HypotensionADIVANCT03620942

Development of Advanced Double Intravenous Vasopressor Automated (ADIVA) System

A study testing Phenylephrine, Ephedrine and ADIVA System in people with Hypotension and Anesthesia, run by KK Women's and Children's Hospital at 1 site in Singapore.

Active, not recruiting

Under way, not looking for participants. Everyone needed has enrolled. The study is still running.

Official record
Search all trials

Trial summary

Maternal hypotension during spinal anaesthesia for Caesarean delivery may bring various adverse effects. It is therefore important to closely monitor hypotension during spinal anaesthesia, however current technology does not allow the blood pressure monitoring to respond in timely manner should there be any occurrence… Read more about this study

Who is it for?
Ages 21 to 50 years, women only
Conditions the study is for
Hypotension, Anesthesia
What is being tested?
Phenylephrine, Ephedrine and ADIVA System
Could I receive a placebo?
No, everyone receives an active treatment
How many people
173 participants
Where
1 siteSingapore
Study dates
7 Nov 2018to 31 Dec 2027
Phase
Interventional
Are there results?
Not yet: the study is under way

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 21 to 50 years
  • Women only
  • No healthy volunteers
  • Adult

Who may be able to join

  • Healthy adult (American Society of Anesthesiologists physical status 1 and 2) parturients;
  • With singleton full-term pregnancy;
  • The indication for an elective cesarean delivery;
  • The use of spinal anaesthesia for cesarean delivery;
  • Anthropometric profile within the following range: age 21-50 years old, weight 40-90 kg and height of 145-170 cm.

Who cannot join

  • Obstetric (e.g. pre-eclampsia, premature rupture of amniotic membranes for more than 48 hours, gestational diabetes on insulin, pregnancy-induced hypertension on medication) and uncontrolled medical (e.g. cardiac disease) complications;
  • Contraindication to spinal anaesthesia and/or allergy to opioids.

Trial locations and contacts

1 site in 1 country.

Singapore1 site
  • KK Women's and Children's Hospital

    Singapore, 229899

Other trials in Singapore

About this study

Official title: Development of Advanced Double Intravenous Vasopressor Automated (ADIVA) System With Improved Hemodynamic Trend Control During Spinal Anaesthesia for Caesarean Section

Maternal hypotension during spinal anaesthesia for Caesarean delivery may bring various adverse effects. It is therefore important to closely monitor hypotension during spinal anaesthesia, however current technology does not allow the blood pressure monitoring to respond in timely manner should there be any occurrence of hypotension. The investigators developed an advanced double-intravenous vasopressor automated system (ADIVA) so as to tackle this issue via novel algorithm to control blood pressure more rigorously with more stable haemodynamic profiles.

Read the detailed description

The incidence of maternal hypotension during spinal anaesthesia for Caesarean delivery is reported to be as high as 70-90%. The potential adverse effects resulting from maternal hypotension are nausea, vomiting, cardiac dysfunction, foetal acidosis and hypoxia.

Hypotension during spinal anaesthesia is currently detected using an intermittent blood pressure (BP) monitor cycling and reactive administration of vasopressors upon detection. The use of conventional non-invasive BP monitoring is limited by the time required to inflate and to deflate the cuffs commonly applied to the arm, which subsequently leads to a failure to react in a timely manner to BP changes when they occur.

The DIVA system (double-intravenous vasopressor automated system) previously developed helped tackle the limitations associated with the conventional management of hypotension in Caesarean sections under spinal anaesthesia. In a recent randomized controlled trial the DIVA system achieved less incidence of maternal hypotension compared to conventional management, however the side effects in mother and baby were still not fully eliminated.

In this proposed study a new algorithm for an advanced DIVA (ADIVA) system will be developed to control BP more rigorously by detecting BP with more stable haemodynamic profiles and thereby improve patient outcomes. The clinical trial will be conducted in 2 phases. The first phase included the use of ADIVA in 76 subjects who undergo spinal anaesthesia for Caesarean delivery to test its safety and efficacy. The second phase was a randomised controlled trial to investigate the use of ADIVA in comparison to the existing DIVA system in 97 patients undergoing spinal anaesthesia for Caesarean section.

Being tested
Phenylephrine, Ephedrine, ADIVA System, DIVA System
Keywords
Maternal hypotension, Spinal anaesthesia, Caesarean section
Medical subject headings
Hypotension

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • PhenylephrineDrug

    Also called Vasopressor

    Phenylephrine will be administered with conditions as below:

    1. When systolic blood pressure is between 90-110% of baseline, 25mcg phenylephrine will be given either in infusion or bolus if heart rate ≥ 60 beats/min;
    2. When systolic blood pressure is less than 90% of baseline, 25 to 75mcg phenylephrine will be given either in infusion or bolus if heart rate ≥ 60 beats/min.
  • EphedrineDrug

    Also called Vasopressor

    Ephedrine will be administered with conditions as below:

