Hearing LossAB-ECOGNCT03685461
AB-Intra- and Post-Operative Measures of Auditory Function
A study testing Electrocochleography in people with Hearing Loss and Cochlear Implant, run by Medical College of Wisconsin at 1 site in United States.
Trial summary
The purpose of this study is to see how the inner ear responds to sound delivered to the ear canal during and after your cochlear implant surgery. This information may be helpful in telling us how well a cochlear implant performs after surgery. Read more about this study
- Who is it for?
- Ages 1 year and older
- Conditions the study is for
- Hearing Loss, Cochlear Implant
- What is being tested?
- Electrocochleography
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 88 participants
- Where
- 1 siteUnited States
- Study dates
- 1 Oct 2018to 1 Dec 2025
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 1 year and older
- All sexes
- No healthy volunteers
- Child, Adult, Older adult
Who may be able to join
- Pure-tone audiometry thresholds ≤80 dB HL at 500 Hz
- One year of age and older
- Normal candidacy requirements for cochlear implantation met
- No cochlear abnormality that might prevent full insertion of the CI electrode array
- No additional handicap that would prevent study procedures from being followed
Who cannot join
- Chronic otitis media
- Malformed cochlea
- Auditory neuropathy spectrum disorder (ANSD)
- Presence of ear tubes
- Prior middle ear surgeries or trauma including disruption of ossicles
Trial locations and contacts
1 site in 1 country.
United States1 site
Medical College of Wisconsin
Milwaukee, Wisconsin, 53226
About this study
The purpose of this study is to see how the inner ear responds to sound delivered to the ear canal during and after your cochlear implant surgery. This information may be helpful in telling us how well a cochlear implant performs after surgery.
Read the detailed description
Background and Objectives of the Study
Cochlear Implantation A cochlear implant (CI) is a prosthetic device for the inner ear that bypasses damaged inner ear hair cells and directly stimulates the auditory nerve, thereby providing audible sensations to patients with sensorineural hearing loss (SNHL). The implanted part consists of a hermetically sealed electronics package, a receiver coil which communicates with external components, and a magnet to help align the internal and external receiver coils. Attached to the implant package is the lead assembly that includes an array of electrode contacts that is inserted into the cochlea and interacts with its stimulable elements, the spiral ganglion cells and the cochlear hair cells. Today's CI models have between 12 and 22 intra-cochlear electrode contacts, each of which can be independently stimulated. In the healthy cochlea, different pitches are perceived at distinct locations along the length of the cochlea. This tono-topic organization is utilized when stimulating the cochlea electrically, as individual contacts can preferentially address neural populations associated with discrete regions of the cochlea. For example, when a low-pitched sound is captured by the microphone of the external sound processor, stimulation is routed to more apical electrodes, while for high-pitched sounds more basal electrode contacts are engaged.
Performance and Candidacy
Cochlear implants are currently the standard-of-care for patients with significant SNHL and poor speech understanding. Preservation of the delicate anatomy within the cochlea is well-known to correlate with hearing and speech understanding outcomes. During electrode insertion, it is common for the surgeon to make subtle adjustments to insertion parameters such as the angle of insertion or speed of insertion; such modifications are part of the standard-of-care of conventional CI surgery. The current state of conventional CI electrode insertion provides the surgeon with no feedback as to whether and when the delicate structures of the cochlea are damaged. Such a tool by which the surgeon can obtain real-time measurements of the electrophysiological function of the cochlea could help improve the current surgical procedure.
Electrocochleography
One means of achieving this level of feedback is using electrocochleography (ECochG). ECochG is an objective electrophysiological reflection of peripheral acoustic-electric interactions within the cochlea. ECochG devices are FDA cleared Class II devices. An example of a cleared device is the Otometrics device (k143670). The FDA 510(k) clearance letter for this device is provided (See Appendix). During ECochG measurement, a brief acoustic tone burst with a defined frequency and level is delivered to the external ear canal. This results in normal physiologic movements of the outer and the inner cochlear hair cells. These movements produce small electrical potentials that can be sensed by a recording electrode placed near the cochlea (e.g., historically, on the promontory or the round window). Averaging of these recordings in synchrony with the acoustic stimulus allows the small ECochG signal to be reinforced while any physiological or electrical noise is averaged out.
With ECochG measurements, the functional integrity of different elements of the peripheral auditory system can be examined. Specifically of interest, ECochG measurements can be resolved into the cochlear microphonic (CM) - generated by the cochlea's outer hair cells - and the auditory nerve neurophonic (ANN) - generated by the auditory nerve. By comparing the energy in the recorded signal at the measurement frequency with the noise floor of the measurement, behavioral hearing thresholds can be estimated with an accuracy of +/- 10 dB.
Real-Time ECochG monitoring
Advanced Bionics (AB), a manufacturer of FDA-approved CIs, has introduced a software approach to allow for utilization of ECochG during surgery. The prototype version of the AB-ECochG system has been successfully utilized in several clinical studies. The technological characteristics of the ECochG system utilized here are equivalent to existing FDA-approved systems.
This protocol will utilize the latest system under development from AB that enables data collection with sufficient speed and precision to provide real-time observations to the surgeon during CI electrode insertion.
Objectives
This investigation does not involve a novel CI or a modification of an existing implantable device. The CIs to be used in this study are physically and technologically unchanged and have current FDA approval (Ultra MS: Model# CI-1600-04, FDA PMA Approval Number P960058/S117; Ultra Slim J: Model# CI-1600-05, FDA PMA Approval Number P960058/S121). Utilization of the device in the diagnosis and treatment of disease (i.e., hearing loss) is also unchanged and consistent with existing FDA-approved indications.
ECochG systems themselves are not novel and have been in clinical use for many years. ECochG devices are FDA-cleared Class II devices. An FDA 510(k) clearance letter is provided (See Appendix). Use of ECochG for the purposes described here is consistent with indications covered under this FDA 510(k) clearance.
The objective of this study is to learn about how ECochG-based observations during conventional CI surgery can improve outcomes compared to the standard-of-care technique of blind electrode insertion. Two clinically relevant outcomes will be considered: post-operative electrode location (i.e., correct electrode placement within the scala tympani) and hearing performance (i.e., postoperative audiometric thresholds in clinic).
Significance
Compared with previous relevant work, whereby ECochG was recorded near the cochlea before and after CI electrode insertion, recording ECochG from the vantage point of the CI's apical electrode within the cochlea during CI electrode insertion has the advantage of closer proximity to the ECochG signal generators (i.e., cochlear hair cells and the acoustic nerve). This approach has been shown to result in larger amplitude recording, and, thereby, more immediate feedback to the surgeon should these potentials change. An added advantage of this method is that it does not involve any change to the CI device itself, to the way the device is used, or to the surgical technique to place the device.
The potential utility of ECochG during CI is illustrated by the following scenario: if the CI electrode touches the delicate structures of the cochlea (i.e., the basilar membrane or the spiral ligament) during insertion, the ECochG potentials become smaller in amplitude. With a real-time measurement system used during electrode insertion, decrease in ECochG potentials could be detected, and the surgeon could more purposely employ their modifications to insertion technique such as changing the insertion angle to avoid trauma or translocation.
Use of intra-cochlear electrodes for ECochG offers an additional capability of observing potentials post-operatively in the clinic. ECochG allows an objective method of monitoring hearing at regular intervals over the early post-operative period and may give insights into hearing outcomes.
Study Design
A prospective, randomized, multi-center controlled study design will be used in this study. The total study duration will be up to two years. This study will be conducted in agreement with the Internal Review Board (IRB). The study will be registered through Clinical Trials.gov (account created; IRB approved).
Outcome Measures
The post-operative outcome measures of this study will be (1) the CI electrode's scalar position as indicated by post-operative computed tomography (CT) and (2) post-operative hearing performance. Following the clinical convention, the surgeon will pre-operatively select the type of CI electrode (i.e., the MidScala electrode or the SlimJ electrode) that they would like to use during surgery. As detailed below, the patient will then be randomized to "audible ECochG signal off" or "audible ECochG signal on."
