AzTrials
AzTrials

Cancer ColonNCT03179358

Clinical Trial Verifying C-REX LapAid and C-REX DMH/DMHC

A study testing C-REX Ring-locking Procedure in people with Cancer Colon and Polyp of Colon, run by Carponovum AB at 1 site in China.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

In colorectal surgery, hand suturing and stapling are routine methods for performing intestinal anastomoses, and these methods appear to be similar in terms of clinical safety. Despite several years of experience with surgical procedures as well as improvements to the medical devices, problems with disturbed… Read more about this study

Who is it for?
Ages 18 to 70 years
Conditions the study is for
Cancer Colon, Polyp of Colon
What is being tested?
C-REX Ring-locking Procedure
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
20 participants
Where
1 siteChina
Study dates
29 Sep 2016to 10 Jun 2017
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 70 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Male or female age ≥ 18 years and ≤ 70 years.
  • Planned resection due to benign or malign disease in the left colon (descending colon and sigmoid) or the upper rectum (15 cm above the anal rim).
  • Cognitive ability to take part in the study and understand the information he/she receives about participating in the study.
  • Sign the informed consent form.

Who cannot join

  • Urgent medical condition requiring immediate care.
  • Current surgical conditions, such as intestinal obstruction or perforation, local or systemic infections, peritonitis, intestinal ischemia or dissemination (metastases) of cancer.
  • Stenosis or other obstructions in the anal passage.
  • Previous major abdominal surgery, previous radiation therapy to organs in abdomen or pelvis.
  • Health condition classified as ASA (American Society of Anesthesiologists) score III - VI.
  • Albumin level less than 35 g/l.
Show all 16Show fewer
  • Inflammatory bowel disease (IBD) (ulcerative colitis or Crohn´s disease).
  • Disease that requires more than one anastomosis during the surgical procedure.
  • Treatment with cortisone and/or other immunosuppressive medications less than one month before surgery.
  • Contraindications to general anesthesia.
  • Perioperative detection of extreme variants of intestinal diameters or wall thickness.
  • Cognitive ability that limits the patient's ability to take part in the study and understand the information he/she received about participating in the study, or the patient does not agree to join the study.
  • BMI > 35.
  • Heart attack ≤ 6 months or sever heart disease.
  • Severe embolic disease.
  • Other conditions which surgeons think the patient should be excluded. -

Trial locations and contacts

1 site in 1 country.

China1 site
  • The First Affiliated Hospital of Xiamen University

    Xiamen, Fujian, 361003

Other trials in China

About this study

Official title: A Prospective, Non-randomized Multicenter Study Verifying C-REX LapAid and C-REX DMH/DMHC

In colorectal surgery, hand suturing and stapling are routine methods for performing intestinal anastomoses, and these methods appear to be similar in terms of clinical safety. Despite several years of experience with surgical procedures as well as improvements to the medical devices, problems with disturbed anastomotic healing leading to leakage and stenosis after colorectal surgery remain a significant challenge for surgeons. In addition, preoperative radiotherapy has been shown to increase the risk of anastomotic leakage even further.

The methods that are used today to detect leakages are unfortunately inaccurately and limited to monitoring symptoms, temperature, CRP (C-reactive protein)-levels, and performing abdominal examinations and CT-scans. These clinical signs and parameters usually become apparent several days after onset of the leakage, which leads to a delayed diagnosis. Anastomotic leakage is not only a significant cause of increased morbidity of complications and mortality in patients, but also associated with increased risk of local recurrence and poor prognosis. Moreover, when reoperation is required to fix the leakage, a permanent stoma may be made at the level of the sigmoid colon and this procedure impacts quality of life negatively.

Read more

Based on the above considerations, a novel, adaptive anastomotic method has been developed by CarpoNovum to achieve a safer anastomosis. The method's working name is C-REX Ring-locking Procedure (C-REX is referred to our Colorectal anastomotic rings for Re-join the intestinal ends and validate the anastomosis, with function of Extract samples for analysis and conduct X-ray through connected catheters).

The novel adaptive anastomotic medical devices, C-REX LapAid and C-REX DMH/DMHC are easy to use, with unique possibility to control the anastomosis during and after surgery. The previous successful preclinical study encourages a clinical verification in patients undergoing colonic resection to evaluate the safety and performance of C-REX Ring-locking Procedure by use of C-REX LapAid and C-REX DMH/DMHC.