    1. When systolic blood pressure is between 90-110% of baseline, 2mg ephedrine will be given either in infusion or bolus if heart rate < 60 beats/min;
    2. When systolic blood pressure is less than 90% of baseline, 2 to 6mg ephedrine will be given either in infusion or bolus if heart rate < 60 beats/min.
  • ADIVA SystemDevice

    Also called Advanced Double Intravenous Vasopressor Automated System

    1. When systolic blood pressure (SBP) is 100-110% of baseline, 25mcg phenylephrine (infusion) is given if heart rate ≥ 60 beats/min, and 2mg ephedrine (infusion) is given if heart rate < 60 beats/min;
    2. When SBP is 90-100% of baseline, 25mcg phenylephrine (infusion or bolus) is given if heart rate ≥ 60 beats/min, and 2mg ephedrine (infusion or bolus) is given if heart rate < 60 beats/min;
    3. When SBP is 80-90% of baseline, 50mcg phenylephrine (infusion or bolus) is given if heart rate ≥ 60 beats/min, and 4mg ephedrine (infusion or bolus) is given if heart rate < 60 beats/min;
    4. When SBP < 80% of baseline, 75mcg phenylephrine (infusion or bolus) is given if heart rate ≥ 60 beats/min, and 6mg ephedrine (infusion or bolus) is given if heart rate < 60 beats/min.
  • DIVA SystemDevice

    Also called Double Intravenous Vasopressor Automated System

    DIVA system works as below:

    1. When systolic blood pressure is between 90 to 100% of baseline, 25mcg phenylephrine (bolus) will be given if heart rate ≥ 60 beats/min, whereas 2mg ephedrine (bolus) will be given if heart rate < 60 beats/min;
    2. When systolic blood pressure is less than 90% of baseline, 50mcg phenylephrine (infusion or bolus) will be given if heart rate ≥ 60 beats/min, whereas 4mg ephedrine (infusion or bolus) will be given if heart rate < 60 beats/min.
Study groups in NCT03620942
Study groupRoleWhat they receive
ADIVA systemExperimentalVasopressor delivery automated system administering phenylephrine and ephedrine using a three-step algorithm vasopressor delivery technique
Receives: Drug: Phenylephrine; Drug: Ephedrine; Device: ADIVA System
DIVA systemActive comparatorVasopressor delivery automated system administering phenylephrine and ephedrine using a two-step algorithm vasopressor delivery technique
Receives: Drug: Phenylephrine; Drug: Ephedrine; Device: DIVA System

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Number of events of Hypotension occurrence

    Systolic blood pressure less than 80% of baseline systolic blood pressure

    Measured: 1 day (during cesarean delivery)

Secondary outcomes (2)
  1. Number of events of Hypertension occurrence

    Systolic blood pressure more than 120% of baseline systolic blood pressure

    Measured: 1 day (during cesarean delivery)

  2. Number of events of Nausea and vomiting occurrence

    Nausea and vomiting during and after cesarean delivery

    Measured: 1 day (during and after cesarean delivery)

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted8 Aug 2018
  2. Study start7 Nov 2018
  3. Primary completion31 Dec 2026 (estimated)
  4. Study completion31 Dec 2027 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Model description
The first phase recruited 76 parturients. The second phase recruited 97 parturients. Parturients recruited from this phase will be randomized into either ADIVA group or DIVA group.
Masking
Double blind
Who is masked
Participant, Investigator
Enrolment
173 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03620942
Sponsor's protocol ID
SHF/CTG061/2017
Acronym
ADIVA
Status last verified
Aug 2026
First submitted
5 Aug 2018
Last updated
14 Aug 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Tan HS, Nagarajan S, Chan JJI, Tan CW, Sultana R, Sia ATH, Sng BL. Evaluating an advanced double intravenous vasopressor automated system to treat hypotension during spinal anesthesia for cesarean delivery: a randomized controlled trial. BMC Anesthesiol. 2023 Jan 26;23(1):33. doi: 10.1186/s12871-023-01992-7.

    PubMed 36703120
  • Nagarajan S, Chan JJI, Tan CW, Al-Hashim ZGA, Sultana R, Sia ATH, Sng BL. An advanced double intravenous vasopressor automated system to treat hypotension during spinal anaesthesia for caesarean section: A pilot study. Eur J Anaesthesiol. 2022 Jan 1;39(1):42-49. doi: 10.1097/EJA.0000000000001496.

    PubMed 33831901

Questions about this trial

What is this clinical trial studying?

A study testing Phenylephrine, Ephedrine and ADIVA System in people with Hypotension and Anesthesia, run by KK Women's and Children's Hospital at 1 site in Singapore.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: under way, not looking for participants, as of the sponsor's last update on 14 Aug 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Singapore. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

This study is still under way. Results are not available in the source record yet.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Number of events of Hypotension occurrence (time frame: 1 day (during cesarean delivery)). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03620942, which also lists 2 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 14 Aug 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in