SarcopeniaNCT03308903
Use of the Sit-To-Stand Task as a Screening Tool for Sarcopenia The
An observational study of Sarcopenia, run by University of Bedfordshire at 1 site in United Kingdom.
Trial summary
A common condition associated with ageing is sarcopenia, which is a progressive decrease in muscle mass. Sarcopenia is associated with adverse outcomes including increased mortality, and places a major burden on healthcare spending, with the annual cost of sarcopenia in the United States exceeding that of osteoporosis… Read more about this study
- Who is it for?
- Ages 65 years and olderHealthy volunteers can take part
- Conditions the study is for
- Sarcopenia
- What is being tested?
- DEXA scan
- How many people
- 40 participants
- Where
- 1 siteUnited Kingdom
- Study dates
- 22 Jan 2018to 31 Mar 2019
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 65 years and older
- All sexes
- Healthy volunteers accepted
- Older adult
Study population: Community-dwelling people aged 65 years and over with no musculoskeletal problems.
Who may be able to join
- Male or female
- Community-dwelling adults
- Aged 65+ years
Who cannot join
- Cardiovascular and/or respiratory problems
- High blood pressure (140/90mmHG or higher)
- Low blood pressure (90/60mmHg or lower)
- A diagnosis of arthritis and/or osteoporosis
- Had a musculoskeletal injury within the last twelve months
- Had an X-ray examination with contrast medium in the 3 weeks prior to the DEXA scan (if this does apply to the participant, the date of which they will participate will be delayed until 3 weeks after the date of their contrast scan)
- Recently had a Nuclear Medicine diagnostic or therapy investigation, depending on its nature (this will be referred to the Medical Physics Expert to determine if and when the participant can receive a DEXA scan for this study)
- Any significant internal metalwork or irremovable external metalwork.
Trial locations and contacts
1 site in 1 country.
United Kingdom1 site, 1 recruiting
- Recruiting
University of Bedfordshire
Bedford, Bedfordshire, MK41 9EA
David Hewson, PhD, 0044 7525 616645, david.hewson@beds.ac.uk
About this study
Official title: Can the Sit-to-Stand Test be Used as a Screening Tool to Detect Sarcopenia in Community-dwelling Older People?
A common condition associated with ageing is sarcopenia, which is a progressive decrease in muscle mass. Sarcopenia is associated with adverse outcomes including increased mortality, and places a major burden on healthcare spending, with the annual cost of sarcopenia in the United States exceeding that of osteoporosis and hip fracture. In the UK, the prevalence of sarcopenia in community-dwelling older people has been estimated at 5% for men and 8% for women. Current guidelines for sarcopenia diagnosis require muscle mass to be measured using costly devices such as Dual Energy X-ray Absorptiometry (DXA) and Magnetic Resonance Imaging (MRI). Previous research has found strong relationships between the sit-to-stand (STS) test and both muscle mass and muscle strength. This pilot study aims to examine this relationship in community-dwelling older people to develop predictive equations for initial screening of sarcopenia.
Forty subjects will be tested using the diagnostic criteria developed by the European Working Group on Sarcopenia in Older People (EWGSOP). Muscle mass will be measured using the DXA and diagnostic ultrasound. Muscle strength will be measured using isokinetic dynamometer, handgrip dynamometry, and hand-held dynamometry. Functional performance will be measured using the Timed-up-and-Go and gait velocity, and the STS. Subjects will perform two variants of the STS; the five times STS (5STS), which requires subjects to perform five consecutive STS movements as quick as possible, and the 30-second STS (30STS), which requires subjects to perform as many STS movements as possible in 30 seconds. All testing will be completed in a single session lasting 90 minutes for each subject. Testing will be performed at the University of Bedfordshire Polhill Campus. Subject recruitment will be recruited using advertisement posters and word of mouth.
Read the detailed description
Loss of function and mobility becomes an increasing concern as we age. Life expectancy is continuing to increase, which in turn leads to age-related diseases and syndromes becoming more common, complex and costly. Sarcopenia is the deficiency of muscle and this refers to the gradual loss of skeletal muscle mass and strength that occurs with advancing age This age-related disease is now understood as a major clinical problem for the elderly and it is becoming a public health issue in today's society.
