badano LP, Aliyev F, Bansch D, Baumgartner H, Bsata W, Buser P, Charron P, Daubert JC, Dobreanu D, Faerestrand S, Hasdai D, Hoes AW, Le Heuzey JY, Mavrakis H, McDonagh T, Merino JL, Nawar MM, Nielsen JC, Pieske B, Poposka L, Ruschitzka F, Tendera M, Van Gelder IC, Wilson CM. 2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy: the Task Force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). Eur Heart J. 2013 Aug;34(29):2281-329. doi: 10.1093/eurheartj/eht150. Epub 2013 Jun 24. No abstract available.
- Background: PubMed 25336667Gadler F, Valzania C, Linde C. Current use of implantable electrical devices in Sweden: data from the Swedish pacemaker and implantable cardioverter-defibrillator registry. Europace. 2015 Jan;17(1):69-77. doi: 10.1093/europace/euu233. Epub 2014 Oct 21.
- Background: PubMed 19176569Rajappan K. Permanent pacemaker implantation technique: part II. Heart. 2009 Feb;95(4):334-42. doi: 10.1136/hrt.2008.156372. No abstract available.
- Background: PubMed 19144885Rajappan K. Permanent pacemaker implantation technique: part I: arrhythmias. Heart. 2009 Mar;95(3):259-64. doi: 10.1136/hrt.2007.132753. No abstract available.
- Background: PubMed 24347317Kirkfeldt RE, Johansen JB, Nohr EA, Jorgensen OD, Nielsen JC. Complications after cardiac implantable electronic device implantations: an analysis of a complete, nationwide cohort in Denmark. Eur Heart J. 2014 May;35(18):1186-94. doi: 10.1093/eurheartj/eht511. Epub 2013 Dec 17.
- Background: PubMed 15009864Kistler PM, Fynn SP, Mond HG, Eizenberg N. The subpectoral pacemaker implant: it isn't what it seems! Pacing Clin Electrophysiol. 2004 Mar;27(3):361-4. doi: 10.1111/j.1540-8159.2004.00442.x.
- Background: PubMed 9121991Gold MR, Peters RW, Johnson JW, Shorofsky SR. Complications associated with pectoral implantation of cardioverter defibrillators. World-Wide Jewel Investigators. Pacing Clin Electrophysiol. 1997 Jan;20(1 Pt 2):208-11. doi: 10.1111/j.1540-8159.1997.tb04844.x.
- Individual participant dataSharing planned: Yes. IPD will be available (without identification of each individual) upon request by the journal (i.e Supplement file)
Related trials for Pacemaker Ddd
RecruitingObservational study
Prospective Database for Prediction of Atrial Fibrillation in Pacemaker and ICD Patients
Atrial Fibrillation, Pacemaker Ddd
RecruitingObservational study
Non-Invasive Method for Evaluation of Cardiac Resynchronization Therapy
Heart Failure, Pacemaker DDD
RecruitingObservational study
Left Bundle Branch Area Mapping for Conduction System Pacing
Left Bundle-Branch Block, Pacemaker DDD
Active, not recruitingPhase 4
The Leadless AV Versus DDD Pacing Study
Cardiac Pacemaker, Arrhythmias, Cardiac
Active, not recruiting
Danish Randomized Trial on Leadless vs Transvenous Pacing
AV Block
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Per Liv, Ph.D principal investigator
Centre for Research and Development Gavleborg/Uppsala University
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing subcutaneous pacemaker and intramuscular pacemaker in people with Pacemaker Ddd, run by Region Gävleborg at 1 site in Sweden.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 13 Oct 2016. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Sweden. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
Contact Peter M Magnusson, M.D. (+46 705 089407, peter.magnusson@regionagavleborg.se), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
patient overall satisfaction (time frame: 24 months). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT02931760, which also lists 7 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 13 Oct 2016.