RadiationCOMpLExNCT03735706

Relationship Between Contrast Media Volume and Tube Voltage in CT for Optimal Liver Enhancement, Based on Body Weight.

A study testing Radiation dose reduction, Contrast media volume reduction and Unenhanced slice in people with Radiation and Contrast Media, run by Maastricht University Medical Center at 1 site in Netherlands.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Computed Tomography (CT) is widely used in abdominal imaging for a variety of indications. Contrast media (CM) is used to enhance vascular structures and organ parenchyma. Attenuation of the liver makes it possible to recognize hypo- and hypervascular lesions, which are often invisible on unenhanced CT images. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Radiation, Contrast Media, Liver
What is being tested?
Radiation dose reduction, Contrast media volume reduction and Unenhanced slice
Could I receive a placebo?
No, everyone receives an active treatment
How many people
245 participants
Where
1 siteNetherlands
Study dates
13 Dec 2018to 26 Jun 2019
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patients referred for abdominal CT in portal venous phase
  • Patients ≥ 18 years and competent to sign an informed consent

Who cannot join

  • Hemodynamic instability
  • Pregnancy
  • Renal insufficiency (defined as Glomerular Filtration Rate (GFR) < 30 mL/min/1,73m2 [Odin protocol 004720])
  • Iodine allergy (Odin protocol 022199)
  • Age <18 years
  • Absence of informed consent

Trial locations and contacts

1 site in 1 country.

Netherlands1 site
  • MUMC+

    Maastricht, Limburg, 6224 CG

Other trials in Netherlands

About this study

Official title: The Relationship Between COntrast Media Volume and Tube voLtage in Computed Tomography of the Liver, for Optimal Enhancement Based on Total Body Weight: A Randomized Controlled Trial. [COMpLEx Trial]

Computed Tomography (CT) is widely used in abdominal imaging for a variety of indications. Contrast media (CM) is used to enhance vascular structures and organ parenchyma. Attenuation of the liver makes it possible to recognize hypo- and hypervascular lesions, which are often invisible on unenhanced CT images. Lesions can only be detected in case they are large enough and the contrast with the background is high enough. Heiken et al. showed already in 1995 that a difference in Hounsfield Units (HU) of at least 50 HU is needed to be able to recognize liver lesions [1]. On the other hand, patients should not receive more CM than necessarily, because of possible underlying physiological effects [2-4]. Although there has been some controversy about this recently, there is no need to give patients more CM than needed, because of increased costs, no quality improvement and their might still be a relationship with contrast induced nephropathy (CIN) [5].

Recent publications suggested individualization of injection protocols that can be based on either total body weight (TBW) or lean body weight (LBW) [6-9]. In the investigators department an injection protocol based on TBW is currently used.

Besides the CM injection parameters, scanner parameters are of influence on the attenuation as well. Because of recent technical developments it became possible to reach a good image quality (IQ) at lower tube voltages [10]. When the x-ray output comes closer to the 33 keV k-edge of Iodine, attenuation increases. In short, decreasing the tube voltage increases the attenuation of iodine. Scanning at a lower tube voltage therefore gives rise to even lower CM volumes. Lastly, it would be revolutionary to accomplish a liver enhancement that is homogenous, sufficient for lesion detection and comparable between patients and in the same patients, regardless of weight and scanner settings used.

Read the detailed description

Computed Tomography (CT) is a non-invasive imaging tool, used for a great variety of indications. Contrast media (CM) is used to enhance vascular structures and organ parenchyma. The visibility of liver lesions depends mainly on the ratio between the size and the difference of the lesion to the background. A large lesion might be visible without administration of CM, whilst a smaller lesion needs the addition of CM to become visible. Additionally, CM can be useful in the characterization of liver lesions. Heiken et al. (1995) found that an attenuation of the parenchyma after CM administration of at least ∆ 50 Hounsfield units (HU) compared to an unenhanced scan (in the same patient) is necessary to recognize liver lesions. This study proposed a dosing factor of 0.521 g I/kg to be necessary to reach such attenuation at a tube voltage of 120 kV [1].

The parenchymal enhancement depends on patient, CT scanner and CM factors. Weight, height, cardiac output, age, gender, venous access, breath-holding, renal function and comorbidity all fall under patient factors [8]. Recently much research showed preferable outcomes for individualized CM injection protocols, in which the contrast bolus is adapted to patient TBW, LBW or body surface area (BSA) [6, 7, 9, 13-15]. In a recent feasibility study in the department of the investigators, the attenuation of the liver parenchyma was evaluated. Results showed that a body weight adapted CM injection protocol resulted in more homogeneous liver enhancement compared to a fixed CM dose (not published yet).

With recent technological developments in X-ray tube technology it became possible to use lower tube voltages. As a result making it possible to perform scans with a sufficient image quality (IQ) and a low tube voltage and therefore a lower radiation dose [10]. Another advantage lies in the fact that reducing the tube voltage, approaching 33 keV k-edge of iodine, results in an increase in attenuation of the iodine. The new technological developments make it possible to reduce the radiation dose and CM volume at the same time. So reducing the tube voltage, makes it also possible to reduce the CM volume.

