The EXPLORE Study - The Use of Binocular OCT Imaging for the Assessment of Ocular Disease

An observational study of Eye Diseases and Eye Infections, run by University College, London at 1 site in United Kingdom.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Optical coherence tomography (OCT) is an imaging modality, first described in 1991, that provides cross-sectional images of the eye in a non-invasive manner. OCT is analogous to ultrasonography but measures the "echoes" of light waves rather than sound and, as a result, generates extremely high-resolution images (~5… Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Eye Diseases, Eye Infections, Eye Inflammation
What is being tested?
Binocular OCT
Type of treatment
Medical device
How many people
70 participants
Where
1 siteUnited Kingdom
Study dates
22 May 2018to 1 Mar 2020
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • Adult, Older adult

Study population: Participants with various eye diseases will be recruited from appropriate eye clinics at Moorfields Eye Hospital. Eye conditions will include both anterior segment disease such as corneal disease and ocular inflammatory disease, retinal vascular and macular diseases, and optic nerve disease such as glaucoma.

Who may be able to join

  • Presence of ocular disease that can be imaged using optical coherence tomography
  • Male or female, aged 18 years or older
  • Ability to understand nature/purpose of the study and to provide informed consent
  • Ability to undergo binocular OCT imaging
  • Ability to follow instructions and complete the study
  • Ability to speak English

Who cannot join

  • Optical media opacity sufficient to preclude adequate ocular imaging with OCT
  • Hearing impairment sufficient to interfere with hearing instructions
  • Any condition which, in the investigator's opinion, would conflict or otherwise prevent the subject from complying with the required procedures, schedule, or other study conduct

Trial locations and contacts

1 site in 1 country.

United Kingdom1 site
  • Moorfields Eye Hospital NHS FT

    London, EC1V 2PD

Other trials in United Kingdom

About this study

Official title: A Prospective Single-Site Non-Interventional Exploratory Study Using a Prototype Binocular Optical Coherence Tomography System for Imaging of Ocular Disease

Optical coherence tomography (OCT) is an imaging modality, first described in 1991, that provides cross-sectional images of the eye in a non-invasive manner. OCT is analogous to ultrasonography but measures the "echoes" of light waves rather than sound and, as a result, generates extremely high-resolution images (~5 μm axial resolution). Although OCT has already proven revolutionary in ophthalmology, current OCT systems are large, expensive, and require skilled personnel for image acquisition and interpretation. Furthermore, current OCT systems are limited to examination of specific regions of single eyes - for example, separate devices are typically required for anterior segment (e.g., cornea) versus posterior segment (e.g., retina) imaging. A new form of OCT imaging has recently been developed - so-called "binocular" optical coherence tomography (OCT) (Envision Diagnostics, Inc., California).1,2 Binocular OCT addresses many of the short-comings of conventional OCT devices.

Binocular OCT extends the application of OCT devices beyond that of simple, cross- sectional imaging to a diverse array of diagnostic tests. The binocular design also removes the need for additional personnel to perform testing (i.e., the device can be self-operated in an automated manner), and allows for novel testing to be performed that is not possible with monocular imaging. In particular, binocular OCT devices have the potential to perform automated, quantitative pupillary measurements - an entirely novel application for this imaging modality, plus also adds a number of unique capabilities. In particular, binocular OCT removes the need for additional personnel to acquire the images by enabling patients to align the optical axes of the instrument with the optical axes of their own eyes. The system also employs recently developed "swept-source" lasers as its light source, allowing it to see deeper into the eye than conventional OCT systems. Finally, binocular OCT systems allow image capture from both eyes at the same time. This "simultaneous" ocular imaging extends the range of diagnostic testing possible, allowing for features such as pupillometry and ocular motility.

Read more

The greatly increased range of imaging for these lasers enables the entire depth of eye tissue to be captured in just a few sequences of images - so- called "whole eye" OCT or "OCT ophthalmoscopy".

In this study, the investigators aim to explore the unique imaging features of the binocular OCT to describe novel features across a range of diseases. The repeatability of quantifying various parameters in the images acquired using the system will be assessed.

Read the detailed description

Imaging of the retina using OCT is the commonest ophthalmic imaging procedure worldwide - in 2011, it is estimated that more than 20 million retinal OCT images were obtained, more than the sum of all other ophthalmic imaging procedures combined).4 OCT is also used to image the anterior segment, particularly to measure corneal thickness, in glaucoma to measure the irido-corneal angle, 5 and more recently to measure cells in ocular inflammatory conditions. In addition, vitreous imaging may be useful to measure cells in the posterior chamber.

