Surgery in Elderly PatientsNCT03178162
Evaluation of a Non-invasive Cardiac Output Monitoring System.
An observational study of Surgery in Elderly Patients and Hemodynamics, run by University Hospital Schleswig-Holstein at 1 site in Germany.
Trial summary
There are different methods for measuring cardiac output (CO) completely non-invasive, which are used today. Two of these should be used in the study to examine the CO in an older group of patients (> 65 years) undergoing major trauma surgery. Read more about this study
- Who is it for?
- Ages 65 years and older
- Conditions the study is for
- Surgery in Elderly Patients, Hemodynamics, Pulse Wave Transit Time
- How many people
- 60 participants
- Where
- 1 siteGermany
- Study dates
- 1 Dec 2015to 1 Jun 2017
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 65 years and older
- All sexes
- No healthy volunteers
- Older adult
Study population: Elderly patients older than 65 years who will participate in vascular or trauma surgery.
Who may be able to join
- Major surgery (elective or urgent) in vascular surgery and trauma surgery
- Patient´s rating according to ASA physical status classification system with 2-4
- Written consent by patient
- Age > 65
Who cannot join
- ASA 5
- Patient requiring high doses of catecholamine already before surgery
- Cognitive or language barriers restricting informant consent of patient
- Denial of participation by the patient
- emergency surgery
Trial locations and contacts
1 site in 1 country.
Germany1 site
Universitätsklinikum Schleswig-Holstein Campus Kiel - Klinik für Anästhesiologie und Operative Intensivmedizin
Kiel, 24105
About this study
Official title: Evaluation of a Non-invasive Cardiac Output Monitoring System in Comparison to the Semi-invasive Monitoring System FloTrac VigileoTechnology in Elderly Patients.
There are different methods for measuring cardiac output (CO) completely non-invasive, which are used today. Two of these should be used in the study to examine the CO in an older group of patients (> 65 years) undergoing major trauma surgery. The first method is the esCCOTM-technology by Nihon Kohden, the second uses the Volume Clamped Method via a finger-cuff by Nexfin Edwards life sciences. Both technologies work continuously and fully non-invasive.
The measured data will be compared to established standard procedures like semi-invasive pulse contour analysis using the Flotrac-Vigileo system. The study should answer the following questions:
How accurate and precise are the non-invasive methods? How large is the percentage deviation in comparison to the established standard? Are there any limitations of measuring accuracy regarding the age of the patient? The continuous hemodynamic monitoring of patients during surgery has recently changed from invasive and semi-invasive methods to completely non-invasive technologies. The accuracy and precision of this way of measuring cardiovascular parameters in comparison to the invasive standard is still controversial. Especially for older patient with atherosclerotic alteration of the blood vessels the utility of non-invasive monitoring systems is not shown yet. But principally this group with a high level of comorbidity might profit notably from less invasive procedures. This is the reason for the planed research.
Read the detailed description
The Nexfin® monitoring system by Edwards life sciences could measure continuous non-invasive blood pressure through a finger-cuff for every single heart beat; moreover it calculates a CO and stroke-volume parameter utilizing a so-called pulse contour analysis provided by the non-invasive blood pressure measurement. This technology is based on an inflatable doublefinger-cuff wristband, which is attached to the patients hand and connected to a monitor. Using this wristband the arterial pressure within the patient's digital arteries will be continuously registered. Using a heart-frequency adapted algorithm - based on an alignment chart including healthy patients, patients with arterial hypertonia and micro/macro angiopathia - the software is also able to measure the brachial artery blood pressure.
First evaluations regarding non-invasive blood pressure measurement were very promising. However, data especially in elderly patients and patients with vascular disease are still not available.
The esCCO monitor (estimated Continuous Cardiac Output) by Nihon Kohden (Nihon Kohden Europe GmbH, 61191 Rosbach, Deutschland) is another completely non-invasive measurement device, which is based on the pulse wave transit time (PWTT) as well as non-invasive blood pressure measurement, ECG and pulse oximetry. PWTT provides time adapted information, e.g. intravascular pressure transmission or information on changes in the arterial blood volume.
