Heart FailureNCT03280862
DANISH-CRT - Does Electric Targeted LV Lead Positioning Improve Outcome in Patients With Heart Failure and Prolonged QRS
A study testing Implantation of a Cardiac Resynchronisation Therapy (CRT) pacing device with or without Implanted Cardioverter Defibrillator in people with Heart Failure and Branch Block, Bundle, run by Aarhus University Hospital at 5 sites in Denmark.
Trial summary
Heart failure is a leading cause of morbidity and mortality. Cardiac resynchronization therapy (CRT) is a well-established treatment for patients with symptomatic heart failure in spite of optimised medical treatment (OMT), reduced left ventricular pump function with left ventricular ejection fraction (LVEF) ≤ 35% and… Read more about this study
- Who is it for?
- Ages 40 years and older
- Conditions the study is for
- Heart Failure, Branch Block, Bundle
- What is being tested?
- Implantation of a Cardiac Resynchronisation Therapy (CRT) pacing device with or without Implanted Cardioverter Defibrillator
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 1,000 participants
- Where
- 5 sitesDenmark
- Study dates
- 20 Mar 2018to 27 Feb 2026
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 40 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Heart Failure, NYHA II, III, outpatient IV
- LVEF ≤35% measured by echocardiography
- Optimal medical treatment for heart failure
- Bundle Branch Block
- Indication for primary CRT-D or CRT-P implantation or upgrade from RV pacing (pacemaker or ICD) to CRT-D or CRT-P
- Ischemic heart disease (IHD) or non-IHD
Show all 9Show fewer
- Sinus rhythm or atrial fibrillation
- Life expectancy >2 years
- Signed informed consent
Who cannot join
- NYHA class I
- Acute mycardial infarction (AMI) within the latest 3 months
- Coronary artery bypass graft (CABG) within the latest 3 months
- Life expectancy <2 years
- Participation in another clinical trial of experimental treatment
- Contraindication for establishing implantable device treatment
- Previously implanted CRT system
- Does not wish to participate
Trial locations and contacts
5 sites in 1 country.
5 sites in 1 country
Denmark5 sites
Aalborg University Hospital
Aalborg, 9000
Aarhus University Hospital
Aarhus, 8200
Rigshospitalet
Copenhagen, 2100
Gentofte University Hospital
Gentofte Municipality, 2900
Odense University Hospital
Odense, 5000
About this study
Official title: Does Targeted LV Lead Positioning Towards Latest Local Electric Activation at CRT Implantation Reduce Incidence of the Combined Endpoint "Death or Non-planned Hospitalisation for Heart Failure (HF)" in Patients With HF and Prolonged QRS
Heart failure is a leading cause of morbidity and mortality. Cardiac resynchronization therapy (CRT) is a well-established treatment for patients with symptomatic heart failure in spite of optimised medical treatment (OMT), reduced left ventricular pump function with left ventricular ejection fraction (LVEF) ≤ 35% and prolonged activation of the ventricles (bundle branch block: BBB). CRT is established by implanting an advanced pacemaker system with three leads in the right atrium, right ventricle, and in the coronary sinus (CS) for pacing the left ventricle (LV), and often is combined with an implantable defibrillator (ICD) function. On average, CRT treatment improves longevity, quality of life and functional class, and reduces heart failure symptoms. Thus, at present, CRT is indicated for heart failure patients on OMT with BBB or chronic right ventricular (RV) pacing.
It is, however, a significant problem that 30-40% of CRT patients do not benefit measurably - showing symptomatic improvement or improved cardiac pump function - from this therapy (socalled non-responders). LV lead placement is one of the major determinants of beneficial effect from CRT.
Read more
Observational studies and three randomised trials with small sample sizes indicate that targeted placement of the LV lead towards a late activated segment of the LV may be associated with improved outcome. Based on this literature, some physicians already search for late activation when positioning the LV lead. However, such a strategy was never tested in a controlled trial with a sample size sufficient to investigate important clinical outcomes. Detailed mapping for a late activation may increase operating times and infection risk, result in use of more electrodes and wires, thereby increasing costs, and increase radiation exposure for patient and staff. Placement of the LV lead in late activated areas close to myocardial scar may even result in higher risk of arrhythmia and death.
At present, it is completely unsettled whether targeted positioning of the LV lead to the latest electrically activated area of LV is superior to contemporary standard CRT with regard to improving prognosis for patients with heart failure and BBB.