Most OCT systems are dedicated to retinal imaging or anterior segment imaging. Some commercial retinal scanners are capable of switching between anterior and posterior imaging modes with additional optical attachments, however anterior segment imaging performance is typically suboptimal in these instruments. A key feature of the Binocular OCT is that it can perform 'whole-eye' OCT imaging spanning from the eyelids to the posterior pole in a single instrument without the requirement of additional attachments, and in an automated way.

This study will determine whether the instrument can be used for patients with different eye diseases. The investigators anticipate recruiting approximately 100 participants with anterior eye conditions such as keratoconus, acute anterior uveitis, and pigment dispersion syndrome, in addition to approximately 100 participants with posterior segment eye conditions such as diabetic retinopathy, age-related macular degeneration, and glaucoma.

As this device can image many structures of the eye and with a greater depth range than most commercial OCT devices, it may be possible to visualise features not previously imaged with other devices such as vitreous imaging, or imaging of cells in the ocular inflammatory conditions. In this study, the prototype binocular OCT system will be used to describe novel features across a range of ocular diseases. Qualitative analyses of raw binocular OCT images will be performed (including assessments of retinal pathological features, corneal and anterior chamber morphology, lens status, iris dynamics, and ocular inflammatory cells). These parameters will be correlated with findings from other non-invasive ocular imaging previously obtained during routine clinical care. Although raw OCT images can be useful for diagnosis, quantitative data from the images are useful to monitor eye disease. Commercial OCT devices have built-in software packages to analyse OCT images to provide the clinician with parameters for detecting and monitoring eye disease. Quantitative analysis of binocular OCT images will be performed using MATLAB (The MathWorks, Inc., Natick, Massachusetts, United States).

In addition, the ability to combine structural and functional assessments in the same instrument may permit better examinations of ophthalmic disease compared to separate clinical tests. This study will also permit future studies to be correctly powered.

Being tested
Binocular OCT
Keywords
Optical Coherence Tomography, Automated, Binocular
Medical subject headings
Eye Diseases, Eye Infections, Endophthalmitis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Binocular OCTDevice

    Participants in the study will undergo OCT imaging using a prototype binocular OCT imaging system (Envision Diagnostics, Inc., CA) twice to assess repeatability.).

Study groups in NCT03553017
Study groupRoleWhat they receive
Participants with eye diseaseA maximum of 200 participants with various eye diseases will be recruited from appropriate eye clinics at Moorfields Eye Hospital. Eye conditions will include both anterior segment disease such as corneal disease and ocular inflammatory disease, retinal vascular and macular diseases, and optic nerve disease such as glaucoma.
Receives: Device: Binocular OCT

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Repeatability of the binocular OCY

    The primary objective will be to assess the repeatability of quantifying various parameters in images acquired using a prototype binocular OCT system. This will be explored in different diseases.

    Measured: 2 years

Secondary outcomes (1)
  1. Comparison with other devices

    The secondary objective will be to compare to other imaging modalities and describe novel features across a range of ocular diseases.

    Measured: 2 years

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted12 Jun 2018
  2. Study start22 May 2018
  3. Primary completion1 Mar 2020
  4. Study completion1 Mar 2020

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Case only
Time perspective
Cross-sectional
Enrolment
70 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03553017
Sponsor's protocol ID
17/0839
Status last verified
Oct 2020
First submitted
29 May 2018
Last updated
19 Oct 2020
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No

Publications

  • Chopra R, Mulholland PJ, Dubis AM, Anderson RS, Keane PA. Human Factor and Usability Testing of a Binocular Optical Coherence Tomography System. Transl Vis Sci Technol. 2017 Aug 15;6(4):16. doi: 10.1167/tvst.6.4.16. eCollection 2017 Jul.

    PubMed 28824827
  • Walsh AC. Binocular optical coherence tomography. Ophthalmic Surg Lasers Imaging. 2011 Jul;42 Suppl:S95-S105. doi: 10.3928/15428877-20110627-09.

    PubMed 21790117

Questions about this trial

What is this clinical trial studying?

An observational study of Eye Diseases and Eye Infections, run by University College, London at 1 site in United Kingdom.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 6 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 19 Oct 2020. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United Kingdom. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Repeatability of the binocular OCY (time frame: 2 years). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03553017, which also lists 2 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 19 Oct 2020; AzTrials last refreshed its copy on 3 Nov 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in