The European Working Group on Sarcopenia in Older People (EWGSOP) has developed a clinical and practical definition and a diagnostic criterion for age-related sarcopenia. They define sarcopenia as "a syndrome characterised by progressive and generalised loss of skeletal muscle mass and strength with a risk of adverse outcomes". The EWGSOP further develop their definition of sarcopenia into two different categories and three different stages. The two categories are known as primary sarcopenia and secondary sarcopenia. Primary or age-related sarcopenia is when there is no other cause evident except ageing. Whereas secondary sarcopenia is when there are one or more other causes, such as activity-related, disease-related or nutrition-related. The three stages of sarcopenia reflect the severity of the condition; these are known as presarcopenia, sarcopenia and severe sarcopenia. The presarcopenia stage is described as having low muscle mass, without influencing muscle strength or physical performance. The sarcopenia stage is indicated by again having low muscle mass plus either having low muscle strength or poor physical performance. The severe sarcopenia stage is characterised by meeting all three criteria of the definition; low muscle mass, low muscle strength and poor physical performance. The EWGSOP specify that the measurable variables of sarcopenia are muscle mass, muscle strength and physical performance. The challenge they raised is the difficulty determining which methods are best to accurately measure these variables.
The EWGSOP indicate that muscle mass is best measured using body imaging techniques such as magnetic resonance imaging (MRI) or computer-tomography (CT). Both MRI and CT scans are known as the gold standards for measuring muscle mass within research. However, they are costly procedures that are not always freely available. Muscle mass can also be measured through dual energy X-ray absorptiometry (DEXA), for determining the presence of and formulating a diagnosis of sarcopenia. DEXA is based on the measurement of X-ray transmission crossing human tissues. The radiation energies produced by the DEXA are variably attenuated, either scattered or absorbed, by the anatomical structures within the body, dependent on the intensity of the energy and the density and thickness of the human tissues. DEXA enables measurements of fat mass (FM), lean mass (LM) and bone mineral content (BMC) and can assess body masses and bone mineral density (BMD) on a regional and a whole-body basis, whilst exposing only minimal radiation to the patient. According to the EWGSOP, DEXA is a preferred alternative method for measuring muscle mass within research and clinical use. However, it has been reported that measures of muscle mass from DEXA scans do not seem to be accurate, with a site-specific assessment of loss of muscle mass, using ultrasound-based assessment suggested. Ultrasound has been reported to be an effective and non-invasive tool to determine muscle wasting, potentially leading to an earlier and more accurate detection of sarcopenia.
Measures of muscle mass are not as good a predictor of physical capability as muscle strength. Lower limb muscle strength is more relevant for gait and physical function than upper limb muscle strength. However, the EWGSOP recognise handgrip strength as the most widely used method for measuring muscle strength to screen for sarcopenia. Handgrip strength is strongly related with lower extremity muscle power, knee extension torque and calf cross-sectional muscle area. Consequently, it has been documented that muscle power deteriorates earlier and quicker than muscle strength in older populations. Therefore, a measure of muscle power could be more beneficial in the diagnosis of sarcopenia as older people lose power quicker than they do strength. Isokinetic dynamometers (IKD) are a commonly used tool and are recognised as a gold standard measure of muscle power and strength. IKD's measure force dynamically through a specified range of motion whilst allowing the velocity of the movement to be controlled and measured. It is recognised as a popular method to assess muscle function in both clinical and research settings. However, due to IKD's not being portable and are not always accessible, there has been a rise in the use of hand-held dynamometry (HHD) to assess isometric muscle strength. It has been reported that HHD is a simple and inexpensive and a reliable and valid assessment tool for measuring strength, particularity in older adults. The use of isometric strength testing may be more suitable for older adults if there is a limited range of joint motion and if joint pain is prevalent, concentric actions may be challenging.
The importance of using physical performance measures within clinical geriatrics as well as ageing research has also been documented. There are many tests of physical performance that have been validated and are widely used. The EWGSOP identified popular methods for evaluating physical performance. These include the Short Physical Performance Battery (SPPB), usual gait speed (GS), the timed get-up-and-go (TUG) test and the stair climb power test. The ability to rise from a chair has been used in clinical evaluations and on-going assessments for decades. This everyday task was standardised and developed into the 'timed-stands' test. This test was initially designed to measure functional strength of the lower extremities as participants completed 10 timed-stands. Variations of this sit-to-stand (STS) task have evolved and now one of the most commonly used tools for clinical evaluation of physical performance is the Five-Times-Sit-To-Stand (5STS) test. The 5STS, requires the participant to stand up and sit down from a chair five times, with performance taken as the time to complete the test. The STS task was modified further, with a standardised 'time' protocol of 30 seconds (30sSTS), requiring the participant to stand up and sit down as many times as possible within 30 seconds. They reasoned the use of the 30sSTS instead of participants performing a predetermined number of repetitions (e.g. 5STS, 10STS) to assess a wider range of ability. Moreover, the 5STS and potentially even the 10STS can be recorded as the participant performs the 30sSTS. In addition to functional performance, the STS task could also be used to estimate muscle power and even muscle mass. In a recent study, an accurate estimation of lower-limb muscle power was obtained using a simple regression equation in which only body weight and the number of STS performed in 20 seconds, of a 30-second trial were used. Another study had also reported a good estimation of muscle mass obtained from an MRI, again using a simple regression equation in which only three basic variables were used, namely leg length, body mass and the time taken for a single STS movement.