Read the detailed description

OVERALL DESIGN The study is a prospective, multicenter, single arm study Possible study candidates are patients requiring resection of the left colon (descending colon and sigmoid) or the upper rectum (15cm above the anal rim) due to malign or benign disease. After physical examination, checking of inclusion/exclusion criteria, and after informed consent has been achieved, potential subjects will be enrolled in the study, and the investigational surgery will be performed during hospitalization. The devices, i.e. C-REX LapAid and C-REX DMH/DMHC (dual male handle/dual male catheter handle), included in C-REX Ring-locking Procedure are applied to the inside of the intestine and connected to catheters that allow monitoring of the anastomosis (if DMC is applied).

The healing period is expected to be approximately 10 ± 2 days. The short-term implant, i.e. the anastomotic ring, detaches via necrosis on the inner part of the intestinal surface and is expelled the natural way during hospitalization.

The subject can be discharged from the hospital when the short-term implant has been evacuated, and the subject has begun to eat and has normal bowel movements. The observation period lasts until 30 days after surgery. The subject then continues follow-up according to local routine.

QUALITY CONTROL Authorization to perform C-REX Ring-locking Procedure According to CarpoNovum's regulation (Document 0041: Procedure, Accreditation of Surgeons for Clinical Studies), clinical investigators must be authorized to conduct the C-REX Ring-locking Procedure with C-REX LapAid and C-REX DMH/DMHC by performing at least one surgery on pigs and at least one train-in surgery on patients with the person in charge of the study (Dr. Anders Grönberg). When the clinical investigator is authorized to perform the C-REX Ring-locking Procedure with C-REX LapAid System, he or she receives a certificate. This certificate could also admit the clinical investigator the right to authorize other surgeons to perform C-REX Ring-locking Procedure with C-REX LapAid and C-REX DMH/DMHC (i.e. to perform at least one operations on pigs and at least one train-in operations on patients with the authorized clinical investigator).

Monitoring To ensure that the study is appropriately conducted, a monitor appointed by the sponsor will visit the investigation site regularly and oversee the investigator's compliance with the CIP, perform source-data verification and report to the sponsor on the progress of the study.

Each investigation site and clinical investigator in the study will be monitored. On all occasions, the responsible monitor and/or the person in charge of the study will secure for example that:

  1. Compliance with CIP (clinical investigation plan) is maintained and any deviation from CIP is discussed with the clinical investigators, documented and reported to the sponsor; if the changes are significant, the competent authority and the ethical committee will be informed;
  2. The device is being used according to CIP, IB (investigator's brochure) and IFU (instructions for use), and if modifications are required either to the device or its method of use or to the CIP, this need shall be reported to the sponsor;
  3. Signed and dated informed consent forms have been obtained from each subject at the time of enrollment and before any study-related procedures are undertaken;
  4. The data in CRFs (case report forms) are complete, are recorded in a timely manner and are consistent with the source data;
  5. Traceability and device accountability of the investigational device are properly maintained;
  6. Maintenance and calibration of equipment relevant for assessment of the study is performed;
  7. Possible adverse events or device deficiencies have been properly documented and reported;
  8. Subjects withdrawal and/or non-compliance is documented and discussed with the clinical investigator and reported to the sponsor;
  9. Clinical investigators have and continue to have staff and facilities to conduct the study safely and effectively;
  10. Clinical investigators have and continue to have access to an adequate number of subjects and the investigational device to complete the study.

The responsible monitor will write a report after each visit to the medical institutions. The reports will be sent to the sponsor and the principal clinical investigators.

Documentation and data processing Medical record of subjects

The following information should be clearly documented in medical record of subjects:

  • That the subject is informed about the study and that the subject has signed the informed consent forms.
  • That the subject is participating in the study; the identification code for the subject, the name of the study, and the study number (i.e., CREX-003).
  • Which treatment the study refers to (i.e., C-REX Ring-locking Procedure with use of C-REX LapAid and C-REX DMH/DMHC).
  • Name of the principal clinical investigator.
  • All AEs (adverse events) and device deficiencies.

Document and data control Prior to commencement of the study, clinical investigators and their staff will be informed about CIP, CRFs and other study documents and procedures.

For each subject enrolled, regardless of medical device initiation, a CRF must be completed and signed by corresponding investigation personnel. This applies to those subjects who fail to complete the study. If a subject withdraws from the study, the reason must be noted on CRF.

