Coronary In-stent RestenosisNCT03373695
A Safety and Efficacy Study of Dissolve™ in Treatment of Coronary In-stent Restenosis
A study testing Dissolve™ and SeQuent®Please in people with Coronary In-stent Restenosis, run by DK Medical Technology (Suzhou) Co., Ltd. at 15 sites in China.
Trial summary
The purpose of this study is to evaluate the efficacy and safety of treatment of coronary in-stent restenosis by Paclitaxel-eluting balloon catheter Dissolve™ versus SeQuent®Please, and the reference diameter of coronary artery stenosis is 2.5mm-4.0mm and the length ≤ 26mm. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Coronary In-stent Restenosis
- What is being tested?
- Dissolve™ and SeQuent®Please
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 260 participants
- Where
- 15 sitesChina
- Study dates
- 22 Feb 2018to 24 Apr 2024
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Related to the patients:
- Age ≥18 years old
- Patients who agree to accept the angiography follow-up visit at 9-month and follow up visits at 1-month, 6-month, 9-month, 1-year, 2-year, 3-year, 4-year and 5-year
- Patients with stable angina, unstable angina, old myocardial infarction or proven asymptomatic ischemia
- Patients who can receive any kind of coronary revascularization (including balloon angioplasty, stent implantation or coronary artery bypass grafting)
- Related to lesion:
Show all 11Show fewer
- Restenosis after the first stent implant (including bare metal stents, stents with inert coating, and stents with active coating): Type Mehran I, Type II and Type III; the reference blood vessel diameter is 2.5 mm-4.0 mm, length ≤ 26mm
- Before surgery, stenosis diameter must be ≥ 70% or ≥ 50% and accompanied by ischemia
- The distance between other lesion requires interventional therapy and the target lesion must be > 10mm
- One subject is allowed to have 2 target lesions at most, and 1 paclitaxel drug balloon for each lesion for dilation
- Residual stenosis must be ≤ 30% after pre-dilatation, and dissection must be ≤ NHLBI type B
Who cannot join
- Related to patients
- Pregnant or lactating women, or women who plan to get pregnant within 12 months or refuse to take effective contraceptives
- Patients with cardiogenic shock
- The patients had cerebral stroke within 6 months before being included, or have a history of peptic ulcer or gastrointestinal bleeding, or the patients have a bleeding tendency according to the investigator. Patients who are forbidden to use anticoagulation agents or anti-platelet drugs, and unable to tolerate aspirin or clopidogrel. Patients who are not able to tolerate and comply with dual antiplatelet therapy for at least 3 months after operation
- Patients who have Myocardial Infarction with thrombus or coronary slow flow symptoms and require immediate intervention
- Patients who had ST-Elevation Myocardial Infarction within 1 week before being included
Show all 26Show fewer
- Patients with severe congestive heart failure or NYHA grade IV heart failure
- Patients with moderate or severe valvular heart disease
- Patients who had heart transplantation
- Patients with renal insufficiency (eGFR < 30mL/min)
- The patients have a life expectancy of less than 12 months, or it would be difficult to finish follow-ups within 12 months.
- The patients are participating in any other clinical trials before reaching the primary endpoints
- Patients who are unsuitable for the study according to the investigator due to other reasons
- Related to the Lesion:
- Patients with total occlusion at the target lesion
- Lesion which cannot be treated by percutaneous transluminal coronary angioplasty (PTCA) or percutaneous intervention (PCI)
- Reference vessel diameter < 2.0mm
- Patients with multiple lesions (≥ 3) requiring percutaneous coronary intervention treatment in the same artery
- 3-vessel disease that all need to be intervened
- The diameter of the branch lesions in the target lesion ≥ 2.5mm
- LM lesions and Ostial lesion within 5mm to the root aorta
- Non-target lesion was not intervened successfully before target lesions being intervened
- Related to concomitant therapy:
- Patients cannot tolerate aspirin and/or clopidogrel and or tricagrelor, patients with the history of neutrocytopenia or thrombocytopenia, or patients with severe hypohepatia and prohibited to take clopidogrel
- Patients known allergic to paclitaxel
- Patients known allergic to contrast materials
Trial locations and contacts
15 sites in 1 country.
15 sites in 1 country
China15 sites
Beijing Anzhen Hospital, Capital Medical University
Beijing
Beijing Friendship Hospital, Capital Medical University
Beijing
Beijing Hospital
Beijing
Fuwai Hospital, Chinese Academy of Medical Sciences
Beijing
Peking Union Medical College Hospital
Beijing
Peking University People's Hospital, Capital Medical University
Beijing
Xiangya Hospital of Central South University
Changsha
West China Hospital, Sichuan University
Chengdu
The First Affiliated Hospital of Dalian Medical University
Dalian
The Second Affiliated Hospital of Dalian Medical University
Dalian
General Hospital of Daqing Oil Field
Daqing
Sir Run Run Shaw Hospital, Zhejiang University School of medicine
Hangzhou
The First Affiliated Hospital of Zhengzhou University
Hangzhou
Union Hospital, Tongji Medical College Huazhong University of Science and Technology
Wuhan
General Hospital of Ningxia Medical University
Yinchuan
About this study
Official title: A Multicenter, Randomized, Controlled Clinical Study to Evaluate the Efficacy and Safety of Dissolve™ Compared to SeQuent® Please in Treatment of Coronary In-stent Restenosis in Chinese Population
The purpose of this study is to evaluate the efficacy and safety of treatment of coronary in-stent restenosis by Paclitaxel-eluting balloon catheter Dissolve™ versus SeQuent®Please, and the reference diameter of coronary artery stenosis is 2.5mm-4.0mm and the length ≤ 26mm.
