AzTrials
AzTrials

Emergency MedicineNCT03733158

Flexible Tip Bougie Catheter Intubation

A study testing the standard Bougie stylet for difficult intubation and The new Flexible Tip Bougie catheter in people with Emergency Medicine and Endotracheal Intubation, run by Lazarski University at 1 site in Poland.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

We, therefore conducted a randomized cross over study to evaluate the usefulness of this new device use by experienced anesthesiologists in several airway manikin scenarios. We hypothesized that in the hands of experienced anesthesiologists the new Flexible Tip Bougie catheter would perform comparably to the standard… Read more about this study

Who is it for?
Ages 18 years and olderHealthy volunteers can take part
What is being tested?
the standard Bougie stylet for difficult intubation and The new Flexible Tip Bougie catheter
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
32 participants
Where
1 sitePoland
Study dates
1 Mar 2019to 30 May 2019
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • physicians
  • give voluntary consent to participate in the study
  • none experience in videolaryngoscopy
  • less than 1 year experience in medicine

Who cannot join

  • not meet the above criteria
  • wrist or low back diseases

Trial locations and contacts

1 site in 1 country.

Poland1 site
  • Lazarski University

    Warsaw, Masovia, 02-662

Other trials in Poland

About this study

Official title: Comparison of the New Flexible Tip Bougie Catheter and Standard Bougie Stylet for Tracheal Intubation by Anesthesiologists in Different Difficult Airway Scenarios: a Randomized Crossover Trial

We, therefore conducted a randomized cross over study to evaluate the usefulness of this new device use by experienced anesthesiologists in several airway manikin scenarios. We hypothesized that in the hands of experienced anesthesiologists the new Flexible Tip Bougie catheter would perform comparably to the standard bougie catheter) in the normal airway scenario. In the difficult airway (both tongue edema, manual in-line stabilization, or cervical collar stabilization), we hypothesized that the new Flexible Tip Bougie catheter would prove superior to the standard Bougie stylet.

Being tested
the standard Bougie stylet for difficult intubation, The new Flexible Tip Bougie catheter
Keywords
endotracheal intubation, emergency medicine, cardiopulmonary resuscitation, physician
Medical subject headings
Heart Arrest

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • the standard Bougie stylet for difficult intubationDevice

    intubation with the standard Bougie stylet for difficult intubation and endotracheal tube 7.0 internal diameter

  • The new Flexible Tip Bougie catheterDevice

    intubation with The new Flexible Tip Bougie catheter and endotracheal tube 7.0 internal diameter

Study groups in NCT03733158
Study groupRoleWhat they receive
Normal airwayExperimentalintubation in normal aurway condition
Receives: Device: the standard Bougie stylet for difficult intubation; Device: The new Flexible Tip Bougie catheter
Tongue edemaExperimentalintubation in Tongue edema condition
Receives: Device: the standard Bougie stylet for difficult intubation; Device: The new Flexible Tip Bougie catheter
Pharyngeal obstructionExperimentalintubation in Tongue edema condition
Receives: Device: the standard Bougie stylet for difficult intubation; Device: The new Flexible Tip Bougie catheter
Manual cervical inline stabilizationExperimentalintubation in Manual cervical inline stabilization condition
Receives: Device: the standard Bougie stylet for difficult intubation; Device: The new Flexible Tip Bougie catheter
Cervical collar stabilizationExperimentalintubation in Cervical collar stabilization condition
Receives: Device: the standard Bougie stylet for difficult intubation; Device: The new Flexible Tip Bougie catheter
Cervical collar stabilization and pharyngeal obstructionExperimentalintubation in Cervical collar stabilization and pharyngeal obstruction condition
Receives: Device: the standard Bougie stylet for difficult intubation; Device: The new Flexible Tip Bougie catheter

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. time to intubation

    time from pick up device to the final placement tube in trachea

    Measured: 1 day

Secondary outcomes (4)
  1. success of intubation

    A failed intubation attempt was defined as an attempt in which the trachea was not intubated, or which required more than 120 seconds to perform

    Measured: 1 day

  2. Number of optimalization maneuvers

    the number of optimization maneuvers required (re-adjustment of head position, second assistant) to aid endotracheal intubation.

    Measured: 1 day

  3. Ease of use

    self-reported percentage the vocal cord visualization. A 100% score is a extremely difficult procedure. A Ease of use score of 1% means that procedure is extremely easy

    Measured: 1 day

  4. Dental compression

    An independent observer scored the severity of dental compressions, which was calculated based on the number of audible teeth clicks (0; 1; ≥2) with the Laerdal airway trainer, and based on a grading of pressure of the teeth (none = 0; mild = 1; moderate/serve ≥2) on the Simman®3G simulator. At the end of each scenario, each participant scored the ease of use of each intubation method on a visual analogue scale (VAS; from 0=Extremely Easy to 100=Extremely Difficult).

    Measured: 1 day

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted7 Nov 2018
  2. Study start1 Mar 2019
  3. Primary completion30 May 2019
  4. Study completion30 May 2019

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Crossover
Masking
Single blind
Who is masked
Outcomes assessor
Enrolment
32 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03733158
Sponsor's protocol ID
INT_2018_UL
Status last verified
Jun 2019
First submitted
5 Nov 2018
Last updated
19 Jun 2019
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided: data will be available from the main investigator

Publications

  • Ruetzler K, Smereka J, Abelairas-Gomez C, Frass M, Dabrowski M, Bialka S, Misiolek H, Plusa T, Robak O, Aniolek O, Ladny JR, Gorczyca D, Ahuja S, Szarpak L. Comparison of the new flexible tip bougie catheter and standard bougie stylet for tracheal intubation by anesthesiologists in different difficult airway scenarios: a randomized crossover trial. BMC Anesthesiol. 2020 Apr 20;20(1):90. doi: 10.1186/s12871-020-01009-7.

    PubMed 32312225

Questions about this trial

What is this clinical trial studying?

A study testing the standard Bougie stylet for difficult intubation and The new Flexible Tip Bougie catheter in people with Emergency Medicine and Endotracheal Intubation, run by Lazarski University at 1 site in Poland.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 19 Jun 2019. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Poland. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

time to intubation (time frame: 1 day). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT03733158, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.