Hypotheses
The hypotheses of this study are that:
- Changes in the ECochG signal observed during CI electrode insertion will correlate with insertion position outcomes as indicated by post-operative CT scan.
- Participants randomized to "ECochG audible response on" will demonstrate a significantly lower rate of scalar dislocation compared to participants randomized to "ECochG audible response off."
- Changes in the ECochG signal during CI electrode insertion will correlate with post-operative audiogram.
- Post-operatively, changes in the ECochG signal over time in clinic will correlate with changes observed over time in post-operative audiograms.
Participants
In total, 192 participants will be included in this study. This sample size was determined by a power analysis, detailed below in Statistical Analysis.
Inclusion criteria are:
- Pure-tone audiometry thresholds ≤80 dB HL at 500 Hz
- One year of age and older
- Normal candidacy requirements for cochlear implantation met
- No cochlear abnormality that might prevent full insertion of the CI electrode array
- No additional handicap that would prevent study procedures from being followed
Exclusion criteria are:
- Chronic otitis media
- Malformed cochlea
- Auditory neuropathy spectrum disorder (ANSD)
- Presence of ear tubes
- Prior middle ear surgeries or trauma including disruption of ossicles
At any point in the study, the participants are free to end their involvement without any effect on their clinical care. Because this study does not involve any changes to the CI, its use, or the surgical technique, if a participant were to elect to end involvement in the study, it does not impact their treatment in any way. CI candidates meeting inclusion criteria will be given the opportunity to participate at the time of their regular pre-operative clinic visit or on the day of surgery itself.
Randomization
Interested CI candidates meeting study inclusion criteria will be randomized to one of two treatment arms. Randomization has been accomplished using a "randomized block design" to ensure that equal numbers of participants are included in each "treatment condition." For each participating institution, an impartially designed randomization schedule has been drawn up with the assistance of a biostatistician. The arm to which participants are randomized will be unknown to the investigators at the time of enrollment and to the participants themselves. By necessity, surgeons themselves will be "unblinded" on the day of surgery. Figure 1 depicts the study's randomization arms and post-operative outcome measures.
Arm 1: Audible ECochG Response Off
This condition is identical to the current standard-of-care for conventional CI surgery used worldwide. The surgeon will perform his or her electrode insertion without ECochG monitoring. Minute manipulations of the electrode are a normal part of conventional electrode insertion; manipulations such as redirecting the insertion vector or slowing down insertion speed will be made, as deemed necessary by the surgeon. A full electrode insertion will be performed, as appropriate. The ECochG responses will be recorded, but the surgeon will be blinded to this information during surgery.
Arm 2: Audible ECochG Response On
This condition will have the audible ECochG response on and available to the surgeon. In this condition, the surgeon perform a conventional electrode insertion while listening to the running ECochG signal for drop in amplitude (suggesting impending trauma). If no drop is detected, insertion will proceed to the full electrode length according to the standard-of-care. If an ECochG amplitude drop is observed, the surgeon will place this observation in its clinical context and evaluate insertion parameters, (i.e., insertion vector, insertion speed, etc.), customary practice with conventional CI surgery, but here supplemented by the ECochG response. In the case of an ECochG amplitude drop that does not recover, the standard-of-care practice of achieving a full electrode insertion will be followed.
Protocol timeline
- Pre-Operative (typically 1-30 days before surgery)
- Standard counselling regarding CI study; collect consent form for adults or assent form for pediatric participants; collect data release forms.
- The surgeon makes his or her CI electrode selection between two options: (1) the HiFocus SlimJ (lateral wall array) or (2) the HiFocus MidScala. Electrode selection is a normal component of conventional CI surgery. All CIs models to be utilized in this study are FDA-approved and will be used within their approved indications (Ultra MS: Model# CI-1600-04, FDA PMA Approval Number P960058/S117; Ultra Slim J: Model# CI-1600-05, FDA PMA Approval Number P960058/S121).
- Pure tone audiometry (standard-of-care pre-operative CI candidacy evaluation). In pediatric patients, for whom completion of pure tone audiometry may be difficult or unreliable, auditory brainstem response (ABR) testing can be used to supplement or estimate behavioural thresholds.
- Pre-operative CT scan (standard-of-care) for surgical planning.
- Day of surgery
- Ensure that no cerumen or surgical preparation fluid is in the external ear canal. Place the ear piece in the external ear canal and fold the pinna forward, as in the conventional procedure.
- Enter the pre-op audiogram into the software.
- Normal CI surgical approach. A conventional round window or extended round window entry into the cochlea is prepared.
- Measure ECochG in response to a 500 Hz tone burst stimulus, at 110 dB SPL, during insertion of the CI electrode and after insertion of the CI electrode. Figure 2 schematically depicts the intraoperative set-up. Figure 3 shows the non-invasive surface electrode and earphone array used in ECochG. Figure 4 shows the enclosure box and monitoring screen.
- For participants randomized to Arm 1 of the study, the surgeon will perform CI electrode insertion without ECochG feedback. ii) For participants randomized to Arm 2 of the study, the surgeon will make insertion modifications as appropriate in response to ECochG feedback.
- Initial CI Activation Visit (3-5 weeks after surgery)
- Audio Assessment i) Unaided pure tone audiometry in the implanted and the unimplanted ear ii) Bone-conduction thresholds when possible, depending on the patient's residual hearing status iii) For pediatric patients, unaided audiometric data may be collected as tolerated, across different visits, to accommodate the unique challenges of hearing assessment of young children.
- Measure ECochG responses in clinic (to coincide with audiometry, +/- 1 week) i) 125-2000 Hz (frequency scan) ii) At an acoustic intensity level at or below their comfortable level through an insert earphone iii) Directly through the CI c) Post-Op CT scan to identify CI electrode scalar location i) Obtain scan within one month following surgery ii) Patient identifiers removed from CT scan data and sent to collaborators in DICOM format for analysis (See Appendix 1).
- Approximately 3 Month Visit
- Audio Assessment i) Pure tone unaided audiometry in the implanted and the unimplanted ear ii) Bone-conduction thresholds when possible, depending on the patient's residual hearing status b) Measure ECochG responses in clinic (to coincide with audiometry, +/- 1 week) i) 125-2000 Hz (frequency scan) ii) At an acoustic intensity level at or below their comfortable level through an insert earphone iii) Directly through the CI
- Approximately 12 Month Visit a) Audio Assessment i) Pure tone unaided audiometry in the implanted and the unimplanted ear ii) Bone-conduction thresholds as appropriate b) Measure ECochG responses in clinic (to coincide with audiometry, +/- 1 week) i) 125-2000 Hz frequency scan ii) At an acoustic intensity level at or below their comfortable level through an insert earphone iii) Directly through the CI Detailed description of measurements and procedure Pure tone and bone-conduction audiometry Pure tone audiometry will be performed following the conventional, routine protocol currently in place for determining CI candidacy. Where possible, pure tone thresholds will be established in the implanted ear for 125, 250, 500, 750, 1000, 1500, 2000, 3000, 4000, 6000, and 8000 Hz. Testing will be conducted using insert earphones, and where indicated, the contralateral ear will be masked. Both the implanted and the non-implanted ear will be measured. If clinically appropriate, bone-conduction testing will be performed as well following conventional practices. For young children in our cohort, for whom hearing testing can be uniquely challenging, thresholds obtained across more than one visit will be permitted and thresholds may be estimated base on auditory brainstem response (ABR) testing.
In line with the Minimum Reporting Standards for Adult Cochlear Implantation recommendations, in patients with functionally relevant pre-operative low frequency pure tone averages (125, 250, 500 Hz) < 80 dB HL, post-operative residual hearing will be reported. Each frequency will be reported individually (125, 250, 500, 1000, 1500, 2000, 4000, and 8000 Hz) rather than as a pure tone average.