Besides common vital signs such as SpO2, RR and ECG, esCCO™ also offers a realtime non-invasive CO-measurement. Mainly, the esCCO™ principle is based on the possibility to obtain CO-values using pulse pressure analysis: CO = SV × HR = (C × PP) × HR [SV: stroke volume; C: constant value; PP: Pulse Pressure; HR: Heart Rate]. Since studies have shown that there is a greater correlation between SV and PWTT than between SV and PP, the CO calculation was stated as followed as a result of the PWTT information: CO = SV × HR= C × (α × PWTT + β) × HR = esCCO [α, β: experimental constants].
Demographic changes but also clinical everyday life indicates a strong increase in older patients undergoing surgery. The percentages of risk or high-risk patients with relevant comorbidities will therefore tremendously increase as well. If it is possible to adequately monitor this particular collective continuously with even less invasive technologies is to be answered by this clinical trial.
During surgery the hemodynamic parameters will be measured continuously and documented every 15 minutes or in special situation like hypotension or when vasoactive agents need to be given.
There will be no additional risk for the patient participating in the study, because the used devices and procedures have already been tested clinically. In general the preoperative preparation will be not different to the usual procedure. If a patient denies to participate the trial or withdraw his or her agreement afterwards there will be no disadvantage in terms of medical care for him or her. The people will be informed about this fact when he or she gives the agreement to the examination.
If a change of the surgical procedure or anaesthesia occurs its management will be given priority and the examination for the trial will stop quickly. Any adverse event potentially caused by the study will entail an interruption of the trial until its reason is found; the ethics committee will be informed immediately.
The planed clinical trial deals with the evaluation of different methods (invasive vs. non-invasive) to measure cardiac output and other parameters. For interpretation purpose the method of Bland and Altman will be used to calculate the average deviation (bias) and precesion (mean value ± 2 standard deviations). The mean percentage error will be determined in accordance to the criteria described by Critchley and Critchley. The Bland-Altman analysis will be expanded by repeated measurements per patient and point in time.
There is no mentionable, additional risk that the patient will be exposed to in course of the study since there is only monitoring systems being applied that are either fully clinically established or completely non-invasive.
Generated data will include common cardio-vascular parameters, such as: ECG, invasive as well as non-invasive blood pressure, oxygen saturation, endexpiratory CO2- partial pressure, cardiac output and stroke volume (both semi-invasively as well as non-invasively generated), echocardiographically generated data such as stroke volume, volume demand and cardiac output.
- Keywords
- limitation in conventional monitoring
What is being measured
The primary outcome is the main question the study is designed to answer.
cardiac output
Comparison of cardiac output, utilizing cardiac index (CI), between (esCCO™ Nihon Khoden) and the Flotrac-Vigileo (Edward Lifesciences) monitoring system.
Measured: through study completion, an average of 1,5 years
Secondary outcomes (1)
pulse wave transit time (PWTT)
relevance of the measured time
Measured: through study completion, an average of 1,5 years
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted6 Jun 2017
- Study start1 Dec 2015
- Primary completion1 Jun 2017
- Study completion1 Jun 2017
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Surgery in Elderly PatientsStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Other
- Time perspective
- Prospective
- Enrolment
- 60 participants (actual)
Sponsor and investigators
- Lead sponsor
- University Hospital Schleswig-Holstein
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Dr. Jochen Renner, University Hospital Schleswig-Holstein
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03178162
- Sponsor's protocol ID
- IN-OCT-02
- Status last verified
- Jun 2017
- First submitted
- 3 Jun 2017
- Last updated
- 6 Jun 2017
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 6 Jun 2017. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Evaluation of a Non-invasive Cardiac Output Monitoring System in Comparison to the Semi-invasive Monitoring System FloTrac VigileoTechnology in Elderly Patients.
