AzTrials
AzTrials

PainPhase 4CADD2NCT03553576

Drug Concentration and Volume on Adequate Labor Analgesia With PIEB

A Phase 4 study testing Low volume bolus and High volume bolus in people with Pain and Anesthesia, run by Northwestern University at 1 site in United States.

Terminated

Stopped early. The study ended before it was planned to and will not resume.

Official record
Search all trials

Trial summary

Neuraxial labor analgesia is performed by the administration of a local anesthetic/opioid mixture in the epidural space. The delivery method is a combination of continuous infusion, provider-administered boluses and patient-administered boluses (patient controlled epidural analgesia [PCEA]) via epidural catheter. Read more about this study

Who is it for?
Ages 18 years and older, women only
Conditions the study is for
Pain, Anesthesia, Labor Pain
What is being tested?
Low volume bolus and High volume bolus
Could I receive a placebo?
No, everyone receives an active treatment
How many people
146 participants
Where
1 siteUnited States
Study dates
21 Jan 2020to 1 Jun 2023
Phase
Phase 4
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • Women only
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • 18 years and above
  • Nulliparous parturients
  • Present to the labor and delivery unit for an induction of labor or who are in spontaneous labor
  • Request neuraxial labor analgesia at ≤5 cm cervical dilation

Who cannot join

  • Patients who are not eligible to receive a combined spinal epidural (CSE) technique with 25 mcg of intrathecal fentanyl
  • Non-English speaking
  • Failed initiation of CSE analgesia (VAS pain score >10 15 minutes after intrathecal dose)
  • Need to have the epidural catheter replaced during labor
  • Who deliver within 90 minutes of initiation of labor analgesia
  • Require re-dose within 90 minutes of initiation of labor analgesia.

Trial locations and contacts

1 site in 1 country.

United States1 site
  • Prentice Women's Hospital

    Chicago, Illinois, 60611

Other trials in United States

About this study

Official title: The Relationship Between Local Anesthetic Concentration and Volume on Adequate Labor Analgesia With Programmed Intermittent Epidural Bolus

Neuraxial labor analgesia is performed by the administration of a local anesthetic/opioid mixture in the epidural space. The delivery method is a combination of continuous infusion, provider-administered boluses and patient-administered boluses (patient controlled epidural analgesia [PCEA]) via epidural catheter. The anesthetic solution administered through the lumbar epidural catheter must spread cephalad in the epidural space to reach the T10 nerve roots and spinal cord, and must spread caudad to reach the caudal nerve roots in the epidural space.

Epidural infusion pumps capable of delivering PIEB of local anesthetic with PCEA have become commercially available and many studies have attempted to assess the optimal parameter settings (including volume of programmed bolus, bolus interval, rate of bolus administration) to provide superior labor analgesia.

Read more

Traditionally higher concentration local anesthetic solutions have been associated with increased motor blockade leading to a higher incidence of instrumental vaginal delivery. Several local anesthetic solutions with varying drug concentrations are available for labor analgesia and are used clinically in the United States. We plan to perform a randomized, controlled, double-blind study to test the hypothesis that patients whose labor analgesia is maintained using PIEB with low-volume bolus (6.25 mL) of a higher local anesthetic concentration solution (0.1% bupivacaine with fentanyl 2.0 mcg/mL) will require less supplemental analgesia (manual provider re-doses) than patients whose PIEB is delivered with a high-volume bolus (10 mL) of lower density local anesthetic solution (0.0625% bupivacaine with fentanyl 2.0 mcg/mL).

The aim of this study is to evaluate the association between bolus volume and concentration of local anesthetic during maintenance of labor analgesia with programmed intermittent epidural bolus (PIEB) analgesia.

The hypothesis of this study is: patients whose labor analgesia is maintained using PIEB with low-volume bolus (6.25 mL) of higher local anesthetic concentration solution (0.1% bupivacaine with fentanyl 2.0 mcg/mL) will have a longer duration of adequate analgesia (time to first manual re-dose request) than patients whose PIEB is delivered with a high-volume bolus (10 mL) of lower concentration local anesthetic solution (0.0625% bupivacaine with fentanyl 2.0 mcg/mL).

Being tested
Low volume bolus, High volume bolus
Keywords
Labor pain, Epidural, Obstetric, Labor Analgesia
Medical subject headings
Pain, Labor Pain

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Low volume bolusDrug

    Administration of a low-volume bolus (6.25 mL) of greater density solution (0.1% bupivacaine with fentanyl 2.0 mcg/mL) at 250 mL per hour given by CADD pump.

  • High volume bolusDrug

    Administration of a high-volume bolus (10 mL) of lower density local anesthetic (0.0625% bupivacaine with fentanyl 2.0 mcg/mL) at 250 mL per hour given by CADD pump.

Study groups in NCT03553576
Study groupRoleWhat they receive
Low volume bolusExperimental6.25 mL administration at 250 ml per hour of a greater density solution (0.1% bupivacaine with fentanyl 2.0 mcg/mL)
Receives: Drug: Low volume bolus
High volume bolusExperimental10 mL administration of a lower density local anesthetic (0.0625% bupivacaine with fentanyl 2.0 mcg/mL).
Receives: Drug: High volume bolus

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Anesthesia Provider Administered Bolus

    Anesthesia provider (MD) administered boluses of additional anesthetic administered prior to the delivery of the baby.