Electrocochleography
In the operating room, a 500 Hz tone burst will be presented to the participant at a 110 dB SPL through an insert earphone in the external auditory canal. This acoustic stimulus will provoke movements of remaining inner and outer cochlear hair cells and evoke a response from the auditory nerve. Tone burst stimuli at 500 Hz have been shown to produce the largest amplitude ECochG response, therefore, will be used as the default stimulus here. The resulting cochlear potentials will be recorded using the recording electrode from the apical aspect of the CI electrode. By averaging the recorded signal synchronized with stimulus delivery, the responses can be reinforced while unsynchronized noise will average out. This utilization is consistent with indications covered under this FDA 510(k) clearance.
Intra-operative preparation
The insert earphone will be placed in the external ear canal after cerumen removal. The ear canal will be surgically prepared, followed by suctioning of prep fluid. Following the conventional technique, the measurement ear will be folded forward and taped. The surgery will proceed following the standard-of-care practice consisting of a cortical mastoidectomy, a facial recess (posterior tympanotomy), and preparation of intracochlear access via the round window or an extended round window approach. Before the CI electrode will be inserted, the headpiece will be connected to the implant, and the ECochG software will be triggered to begin the ECochG recordings. Figure 2 depicts a schematic of the measurement system setup. Figure 3 shows an example of the noninvasive surface electrode and earphone array. Figure 4 shows the monitor and unit through which the ECochG is observed and recorded.
To facilitate correlation of changes in ECochG potentials during CI electrode insertion and surgical events that ultimately relate to trauma within the cochlea, the surgeon will verbally indicate the progress of electrode insertion (e.g., "at the round window," "at the first marker on the electrode," "at the last marker on the electrode"), which will be recorded in the software by an assistant and synched with the ECochG signals.
Post-operative ECochG
For post-operative ECochG measurements in the clinic, the setup depicted in Figure 3 will be utilized. For this testing, the external component of the CI will be temporarily removed (equivalent to simply taking off a hearing aid) and replaced with an external head coil component (physically identical to the CI's external head coil) that allows for ECochG measurement. After connecting the head piece, a frequency scan from 125-2000 Hz will be presented to the participant at an acoustic intensity level at or below their comfortable listening level through an insert earphone in the external auditory canal. After measurements are collected, the participant's own external component will be put back in place. This measurement takes up to 5 minutes and does not require active participation of the participant.
CT Scan
A single post-operative CT scan will be conducted to identify the electrode's scalar location. A post-operative CT scan is often performed as a part of the regular clinical routine in patients for whom more information about the CI electrode location is needed. The post-operative CT will be collected per parameters outlined in Appendix 1.
Risks
The chief risks associated with this study are those inherent to CI surgery itself. The use of intraoperative ECochG has been well-demonstrated to pose no added patient risks, but may, as discussed above, provide an important benefit. Participation in this study will involve the following specific considerations:
- Increased surgical time: The ECochG measurement procedure adds up to 5-15 minutes to the procedure. During this added procedure time, the Anesthesia team will closely monitor the patient. If there are any concerns at any time, the study activity will be ceased.
- Post-operative CT scan: Associated radiation exposure. The implant, sound processor, and the clinical programming interface (CPI) hardware are all FDA-approved, and their use in the study is not associated with any additional risk to the patient. ECochG devices are FDA-cleared Class II devices. For an example of an FDA 510(k) clearance letter for the Otometrics device (k143670), please see Appendix. The ECochG recording software is not FDA/Conformité Européenne (CE) certified, but it has been thoroughly tested per AB's internal quality system. The recording software is not part of the CI operation and does not introduce any new or changed risk to the patient. It has been verified that the experimental software does not affect the performance of the FDA-approved software or hardware. Further, the entire protocol detailed above has been utilized and reported upon across several institutions validating the feasibility, ease, and safety of this modification to the convention "no feedback" approach to CI electrode insertion. This study's principal investigator (PI) also has experience using the current system.
Data Acquisition and Storage
Post-operative audiometric measurements and post-operative CT scan results will be recorded in the participant's study binder. Results of intra-operative and post-operative ECochG will be saved by the ECochG software program but will also be printed and kept in the participant's binder. All files will be archived. The main study results will be transferred to Excel-files for analysis. Further analyses will be done with Excel, Matlab or statistical software packages. A member of the Biostatistics Department will assist in statistical analysis. All results will be made anonymous prior to being shown to any third party. It will not be possible for any individual study participant to be recognized from his or her study data.
In addition, we will compare ECochG-based predictions associated with CI electrode scalar position and hearing outcomes to predications made based on conventional demographic and audiometric data. To facilitate multivariate analysis, we will extract biographical (e.g., age, etiology of hearing loss, duration of deafness) and surgical (e.g., device and electrode type) factors from the electronic medical record.
Statistical Analysis
Randomization
Block randomization is statistical strategy to prevent unequal numbers of participants from being randomized to one arm vs the other (here, audible signal "on" versus audible signal "off"). For example, using a random number generator set to individually assign 100 participants to one of two groups, there is no assurance that an equal numbers of study participants would end up in the "audible signal on" group, resulting in an unbalanced overall sample, despite randomization of each participant.
Using a block approach, the total sample is divided into smaller blocks and randomization is performed within each block with the rule that the number of allocations is balanced within that block. In our study, although each institution will likely only contribute about 40 participants, we have designed a randomization schedule to allow for 100 participants to be run for each program. This sample of 100 was divided into 50 blocks of two participants; the two participants are randomized ensuring that one goes into the "signal off" group and one goes to the "signal on" group.
Power Analysis
To ensure that our study is appropriately powered to detect a significant difference in the primary outcomes measures, we performed a power analysis with the assistance of a biostatistician. Post-operative CT-based indication of scalar position is treated as a dichotomous variable (i.e., either in the scala tympani or in the scala vestibuli); post-operative hearing outcomes are treated as a continuous variable.
Scalar Dislocation: Preliminary data indicates that the current state of CI electrode dislocation from the scala tympani to the scala vestibuli is approximately 35% (or, a "successful" scala tympani position is achieved at a rate of 65%). For participants randomized to "ECochG audible signal on," our expectation, driven by preliminary data, is to decrease the rate of scalar dislocation to approximately 15% (or, a "successful" scala tympani position rate of 85%). Setting the alpha error rate at 2.5%, a total sample size of 192 participants, or 96 participants in each of the two randomization groups, was determined using a Fischer exact test. If we permit a 5% error rate, the total sample size drops to 162 patients (81 randomized to audible signal "on"; 81 randomized to signal "off"). While these numbers of participants are higher than would be possible to achieve at our site alone in an average two-year period, through a coordinated effort to pool multi-center data, it will be easily achievable.
Secondary Planned Analysis
Electrode Type: As detailed above, once a participant is enrolled in the study, the surgeon will select which of two CI electrodes are most appropriate. A secondary analysis comparing scalar position and hearing preservation outcomes will be performed (i.e., four total between-group analyses) between the two electrode groups.
Pediatric Participants: This study will include both adult and pediatric participants. A secondary analysis comparing scalar position and hearing outcomes between adult and pediatric participants will be performed (again, four total between-group analyses).
Regression Analysis: To model the influence of "ECochG on" on the primary outcome measures in the context of participant age group and electrode choice, two regression analyses will be performed - one for the outcome measure of scalar position and one for hearing outcomes.
Hospital Effect Analysis: To determine if there is a meaningful difference in outcome measures across the different participating hospital settings, a secondary analysis will be performed as well.
Safeguarding of Protected Health Information (PHI) Upon study enrollment, participants will be assigned an alphanumeric code that will be used to track their data. A code key will be maintained by the investigators on a secure server and accessed using password-protected computers located in a locked office in a secure research space. Participant identity cannot be discovered from ECochG data. Likewise, CT images and audiometric data will not reveal participant identity and will be made fully anonymous prior to sharing with any third party. Participant study binders, labeled using their alphanumeric code only, will be stored in a locked cabinet, in a locked office, in a secure research area accessible only to the investigators.