Research Aim The aim of this study is to validate the use of the Sit-To-Stand task as a measure of muscle mass, muscle strength and power and physical performance in screening for sarcopenia compared to gold standard measures, in older adults aged 65 years and over.
Research Objectives
- Suitability of the Sit-To-Stand task as a measure of muscle mass in comparison to the gold standard equivalents, the dual energy x-ray absorptiometry scan and diagnostic ultrasound.
- Suitability of the Sit-To-Stand task as a measure of muscle strength and power in comparison to the gold standard equivalents, the isokinetic dynamometer the hand-grip strength dynamometer and the hand-held dynamometer.
- Suitability of the Sit-To-Stand task as a measure of physical performance in comparison to other well used physical function tests, the Timed-Up-and-Go and gait.
- Conditions
- Sarcopenia
- Being tested
- DEXA scan
- Medical subject headings
- Sarcopenia
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
DEXA scanDiagnostic test
The participant will undergo a whole-body DEXA (DEXA; GE Medical Systems, Chalfont St Giles, UK) scan, lasting approximately 5 minutes. This scan will produce body composition data, including estimates of lean body mass (LBM), appendicular lean mass (aLM) and body fat percentage (BF%).
What is being measured
The primary outcome is the main question the study is designed to answer.
Muscle mass measurement using dual X-ray absorptiometry
The participant will undergo a whole-body DEXA (DEXA; GE Medical Systems, Chalfont St Giles, UK) scan, lasting approximately 5 minutes. This scan will produce body composition data, including M and body fat percentage (BF%). For the purpose of this study, aLM values will be calculated in relation to height (sum of LBM in the arms and legs, scaled to height) (aLM/ht²).
Measured: 5 minutes
Secondary outcomes (8)
Hip and knee flexion and extension and ankle plantarflexion and dorsiflexion of both lower extremities on the Biodex System 3 Isokinetic Dynamometer
Participants will perform two sets of five repetitions of hip and knee flexion and extension and ankle plantarflexion and dorsiflexion of both lower extremities on the Biodex System 3 Isokinetic Dynamometer (IKD) (Suffolk, UK), with a 2-minute rest period between sets. The angular velocity of the IKD will be set at 60º/s.
Measured: 5 minutes
Five times sit to stand test
Participants will sit in a straight back chair with a solid seat that is 16" high. Participants will have their arms folded across their chest. They will then stand up and sit down as quickly as possible five times, keeping their arms folded across their chest. The test is measured with a stopwatch and is completed when the participant stands for the 5th time.
Measured: 5 minutes
Diagnostic ultrasound
Sonographic estimates of LBM will be measured using a diagnostic ultrasound. Muscle thickness measurements will be taken from both arms and legs of the participants.
Measured: 5 minutes
Grip strength
A measure of handgrip strength will be taken using the JAMAR PLUS + (Patterson Medical, IL, USA) of both the participant's upper extremities. Measures will be taken twice with a 2-minute rest period between trials. This requires the participant to exert their maximal grip in an isometric contraction.
Measured: 5 minutes
Handheld dynamometer assessment of muscle strength
Measures of isometric muscle strength will be measured using the hand-held dynamometer (HHD). Measures will be taken from the hip flexors, quadriceps, hamstrings, gastroc-soleus complex and tibialis anterior of both lower extremities.
Measured: 5 minutes
Timed Up and Go test
The participant sits on a standard armchair, placing his/her back against the chair and resting his/her arms chair's arms. The participant is instructed to use a comfortable and safe walking speed. The participant walks to a line that is 3 meters away, turns around at the line, walks back to the chair, and sits down. The test ends when the patient's buttocks touch the seat.
A stopwatch is used to time the test (in seconds).
