Intracranial HemorrhagesCUSPICPNCT03115450

Comparison of Pupilometer and Ultrasound of Optic Nerve Sheath Diameter in Estimating Intracranial Pressure (ICP)

An observational study of Intracranial Hemorrhages and Brain Injuries, run by Loma Linda University at 1 site in United States.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The purpose of this investigator-initiated study is to compare the use of pupilometer and ultrasound assessment of optic nerve sheath diameter in predicting the ICP and to see if there is a value that could be used to indicate elevated ICP with either modality as these numbers are inconsistent throughout the… Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Ultrasound and Pupilometer
Type of treatment
Medical device
How many people
51 participants
Where
1 siteUnited States
Study dates
1 Apr 2018to 15 Jun 2018
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Adults that have intracranial pathology requiring either EVD or bolt placement for measuring ICP.

Who may be able to join

  • Age greater than or equal to 18 years old
  • Intracranial pathology requiring either EVD or bolt placement for ICP measurement

Who cannot join

  • Known disorder of lens or orbit including but not limited to glaucoma, cataract, blindness, lens implants.
  • Patients unable to close eyelids as this would increase risk of corneal abrasion from ultrasound probe.

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Loma Linda University Medical Center

    Loma Linda, California, 92354

Other trials in United States

About this study

Official title: Comparative Analysis of Pupilometer and Ultrasound Assessment of Optic Nerve Sheath Diameter in Estimating Intracranial Pressure (ICP)

The purpose of this investigator-initiated study is to compare the use of pupilometer and ultrasound assessment of optic nerve sheath diameter in predicting the ICP and to see if there is a value that could be used to indicate elevated ICP with either modality as these numbers are inconsistent throughout the literature. Patients that have either an external ventricular drain (EVD) or bolt placed will be enrolled in the study. After the EVD and bolt are placed the patient will undergo pupilometer examination (standard of care) followed by ultrasound assessment of the optic nerve sheath diameter (ONSD). The three values will be recorded. The same patient may have multiple readings performed if there is a change in ICP either spontaneously or due to intervention.

Being tested
Ultrasound, Pupilometer
Keywords
External ventricular drain (EVD), Placement of Bolt
Medical subject headings
Intracranial Hemorrhages, Brain Injuries, Subarachnoid Hemorrhage, Ischemic Stroke, Stroke

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • UltrasoundDevice

    Type of imaging technology to look at organs and structures inside the body

  • PupilometerDevice

    A device that measures pupil size and how it changes.

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Measurement of Optic Nerve Sheath Diameter (ONSD) and corresponding intracranial pressure (ICP).

    Analysis of varying ONSD and pupillometer readings to concurrent ICP

    Measured: 1 day of ONSD examination

Secondary outcomes (1)
  1. Measurement of Pupillometer reading and corresponding intracranial pressure (ICP).

    Comparison of Neurological Pupil index (NPi) in both eye and concurrent ICP

    Measured: 1 day per nursing protocol (standard of care)

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted14 Apr 2017
  2. Study start1 Apr 2018
  3. Primary completion15 Jun 2018
  4. Study completion15 Jun 2018

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case only
Time perspective
Prospective
Enrolment
51 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03115450
Sponsor's protocol ID
5170065
Acronym
CUSPICP
Status last verified
Oct 2021
First submitted
27 Mar 2017
Last updated
26 Oct 2021
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes

Publications

  • Chen JW, Gombart ZJ, Rogers S, Gardiner SK, Cecil S, Bullock RM. Pupillary reactivity as an early indicator of increased intracranial pressure: The introduction of the Neurological Pupil index. Surg Neurol Int. 2011;2:82. doi: 10.4103/2152-7806.82248. Epub 2011 Jun 21.

    PubMed 21748035
  • Park JG, Moon CT, Park DS, Song SW. Clinical Utility of an Automated Pupillometer in Patients with Acute Brain Lesion. J Korean Neurosurg Soc. 2015 Oct;58(4):363-7. doi: 10.3340/jkns.2015.58.4.363. Epub 2015 Oct 30.

    PubMed 26587191
  • Taylor WR, Chen JW, Meltzer H, Gennarelli TA, Kelbch C, Knowlton S, Richardson J, Lutch MJ, Farin A, Hults KN, Marshall LF. Quantitative pupillometry, a new technology: normative data and preliminary observations in patients with acute head injury. Technical note. J Neurosurg. 2003 Jan;98(1):205-13. doi: 10.3171/jns.2003.98.1.0205.

    PubMed 12546375
  • Fountas KN, Kapsalaki EZ, Machinis TG, Boev AN, Robinson JS, Troup EC. Clinical implications of quantitative infrared pupillometry in neurosurgical patients. Neurocrit Care. 2006;5(1):55-60. doi: 10.1385/NCC:5:1:55.

    PubMed 16960298
  • Meeker M, Du R, Bacchetti P, Privitera CM, Larson MD, Holland MC, Manley G. Pupil examination: validity and clinical utility of an automated pupillometer. J Neurosci Nurs. 2005 Feb;37(1):34-40.

    PubMed 15794443
  • Shirodkar CG, Munta K, Rao SM, Mahesh MU. Correlation of measurement of optic nerve sheath diameter using ultrasound with magnetic resonance imaging. Indian J Crit Care Med. 2015 Aug;19(8):466-70. doi: 10.4103/0972-5229.162465.

    PubMed 26321806
  • Wroblewski JT, Fadda E, Mazzetta J, Lazarewicz JW, Costa E. Glycine and D-serine act as positive modulators of signal transduction at N-methyl-D-aspartate sensitive glutamate receptors in cultured cerebellar granule cells. Neuropharmacology. 1989 May;28(5):447-52. doi: 10.1016/0028-3908(89)90077-4.

    PubMed 2542835
  • Kimberly HH, Shah S, Marill K, Noble V. Correlation of optic nerve sheath diameter with direct measurement of intracranial pressure. Acad Emerg Med. 2008 Feb;15(2):201-4. doi: 10.1111/j.1553-2712.2007.00031.x.

    PubMed 18275454

Questions about this trial

What is this clinical trial studying?

An observational study of Intracranial Hemorrhages and Brain Injuries, run by Loma Linda University at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 26 Oct 2021. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Measurement of Optic Nerve Sheath Diameter (ONSD) and corresponding intracranial pressure (ICP). (time frame: 1 day of ONSD examination). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03115450, which also lists 8 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 26 Oct 2021.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in