- Conditions
- Hearing Loss, Cochlear Implant
- Being tested
- Electrocochleography
- Keywords
- Hearing Loss, Cochlear Implant
- Medical subject headings
- Hearing Loss
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
ElectrocochleographyOther
Also called ECochG
Electrocochleography is a noninvasive method of monitoring for acoustic evoked electrophysiologic responses from the cochlea. A speaker in the external auditory canal presents a tone burst stimulus and a nearby electrode, in this case from the apical electrode of the cochlear implant, records changes in the electrical activity within the cochlea. Different functional elements within the cochlea have signature electrophysiologic responses that can be isolated and studied individually. Through the use of intracochlear electrocochleography during cochlear implant electrode insertion valuable insight can be gained about structural or physiological changes that may be occurring.
| Study group | Role | What they receive |
|---|---|---|
| Arm 1: Audible ECochG Response Off | Other | Arm 1: Audible ECochG Response Off This condition is identical to the current standard-of-care for conventional CI surgery used worldwide. The surgeon will perform his or her electrode insertion without ECochG monitoring. Minute manipulations of the electrode are a normal part of conventional electrode insertion; manipulations such as redirecting the insertion vector or slowing down insertion speed will be made, as deemed necessary by the surgeon. A full electrode insertion will be performed, as appropriate. The ECochG responses will be recorded, but the surgeon will be blinded to this information during surgery. Receives: Other: Electrocochleography |
| Arm 2: Audible ECochG Response On | Experimental | This condition will have the audible ECochG response on and available to the surgeon. In this condition, the surgeon perform a conventional electrode insertion while listening to the running ECochG signal for drop in amplitude (suggesting impending trauma). If no drop is detected, insertion will proceed to the full electrode length according to the standard-of-care. If an ECochG amplitude drop is observed, the surgeon will place this observation in its clinical context and evaluate insertion parameters, (i.e., insertion vector, insertion speed, etc.), customary practice with conventional CI surgery, but here supplemented by the ECochG response. In the case of an ECochG amplitude drop that does not recover, the standard-of-care practice of achieving a full electrode insertion will be followed. Receives: Other: Electrocochleography |
What is being measured
The primary outcome is the main question the study is designed to answer.
The CI electrode's scalar position as indicated by post-operative computed tomography (CT)
Following cochlear implant surgery a CT scan, optimized for resolution of the CI electrode, will be obtained. This will be merged with routine clinically acquired pre-operative imaging to determine which of the scala the electrode sides in and whether or not there has been any translocation from one scala into another.
Measured: To be performed within one month of cochlear implantation
Secondary outcomes (1)
Post-operative hearing performance
Post-operative pure tone audiometry will be obtained and compared to preoperative pure tone audiometry to determine the degree of hearing preservation or loss of residual hearing that has been achieved.
Measured: To be collected at post-op clinical visits until 12 months post-op
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted26 Sep 2018
- Study start1 Oct 2018
- Primary completion31 Jul 2025
- Study completion1 Dec 2025
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (13)Papers the sponsor has linked to this study.
- Other trials for Hearing LossStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Other
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Model description
- Sample of cochlear implant recipients. Half randomized for observation with ECOchG on, half randomized to ECochG off
- Masking
- Double blind
- Who is masked
- Participant, Outcomes assessor
- Enrolment
- 88 participants (actual)
Sponsor and investigators
- Lead sponsor
- Medical College of Wisconsin
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Michael Harris, Medical College of Wisconsin
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03685461
- Sponsor's protocol ID
- PRO00032101
- Acronym
- AB-ECOG
- Status last verified
- Jan 2026
- First submitted
- 18 Sep 2018
- Last updated
- 14 Jan 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
Publications
Lehnhardt E. [Placement of intracochlear electrodes with Healon]. HNO. 1992 Mar;40(3):86-9. German.
PubMed 1577630Rogowski M, Reiss G, Lehnhardt E. Morphologic study of the guinea pig cochlea after cochlear implantation using the "soft surgery" technique. Ann Otol Rhinol Laryngol Suppl. 1995 Sep;166:434-6.
PubMed 7668741Gstoettner W, Hamzavi J, Franz P, Plenk H Jr, Czerny C, Susani M, Adunka O, Baumgartner WD. [Intracochlear position of cochlear implant electrodes]. Wien Klin Wochenschr. 2000 Jun 2;112(11):477-80. German.
PubMed 10890124Lenarz T, Stover T, Buechner A, Lesinski-Schiedat A, Patrick J, Pesch J. Hearing conservation surgery using the Hybrid-L electrode. Results from the first clinical trial at the Medical University of Hannover. Audiol Neurootol. 2009;14 Suppl 1:22-31. doi: 10.1159/000206492. Epub 2009 Apr 22.
PubMed 19390172Incerti PV, Ching TY, Cowan R. A systematic review of electric-acoustic stimulation: device fitting ranges, outcomes, and clinical fitting practices. Trends Amplif. 2013 Mar;17(1):3-26. doi: 10.1177/1084713813480857.
PubMed 23539259Lenarz T, James C, Cuda D, Fitzgerald O'Connor A, Frachet B, Frijns JH, Klenzner T, Laszig R, Manrique M, Marx M, Merkus P, Mylanus EA, Offeciers E, Pesch J, Ramos-Macias A, Robier A, Sterkers O, Uziel A. European multi-centre study of the Nucleus Hybrid L24 cochlear implant. Int J Audiol. 2013 Dec;52(12):838-48. doi: 10.3109/14992027.2013.802032. Epub 2013 Sep 2.
PubMed 23992489Aschendorff A, Kromeier J, Klenzner T, Laszig R. Quality control after insertion of the nucleus contour and contour advance electrode in adults. Ear Hear. 2007 Apr;28(2 Suppl):75S-79S. doi: 10.1097/AUD.0b013e318031542e.
PubMed 17496653Finley CC, Holden TA, Holden LK, Whiting BR, Chole RA, Neely GJ, Hullar TE, Skinner MW. Role of electrode placement as a contributor to variability in cochlear implant outcomes. Otol Neurotol. 2008 Oct;29(7):920-8. doi: 10.1097/MAO.0b013e318184f492.
PubMed 18667935Mandala M, Colletti L, Tonoli G, Colletti V. Electrocochleography during cochlear implantation for hearing preservation. Otolaryngol Head Neck Surg. 2012 May;146(5):774-81. doi: 10.1177/0194599811435895. Epub 2012 Jan 30.
PubMed 22291043Eggermont JJ. Ups and Downs in 75 Years of Electrocochleography. Front Syst Neurosci. 2017 Jan 24;11:2. doi: 10.3389/fnsys.2017.00002. eCollection 2017.
PubMed 28174524Koka K, Saoji AA, Litvak LM. Electrocochleography in Cochlear Implant Recipients With Residual Hearing: Comparison With Audiometric Thresholds. Ear Hear. 2017 May/Jun;38(3):e161-e167. doi: 10.1097/AUD.0000000000000385.
PubMed 27879487Adunka OF, Gantz BJ, Dunn C, Gurgel RK, Buchman CA. Minimum Reporting Standards for Adult Cochlear Implantation. Otolaryngol Head Neck Surg. 2018 Aug;159(2):215-219. doi: 10.1177/0194599818764329. Epub 2018 Mar 20.
PubMed 29557283Harris MS, Koka K, Thompson-Harvey A, Harvey E, Riggs WJ, Saleh S, Holder JT, Dwyer RT, Prentiss SM, Lefler SM, Kozlowski K, Hiss MM, Ortmann AJ, Nelson-Bakkum ER, Buchner A, Salcher R, Harvey SA, Hoffer ME, Bohorquez JE, Alzhrani F, Alshihri R, Almuhawas F, Danner CJ, Friedland DR, Seidman MD, Lenarz T, Telischi FF, Labadie RF, Buchman CA, Adunka OF. Amplitude Parameters Are Predictive of Hearing Preservation in a Randomized Controlled Trial of Intracochlear Electrocochleography During Cochlear Implant Surgery. Otol Neurotol. 2024 Sep 1;45(8):887-894. doi: 10.1097/MAO.0000000000004286. Epub 2024 Jul 25.