Measured: 2 minutes
30-second sit to stand test
Participants will sit in a straight back chair with a solid seat that is 16" high. Participants will have their arms folded across their chest. They will then stand up and sit down as quickly as possible for 30 seconds, keeping their arms folded across their chest. The test is measured with a stopwatch and is completed after 30 seconds, with the number of completed sit to stands taken as the score.
Measured: 5 minutes
Gait velocity
Participants will be asked to walk at a comfortable pace between two lines, marked five metres apart. The time taken will be measured with a stopwatch, with total time taken as the score.
Measured: 2 minutes
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted13 Oct 2017
- Study start22 Jan 2018
- Primary completion31 Jan 2019 (estimated)
- Study completion31 Mar 2019 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for SarcopeniaStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Cross-sectional
- Enrolment
- 40 participants (estimated)
Sponsor and investigators
- Lead sponsor
- University of Bedfordshire
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Prof David Hewson, University of Bedfordshire
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03308903
- Sponsor's protocol ID
- IHREC751
- Status last verified
- Oct 2018
- First submitted
- 9 Oct 2017
- Last updated
- 10 Oct 2018
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- Undecided
Study at a glance
From the registry record, last updated by the sponsor on 10 Oct 2018. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Can the Sit-to-Stand Test be Used as a Screening Tool to Detect Sarcopenia in Community-dwelling Older People?
- ClinicalTrials.gov ID
- NCT03308903
- Acronym / sponsor ID
- IHREC751
- Conditions
- Sarcopenia
- Study type
- Observational
- Recruitment status
- Unknown status
- Enrolment
- 40 participants (estimated)
- Lead sponsor
- University of BedfordshireUniversity, hospital or other
- Study start
- 22 Jan 2018 (actual)
- Primary completion
- 31 Jan 2019 (estimated)
- Study completion
- 31 Mar 2019 (estimated)
- First posted
- 13 Oct 2017 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
A common condition associated with ageing is sarcopenia, which is a progressive decrease in muscle mass. Sarcopenia is associated with adverse outcomes including increased mortality, and places a major burden on healthcare spending, with the annual cost of sarcopenia in the United States exceeding that of osteoporosis and hip fracture. In the UK, the prevalence of sarcopenia in community-dwelling older people has been estimated at 5% for men and 8% for women. Current guidelines for sarcopenia diagnosis require muscle mass to be measured using costly devices such as Dual Energy X-ray Absorptiometry (DXA) and Magnetic Resonance Imaging (MRI). Previous research has found strong relationships between the sit-to-stand (STS) test and both muscle mass and muscle strength. This pilot study aims to examine this relationship in community-dwelling older people to develop predictive equations for initial screening of sarcopenia.
Forty subjects will be tested using the diagnostic criteria developed by the European Working Group on Sarcopenia in Older People (EWGSOP). Muscle mass will be measured using the DXA and diagnostic ultrasound. Muscle strength will be measured using isokinetic dynamometer, handgrip dynamometry, and hand-held dynamometry. Functional performance will be measured using the Timed-up-and-Go and gait velocity, and the STS. Subjects will perform two variants of the STS; the five times STS (5STS), which requires subjects to perform five consecutive STS movements as quick as possible, and the 30-second STS (30STS), which requires subjects to perform as many STS movements as possible in 30 seconds. All testing will be completed in a single session lasting 90 minutes for each subject. Testing will be performed at the University of Bedfordshire Polhill Campus. Subject recruitment will be recruited using advertisement posters and word of mouth.
Detailed description
Loss of function and mobility becomes an increasing concern as we age. Life expectancy is continuing to increase, which in turn leads to age-related diseases and syndromes becoming more common, complex and costly. Sarcopenia is the deficiency of muscle and this refers to the gradual loss of skeletal muscle mass and strength that occurs with advancing age This age-related disease is now understood as a major clinical problem for the elderly and it is becoming a public health issue in today's society.
The European Working Group on Sarcopenia in Older People (EWGSOP) has developed a clinical and practical definition and a diagnostic criterion for age-related sarcopenia. They define sarcopenia as "a syndrome characterised by progressive and generalised loss of skeletal muscle mass and strength with a risk of adverse outcomes". The EWGSOP further develop their definition of sarcopenia into two different categories and three different stages. The two categories are known as primary sarcopenia and secondary sarcopenia. Primary or age-related sarcopenia is when there is no other cause evident except ageing. Whereas secondary sarcopenia is when there are one or more other causes, such as activity-related, disease-related or nutrition-related. The three stages of sarcopenia reflect the severity of the condition; these are known as presarcopenia, sarcopenia and severe sarcopenia. The presarcopenia stage is described as having low muscle mass, without influencing muscle strength or physical performance. The sarcopenia stage is indicated by again having low muscle mass plus either having low muscle strength or poor physical performance. The severe sarcopenia stage is characterised by meeting all three criteria of the definition; low muscle mass, low muscle strength and poor physical performance. The EWGSOP specify that the measurable variables of sarcopenia are muscle mass, muscle strength and physical performance. The challenge they raised is the difficulty determining which methods are best to accurately measure these variables.
