Trial summary
Hypovolemia and acute circulatory failure affects more than 60% of patients hospitalized in intensive care or resuscitation. The volume expansion (VE) by fluid replacement therapy is the first treatment improve circulatory function. However, too much VE can be harmful. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Sepsis, Respiratory Physiological Phenomena, Circulatory Failure
- What is being tested?
- Echocardiography-Doppler
- Type of treatment
- Injection or infusion
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 90 participants
- Where
- 1 siteFrance
- Study dates
- Nov 2011to Feb 2014
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Adult patients of the intensive care units of the Lille university-hospital and of the Valenciennes general hospital.
- Age greater than or equal to 18.
- Patient insured
- Spontaneous breathing without ventilatory support or intubation or tracheotomy.
- Regular cardiac rhythm
- Prescription by the physician in charge of the patients of a 500 mL volume expansion in less than 30 minutes.
Show all 11Show fewer
- Patients with sepsis with at least one sign of acute circulatory failure:
- Tachycardia with heart rate> 100/min
- systolic blood pressure <90mmHg or a decrease >40mmHg in previously hypertense patient
- Oliguria <0.5ml/kg/hour for at least one hour
- skin mottling
Who cannot join
- high-grade aortic insufficiency
- transthoracic echogenicity unsuitable for measuring the stroke volume or inferior vena cava diameters
- clinical signs of active exhalation
- clinical or ultrasonographic evidence of pulmonary edema due to heart failure
- pregnancy
- abdominal compartment syndrome
- Irregular cardiac rhythm
Trial locations and contacts
1 site in 1 country.
France1 site
Intensive Care Department, Salengro Hospital, CHU de Lille
Lille, Hauts-de-France, 59000
About this study
Official title: Respiratory Variations of the Inferior Vena Cava and Femoral Artery Flow to Predict Fluid Responsiveness in Spontaneously Breathing Patients With Sepsis, Acute Circulatory Failure, and Regular Cardiac Rhythm
Hypovolemia and acute circulatory failure affects more than 60% of patients hospitalized in intensive care or resuscitation. The volume expansion (VE) by fluid replacement therapy is the first treatment improve circulatory function. However, too much VE can be harmful. So, the use of dynamic predictive indicators of fluid responsiveness is recommended in patients with sepsis.In patients with spontaneous ventilation, few studies have evaluated these parameters. In mechanical ventilation, indices based on the respiratory variation of the diameters of vena cava have been studied and validated to predict the response to VE. However there is no similar study in spontaneously breathing patients without ventilatory support. The investigators hypothesize that the respiratory variations in the IVC diameters and femoral artery flow during standardized respiratory cycles are predictive factors of fluid responsiveness in spontaneously breathing patients with sepsis, acute circulatory failure, and regular cardiac rhythm.
- Being tested
- Echocardiography-Doppler
- Keywords
- Spontaneous ventilation
- Medical subject headings
- Sepsis, Shock
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Echocardiography-DopplerOther
Ultrasonographic recordings are recorded immediately before and after volume expansion (VE), performed as a 30-minute infusion of 500 mL of 4% gelatin. Inferior Vena Cava diameters are measured during spontaneous and standardized respiratory cycles. Stroke volume is measured during spontaneous respiratory cycles.
| Study group | Role | What they receive |
|---|---|---|
| Echocardiography-Doppler | Experimental | Ultrasonographic recordings, systemic arterial pressure, heart rate, and respiratory rate are recorded immediately before and after volume expansion (VE), performed as a 30-minute infusion of 500 mL of 4% gelatin. Inferior Vena Cava diameters are measured during spontaneous and standardized respiratory cycles. Stroke volume is measured during spontaneous respiratory cycles. Receives: Other: Echocardiography-Doppler |
What is being measured
The primary outcome is the main question the study is designed to answer.
"respiratory variations in inferior vena cava diameters" with respect to the response to fluid resuscitation, assessed by the area under the ROC curve
Measured: during 30 minutes of the volume expansion
Secondary outcomes (1)
"respiratory variations the femoral artery flow" with respect to the response to fluid resuscitation, assessed by the area under the ROC curve
Measured: during 30 minutes of the volume expansion
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted28 Feb 2017
- Study startNov 2011
- Primary completionJan 2014
- Study completionFeb 2014
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (1)Papers the sponsor has linked to this study.
- Other trials for SepsisStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Diagnosis
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 90 participants (actual)
Sponsor and investigators
- Lead sponsor
- University Hospital, Lille
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- Sebastien Preau, MD, PhD, Principal investigator, University Hospital, Lille
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03066362
- Sponsor's protocol ID
- 2011_10
- Other IDs
- 2011-A00990-41
- Acronym
- ReVaPreF
- Status last verified
- Feb 2017
- First submitted
- 9 Nov 2016
- Last updated
- 22 Apr 2026
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
Bortolotti P, Colling D, Colas V, Voisin B, Dewavrin F, Poissy J, Girardie P, Kyheng M, Saulnier F, Favory R, Preau S. Respiratory changes of the inferior vena cava diameter predict fluid responsiveness in spontaneously breathing patients with cardiac arrhythmias. Ann Intensive Care. 2018 Aug 2;8(1):79. doi: 10.1186/s13613-018-0427-1.