- ClinicalTrials.gov ID
- NCT03178162
- Acronym / sponsor ID
- IN-OCT-02
- Keywords
- limitation in conventional monitoring
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 60 participants (actual)
- Lead sponsor
- University Hospital Schleswig-HolsteinUniversity, hospital or other
- Study start
- 1 Dec 2015 (actual)
- Primary completion
- 1 Jun 2017 (actual)
- Study completion
- 1 Jun 2017 (actual)
- First posted
- 6 Jun 2017 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
There are different methods for measuring cardiac output (CO) completely non-invasive, which are used today. Two of these should be used in the study to examine the CO in an older group of patients (> 65 years) undergoing major trauma surgery. The first method is the esCCOTM-technology by Nihon Kohden, the second uses the Volume Clamped Method via a finger-cuff by Nexfin Edwards life sciences. Both technologies work continuously and fully non-invasive.
The measured data will be compared to established standard procedures like semi-invasive pulse contour analysis using the Flotrac-Vigileo system. The study should answer the following questions:
How accurate and precise are the non-invasive methods? How large is the percentage deviation in comparison to the established standard? Are there any limitations of measuring accuracy regarding the age of the patient? The continuous hemodynamic monitoring of patients during surgery has recently changed from invasive and semi-invasive methods to completely non-invasive technologies. The accuracy and precision of this way of measuring cardiovascular parameters in comparison to the invasive standard is still controversial. Especially for older patient with atherosclerotic alteration of the blood vessels the utility of non-invasive monitoring systems is not shown yet. But principally this group with a high level of comorbidity might profit notably from less invasive procedures. This is the reason for the planed research.
Detailed description
The Nexfin® monitoring system by Edwards life sciences could measure continuous non-invasive blood pressure through a finger-cuff for every single heart beat; moreover it calculates a CO and stroke-volume parameter utilizing a so-called pulse contour analysis provided by the non-invasive blood pressure measurement. This technology is based on an inflatable doublefinger-cuff wristband, which is attached to the patients hand and connected to a monitor. Using this wristband the arterial pressure within the patient's digital arteries will be continuously registered. Using a heart-frequency adapted algorithm - based on an alignment chart including healthy patients, patients with arterial hypertonia and micro/macro angiopathia - the software is also able to measure the brachial artery blood pressure.
First evaluations regarding non-invasive blood pressure measurement were very promising. However, data especially in elderly patients and patients with vascular disease are still not available.
The esCCO monitor (estimated Continuous Cardiac Output) by Nihon Kohden (Nihon Kohden Europe GmbH, 61191 Rosbach, Deutschland) is another completely non-invasive measurement device, which is based on the pulse wave transit time (PWTT) as well as non-invasive blood pressure measurement, ECG and pulse oximetry. PWTT provides time adapted information, e.g. intravascular pressure transmission or information on changes in the arterial blood volume.
Besides common vital signs such as SpO2, RR and ECG, esCCO™ also offers a realtime non-invasive CO-measurement. Mainly, the esCCO™ principle is based on the possibility to obtain CO-values using pulse pressure analysis: CO = SV × HR = (C × PP) × HR [SV: stroke volume; C: constant value; PP: Pulse Pressure; HR: Heart Rate]. Since studies have shown that there is a greater correlation between SV and PWTT than between SV and PP, the CO calculation was stated as followed as a result of the PWTT information: CO = SV × HR= C × (α × PWTT + β) × HR = esCCO [α, β: experimental constants].
Demographic changes but also clinical everyday life indicates a strong increase in older patients undergoing surgery. The percentages of risk or high-risk patients with relevant comorbidities will therefore tremendously increase as well. If it is possible to adequately monitor this particular collective continuously with even less invasive technologies is to be answered by this clinical trial.