- Conditions
- Coronary In-stent Restenosis
- Being tested
- Dissolve™, SeQuent®Please
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Dissolve™Device
Dissolve™ are to be used in the trial
SeQuent®PleaseDevice
SeQuent®Please are to be used in the trial
| Study group | Role | What they receive |
|---|---|---|
| Dissolve™ | Experimental | Not described Receives: Device: Dissolve™ |
| SeQuent®Please | Active comparator | Not described Receives: Device: SeQuent®Please |
What is being measured
The primary outcome is the main question the study is designed to answer.
In-segment Late Lumen Loss
In-segment late lumen loss is defined as the change in minimal lumen diameter (MLD) within the margins of the device and 5 mm proximal and 5 mm distal to the device from post-procedure to 9 months by angiography.
Measured: From the end of procedure to 9 months after the procedure
Secondary outcomes (9)
Device success rate of the interventional therapy
Successful delivery and use of the assigned balloon at the intended target lesion and successful withdrawal of the delivery system with attainment of final residual stenosis of less than 30% and TIMI 3 blood flow by visual estimation.
Measured: From the start of index procedure to end of index procedure
Lesion success rate of the interventional therapy
Attainment of final residual stenosis of target lesion less than 30% and TIMI 3 blood flow by visual estimation.
Measured: From the start of index procedure to end of index procedure
Clinical success rate of the interventional therapy
Achievement of final residual stenosis of less than 30% by visual estimation with successful delivery and use of assigned balloon at the intended target lesion and successful withdrawal of the delivery system for the target lesion without the occurrence of cardiac death, target vessel Myocardial Infarction (MI) or repeat Target lesion revascularization (TLR).
Measured: 7 days after the procedure
Rate of restenosis in the target lesions
Restenosis is defined as stenosis > 30% by angiography
Measured: 9 months after the procedure
TLR rate
Measured: 9 months after the procedure
Target vessel revascularization (TVR) rate
Measured: 9 months after the procedure
Target lesion failure (TLF) rate
Measured: 9 months after the procedure
Rate of major adverse cardiovascular events
Measured: 1 month, 6 months, 9 months, 1 year, 2 years, 3 years, 4 years and 5 years after the procedure
Rate of all adverse events and severe adverse events
Measured: 1 month, 6 months, 9 months, 1 year, 2 years, 3 years, 4 years and 5 years after the procedure
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted14 Dec 2017
- Study start22 Feb 2018
- Primary completion9 Jan 2020
- Study completion24 Apr 2024
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (1)Papers the sponsor has linked to this study.
- Other trials for Coronary In-stent RestenosisStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Enrolment
- 260 participants (actual)
Sponsor and investigators
- Lead sponsor
- DK Medical Technology (Suzhou) Co., Ltd.
- Sponsor type
- Industry (pharma, biotech, devices)
- Collaborators
- Core Medical (Beijing) Co., Ltd.
- Responsible party
- Sponsor
- Investigators
- Shubin Qiao, Principal investigator, Chinese Academy of Medical Sciences, Fuwai Hospital
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03373695
- Sponsor's protocol ID
- CL-VP-01
- Status last verified
- Feb 2025
- First submitted
- 5 Dec 2017
- Last updated
- 20 Feb 2025
- Results posted
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Undecided
Publications
Liu S, Zhou Y, Shen Z, Chen H, Qiu C, Fu G, Li H, Yu Z, Zeng Q, Li Z, Li W, Qiao S; Dissolve ISR Investigators. A Randomized Comparison of 2 Different Drug-Coated Balloons for In-Stent Restenosis. JACC Cardiovasc Interv. 2023 Apr 10;16(7):759-767. doi: 10.1016/j.jcin.2022.12.018.
PubMed 37045496
Study at a glance
From the registry record, last updated by the sponsor on 20 Feb 2025. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Multicenter, Randomized, Controlled Clinical Study to Evaluate the Efficacy and Safety of Dissolve™ Compared to SeQuent® Please in Treatment of Coronary In-stent Restenosis in Chinese Population
- ClinicalTrials.gov ID
- NCT03373695
- Acronym / sponsor ID
- CL-VP-01
- Conditions
- Coronary In-stent Restenosis
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 260 participants (actual)
- Lead sponsor
- DK Medical Technology (Suzhou) Co., Ltd.Industry (pharma, biotech, devices)
- Collaborators
- Core Medical (Beijing) Co., Ltd.