The present study aims to test whether targeting the placement of the LV lead towards the latest electrically activated segment in the coronary sinus branches improves outcome as compared with standard LV lead implant in a patient population with heart failure and CRT indication.
- Conditions
- Heart Failure, Branch Block, Bundle
- Being tested
- Implantation of a Cardiac Resynchronisation Therapy (CRT) pacing device with or without Implanted Cardioverter Defibrillator
- Keywords
- Heart Failure, Branch Block, Cardiac Resynchronization Therapy
- Medical subject headings
- Heart Failure, Bundle-Branch Block
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Implantation of a Cardiac Resynchronisation Therapy (CRT) pacing device with or without Implanted Cardioverter DefibrillatorDevice
Implantation of CRT-P/-D device
| Study group | Role | What they receive |
|---|---|---|
| Control | Active comparator | Implantation of a Cardiac Resynchronisation Therapy (CRT) pacing device with or without Implanted Cardioverter Defibrillator with the LV lead positioned preferentially in a posterolateral, non-apical position Receives: Device: Implantation of a Cardiac Resynchronisation Therapy (CRT) pacing device with or without Implanted Cardioverter Defibrillator |
| Intervention | Experimental | Implantation of a Cardiac Resynchronisation Therapy (CRT) pacing device with or without Implanted Cardioverter Defibrillator with the LV lead positioned according to the latest electrical activation in the CS Receives: Device: Implantation of a Cardiac Resynchronisation Therapy (CRT) pacing device with or without Implanted Cardioverter Defibrillator |
What is being measured
The primary outcome is the main question the study is designed to answer.
Death or first non-planned hospitalisation for heart failure
Time to death or first non-planned hospitalisation for heart failure
Measured: All patients will be followed until the last included patient has been followed for two years
Secondary outcomes (30)
Death
Time to death
Measured: All patients will be followed until the last included patient has been followed for two years
Non-planned hospitalisation for heart failure
Time to first non-planned hospitalisation for heart failure
Measured: All patients will be followed until the last included patient has been followed for two years
Sudden death
Time to sudden death
Measured: All patients will be followed until the last included patient has been followed for two years
Cardiac death
Time to cardiac death
Measured: All patients will be followed until the last included patient has been followed for two years
Clinical response
Increase in New York Heart Association (NYHA) class (≥1 class from baseline) or improved walking distance by six-minute walk test (6MWT) (≥10% from baseline)
Measured: Follow-up at 3, 6, 12, 24 and 48 months
Quality of Life (QoL)
Changes in score from baseline to follow-up
Measured: Follow-up at 6, 12, 24 and 48 months
Patient Reported Outcomes (PROs)
Changes in score from baseline to follow-up
Measured: Follow-up at 6, 12, 24 and 48 months
Echocardiographic measures of LV function
Changes from baseline to follow-up in left ventricular ejection fraction (%)
Measured: Follow-up at 6, 12, 24 and 48 months
Time to first appropriate ICD Therapy
Time to first appropriate ICD therapy (antitachycardia pacing (ATP) or shock therapy)
Measured: All patients will be followed until the last included patient has been followed for two years
Time to first inappropriate ICD Therapy
Time to first inappropriate ICD therapy (antitachycardia pacing (ATP) or shock therapy)
Measured: All patients will be followed until the last included patient has been followed for two years
Numbers of appropriate ICD Therapies
Numbers of appropriate ICD therapies (antitachycardia pacing (ATP) or shock therapy)
Measured: All patients will be followed until the last included patient has been followed for two years
Numbers of inappropriate ICD Therapies
Numbers of inappropriate ICD therapies (antitachycardia pacing (ATP) or shock therapy)
Measured: All patients will be followed until the last included patient has been followed for two years
Ventricular tachycardia (VT)/ventricular fibrillation (VF)
Time to first episode of VT/VF
Measured: All patients will be followed until the last included patient has been followed for two years
Persistent atrial fibrillation
Recorded by the implanted device
Measured: All patients will be followed until the last included patient has been followed for two years
Any atrial fibrillation
>30 seconds recorded by the implanted device
Measured: All patients will be followed until the last included patient has been followed for two years
Implantation time
Procedure time at implantation
Measured: 0-6 hours, assessed at completion of implantation procedure
Fluoroscopy time
Fluoroscopy time at implantation in minutes
Measured: 0-120 minutes, assessed at completion of implantation procedure
Fluoroscopy dose
Fluoroscopy dose at implantation in mGy
Measured: Assessed <24 hours after implantation initiation
Equipment used at implantation
Number of LV leads (0-5) used at implantation
Measured: Assessed <24 hours after implantation initiation
Device-related outcomes