During surgery the hemodynamic parameters will be measured continuously and documented every 15 minutes or in special situation like hypotension or when vasoactive agents need to be given.
There will be no additional risk for the patient participating in the study, because the used devices and procedures have already been tested clinically. In general the preoperative preparation will be not different to the usual procedure. If a patient denies to participate the trial or withdraw his or her agreement afterwards there will be no disadvantage in terms of medical care for him or her. The people will be informed about this fact when he or she gives the agreement to the examination.
If a change of the surgical procedure or anaesthesia occurs its management will be given priority and the examination for the trial will stop quickly. Any adverse event potentially caused by the study will entail an interruption of the trial until its reason is found; the ethics committee will be informed immediately.
The planed clinical trial deals with the evaluation of different methods (invasive vs. non-invasive) to measure cardiac output and other parameters. For interpretation purpose the method of Bland and Altman will be used to calculate the average deviation (bias) and precesion (mean value ± 2 standard deviations). The mean percentage error will be determined in accordance to the criteria described by Critchley and Critchley. The Bland-Altman analysis will be expanded by repeated measurements per patient and point in time.
There is no mentionable, additional risk that the patient will be exposed to in course of the study since there is only monitoring systems being applied that are either fully clinically established or completely non-invasive.
Generated data will include common cardio-vascular parameters, such as: ECG, invasive as well as non-invasive blood pressure, oxygen saturation, endexpiratory CO2- partial pressure, cardiac output and stroke volume (both semi-invasively as well as non-invasively generated), echocardiographically generated data such as stroke volume, volume demand and cardiac output.
Study design
- Observational model
- Other
- Time perspective
- Prospective
Who may qualify
- Ages
- 65 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Older adult
- Study population
- Elderly patients older than 65 years who will participate in vascular or trauma surgery.
Key inclusion criteria (4 listed)
- Major surgery (elective or urgent) in vascular surgery and trauma surgery
- Patient´s rating according to ASA physical status classification system with 2-4
- Written consent by patient
- Age > 65
Key exclusion criteria (5 listed)
- ASA 5
- Patient requiring high doses of catecholamine already before surgery
- Cognitive or language barriers restricting informant consent of patient
- Denial of participation by the patient
- emergency surgery
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Primary outcome
cardiac output
Time frame: through study completion, an average of 1,5 years
Comparison of cardiac output, utilizing cardiac index (CI), between (esCCO™ Nihon Khoden) and the Flotrac-Vigileo (Edward Lifesciences) monitoring system.
1 secondary outcome
pulse wave transit time (PWTT)
Time frame: through study completion, an average of 1,5 years
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 6 Jun 2017.
- Individual participant dataSharing planned: No
Related trials for Surgery in Elderly Patients
Recruiting
Lumbar Paravertebral Block vs Erector Spinae Plane Block in Elderly Patients Undergoing Lumbar Spine Surgery
Spine Disease
Active, not recruiting
Investigation of the Effects of Respiratory Muscle Training Combined With Otago Exercises in Elderly Patients Undergoing Coronary Artery Bypass Graft Surgery
Coronary Artery Bypass Graft (CABG)
Recruiting
Three Variants of the PENG Block With and Without Perineural Adjuvants in Older Adults
Hip Osteoarthritis
Not yet recruitingPhase 4
Effect of Ondansetron on the Incidence of Spinal Anaesthesia-Induced Hypotension in Elderly Patients Undergoing Fracture Hip Surgery
Spinal Anaesthesia Induced Hypotension
Not yet recruitingObservational study
Postprandial Hypotension, Frailty and Post-Induction Hypotension in Older Patients Undergoing Noncardiac Surgery
Post-induction Hypotension (PIH), Postprandial Hypotension
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Surgery in Elderly Patients and Hemodynamics, run by University Hospital Schleswig-Holstein at 1 site in Germany.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 6 Jun 2017. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Germany. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
cardiac output (time frame: through study completion, an average of 1,5 years). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 Jun 2017.