AzTrials
AzTrials

Chronic Total Occlusion of Coronary ArteryVACTORNCT03475888

Incidence of Ventricular Arrhythmias in Patients With Chronic Total Occlusion Recanalization

A study testing Medtronic Reveal LINQ™ Insertable Cardiac Monitor (ICM) in people with Chronic Total Occlusion of Coronary Artery, run by Erasmus Medical Center at 2 sites in Netherlands.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

A chronic total occlusion (CTO) is common in patients with coronary artery disease. CTO recanalization has been shown to improve survival in comparison to failed CTO recanalization. Whether this is related to ventricular arrhythmias (VA) is unknown. Read more about this study

Who is it for?
Ages 18 years and older
What is being tested?
Medtronic Reveal LINQ™ Insertable Cardiac Monitor (ICM)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
90 participants
Where
2 sitesNetherlands
Study dates
28 Sep 2018to 12 Dec 2022
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Presence of CTO defined as complete obstruction of the vessel with Thrombolysis In Myocardial Infarction (TIMI) flow grade 0 and an estimated duration of ≥3 months, and one of the following:
  • A successful percutaneous CTO recanalization for stable angina within the previous 6 months. A successful CTO recanalization is defined as a final TIMI flow grade ≥2 and a residual stenosis ≤30% after stent implantation.
  • A failed percutaneous CTO recanalization for stable angina within the previous 6 months. A failed CTO recanalization is defined as not fulfilling the criteria for successful CTO recanalization.
  • Untreated CTO diagnosed in the previous 6 months.
  • Age ≥18 years.
  • Written informed consent.
  • Patient agrees to the follow-up including the implantation of the ICM.

Who cannot join

  • Patients who are potential candidates for an ICD according to the 2015 ESC guidelines.
  • Patients who have a cardiac implantable electrical device (CIED) (e.g., pacemaker, ICD).
  • Patient has reduced immune function or is otherwise at high risk for infection.
  • Patient has had a recent (within 30 days) or otherwise unresolved infection.
  • Known pregnancy at time of inclusion.
  • Patient has severe co-morbidity that may cause the patient to be non-compliant with the protocol, confound the data interpretation or is associated with limited life expectancy (i.e., less than one year).

Trial locations and contacts

2 sites in 1 country.

Netherlands2 sites
  • VUMC

    Amsterdam

  • Erasmus Medical Center

    Rotterdam

Other trials in Netherlands

About this study

A chronic total occlusion (CTO) is common in patients with coronary artery disease. CTO recanalization has been shown to improve survival in comparison to failed CTO recanalization. Whether this is related to ventricular arrhythmias (VA) is unknown. The purpose of this pilot study is to evaluate the incidence of VA after successful CTO recanalization and in those with failed CTO recanalization or untreated CTO. Patients will be monitored using an insertable cardiac monitor.

Read the detailed description

Rationale: Successful chronic total occlusion (CTO) recanalization has been associated with improved long-term survival. Furthermore, CTO is an independent predictor for the occurrence of ventricular arrhythmias (VA) in patients with ischemic cardiomyopathy and implantable cardioverter defibrillators (ICDs). One may speculate that a successful CTO recanalization may provide electrical stability. However, no data are available on the incidence of sustained VA in this patient population.

Objective: The objective of the present pilot study is to assess the incidence of sustained VA in 2 CTO groups: patients with successful percutaneous CTO recanalization (group A), patients with failed percutaneous CTO recanalization or untreated CTO (group B).

Study design: Pilot study of patients with CTO.

Study population: A total of 90 patients will be enrolled with a maximum of 45 patients in each arm.

Intervention: A Medtronic Reveal LINQ™ Insertable cardiac monitor (ICM) will be implanted in every patient to continuously monitor heart rhythm during the follow-up period.

Main study parameters/endpoints: To assess the incidence of VA defined as sustained ventricular tachycardia >30 s or ventricular fibrillation.

Being tested
Medtronic Reveal LINQ™ Insertable Cardiac Monitor (ICM)
Keywords
Chronic Total Occlusion of Coronary Artery, Ventricular Arrythmia, Sustained VT, Ventricular Fibrillation, Implantable loop recorder
Medical subject headings
Ventricular Fibrillation

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Medtronic Reveal LINQ™ Insertable Cardiac Monitor (ICM)Device

    Implantation of Medtronic Reveal LINQ™ ICM

Study groups in NCT03475888
Study groupRoleWhat they receive
Group AActive comparatorPatients who have undergone a successful percutaneous CTO recanalization
Receives: Device: Medtronic Reveal LINQ™ Insertable Cardiac Monitor (ICM)
Group BActive comparatorPatients who have undergone a failed percutaneous CTO recanalization or have an untreated CTO
Receives: Device: Medtronic Reveal LINQ™ Insertable Cardiac Monitor (ICM)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Ventricular Arrhythmias

    Sustained ventricular tachycardia (>30 s) or ventricular fibrillation

    Measured: 3 years after ICM implantation

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted23 Mar 2018
  2. Study start28 Sep 2018
  3. Primary completion12 Dec 2022
  4. Study completion12 Dec 2022

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Non-randomised
Intervention model
Parallel groups
Model description
Single center pilot study of patients with CTO.
Masking
None (open label)
Enrolment
90 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03475888
Sponsor's protocol ID
NL59827.078.16
Acronym
VACTOR
Status last verified
Feb 2024
First submitted
12 Mar 2018
Last updated
20 Feb 2024
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Assaf A, Sakhi R, Diletti R, Hirsch A, Allaart CP, Bhagwandien R, Firouzi M, Smits PC, Hoogendijk MG, Theuns DAMJ, Yap SC. Incidence of ventricular arrhythmias in patients with chronic total coronary occlusion: Results of the VACTOR study. Int J Cardiol Heart Vasc. 2023 Dec 18;50:101323. doi: 10.1016/j.ijcha.2023.101323. eCollection 2024 Feb.

    PubMed 38188347

Questions about this trial

What is this clinical trial studying?

A study testing Medtronic Reveal LINQ™ Insertable Cardiac Monitor (ICM) in people with Chronic Total Occlusion of Coronary Artery, run by Erasmus Medical Center at 2 sites in Netherlands.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 7 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 20 Feb 2024. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 2 sites in Netherlands. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Ventricular Arrhythmias (time frame: 3 years after ICM implantation). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03475888, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 20 Feb 2024.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in