PubMed 39052893
Study at a glance
From the registry record, last updated by the sponsor on 14 Jan 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- AB-Intra- and Post-Operative Measures of Auditory Function
- ClinicalTrials.gov ID
- NCT03685461
- Acronym / sponsor ID
- AB-ECOG / PRO00032101
- Conditions
- Hearing Loss, Cochlear Implant
- Keywords
- Hearing Loss, Cochlear Implant
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 88 participants (actual)
- Lead sponsor
- Medical College of WisconsinUniversity, hospital or other
- Study start
- 1 Oct 2018 (actual)
- Primary completion
- 31 Jul 2025 (actual)
- Study completion
- 1 Dec 2025 (actual)
- First posted
- 26 Sep 2018 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The purpose of this study is to see how the inner ear responds to sound delivered to the ear canal during and after your cochlear implant surgery. This information may be helpful in telling us how well a cochlear implant performs after surgery.
Detailed description
Background and Objectives of the Study
Cochlear Implantation A cochlear implant (CI) is a prosthetic device for the inner ear that bypasses damaged inner ear hair cells and directly stimulates the auditory nerve, thereby providing audible sensations to patients with sensorineural hearing loss (SNHL). The implanted part consists of a hermetically sealed electronics package, a receiver coil which communicates with external components, and a magnet to help align the internal and external receiver coils. Attached to the implant package is the lead assembly that includes an array of electrode contacts that is inserted into the cochlea and interacts with its stimulable elements, the spiral ganglion cells and the cochlear hair cells. Today's CI models have between 12 and 22 intra-cochlear electrode contacts, each of which can be independently stimulated. In the healthy cochlea, different pitches are perceived at distinct locations along the length of the cochlea. This tono-topic organization is utilized when stimulating the cochlea electrically, as individual contacts can preferentially address neural populations associated with discrete regions of the cochlea. For example, when a low-pitched sound is captured by the microphone of the external sound processor, stimulation is routed to more apical electrodes, while for high-pitched sounds more basal electrode contacts are engaged.
Performance and Candidacy
Cochlear implants are currently the standard-of-care for patients with significant SNHL and poor speech understanding. Preservation of the delicate anatomy within the cochlea is well-known to correlate with hearing and speech understanding outcomes. During electrode insertion, it is common for the surgeon to make subtle adjustments to insertion parameters such as the angle of insertion or speed of insertion; such modifications are part of the standard-of-care of conventional CI surgery. The current state of conventional CI electrode insertion provides the surgeon with no feedback as to whether and when the delicate structures of the cochlea are damaged. Such a tool by which the surgeon can obtain real-time measurements of the electrophysiological function of the cochlea could help improve the current surgical procedure.
Electrocochleography
One means of achieving this level of feedback is using electrocochleography (ECochG). ECochG is an objective electrophysiological reflection of peripheral acoustic-electric interactions within the cochlea. ECochG devices are FDA cleared Class II devices. An example of a cleared device is the Otometrics device (k143670). The FDA 510(k) clearance letter for this device is provided (See Appendix). During ECochG measurement, a brief acoustic tone burst with a defined frequency and level is delivered to the external ear canal. This results in normal physiologic movements of the outer and the inner cochlear hair cells. These movements produce small electrical potentials that can be sensed by a recording electrode placed near the cochlea (e.g., historically, on the promontory or the round window). Averaging of these recordings in synchrony with the acoustic stimulus allows the small ECochG signal to be reinforced while any physiological or electrical noise is averaged out.
With ECochG measurements, the functional integrity of different elements of the peripheral auditory system can be examined. Specifically of interest, ECochG measurements can be resolved into the cochlear microphonic (CM) - generated by the cochlea's outer hair cells - and the auditory nerve neurophonic (ANN) - generated by the auditory nerve. By comparing the energy in the recorded signal at the measurement frequency with the noise floor of the measurement, behavioral hearing thresholds can be estimated with an accuracy of +/- 10 dB.
Real-Time ECochG monitoring
Advanced Bionics (AB), a manufacturer of FDA-approved CIs, has introduced a software approach to allow for utilization of ECochG during surgery. The prototype version of the AB-ECochG system has been successfully utilized in several clinical studies. The technological characteristics of the ECochG system utilized here are equivalent to existing FDA-approved systems.
This protocol will utilize the latest system under development from AB that enables data collection with sufficient speed and precision to provide real-time observations to the surgeon during CI electrode insertion.
Objectives
This investigation does not involve a novel CI or a modification of an existing implantable device. The CIs to be used in this study are physically and technologically unchanged and have current FDA approval (Ultra MS: Model# CI-1600-04, FDA PMA Approval Number P960058/S117; Ultra Slim J: Model# CI-1600-05, FDA PMA Approval Number P960058/S121). Utilization of the device in the diagnosis and treatment of disease (i.e., hearing loss) is also unchanged and consistent with existing FDA-approved indications.
ECochG systems themselves are not novel and have been in clinical use for many years. ECochG devices are FDA-cleared Class II devices. An FDA 510(k) clearance letter is provided (See Appendix). Use of ECochG for the purposes described here is consistent with indications covered under this FDA 510(k) clearance.
The objective of this study is to learn about how ECochG-based observations during conventional CI surgery can improve outcomes compared to the standard-of-care technique of blind electrode insertion. Two clinically relevant outcomes will be considered: post-operative electrode location (i.e., correct electrode placement within the scala tympani) and hearing performance (i.e., postoperative audiometric thresholds in clinic).
Significance
Compared with previous relevant work, whereby ECochG was recorded near the cochlea before and after CI electrode insertion, recording ECochG from the vantage point of the CI's apical electrode within the cochlea during CI electrode insertion has the advantage of closer proximity to the ECochG signal generators (i.e., cochlear hair cells and the acoustic nerve). This approach has been shown to result in larger amplitude recording, and, thereby, more immediate feedback to the surgeon should these potentials change. An added advantage of this method is that it does not involve any change to the CI device itself, to the way the device is used, or to the surgical technique to place the device.
The potential utility of ECochG during CI is illustrated by the following scenario: if the CI electrode touches the delicate structures of the cochlea (i.e., the basilar membrane or the spiral ligament) during insertion, the ECochG potentials become smaller in amplitude. With a real-time measurement system used during electrode insertion, decrease in ECochG potentials could be detected, and the surgeon could more purposely employ their modifications to insertion technique such as changing the insertion angle to avoid trauma or translocation.
Use of intra-cochlear electrodes for ECochG offers an additional capability of observing potentials post-operatively in the clinic. ECochG allows an objective method of monitoring hearing at regular intervals over the early post-operative period and may give insights into hearing outcomes.
Study Design
A prospective, randomized, multi-center controlled study design will be used in this study. The total study duration will be up to two years. This study will be conducted in agreement with the Internal Review Board (IRB). The study will be registered through Clinical Trials.gov (account created; IRB approved).
Outcome Measures
The post-operative outcome measures of this study will be (1) the CI electrode's scalar position as indicated by post-operative computed tomography (CT) and (2) post-operative hearing performance. Following the clinical convention, the surgeon will pre-operatively select the type of CI electrode (i.e., the MidScala electrode or the SlimJ electrode) that they would like to use during surgery. As detailed below, the patient will then be randomized to "audible ECochG signal off" or "audible ECochG signal on."
Hypotheses
The hypotheses of this study are that:
- Changes in the ECochG signal observed during CI electrode insertion will correlate with insertion position outcomes as indicated by post-operative CT scan.
- Participants randomized to "ECochG audible response on" will demonstrate a significantly lower rate of scalar dislocation compared to participants randomized to "ECochG audible response off."