Periprocedural: lead re-operation, pneumothorax, hemothorax, pericardial bleeding/tamponade and later (30 days post implantation): LV lead re-operation, device replacement due to battery depletion, and infection requiring extraction
Measured: All patients will be followed until the last included patient has been followed for two years
Battery replacements
Number of device replacements during the study period due to battery depletion
Measured: All patients will be followed until the last included patient has been followed for two years
Battery longevity estimate
Measured by actual device battery longevity + estimated remaining device battery longevity as reported by the device at last study follow-up
Measured: All patients will be followed until the last included patient has been followed for two years
QRS complex width
Changes in the ECG parameter QRS complex width during follow-up
Measured: All patients will be followed until the last included patient has been followed for two years
QRS complex morphology
Changes in the ECG parameter QRS complex morphology during follow-up
Measured: All patients will be followed until the last included patient has been followed for two years
Predictive value of P-wave
Predictive value of the baseline ECG parameter P-wave on clinical outcome measures in the entire cohort and between the two treatment groups
Measured: All patients will be followed until the last included patient has been followed for two years
Predictive value of QRS complex width
Predictive value of the baseline ECG parameter QRS complex width on clinical outcome measures in the entire cohort and between the two treatment groups
Measured: All patients will be followed until the last included patient has been followed for two years
Predictive value of QRS complex morphology
Predictive value of the baseline ECG parameter QRS complex morphology on clinical outcome measures in the entire cohort and between the two treatment groups
Measured: All patients will be followed until the last included patient has been followed for two years
Changes in cardiac chamber dimensions
Volumes of cardiac chambers (left ventricle, left atrium, right ventricle, right atrium) measured by echocardiography and cardiac CT during follow-up in the entire cohort and between the two treatment groups
Measured: All patients will be followed until the last included patient has been followed for two years
Changes in left ventricular ejection fraction LVEF
Changes in cardiac chamber function measured by echocardiography and cardiac CT during follow-up in the entire cohort and between the two treatment groups
Measured: All patients will be followed until the last included patient has been followed for two years
Changes in right ventricular ejection fraction RVEF
Changes in cardiac chamber function measured by echocardiography and cardiac CT during follow-up in the entire cohort and between the two treatment groups
Measured: All patients will be followed until the last included patient has been followed for two years
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted13 Sep 2017
- Study start20 Mar 2018
- Primary completion27 Feb 2026
- Study completion27 Feb 2026
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (2)Papers the sponsor has linked to this study.
- Other trials for Heart FailureStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Model description
- Double-blind randomised controlled trial. Patients are included and randomised 1:1 into two groups for implantation of either 1. a CRT-D/P device with the LV lead positioned according to the latest electrical activation in the CS (intervention group) or 2. a CRT-D/P device with the LV lead positioned preferentially in a posterolateral, non-apical position (control group)
- Masking
- Quadruple blind
- Who is masked
- Participant, Care provider, Investigator, Outcomes assessor
- Enrolment
- 1,000 participants (actual)
Sponsor and investigators
- Lead sponsor
- Aarhus University Hospital
- Sponsor type
- University, hospital or other
- Collaborators
- Aalborg University Hospital, Odense University Hospital, Copenhagen University Hospital, Rigshospitalet, Gentofte University Hospital
- Responsible party
- Principal investigator, Jens Cosedis Nielsen, Aarhus University Hospital
- Investigators
- Jens C Nielsen, Principal investigator, Aarhus University Hospital
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03280862
- Sponsor's protocol ID
- 1-10-72-330-16
- Status last verified
- May 2026
- First submitted
- 8 Jun 2017
- Last updated
- 29 May 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
Nielsen JC, Svendsen JH, Johansen JB, Larsen JM, Larroude CE, Poulsen SH, Eiskjaer H, Norgaard BL, Risum N, Kober L, Kristensen J, Ovrehus K, Sommer AM, Schou M, Sogaard P, Poulsen MK, Kofoed KF, Hansen TF, Graff C, Skals RG, Frausing MHJP, Frandsen EA, Jensen JM, Vinther M, Jensen HK, Haarbo J, Zaremba T, Viezelis M, Philbert B, Hjort J, Gerdes C, Kronborg MB; DANISH-CRT Trial Investigators. Targeted left ventricular lead placement in biventricular pacing for heart failure: a national, multicentre, double-blind, randomised controlled trial in Denmark. Lancet. 2026 Aug 31:S0140-6736(26)01597-7. doi: 10.1016/S0140-6736(26)01597-7. Online ahead of print.
