CataractNCT03637348
Effect of TrueTear Corneal Surface Imaging
A study testing TrueTear in people with Cataract and Myopia, run by Price Vision Group at 1 site in United States.
Trial summary
This study will evaluate the utility of TrueTear™ to improve anterior corneal surface imaging quality before cataract surgery, refractive lens exchange, or laser refractive surgery. Read more about this study
- Who is it for?
- Ages 18 years and older
- What is being tested?
- TrueTear
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 45 participants
- Where
- 1 siteUnited States
- Study dates
- 13 Aug 2018to 8 Jul 2019
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Scheduled to undergo routine imaging for cataract surgery, refractive lens exchange or laser refractive surgery
Who cannot join
- A cardiac pacemaker, implanted or wearable defibrillator, or other implanted metallic or electronic device (e.g. cochlear implant) in the head or neck
- Chronic or frequent nosebleeds, a bleeding disorder (e.g. hemophilia), or another condition that can lead to increased bleeding
- A known hypersensitivity (allergy) to the hydrogel material that comes into contact with the inside of the nose during use of the TrueTearTM device
- Pregnancy
- Presence of any ocular disease or condition which in the investigator's opinion would confound the study results
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Effect of TrueTear Use on Anterior Corneal Surface Imaging Quality
This study will evaluate the utility of TrueTear™ to improve anterior corneal surface imaging quality before cataract surgery, refractive lens exchange, or laser refractive surgery.
Read the detailed description
Corneal imaging will be repeated before and after TrueTear use during a single patient visit. Image quality measures will be compared.
- Being tested
- TrueTear
- Medical subject headings
- Cataract, Myopia
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
TrueTearDevice
Ues of TrueTear neurostimulator
| Study group | Role | What they receive |
|---|---|---|
| TrueTear | Other | Use of TrueTear device to stimulate tear production Receives: Device: TrueTear |
What is being measured
The primary outcome is the main question the study is designed to answer.
Surface Asymmetry Index (SAI) Assessed With Corneal Topography
Surface asymmetry index (SAI) is an index that indicates an average value of the corneal power differences between the points spatially located at 180° from 128 equidistant meridians. A radially symmetrical surface has a value of zero, and this value increases as the degree of asymmetry is greater. Higher values are worse, but there is no set maximum value and no unit of measure.
Measured: Change from baseline SAI at 5-10 minutes after using the TrueTear device.
Secondary outcomes (1)
Surface Regularity Index (SRI) Assessed With Corneal Topography
Surface Regularity index (SRI) is a local descriptor of surface regularity in a central 4.5 mm diameter area of the cornea. It correlates well with the value of visual acuity (p = 0.80, P <0.001), assuming the cornea is the only limiting factor for vision. A normal cornea presents SRI values below 0.56 (the SRI would be 0 in a perfectly regular cornea). SRI values increase with increasing irregularity of the corneal surface. Higher values are worse, but there is no set maximum value and no unit of measure.
Measured: Change from baseline SRI at 5-10 minutes after using the TrueTear device.
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted20 Aug 2018
- Study start13 Aug 2018
- Primary completion8 Jul 2019
- Study completion8 Jul 2019
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Other trials for CataractStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 45 participants (actual)
Sponsor and investigators
- Lead sponsor
- Price Vision Group
- Sponsor type
- Industry (pharma, biotech, devices)
- Collaborators
- Allergan
- Responsible party
- Sponsor
- Investigators
- Francis W Price, Jr., MD, Principal investigator, Price Vision Group
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03637348
- Sponsor's protocol ID
- 2018-008
- Status last verified
- Jul 2020
- First submitted
- 3 Aug 2018
- Last updated
- 11 Aug 2020
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 11 Aug 2020. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Effect of TrueTear Use on Anterior Corneal Surface Imaging Quality
- ClinicalTrials.gov ID
- NCT03637348
- Acronym / sponsor ID
- 2018-008
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 45 participants (actual)
- Lead sponsor
- Price Vision GroupIndustry (pharma, biotech, devices)
- Collaborators
- Allergan
- Study start
- 13 Aug 2018 (actual)
- Primary completion
- 8 Jul 2019 (actual)
- Study completion
- 8 Jul 2019 (actual)
- First posted
- 20 Aug 2018 (actual)
- Results
- Posted 3 Aug 2020
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This study will evaluate the utility of TrueTear™ to improve anterior corneal surface imaging quality before cataract surgery, refractive lens exchange, or laser refractive surgery.
Detailed description
Corneal imaging will be repeated before and after TrueTear use during a single patient visit. Image quality measures will be compared.
Study design
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| TrueTear | Other | Device: TrueTearUse of TrueTear device to stimulate tear production |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (1 listed)
- Scheduled to undergo routine imaging for cataract surgery, refractive lens exchange or laser refractive surgery
Key exclusion criteria (5 listed)
- A cardiac pacemaker, implanted or wearable defibrillator, or other implanted metallic or electronic device (e.g. cochlear implant) in the head or neck
- Chronic or frequent nosebleeds, a bleeding disorder (e.g. hemophilia), or another condition that can lead to increased bleeding
- A known hypersensitivity (allergy) to the hydrogel material that comes into contact with the inside of the nose during use of the TrueTearTM device
- Pregnancy
- Presence of any ocular disease or condition which in the investigator's opinion would confound the study results
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| TrueTearUes of TrueTear neurostimulator | Device | TrueTear |
Primary outcome
Surface Asymmetry Index (SAI) Assessed With Corneal Topography
Time frame: Change from baseline SAI at 5-10 minutes after using the TrueTear device.
Surface asymmetry index (SAI) is an index that indicates an average value of the corneal power differences between the points spatially located at 180° from 128 equidistant meridians. A radially symmetrical surface has a value of zero, and this value increases as the degree of asymmetry is greater. Higher values are worse, but there is no set maximum value and no unit of measure.
1 secondary outcome
Surface Regularity Index (SRI) Assessed With Corneal Topography
Time frame: Change from baseline SRI at 5-10 minutes after using the TrueTear device.
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 11 Aug 2020.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Individual participant dataSharing planned: No
Related trials for Cataract
RecruitingObservational study
Capella Scientia Development Study
Cataract
Recruiting
Clareon TruPlus Study
Aphakia, Astigmatism
Active, not recruitingObservational study
Age-Related Eye Disease Study (AREDS) Follow-Up
Age-Related Macular Degeneration, Cataract
RecruitingObservational study
Anterior Segment Anatomy Assessed by Swept-Source OCT in Ocular Surgery Patients
Cataract, Primary Angle-Closure Glaucoma
RecruitingObservational study
Rare Disease Patient Registry & Natural History Study - Coordination of Rare Diseases at Sanford
Rare Disorders, Undiagnosed Disorders
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Francis W Price, Jr., MD principal investigator
Price Vision Group
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing TrueTear in people with Cataract and Myopia, run by Price Vision Group at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 11 Aug 2020. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 3 Aug 2020). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Surface Asymmetry Index (SAI) Assessed With Corneal Topography (time frame: Change from baseline SAI at 5-10 minutes after using the TrueTear device.). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 11 Aug 2020.