    Measured: 72 hours

Secondary outcomes (14)
  1. VAS at 10 Centimeters Dilation of Cervix

    VAS (visual analogue scale) at 10 centimeters dilation of cervix on a scale of 0 (no pain,good) to 100 (worst pain imaginable,bad)

    Measured: 24 hours

  2. VAS Score After Delivery

    VAS score (Visual Analogue Scale) on a score of 0 (no pain,good) to 100 (worst pain imaginable,bad) immediately after delivery of baby

    Measured: 24 hours

  3. Intrascapular Pain

    Number of participants who experienced intrascapular pain (pain in your shoulder blade) during the study period.

    Measured: 72 hours

  4. Provider Administered Bolus

    Number of participants requiring anesthesia provider administration of additional bolus doses of pain medication.

    Measured: 72 hours

  5. Number of Participants Who Required Additional Provider Redoses

    Additional number of participants who required additional anesthesia care provider redoses of pain medication.

    Measured: 72 hours

  6. Time to First Anesthesiology Provider Bolus

    Time elapsed in minutes from epidural set up to time to request supplemental analgesia provided by the anesthesiology care provider.

    Measured: 72 hours

  7. VAS Score Prior to First Provider Bolus Dose

    Patient reported visual analogue scale score (0 no pain,good-100 worst pain imaginable, bad) prior to the first anesthesiology care provider bolus dose of anesthetic (pain medication).

    Measured: 72 hours

  8. VAS Score 30 Minutes After Anesthetic Care Provider Dose

    Patient reported visual analogue scale score (0 no pain, good -100 worst pain imaginable, bad) 30 minutes after the first anesthesiology care provider bolus dose of anesthetic was administered to the participant for pain relief.

    Measured: 72 hours

  9. Bupivacaine Consumption Per Hour

    Average consumption of bupivacaine in milligrams per hour.

    Measured: 72 hours

  10. Maximum Oxytocin Dose

    Maximum oxytocin dose administered intravenously in international units.

    Measured: 72 hours

  11. Time of Intrathecal Administration to Delivery

    Elapsed time in minutes from the intrathecal administration of anesthetic by anesthesiology provider to time of delivery of baby.

    Measured: 72 hours

  12. Number of Participants Categorized by Mode of Delivery

    Mode of delivery identified as: normal vaginal delivery, instrumental vaginal delivery, cesarean delivery or emergency cesarean delivery

    Measured: 72 hours

  13. PCA Boluses

    Number of Patient-Controlled Epidural Analgesia (PCEA) boluses of pain medication requested and number of PCEA medication boluses administered.

    Measured: 72 hours

  14. PCA Boluses Ratio

    The ratio of the number of Patient-Controlled Epidural Analgesia (PCEA) pain medication boluses requested and number of PCEA pain medication boluses administered by the PCEA pump.

    Measured: 72 hours

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted12 Jun 2018
  2. Study start21 Jan 2020
  3. Primary completion31 May 2023
  4. Study completion1 Jun 2023

Why it stopped: Lack of continued funding

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase 4
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Model description
Two group randomized controlled trial
Masking
Double blind
Who is masked
Participant, Outcomes assessor
Enrolment
146 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03553576
Sponsor's protocol ID
STU00206113
Acronym
CADD2
Status last verified
May 2025
First submitted
30 May 2018
Last updated
21 May 2025
Data monitoring committee
Yes
FDA-regulated drug
Yes
FDA-regulated device
No

Publications

  • Wong CA, Ratliff JT, Sullivan JT, Scavone BM, Toledo P, McCarthy RJ. A randomized comparison of programmed intermittent epidural bolus with continuous epidural infusion for labor analgesia. Anesth Analg. 2006 Mar;102(3):904-9. doi: 10.1213/01.ane.0000197778.57615.1a.

    PubMed 16492849
  • Lim Y, Sia AT, Ocampo C. Automated regular boluses for epidural analgesia: a comparison with continuous infusion. Int J Obstet Anesth. 2005 Oct;14(4):305-9. doi: 10.1016/j.ijoa.2005.05.004.

    PubMed 16154735
  • Chua SM, Sia AT. Automated intermittent epidural boluses improve analgesia induced by intrathecal fentanyl during labour. Can J Anaesth. 2004 Jun-Jul;51(6):581-5. doi: 10.1007/BF03018402.

    PubMed 15197122
  • Kaynar AM, Shankar KB. Epidural infusion: continuous or bolus? Anesth Analg. 1999 Aug;89(2):534. doi: 10.1097/00000539-199908000-00063. No abstract available.

    PubMed 10439786
  • Hogan Q. Distribution of solution in the epidural space: examination by cryomicrotome section. Reg Anesth Pain Med. 2002 Mar-Apr;27(2):150-6. doi: 10.1053/rapm.2002.29748.

    PubMed 11915061
  • Comparative Obstetric Mobile Epidural Trial (COMET) Study Group UK. Effect of low-dose mobile versus traditional epidural techniques on mode of delivery: a randomised controlled trial. Lancet. 2001 Jul 7;358(9275):19-23. doi: 10.1016/S0140-6736(00)05251-X.

    PubMed 11454372

Questions about this trial

What is this clinical trial studying?

A Phase 4 study testing Low volume bolus and High volume bolus in people with Pain and Anesthesia, run by Northwestern University at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: stopped early, as of the sponsor's last update on 21 May 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

What does this phase mean?

Phase 4 studies take place after a treatment is approved, to learn more about its long-term benefits and risks in everyday use.

Not every study follows the same path, and some studies (observational studies, device studies) have no phase.

Are results available for this study?

Yes. Results are posted in the registry (first posted 21 May 2025). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Anesthesia Provider Administered Bolus (time frame: 72 hours). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03553576, which also lists 6 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 21 May 2025.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in