PubMed 42673980Kronborg MB, Frausing MHJP, Svendsen JH, Johansen JB, Riahi S, Haarbo J, Poulsen SH, Eiskjaer H, Kober L, Ovrehus K, Sommer AM, Schou M, Norgaard BL, Risum N, Poulsen MK, Sogaard P, Sandgaard N, Kofoed KF, Hansen TF, Graff C, Pedersen SS, Skals RG, Nielsen JC. Does targeted positioning of the left ventricular pacing lead towards the latest local electrical activation in cardiac resynchronization therapy reduce the incidence of death or hospitalization for heart failure? Am Heart J. 2023 Sep;263:112-122. doi: 10.1016/j.ahj.2023.05.011. Epub 2023 May 21.
PubMed 37220821
Study at a glance
From the registry record, last updated by the sponsor on 29 May 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Does Targeted LV Lead Positioning Towards Latest Local Electric Activation at CRT Implantation Reduce Incidence of the Combined Endpoint "Death or Non-planned Hospitalisation for Heart Failure (HF)" in Patients With HF and Prolonged QRS
- ClinicalTrials.gov ID
- NCT03280862
- Acronym / sponsor ID
- 1-10-72-330-16
- Conditions
- Heart Failure, Branch Block, Bundle
- Keywords
- Heart Failure, Branch Block, Cardiac Resynchronization Therapy
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 1,000 participants (actual)
- Lead sponsor
- Aarhus University HospitalUniversity, hospital or other
- Collaborators
- Aalborg University Hospital, Odense University Hospital, Copenhagen University Hospital, Rigshospitalet, Gentofte University Hospital
- Study start
- 20 Mar 2018 (actual)
- Primary completion
- 27 Feb 2026 (actual)
- Study completion
- 27 Feb 2026 (actual)
- First posted
- 13 Sep 2017 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Heart failure is a leading cause of morbidity and mortality. Cardiac resynchronization therapy (CRT) is a well-established treatment for patients with symptomatic heart failure in spite of optimised medical treatment (OMT), reduced left ventricular pump function with left ventricular ejection fraction (LVEF) ≤ 35% and prolonged activation of the ventricles (bundle branch block: BBB). CRT is established by implanting an advanced pacemaker system with three leads in the right atrium, right ventricle, and in the coronary sinus (CS) for pacing the left ventricle (LV), and often is combined with an implantable defibrillator (ICD) function. On average, CRT treatment improves longevity, quality of life and functional class, and reduces heart failure symptoms. Thus, at present, CRT is indicated for heart failure patients on OMT with BBB or chronic right ventricular (RV) pacing.
It is, however, a significant problem that 30-40% of CRT patients do not benefit measurably - showing symptomatic improvement or improved cardiac pump function - from this therapy (socalled non-responders). LV lead placement is one of the major determinants of beneficial effect from CRT.
Observational studies and three randomised trials with small sample sizes indicate that targeted placement of the LV lead towards a late activated segment of the LV may be associated with improved outcome. Based on this literature, some physicians already search for late activation when positioning the LV lead. However, such a strategy was never tested in a controlled trial with a sample size sufficient to investigate important clinical outcomes. Detailed mapping for a late activation may increase operating times and infection risk, result in use of more electrodes and wires, thereby increasing costs, and increase radiation exposure for patient and staff. Placement of the LV lead in late activated areas close to myocardial scar may even result in higher risk of arrhythmia and death.
At present, it is completely unsettled whether targeted positioning of the LV lead to the latest electrically activated area of LV is superior to contemporary standard CRT with regard to improving prognosis for patients with heart failure and BBB.