- Changes in the ECochG signal during CI electrode insertion will correlate with post-operative audiogram.
- Post-operatively, changes in the ECochG signal over time in clinic will correlate with changes observed over time in post-operative audiograms.
Participants
In total, 192 participants will be included in this study. This sample size was determined by a power analysis, detailed below in Statistical Analysis.
Inclusion criteria are:
- Pure-tone audiometry thresholds ≤80 dB HL at 500 Hz
- One year of age and older
- Normal candidacy requirements for cochlear implantation met
- No cochlear abnormality that might prevent full insertion of the CI electrode array
- No additional handicap that would prevent study procedures from being followed
Exclusion criteria are:
- Chronic otitis media
- Malformed cochlea
- Auditory neuropathy spectrum disorder (ANSD)
- Presence of ear tubes
- Prior middle ear surgeries or trauma including disruption of ossicles
At any point in the study, the participants are free to end their involvement without any effect on their clinical care. Because this study does not involve any changes to the CI, its use, or the surgical technique, if a participant were to elect to end involvement in the study, it does not impact their treatment in any way. CI candidates meeting inclusion criteria will be given the opportunity to participate at the time of their regular pre-operative clinic visit or on the day of surgery itself.
Randomization
Interested CI candidates meeting study inclusion criteria will be randomized to one of two treatment arms. Randomization has been accomplished using a "randomized block design" to ensure that equal numbers of participants are included in each "treatment condition." For each participating institution, an impartially designed randomization schedule has been drawn up with the assistance of a biostatistician. The arm to which participants are randomized will be unknown to the investigators at the time of enrollment and to the participants themselves. By necessity, surgeons themselves will be "unblinded" on the day of surgery. Figure 1 depicts the study's randomization arms and post-operative outcome measures.
Arm 1: Audible ECochG Response Off
This condition is identical to the current standard-of-care for conventional CI surgery used worldwide. The surgeon will perform his or her electrode insertion without ECochG monitoring. Minute manipulations of the electrode are a normal part of conventional electrode insertion; manipulations such as redirecting the insertion vector or slowing down insertion speed will be made, as deemed necessary by the surgeon. A full electrode insertion will be performed, as appropriate. The ECochG responses will be recorded, but the surgeon will be blinded to this information during surgery.
Arm 2: Audible ECochG Response On
This condition will have the audible ECochG response on and available to the surgeon. In this condition, the surgeon perform a conventional electrode insertion while listening to the running ECochG signal for drop in amplitude (suggesting impending trauma). If no drop is detected, insertion will proceed to the full electrode length according to the standard-of-care. If an ECochG amplitude drop is observed, the surgeon will place this observation in its clinical context and evaluate insertion parameters, (i.e., insertion vector, insertion speed, etc.), customary practice with conventional CI surgery, but here supplemented by the ECochG response. In the case of an ECochG amplitude drop that does not recover, the standard-of-care practice of achieving a full electrode insertion will be followed.
Protocol timeline
- Pre-Operative (typically 1-30 days before surgery)
- Standard counselling regarding CI study; collect consent form for adults or assent form for pediatric participants; collect data release forms.
- The surgeon makes his or her CI electrode selection between two options: (1) the HiFocus SlimJ (lateral wall array) or (2) the HiFocus MidScala. Electrode selection is a normal component of conventional CI surgery. All CIs models to be utilized in this study are FDA-approved and will be used within their approved indications (Ultra MS: Model# CI-1600-04, FDA PMA Approval Number P960058/S117; Ultra Slim J: Model# CI-1600-05, FDA PMA Approval Number P960058/S121).
- Pure tone audiometry (standard-of-care pre-operative CI candidacy evaluation). In pediatric patients, for whom completion of pure tone audiometry may be difficult or unreliable, auditory brainstem response (ABR) testing can be used to supplement or estimate behavioural thresholds.
- Pre-operative CT scan (standard-of-care) for surgical planning.
- Day of surgery
- Ensure that no cerumen or surgical preparation fluid is in the external ear canal. Place the ear piece in the external ear canal and fold the pinna forward, as in the conventional procedure.
- Enter the pre-op audiogram into the software.
- Normal CI surgical approach. A conventional round window or extended round window entry into the cochlea is prepared.
- Measure ECochG in response to a 500 Hz tone burst stimulus, at 110 dB SPL, during insertion of the CI electrode and after insertion of the CI electrode. Figure 2 schematically depicts the intraoperative set-up. Figure 3 shows the non-invasive surface electrode and earphone array used in ECochG. Figure 4 shows the enclosure box and monitoring screen.
- For participants randomized to Arm 1 of the study, the surgeon will perform CI electrode insertion without ECochG feedback. ii) For participants randomized to Arm 2 of the study, the surgeon will make insertion modifications as appropriate in response to ECochG feedback.
- Initial CI Activation Visit (3-5 weeks after surgery)
- Audio Assessment i) Unaided pure tone audiometry in the implanted and the unimplanted ear ii) Bone-conduction thresholds when possible, depending on the patient's residual hearing status iii) For pediatric patients, unaided audiometric data may be collected as tolerated, across different visits, to accommodate the unique challenges of hearing assessment of young children.
- Measure ECochG responses in clinic (to coincide with audiometry, +/- 1 week) i) 125-2000 Hz (frequency scan) ii) At an acoustic intensity level at or below their comfortable level through an insert earphone iii) Directly through the CI c) Post-Op CT scan to identify CI electrode scalar location i) Obtain scan within one month following surgery ii) Patient identifiers removed from CT scan data and sent to collaborators in DICOM format for analysis (See Appendix 1).
- Approximately 3 Month Visit
- Audio Assessment i) Pure tone unaided audiometry in the implanted and the unimplanted ear ii) Bone-conduction thresholds when possible, depending on the patient's residual hearing status b) Measure ECochG responses in clinic (to coincide with audiometry, +/- 1 week) i) 125-2000 Hz (frequency scan) ii) At an acoustic intensity level at or below their comfortable level through an insert earphone iii) Directly through the CI
- Approximately 12 Month Visit a) Audio Assessment i) Pure tone unaided audiometry in the implanted and the unimplanted ear ii) Bone-conduction thresholds as appropriate b) Measure ECochG responses in clinic (to coincide with audiometry, +/- 1 week) i) 125-2000 Hz frequency scan ii) At an acoustic intensity level at or below their comfortable level through an insert earphone iii) Directly through the CI Detailed description of measurements and procedure Pure tone and bone-conduction audiometry Pure tone audiometry will be performed following the conventional, routine protocol currently in place for determining CI candidacy. Where possible, pure tone thresholds will be established in the implanted ear for 125, 250, 500, 750, 1000, 1500, 2000, 3000, 4000, 6000, and 8000 Hz. Testing will be conducted using insert earphones, and where indicated, the contralateral ear will be masked. Both the implanted and the non-implanted ear will be measured. If clinically appropriate, bone-conduction testing will be performed as well following conventional practices. For young children in our cohort, for whom hearing testing can be uniquely challenging, thresholds obtained across more than one visit will be permitted and thresholds may be estimated base on auditory brainstem response (ABR) testing.
In line with the Minimum Reporting Standards for Adult Cochlear Implantation recommendations, in patients with functionally relevant pre-operative low frequency pure tone averages (125, 250, 500 Hz) < 80 dB HL, post-operative residual hearing will be reported. Each frequency will be reported individually (125, 250, 500, 1000, 1500, 2000, 4000, and 8000 Hz) rather than as a pure tone average.
Electrocochleography
In the operating room, a 500 Hz tone burst will be presented to the participant at a 110 dB SPL through an insert earphone in the external auditory canal. This acoustic stimulus will provoke movements of remaining inner and outer cochlear hair cells and evoke a response from the auditory nerve. Tone burst stimuli at 500 Hz have been shown to produce the largest amplitude ECochG response, therefore, will be used as the default stimulus here. The resulting cochlear potentials will be recorded using the recording electrode from the apical aspect of the CI electrode. By averaging the recorded signal synchronized with stimulus delivery, the responses can be reinforced while unsynchronized noise will average out. This utilization is consistent with indications covered under this FDA 510(k) clearance.