- Study start
- 22 Feb 2018 (actual)
- Primary completion
- 9 Jan 2020 (actual)
- Study completion
- 24 Apr 2024 (actual)
- First posted
- 14 Dec 2017 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The purpose of this study is to evaluate the efficacy and safety of treatment of coronary in-stent restenosis by Paclitaxel-eluting balloon catheter Dissolve™ versus SeQuent®Please, and the reference diameter of coronary artery stenosis is 2.5mm-4.0mm and the length ≤ 26mm.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Dissolve™ | Experimental | Device: Dissolve™ |
| SeQuent®Please | Active comparator | Device: SeQuent®Please |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (11 listed)
- Age ≥18 years old
- Patients who agree to accept the angiography follow-up visit at 9-month and follow up visits at 1-month, 6-month, 9-month, 1-year, 2-year, 3-year, 4-year and 5-year
- Patients with stable angina, unstable angina, old myocardial infarction or proven asymptomatic ischemia
- Patients who can receive any kind of coronary revascularization (including balloon angioplasty, stent implantation or coronary artery bypass grafting)
- Restenosis after the first stent implant (including bare metal stents, stents with inert coating, and stents with active coating): Type Mehran I, Type II and Type III; the reference blood vessel diameter is 2.5 mm-4.0 mm, length ≤ 26mm
Key exclusion criteria (26 listed)
- Related to patients
- Pregnant or lactating women, or women who plan to get pregnant within 12 months or refuse to take effective contraceptives
- Patients with cardiogenic shock
- The patients had cerebral stroke within 6 months before being included, or have a history of peptic ulcer or gastrointestinal bleeding, or the patients have a bleeding tendency according to the investigator. Patients who are forbidden to use anticoagulation agents or anti-platelet drugs, and unable to tolerate aspirin or clopidogrel. Patients who are not able to tolerate and comply with dual antiplatelet therapy for at least 3 months after operation
- Patients who have Myocardial Infarction with thrombus or coronary slow flow symptoms and require immediate intervention
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Dissolve™Dissolve™ are to be used in the trial | Device | Dissolve™ |
| SeQuent®PleaseSeQuent®Please are to be used in the trial | Device | SeQuent®Please |
Primary outcome
In-segment Late Lumen Loss
Time frame: From the end of procedure to 9 months after the procedure
In-segment late lumen loss is defined as the change in minimal lumen diameter (MLD) within the margins of the device and 5 mm proximal and 5 mm distal to the device from post-procedure to 9 months by angiography.
9 secondary outcomes
Device success rate of the interventional therapy
Time frame: From the start of index procedure to end of index procedure
Lesion success rate of the interventional therapy
Time frame: From the start of index procedure to end of index procedure
Clinical success rate of the interventional therapy
Time frame: 7 days after the procedure
Rate of restenosis in the target lesions
Time frame: 9 months after the procedure
TLR rate
Time frame: 9 months after the procedure
Target vessel revascularization (TVR) rate
Time frame: 9 months after the procedure
Target lesion failure (TLF) rate
Time frame: 9 months after the procedure
Rate of major adverse cardiovascular events
Time frame: 1 month, 6 months, 9 months, 1 year, 2 years, 3 years, 4 years and 5 years after the procedure
Rate of all adverse events and severe adverse events
Time frame: 1 month, 6 months, 9 months, 1 year, 2 years, 3 years, 4 years and 5 years after the procedure
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 20 Feb 2025.
- Derived from this study: PubMed 37045496Liu S, Zhou Y, Shen Z, Chen H, Qiu C, Fu G, Li H, Yu Z, Zeng Q, Li Z, Li W, Qiao S; Dissolve ISR Investigators. A Randomized Comparison of 2 Different Drug-Coated Balloons for In-Stent Restenosis. JACC Cardiovasc Interv. 2023 Apr 10;16(7):759-767. doi: 10.1016/j.jcin.2022.12.018.
- Individual participant dataSharing planned: Undecided
Related trials for Coronary In-stent Restenosis
Not yet recruiting
Sirolimus-Coated Versus Paclitaxel-Coated Balloon for Recurrent Coronary In-Stent Restenosis After Prior Paclitaxel-Coated Balloon Treatment (SPRIT)
Coronary In-stent Restenosis, Coronary Artery Disease
Recruiting
Virtue® SAB in the Treatment of Coronary ISR Trial
Coronary Artery Disease
Recruiting
Prevail Global Study
Coronary Artery Disease
Active, not recruiting
SELUTION SLR™ 014 In-stent Restenosis
Coronary Restenosis
RecruitingObservational study
Real-World Outcomes of Drug-Coated Balloon Angioplasty in Coronary Artery Disease
Coronary Artery Disease
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Shubin Qiao principal investigator
Chinese Academy of Medical Sciences, Fuwai Hospital
15 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Dissolve™ and SeQuent®Please in people with Coronary In-stent Restenosis, run by DK Medical Technology (Suzhou) Co., Ltd. at 15 sites in China.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 11 inclusion and 26 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 20 Feb 2025. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 15 sites in China. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
In-segment Late Lumen Loss (time frame: From the end of procedure to 9 months after the procedure). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT03373695, which also lists 1 linked publication.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 20 Feb 2025.