The present study aims to test whether targeting the placement of the LV lead towards the latest electrically activated segment in the coronary sinus branches improves outcome as compared with standard LV lead implant in a patient population with heart failure and CRT indication.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Quadruple blind (participant, care provider, investigator, outcomes assessor)
- Number of arms
- 2
- Model description
- Double-blind randomised controlled trial. Patients are included and randomised 1:1 into two groups for implantation of either 1. a CRT-D/P device with the LV lead positioned according to the latest electrical activation in the CS (intervention group) or 2. a CRT-D/P device with the LV lead positioned preferentially in a posterolateral, non-apical position (control group)
| Arm | Type | Receives |
|---|---|---|
| Control | Active comparator | Device: Implantation of a Cardiac Resynchronisation Therapy (CRT) pacing device with or without Implanted Cardioverter DefibrillatorImplantation of a Cardiac Resynchronisation Therapy (CRT) pacing device with or without Implanted Cardioverter Defibrillator with the LV lead positioned preferentially in a posterolateral, non-apical position |
| Intervention | Experimental | Device: Implantation of a Cardiac Resynchronisation Therapy (CRT) pacing device with or without Implanted Cardioverter DefibrillatorImplantation of a Cardiac Resynchronisation Therapy (CRT) pacing device with or without Implanted Cardioverter Defibrillator with the LV lead positioned according to the latest electrical activation in the CS |
Who may qualify
- Ages
- 40 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (9 listed)
- Heart Failure, NYHA II, III, outpatient IV
- LVEF ≤35% measured by echocardiography
- Optimal medical treatment for heart failure
- Bundle Branch Block
- Indication for primary CRT-D or CRT-P implantation or upgrade from RV pacing (pacemaker or ICD) to CRT-D or CRT-P
Key exclusion criteria (8 listed)
- NYHA class I
- Acute mycardial infarction (AMI) within the latest 3 months
- Coronary artery bypass graft (CABG) within the latest 3 months
- Life expectancy <2 years
- Participation in another clinical trial of experimental treatment
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Implantation of a Cardiac Resynchronisation Therapy (CRT) pacing device with or without Implanted Cardioverter DefibrillatorImplantation of CRT-P/-D device | Device | Control, Intervention |
Primary outcome
Death or first non-planned hospitalisation for heart failure
Time frame: All patients will be followed until the last included patient has been followed for two years
Time to death or first non-planned hospitalisation for heart failure
30 secondary outcomes
Death
Time frame: All patients will be followed until the last included patient has been followed for two years
Non-planned hospitalisation for heart failure
Time frame: All patients will be followed until the last included patient has been followed for two years
Sudden death
Time frame: All patients will be followed until the last included patient has been followed for two years
Cardiac death
Time frame: All patients will be followed until the last included patient has been followed for two years
Clinical response
Time frame: Follow-up at 3, 6, 12, 24 and 48 months
Quality of Life (QoL)
Time frame: Follow-up at 6, 12, 24 and 48 months
Patient Reported Outcomes (PROs)
Time frame: Follow-up at 6, 12, 24 and 48 months
Echocardiographic measures of LV function
Time frame: Follow-up at 6, 12, 24 and 48 months
Time to first appropriate ICD Therapy
Time frame: All patients will be followed until the last included patient has been followed for two years
Time to first inappropriate ICD Therapy
Time frame: All patients will be followed until the last included patient has been followed for two years
Numbers of appropriate ICD Therapies
Time frame: All patients will be followed until the last included patient has been followed for two years
Numbers of inappropriate ICD Therapies
Time frame: All patients will be followed until the last included patient has been followed for two years
Ventricular tachycardia (VT)/ventricular fibrillation (VF)
Time frame: All patients will be followed until the last included patient has been followed for two years
Persistent atrial fibrillation
Time frame: All patients will be followed until the last included patient has been followed for two years
Any atrial fibrillation
Time frame: All patients will be followed until the last included patient has been followed for two years
Implantation time
Time frame: 0-6 hours, assessed at completion of implantation procedure
Fluoroscopy time
Time frame: 0-120 minutes, assessed at completion of implantation procedure
Fluoroscopy dose
Time frame: Assessed <24 hours after implantation initiation
Equipment used at implantation
Time frame: Assessed <24 hours after implantation initiation
Device-related outcomes
Time frame: All patients will be followed until the last included patient has been followed for two years
Battery replacements
Time frame: All patients will be followed until the last included patient has been followed for two years
Battery longevity estimate
Time frame: All patients will be followed until the last included patient has been followed for two years
QRS complex width
Time frame: All patients will be followed until the last included patient has been followed for two years
QRS complex morphology
Time frame: All patients will be followed until the last included patient has been followed for two years
Predictive value of P-wave
Time frame: All patients will be followed until the last included patient has been followed for two years
Predictive value of QRS complex width
Time frame: All patients will be followed until the last included patient has been followed for two years
Predictive value of QRS complex morphology
Time frame: All patients will be followed until the last included patient has been followed for two years
Changes in cardiac chamber dimensions
Time frame: All patients will be followed until the last included patient has been followed for two years
Changes in left ventricular ejection fraction LVEF
Time frame: All patients will be followed until the last included patient has been followed for two years
Changes in right ventricular ejection fraction RVEF
Time frame: All patients will be followed until the last included patient has been followed for two years
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 29 May 2026.