Data and information of subjects derived from the study are considered as source data. To ensure that all data are complete and correct, source data verification (SDV) will be confirmed by the monitor.

Comments in CRF should be made with a ballpoint pen with permanent ink. If comments are missing in CRF, reasons for this must be stated. No questions, squares, fields or similar should be left without comments.

CRF entries and corrections will only be performed by investigational personnel, authorized by the principle clinical investigator. Errors should be crossed out but not obliterated, the correction inserted, and the change initialed and dated by the clinical investigator.

Then entries will be checked by the monitor and any errors or inconsistencies will be checked and corrected immediately.

The responsible clinical investigator is obliged to keep the subject identification lists with the subject's identification code and identity in a safe place at the investigation site (hospital), accessible only to the investigation personnel. These source data and subject identification lists will be saved for 10 years after the close of the study at the medical institution.

NUMBER OF SUBJECTS The aim of this study is to verify the novel device in clinical practise and for CE (Conformité Européenne) marking later. Since no control group is included, there is no need for power determinations.

Considering that similar anastomotic devices have been used in clinic for decades, 20 subjects will be included in The First Affiliated Hospital of Xiamen University.

STATISTICAL ANALYSIS OF VARIABLES Descriptive methods are used to analyze the data collected in the study. The incidences of anastomotic leakage and other AEs/device deficiencies are calculated.

Being tested
C-REX Ring-locking Procedure
Medical subject headings
Colonic Neoplasms, Colonic Polyps

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • C-REX Ring-locking ProcedureDevice

    The C-REX Ring-locking Procedure is a method based on adaptive anastomosis, in which intestinal ends adapt to each other after resection due to tumor, injury, or other disease.

    The investigational devices comprised of two components, i.e. C-REX LapAid and C-REX DMH/DMHC

Study groups in NCT03179358
Study groupRoleWhat they receive
C-REX groupExperimentalAfter resection of the disease in colon, the intestinal ends will be anastomosed by the investigational device, i.e. C-REX LapAid and C-REX DMH/DMHC included in the C-REX Ring-locking Procedure.
Receives: Device: C-REX Ring-locking Procedure

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Time to evacuation of the short-term implant

    The subject informs the clinical investigator and hand over the expelled short-term implant

    Measured: About 2 weeks after surgery

Secondary outcomes (7)
  1. Time to first intestinal sounds

    The subject informs the clinical investigator about when the intestine begin to murmur, and the clinical investigator will check the sound with a stethoscope.

    Measured: Up to 30 days after surgery

  2. Time to first passage of gas

    The subject informs the clinical investigator when it occurs.

    Measured: Up to 30 days after surgery

  3. Time to first defecation

    The subject informs the clinical investigator when it occurs.

    Measured: Up to 30 days after surgery

  4. Number of postoperative interventions related to the device

    The clinical investigator notes the interventions after surgery related to the use of device, for instance, CT scan, endoscopy examination and re-operation etc.

    Measured: Up to 30 days after surgery

  5. Integrity pressure

    To confirm that the two anastomotic rings are properly locked to each other, measure integrity pressure through catheters connected to DMC (if DMC is applied). By infusing air into the closed space adjacent to the anastomosis via on catheter and concomitantly camping the other three catheters. When the pressure in the closed space exceeds the contact-induced closure by the joined intestinal segments, the pressure abruptly dropped and is defined as integrity pressure.

    Measured: The operation day

  6. Post-operative X-ray examination

    The anastomosis could be examined through catheters connected to DMC (if DMC is applied) in case of suspect of anastomotic leakage. The integrity of anastomosis is examined by local infusion of water-soluble contract media through one of the catheters, and at the same time conduct X-ray examination. The contract media will leak from the closed space adjacent to the anastomosis if there is a anastomotic leakage.

    Measured: Up to 4 days after surgery

  7. Time of surgery

    The time to complete the operation.

    Measured: The operation day

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted7 Jun 2017
  2. Study start29 Sep 2016
  3. Primary completion10 Jun 2017
  4. Study completion10 Jun 2017

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
20 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03179358
Sponsor's protocol ID
CREX-003
Status last verified
Jan 2018
First submitted
28 May 2017
Last updated
17 Jan 2018
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing C-REX Ring-locking Procedure in people with Cancer Colon and Polyp of Colon, run by Carponovum AB at 1 site in China.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 16 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 17 Jan 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in China. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Time to evacuation of the short-term implant (time frame: About 2 weeks after surgery). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 Jan 2018.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in