The EWGSOP indicate that muscle mass is best measured using body imaging techniques such as magnetic resonance imaging (MRI) or computer-tomography (CT). Both MRI and CT scans are known as the gold standards for measuring muscle mass within research. However, they are costly procedures that are not always freely available. Muscle mass can also be measured through dual energy X-ray absorptiometry (DEXA), for determining the presence of and formulating a diagnosis of sarcopenia. DEXA is based on the measurement of X-ray transmission crossing human tissues. The radiation energies produced by the DEXA are variably attenuated, either scattered or absorbed, by the anatomical structures within the body, dependent on the intensity of the energy and the density and thickness of the human tissues. DEXA enables measurements of fat mass (FM), lean mass (LM) and bone mineral content (BMC) and can assess body masses and bone mineral density (BMD) on a regional and a whole-body basis, whilst exposing only minimal radiation to the patient. According to the EWGSOP, DEXA is a preferred alternative method for measuring muscle mass within research and clinical use. However, it has been reported that measures of muscle mass from DEXA scans do not seem to be accurate, with a site-specific assessment of loss of muscle mass, using ultrasound-based assessment suggested. Ultrasound has been reported to be an effective and non-invasive tool to determine muscle wasting, potentially leading to an earlier and more accurate detection of sarcopenia.
Measures of muscle mass are not as good a predictor of physical capability as muscle strength. Lower limb muscle strength is more relevant for gait and physical function than upper limb muscle strength. However, the EWGSOP recognise handgrip strength as the most widely used method for measuring muscle strength to screen for sarcopenia. Handgrip strength is strongly related with lower extremity muscle power, knee extension torque and calf cross-sectional muscle area. Consequently, it has been documented that muscle power deteriorates earlier and quicker than muscle strength in older populations. Therefore, a measure of muscle power could be more beneficial in the diagnosis of sarcopenia as older people lose power quicker than they do strength. Isokinetic dynamometers (IKD) are a commonly used tool and are recognised as a gold standard measure of muscle power and strength. IKD's measure force dynamically through a specified range of motion whilst allowing the velocity of the movement to be controlled and measured. It is recognised as a popular method to assess muscle function in both clinical and research settings. However, due to IKD's not being portable and are not always accessible, there has been a rise in the use of hand-held dynamometry (HHD) to assess isometric muscle strength. It has been reported that HHD is a simple and inexpensive and a reliable and valid assessment tool for measuring strength, particularity in older adults. The use of isometric strength testing may be more suitable for older adults if there is a limited range of joint motion and if joint pain is prevalent, concentric actions may be challenging.
The importance of using physical performance measures within clinical geriatrics as well as ageing research has also been documented. There are many tests of physical performance that have been validated and are widely used. The EWGSOP identified popular methods for evaluating physical performance. These include the Short Physical Performance Battery (SPPB), usual gait speed (GS), the timed get-up-and-go (TUG) test and the stair climb power test. The ability to rise from a chair has been used in clinical evaluations and on-going assessments for decades. This everyday task was standardised and developed into the 'timed-stands' test. This test was initially designed to measure functional strength of the lower extremities as participants completed 10 timed-stands. Variations of this sit-to-stand (STS) task have evolved and now one of the most commonly used tools for clinical evaluation of physical performance is the Five-Times-Sit-To-Stand (5STS) test. The 5STS, requires the participant to stand up and sit down from a chair five times, with performance taken as the time to complete the test. The STS task was modified further, with a standardised 'time' protocol of 30 seconds (30sSTS), requiring the participant to stand up and sit down as many times as possible within 30 seconds. They reasoned the use of the 30sSTS instead of participants performing a predetermined number of repetitions (e.g. 5STS, 10STS) to assess a wider range of ability. Moreover, the 5STS and potentially even the 10STS can be recorded as the participant performs the 30sSTS. In addition to functional performance, the STS task could also be used to estimate muscle power and even muscle mass. In a recent study, an accurate estimation of lower-limb muscle power was obtained using a simple regression equation in which only body weight and the number of STS performed in 20 seconds, of a 30-second trial were used. Another study had also reported a good estimation of muscle mass obtained from an MRI, again using a simple regression equation in which only three basic variables were used, namely leg length, body mass and the time taken for a single STS movement.