- Derived from this study: PubMed 42673980Nielsen JC, Svendsen JH, Johansen JB, Larsen JM, Larroude CE, Poulsen SH, Eiskjaer H, Norgaard BL, Risum N, Kober L, Kristensen J, Ovrehus K, Sommer AM, Schou M, Sogaard P, Poulsen MK, Kofoed KF, Hansen TF, Graff C, Skals RG, Frausing MHJP, Frandsen EA, Jensen JM, Vinther M, Jensen HK, Haarbo J, Zaremba T, Viezelis M, Philbert B, Hjort J, Gerdes C, Kronborg MB; DANISH-CRT Trial Investigators. Targeted left ventricular lead placement in biventricular pacing for heart failure: a national, multicentre, double-blind, randomised controlled trial in Denmark. Lancet. 2026 Aug 31:S0140-6736(26)01597-7. doi: 10.1016/S0140-6736(26)01597-7. Online ahead of print.
- Derived from this study: PubMed 37220821Kronborg MB, Frausing MHJP, Svendsen JH, Johansen JB, Riahi S, Haarbo J, Poulsen SH, Eiskjaer H, Kober L, Ovrehus K, Sommer AM, Schou M, Norgaard BL, Risum N, Poulsen MK, Sogaard P, Sandgaard N, Kofoed KF, Hansen TF, Graff C, Pedersen SS, Skals RG, Nielsen JC. Does targeted positioning of the left ventricular pacing lead towards the latest local electrical activation in cardiac resynchronization therapy reduce the incidence of death or hospitalization for heart failure? Am Heart J. 2023 Sep;263:112-122. doi: 10.1016/j.ahj.2023.05.011. Epub 2023 May 21.
- Individual participant dataSharing planned: No
Related trials for Heart Failure
RecruitingPhase 2/3
Efficacy, Safety, and Pharmacokinetics of Vericiguat in Pediatric Participants With Heart Failure Due to Left Ventricular Systolic Dysfunction (MK-1242-036)
Heart Failure, Left Ventricular Systolic Dysfunction
RecruitingPhase 1/2
HS235 Study in Overweight and Obese Participants With Combined Pre and Post-Capillary Pulmonary Hypertension Due to Heart Failure With Preserved Ejection Fraction
Pulmonary Hypertension, Heart Failure With Preserved Ejection Fraction
Active, not recruiting
Heart Failure Patient Management and Interventions Using Continuous Patient Monitoring Outside Hospitals and Real-world Data
Chronic Heart Failure, Heart Transplant Recipient
Enrolling by invitationObservational study
Multi-Scale Analysis of Phenotypes in Heart Failure (MAP-HEART)
Heart Failure
Not yet recruitingObservational study
Real-world Effectiveness and Safety of Savagen (Sacubitril/Valsartan) in Malaysian HFrEF Patients
Heart Failure With Reduced Ejection Fraction (HFrEF), Heart Failure
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Jens C Nielsen principal investigator
Aarhus University Hospital
5 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Implantation of a Cardiac Resynchronisation Therapy (CRT) pacing device with or without Implanted Cardioverter Defibrillator in people with Heart Failure and Branch Block, Bundle, run by Aarhus University Hospital at 5 sites in Denmark.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 9 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 29 May 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 5 sites in Denmark. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Death or first non-planned hospitalisation for heart failure (time frame: All patients will be followed until the last included patient has been followed for two years). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT03280862, which also lists 2 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 29 May 2026.