Intra-operative preparation
The insert earphone will be placed in the external ear canal after cerumen removal. The ear canal will be surgically prepared, followed by suctioning of prep fluid. Following the conventional technique, the measurement ear will be folded forward and taped. The surgery will proceed following the standard-of-care practice consisting of a cortical mastoidectomy, a facial recess (posterior tympanotomy), and preparation of intracochlear access via the round window or an extended round window approach. Before the CI electrode will be inserted, the headpiece will be connected to the implant, and the ECochG software will be triggered to begin the ECochG recordings. Figure 2 depicts a schematic of the measurement system setup. Figure 3 shows an example of the noninvasive surface electrode and earphone array. Figure 4 shows the monitor and unit through which the ECochG is observed and recorded.
To facilitate correlation of changes in ECochG potentials during CI electrode insertion and surgical events that ultimately relate to trauma within the cochlea, the surgeon will verbally indicate the progress of electrode insertion (e.g., "at the round window," "at the first marker on the electrode," "at the last marker on the electrode"), which will be recorded in the software by an assistant and synched with the ECochG signals.
Post-operative ECochG
For post-operative ECochG measurements in the clinic, the setup depicted in Figure 3 will be utilized. For this testing, the external component of the CI will be temporarily removed (equivalent to simply taking off a hearing aid) and replaced with an external head coil component (physically identical to the CI's external head coil) that allows for ECochG measurement. After connecting the head piece, a frequency scan from 125-2000 Hz will be presented to the participant at an acoustic intensity level at or below their comfortable listening level through an insert earphone in the external auditory canal. After measurements are collected, the participant's own external component will be put back in place. This measurement takes up to 5 minutes and does not require active participation of the participant.
CT Scan
A single post-operative CT scan will be conducted to identify the electrode's scalar location. A post-operative CT scan is often performed as a part of the regular clinical routine in patients for whom more information about the CI electrode location is needed. The post-operative CT will be collected per parameters outlined in Appendix 1.
Risks
The chief risks associated with this study are those inherent to CI surgery itself. The use of intraoperative ECochG has been well-demonstrated to pose no added patient risks, but may, as discussed above, provide an important benefit. Participation in this study will involve the following specific considerations:
- Increased surgical time: The ECochG measurement procedure adds up to 5-15 minutes to the procedure. During this added procedure time, the Anesthesia team will closely monitor the patient. If there are any concerns at any time, the study activity will be ceased.
- Post-operative CT scan: Associated radiation exposure. The implant, sound processor, and the clinical programming interface (CPI) hardware are all FDA-approved, and their use in the study is not associated with any additional risk to the patient. ECochG devices are FDA-cleared Class II devices. For an example of an FDA 510(k) clearance letter for the Otometrics device (k143670), please see Appendix. The ECochG recording software is not FDA/Conformité Européenne (CE) certified, but it has been thoroughly tested per AB's internal quality system. The recording software is not part of the CI operation and does not introduce any new or changed risk to the patient. It has been verified that the experimental software does not affect the performance of the FDA-approved software or hardware. Further, the entire protocol detailed above has been utilized and reported upon across several institutions validating the feasibility, ease, and safety of this modification to the convention "no feedback" approach to CI electrode insertion. This study's principal investigator (PI) also has experience using the current system.
Data Acquisition and Storage
Post-operative audiometric measurements and post-operative CT scan results will be recorded in the participant's study binder. Results of intra-operative and post-operative ECochG will be saved by the ECochG software program but will also be printed and kept in the participant's binder. All files will be archived. The main study results will be transferred to Excel-files for analysis. Further analyses will be done with Excel, Matlab or statistical software packages. A member of the Biostatistics Department will assist in statistical analysis. All results will be made anonymous prior to being shown to any third party. It will not be possible for any individual study participant to be recognized from his or her study data.
In addition, we will compare ECochG-based predictions associated with CI electrode scalar position and hearing outcomes to predications made based on conventional demographic and audiometric data. To facilitate multivariate analysis, we will extract biographical (e.g., age, etiology of hearing loss, duration of deafness) and surgical (e.g., device and electrode type) factors from the electronic medical record.
Statistical Analysis
Randomization
Block randomization is statistical strategy to prevent unequal numbers of participants from being randomized to one arm vs the other (here, audible signal "on" versus audible signal "off"). For example, using a random number generator set to individually assign 100 participants to one of two groups, there is no assurance that an equal numbers of study participants would end up in the "audible signal on" group, resulting in an unbalanced overall sample, despite randomization of each participant.
Using a block approach, the total sample is divided into smaller blocks and randomization is performed within each block with the rule that the number of allocations is balanced within that block. In our study, although each institution will likely only contribute about 40 participants, we have designed a randomization schedule to allow for 100 participants to be run for each program. This sample of 100 was divided into 50 blocks of two participants; the two participants are randomized ensuring that one goes into the "signal off" group and one goes to the "signal on" group.
Power Analysis
To ensure that our study is appropriately powered to detect a significant difference in the primary outcomes measures, we performed a power analysis with the assistance of a biostatistician. Post-operative CT-based indication of scalar position is treated as a dichotomous variable (i.e., either in the scala tympani or in the scala vestibuli); post-operative hearing outcomes are treated as a continuous variable.
Scalar Dislocation: Preliminary data indicates that the current state of CI electrode dislocation from the scala tympani to the scala vestibuli is approximately 35% (or, a "successful" scala tympani position is achieved at a rate of 65%). For participants randomized to "ECochG audible signal on," our expectation, driven by preliminary data, is to decrease the rate of scalar dislocation to approximately 15% (or, a "successful" scala tympani position rate of 85%). Setting the alpha error rate at 2.5%, a total sample size of 192 participants, or 96 participants in each of the two randomization groups, was determined using a Fischer exact test. If we permit a 5% error rate, the total sample size drops to 162 patients (81 randomized to audible signal "on"; 81 randomized to signal "off"). While these numbers of participants are higher than would be possible to achieve at our site alone in an average two-year period, through a coordinated effort to pool multi-center data, it will be easily achievable.
Secondary Planned Analysis
Electrode Type: As detailed above, once a participant is enrolled in the study, the surgeon will select which of two CI electrodes are most appropriate. A secondary analysis comparing scalar position and hearing preservation outcomes will be performed (i.e., four total between-group analyses) between the two electrode groups.
Pediatric Participants: This study will include both adult and pediatric participants. A secondary analysis comparing scalar position and hearing outcomes between adult and pediatric participants will be performed (again, four total between-group analyses).
Regression Analysis: To model the influence of "ECochG on" on the primary outcome measures in the context of participant age group and electrode choice, two regression analyses will be performed - one for the outcome measure of scalar position and one for hearing outcomes.
Hospital Effect Analysis: To determine if there is a meaningful difference in outcome measures across the different participating hospital settings, a secondary analysis will be performed as well.
Safeguarding of Protected Health Information (PHI) Upon study enrollment, participants will be assigned an alphanumeric code that will be used to track their data. A code key will be maintained by the investigators on a secure server and accessed using password-protected computers located in a locked office in a secure research space. Participant identity cannot be discovered from ECochG data. Likewise, CT images and audiometric data will not reveal participant identity and will be made fully anonymous prior to sharing with any third party. Participant study binders, labeled using their alphanumeric code only, will be stored in a locked cabinet, in a locked office, in a secure research area accessible only to the investigators.