PubMed 30073423
Study at a glance
From the registry record, last updated by the sponsor on 22 Apr 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Respiratory Variations of the Inferior Vena Cava and Femoral Artery Flow to Predict Fluid Responsiveness in Spontaneously Breathing Patients With Sepsis, Acute Circulatory Failure, and Regular Cardiac Rhythm
- ClinicalTrials.gov ID
- NCT03066362
- Acronym / sponsor ID
- ReVaPreF / 2011_10
- Keywords
- Spontaneous ventilation
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 90 participants (actual)
- Lead sponsor
- University Hospital, LilleUniversity, hospital or other
- Study start
- Nov 2011
- Primary completion
- Jan 2014 (actual)
- Study completion
- Feb 2014 (actual)
- First posted
- 28 Feb 2017 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Hypovolemia and acute circulatory failure affects more than 60% of patients hospitalized in intensive care or resuscitation. The volume expansion (VE) by fluid replacement therapy is the first treatment improve circulatory function. However, too much VE can be harmful. So, the use of dynamic predictive indicators of fluid responsiveness is recommended in patients with sepsis.In patients with spontaneous ventilation, few studies have evaluated these parameters. In mechanical ventilation, indices based on the respiratory variation of the diameters of vena cava have been studied and validated to predict the response to VE. However there is no similar study in spontaneously breathing patients without ventilatory support. The investigators hypothesize that the respiratory variations in the IVC diameters and femoral artery flow during standardized respiratory cycles are predictive factors of fluid responsiveness in spontaneously breathing patients with sepsis, acute circulatory failure, and regular cardiac rhythm.
Study design
- Primary purpose
- Diagnosis
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Echocardiography-Doppler | Experimental | Other: Echocardiography-DopplerUltrasonographic recordings, systemic arterial pressure, heart rate, and respiratory rate are recorded immediately before and after volume expansion (VE), performed as a 30-minute infusion of 500 mL of 4% gelatin. Inferior Vena Cava diameters are measured during spontaneous and standardized respiratory cycles. Stroke volume is measured during spontaneous respiratory cycles. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (11 listed)
- Adult patients of the intensive care units of the Lille university-hospital and of the Valenciennes general hospital.
- Age greater than or equal to 18.
- Patient insured
- Spontaneous breathing without ventilatory support or intubation or tracheotomy.
- Regular cardiac rhythm
Key exclusion criteria (7 listed)
- high-grade aortic insufficiency
- transthoracic echogenicity unsuitable for measuring the stroke volume or inferior vena cava diameters
- clinical signs of active exhalation
- clinical or ultrasonographic evidence of pulmonary edema due to heart failure
- pregnancy
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Echocardiography-DopplerUltrasonographic recordings are recorded immediately before and after volume expansion (VE), performed as a 30-minute infusion of 500 mL of 4% gelatin. Inferior Vena Cava diameters are measured during spontaneous and standardized respiratory cycles. Stroke volume is measured during spontaneous respiratory cycles. | Other | Echocardiography-Doppler |
Primary outcome
"respiratory variations in inferior vena cava diameters" with respect to the response to fluid resuscitation, assessed by the area under the ROC curve
Time frame: during 30 minutes of the volume expansion
1 secondary outcome
"respiratory variations the femoral artery flow" with respect to the response to fluid resuscitation, assessed by the area under the ROC curve
Time frame: during 30 minutes of the volume expansion
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 22 Apr 2026.
- Results publication: PubMed 30073423Bortolotti P, Colling D, Colas V, Voisin B, Dewavrin F, Poissy J, Girardie P, Kyheng M, Saulnier F, Favory R, Preau S. Respiratory changes of the inferior vena cava diameter predict fluid responsiveness in spontaneously breathing patients with cardiac arrhythmias. Ann Intensive Care. 2018 Aug 2;8(1):79. doi: 10.1186/s13613-018-0427-1.
- Individual participant dataSharing planned: No
Related trials for Sepsis
Not yet recruitingObservational study
Serum GDF-15 and LGALS3BP as Prognostic Biomarkers in Sepsis
Sepsis, Septic Shock
RecruitingPhase 3
A Trial of Adjunctive Fludrocortisone (50mcg, 100mcg or Placebo) in Critically Ill Patients With Septic Shock Receiving Hydrocortisone, Evaluating Survival and Functional Recovery and the Influence of Transcriptomic Response
Septic Shock
RecruitingObservational study
Middle East Study of Infections in Patients With Hematological Malignancies
Hematological Malignancy, Hematopoetic Stem Cell Transplantation
RecruitingObservational study
Early Detection and Kinetics of Sepsis-Induced Coagulopathy in Severe Burn Patients
Peer Bullying Intervention, Vodcast
Not yet recruitingObservational study
Comparative Study of the Genomic Characteristics of Uropathogenic Escherichia Coli According to the Severity of Community-Acquired Urinary Tract Infections in Guadeloupe (COLIGENURI)
Urinary Tract Infections
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Sebastien Preau, MD, PhD principal investigator
University Hospital, Lille
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Echocardiography-Doppler in people with Sepsis and Respiratory Physiological Phenomena, run by University Hospital, Lille at 1 site in France.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 11 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 22 Apr 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in France. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
"respiratory variations in inferior vena cava diameters" with respect to the response to fluid resuscitation, assessed by the area under the ROC curve (time frame: during 30 minutes of the volume expansion). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT03066362, which also lists 1 linked publication.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 22 Apr 2026.