Research Aim The aim of this study is to validate the use of the Sit-To-Stand task as a measure of muscle mass, muscle strength and power and physical performance in screening for sarcopenia compared to gold standard measures, in older adults aged 65 years and over.
Research Objectives
- Suitability of the Sit-To-Stand task as a measure of muscle mass in comparison to the gold standard equivalents, the dual energy x-ray absorptiometry scan and diagnostic ultrasound.
- Suitability of the Sit-To-Stand task as a measure of muscle strength and power in comparison to the gold standard equivalents, the isokinetic dynamometer the hand-grip strength dynamometer and the hand-held dynamometer.
- Suitability of the Sit-To-Stand task as a measure of physical performance in comparison to other well used physical function tests, the Timed-Up-and-Go and gait.
Study design
- Observational model
- Cohort
- Time perspective
- Cross-sectional
Who may qualify
- Ages
- 65 years and older
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Older adult
- Study population
- Community-dwelling people aged 65 years and over with no musculoskeletal problems.
Key inclusion criteria (3 listed)
- Male or female
- Community-dwelling adults
- Aged 65+ years
Key exclusion criteria (8 listed)
- Cardiovascular and/or respiratory problems
- High blood pressure (140/90mmHG or higher)
- Low blood pressure (90/60mmHg or lower)
- A diagnosis of arthritis and/or osteoporosis
- Had a musculoskeletal injury within the last twelve months
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| DEXA scanThe participant will undergo a whole-body DEXA (DEXA; GE Medical Systems, Chalfont St Giles, UK) scan, lasting approximately 5 minutes. This scan will produce body composition data, including estimates of lean body mass (LBM), appendicular lean mass (aLM) and body fat percentage (BF%). | Diagnostic test | – |
Primary outcome
Muscle mass measurement using dual X-ray absorptiometry
Time frame: 5 minutes
The participant will undergo a whole-body DEXA (DEXA; GE Medical Systems, Chalfont St Giles, UK) scan, lasting approximately 5 minutes. This scan will produce body composition data, including M and body fat percentage (BF%). For the purpose of this study, aLM values will be calculated in relation to height (sum of LBM in the arms and legs, scaled to height) (aLM/ht²).
8 secondary outcomes
Hip and knee flexion and extension and ankle plantarflexion and dorsiflexion of both lower extremities on the Biodex System 3 Isokinetic Dynamometer
Time frame: 5 minutes
Five times sit to stand test
Time frame: 5 minutes
Diagnostic ultrasound
Time frame: 5 minutes
Grip strength
Time frame: 5 minutes
Handheld dynamometer assessment of muscle strength
Time frame: 5 minutes
Timed Up and Go test
Time frame: 2 minutes
30-second sit to stand test
Time frame: 5 minutes
Gait velocity
Time frame: 2 minutes
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 10 Oct 2018.
- Individual participant dataSharing planned: Undecided
Related trials for Sarcopenia
Recruiting
Strength and Dual-Task on Sarcopenia in People With Parkinson's Disease
PARKINSON DISEASE (Disorder), Parkinsonism or Parkinson's Disease Nos
Not yet recruitingObservational study
Malnutrition and Sarcopenia in Adults With Chronic Kidney Disease in Tunisia
Malnutrition, Sarcopenia
RecruitingObservational study
Investigating the Link Between Advanced Glycation End Products (AGEs) and Muscle Wasting in Sarcobesity
Sarcopenia, Obesity
Enrolling by invitation
Physical Activity Interventions for Sleep Improvement and Sedative-Hypnotic Reduction in Middle-Aged and Older Adults: Investigating the Role of Sarcopenia
Insomnia Chronic, Hypnotics and Sedatives
Recruiting
Muscle Deterioration in Hospitalized Cancer Patient
Oncologic Diseases
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Sarcopenia, run by University of Bedfordshire at 1 site in United Kingdom.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 10 Oct 2018. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United Kingdom. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
Contact David Hewson, PhD (0044 7525616645, david.hewson@beds.ac.uk), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Muscle mass measurement using dual X-ray absorptiometry (time frame: 5 minutes). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 10 Oct 2018.