Study design
- Primary purpose
- Other
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Double blind (participant, outcomes assessor)
- Number of arms
- 2
- Model description
- Sample of cochlear implant recipients. Half randomized for observation with ECOchG on, half randomized to ECochG off
| Arm | Type | Receives |
|---|---|---|
| Arm 1: Audible ECochG Response Off | Other | Other: ElectrocochleographyArm 1: Audible ECochG Response Off This condition is identical to the current standard-of-care for conventional CI surgery used worldwide. The surgeon will perform his or her electrode insertion without ECochG monitoring. Minute manipulations of the electrode are a normal part of conventional electrode insertion; manipulations such as redirecting the insertion vector or slowing down insertion speed will be made, as deemed necessary by the surgeon. A full electrode insertion will be performed, as appropriate. The ECochG responses will be recorded, but the surgeon will be blinded to this information during surgery. |
| Arm 2: Audible ECochG Response On | Experimental | Other: ElectrocochleographyThis condition will have the audible ECochG response on and available to the surgeon. In this condition, the surgeon perform a conventional electrode insertion while listening to the running ECochG signal for drop in amplitude (suggesting impending trauma). If no drop is detected, insertion will proceed to the full electrode length according to the standard-of-care. If an ECochG amplitude drop is observed, the surgeon will place this observation in its clinical context and evaluate insertion parameters, (i.e., insertion vector, insertion speed, etc.), customary practice with conventional CI surgery, but here supplemented by the ECochG response. In the case of an ECochG amplitude drop that does not recover, the standard-of-care practice of achieving a full electrode insertion will be followed. |
Who may qualify
- Ages
- 1 year and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Child, Adult, Older adult
Key inclusion criteria (5 listed)
- Pure-tone audiometry thresholds ≤80 dB HL at 500 Hz
- One year of age and older
- Normal candidacy requirements for cochlear implantation met
- No cochlear abnormality that might prevent full insertion of the CI electrode array
- No additional handicap that would prevent study procedures from being followed
Key exclusion criteria (5 listed)
- Chronic otitis media
- Malformed cochlea
- Auditory neuropathy spectrum disorder (ANSD)
- Presence of ear tubes
- Prior middle ear surgeries or trauma including disruption of ossicles
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| ElectrocochleographyAlso: ECochGElectrocochleography is a noninvasive method of monitoring for acoustic evoked electrophysiologic responses from the cochlea. A speaker in the external auditory canal presents a tone burst stimulus and a nearby electrode, in this case from the apical electrode of the cochlear implant, records changes in the electrical activity within the cochlea. Different functional elements within the cochlea have signature electrophysiologic responses that can be isolated and studied individually. Through the use of intracochlear electrocochleography during cochlear implant electrode insertion valuable insight can be gained about structural or physiological changes that may be occurring. | Other | Arm 1: Audible ECochG Response Off, Arm 2: Audible ECochG Response On |
Primary outcome
The CI electrode's scalar position as indicated by post-operative computed tomography (CT)
Time frame: To be performed within one month of cochlear implantation
Following cochlear implant surgery a CT scan, optimized for resolution of the CI electrode, will be obtained. This will be merged with routine clinically acquired pre-operative imaging to determine which of the scala the electrode sides in and whether or not there has been any translocation from one scala into another.
1 secondary outcome
Post-operative hearing performance
Time frame: To be collected at post-op clinical visits until 12 months post-op
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 14 Jan 2026.
- Background: PubMed 1577630Lehnhardt E. [Placement of intracochlear electrodes with Healon]. HNO. 1992 Mar;40(3):86-9. German.
- Background: PubMed 7668741Rogowski M, Reiss G, Lehnhardt E. Morphologic study of the guinea pig cochlea after cochlear implantation using the "soft surgery" technique. Ann Otol Rhinol Laryngol Suppl. 1995 Sep;166:434-6.
- Background: PubMed 10890124Gstoettner W, Hamzavi J, Franz P, Plenk H Jr, Czerny C, Susani M, Adunka O, Baumgartner WD. [Intracochlear position of cochlear implant electrodes]. Wien Klin Wochenschr. 2000 Jun 2;112(11):477-80. German.
- Background: PubMed 19390172Lenarz T, Stover T, Buechner A, Lesinski-Schiedat A, Patrick J, Pesch J. Hearing conservation surgery using the Hybrid-L electrode. Results from the first clinical trial at the Medical University of Hannover. Audiol Neurootol. 2009;14 Suppl 1:22-31. doi: 10.1159/000206492. Epub 2009 Apr 22.
- Background: PubMed 23539259Incerti PV, Ching TY, Cowan R. A systematic review of electric-acoustic stimulation: device fitting ranges, outcomes, and clinical fitting practices. Trends Amplif. 2013 Mar;17(1):3-26. doi: 10.1177/1084713813480857.
- Background: PubMed 23992489Lenarz T, James C, Cuda D, Fitzgerald O'Connor A, Frachet B, Frijns JH, Klenzner T, Laszig R, Manrique M, Marx M, Merkus P, Mylanus EA, Offeciers E, Pesch J, Ramos-Macias A, Robier A, Sterkers O, Uziel A. European multi-centre study of the Nucleus Hybrid L24 cochlear implant. Int J Audiol. 2013 Dec;52(12):838-48. doi: 10.3109/14992027.2013.802032. Epub 2013 Sep 2.
- Background: PubMed 17496653Aschendorff A, Kromeier J, Klenzner T, Laszig R. Quality control after insertion of the nucleus contour and contour advance electrode in adults. Ear Hear. 2007 Apr;28(2 Suppl):75S-79S. doi: 10.1097/AUD.0b013e318031542e.
- Background: PubMed 18667935Finley CC, Holden TA, Holden LK, Whiting BR, Chole RA, Neely GJ, Hullar TE, Skinner MW. Role of electrode placement as a contributor to variability in cochlear implant outcomes. Otol Neurotol. 2008 Oct;29(7):920-8. doi: 10.1097/MAO.0b013e318184f492.
- Background: PubMed 22291043Mandala M, Colletti L, Tonoli G, Colletti V. Electrocochleography during cochlear implantation for hearing preservation. Otolaryngol Head Neck Surg. 2012 May;146(5):774-81. doi: 10.1177/0194599811435895. Epub 2012 Jan 30.
- Background: PubMed 28174524Eggermont JJ. Ups and Downs in 75 Years of Electrocochleography. Front Syst Neurosci. 2017 Jan 24;11:2. doi: 10.3389/fnsys.2017.00002. eCollection 2017.
- Background: PubMed 27879487Koka K, Saoji AA, Litvak LM. Electrocochleography in Cochlear Implant Recipients With Residual Hearing: Comparison With Audiometric Thresholds. Ear Hear. 2017 May/Jun;38(3):e161-e167. doi: 10.1097/AUD.0000000000000385.
- Background: PubMed 29557283Adunka OF, Gantz BJ, Dunn C, Gurgel RK, Buchman CA. Minimum Reporting Standards for Adult Cochlear Implantation. Otolaryngol Head Neck Surg. 2018 Aug;159(2):215-219. doi: 10.1177/0194599818764329. Epub 2018 Mar 20.
Related trials for Hearing Loss
Not yet recruiting
Automated Text Message Reminders to Promote Hearing Aid Adoption
Hearing Loss
Enrolling by invitationObservational study
Post-Market Registry Study for Vibrant Hearing Solutions
Conductive Hearing Loss, Mixed Hearing Loss
Recruiting
Investigating Auditory Processing in the Users of Auditory Brainstem and Cochlear Implants
Deafness
RecruitingObservational study
Collection of Clinical Data and Specimens for Research in Hearing, Balance, Taste, Smell, Voice, Speech, and Language Disorders.
Hearing Loss, Deafness
RecruitingObservational study
Rare Disease Patient Registry & Natural History Study - Coordination of Rare Diseases at Sanford
Rare Disorders, Undiagnosed Disorders
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Electrocochleography in people with Hearing Loss and Cochlear Implant, run by Medical College of Wisconsin at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 5 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 14 Jan 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
The CI electrode's scalar position as indicated by post-operative computed tomography (CT) (time frame: To be performed within one month of cochlear implantation). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT03685461, which also lists 13 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 14 Jan 2026.