As recommended by the supplier, it is possible to calculate the total iodine load (TIL) that can be spared with the use of lower kV settings [16]. A reduction of 10 kV should result in a 10% reduction in CM volume. Reducing the tube voltage from 120 to 90 kV should therefore lead to a 30% reduction in CM volume. As mentioned before it is preferred to use an individualized CM injection protocol based on TBW or LBW. For this study, this theory is adapted to the concept of TBW. The following indicates which dosing factors should be used for each kV setting, based on the recommendations mentioned in the above.

120 kV -> 0.521 g I/kg 110 kV -> 0.469 g I/kg 100 kV -> 0.417 g I/kg 90 kV -> 0.365 g I/kg 80 kV -> 0.313 g I/kg 70 kV -> 0.261 g I/kg

The aim of present study is to investigate if adapting the dosing factor based on TBW and therefore the CM volume to the tube voltage used, results in a more homogeneous liver enhancement. The hypothesis is to find a more homogeneous enhancement between patients and in the same patient, regardless of body composition and tube voltage used.

Being tested
Radiation dose reduction, Contrast media volume reduction, Unenhanced slice, Weight
Keywords
Radiation, Contrast media, Liver, Body Weight
Medical subject headings
Body Weight

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Radiation dose reductionRadiation

    The radiation dose is is different between groups

  • Contrast media volume reductionOther

    Contrast media volume is different between groups

  • Unenhanced sliceRadiation

    One unenhanced slice at the level of the portal vein will be added to the protocol before administration of contrast media. It will only take a minute to perform this extra slice. The patient does not have to visit the department a second time and no (extra) contrast is needed for this slice.

  • WeightDiagnostic test

    A weighing scale is used to measure a patients body weight right before the scan.

Study groups in NCT03735706
Study groupRoleWhat they receive
Control group - 120 kV - 0.521 g I/kgActive comparatorWeight is measured prior to the scan. Before performing the contrast enhanced CT scan(s), an unenhanced slice through the liver, at the level of the portal vein, is performed. Contrast media injection protocol with a standard dosing factor of 0.521 g I/kg of TBW and a tube voltage of 120 kV. The intervention is the application of a standard contrast media volume and a standard tube voltage of 120 kV.
Receives: Radiation: Unenhanced slice; Diagnostic Test: Weight
90 kV - 0.521 g I/kgExperimentalWeight is measured prior to the scan. Before performing the contrast enhanced CT scan(s), an unenhanced slice through the liver, at the level of the portal vein, is performed. Contrast media injection protocol with a standard dosing factor of 0.521 g I/kg of TBW. A radiation dose reduction from 120 to 90 kV. The intervention is a change in tube voltage to 90 kV, compared to group 1. The other intervention; contrast media volume, is unchanged compared to group 1.
Receives: Radiation: Radiation dose reduction; Radiation: Unenhanced slice; Diagnostic Test: Weight
100 kV - 0.417 g I/kgExperimentalWeight is measured prior to the scan. Before performing the contrast enhanced CT scan(s), an unenhanced slice through the liver, at the level of the portal vein, is performed. Contrast media volume reduction with a dosing factor of 0.417 g I/kg of TBW. A radiation dose reduction from 120 to 100 kV compared to group 1. The intervention is a change in tube voltage to 100 kV, compared to group 1. The other intervention is a change in contrast media volume, which is adapted to the tube voltage used and therefore lowered to 0.417 g I/kg.
Receives: Radiation: Radiation dose reduction; Other: Contrast media volume reduction; Radiation: Unenhanced slice; Diagnostic Test: Weight
90 kV - 0.365 g I/kgExperimentalWeight is measured prior to the scan. Before performing the contrast enhanced CT scan(s), an unenhanced slice through the liver, at the level of the portal vein, is performed. Contrast media volume reduction with a dosing factor of 0.365 g I/kg of TBW. A radiation dose reduction from 120 to 90 kV compared to group 1. The intervention is a change in tube voltage to 90 kV, compared to group 1. The other intervention is a change in contrast media volume, which is adapted to the tube voltage used and therefore lowered to 0.365 g I/kg.
Receives: Radiation: Radiation dose reduction; Other: Contrast media volume reduction; Radiation: Unenhanced slice; Diagnostic Test: Weight

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. A liver attenuation (Δ HU)

    The attenuation of the liver parenchyma as assessed by measuring the Hounsfield units (HU) of the liver parenchyma in an unenhanced CT scan and a scan in portal venous phase. The difference between the enhanced and unenhanced CT scan is the Δ HU. It is expected that scans in all groups have a Δ HU of at least 50 HU, which is considered sufficient. Therefore it is a non-inferiority outcome.

    Measured: Measurement for each scan is performed withing 1 month after the scan.

Secondary outcomes (14)
  1. Objective image quality - signal-to-noise and contrast-to-noise ratio

    The objective image quality parameters consist of signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). SNR is calculated by dividing the attenuation of the liver parenchyma by the corresponding standard deviation (SD) of the attenuation. The attenuation of the left erector spinae muscle is measured at the level of the liver to calculate CNR using the following established formula: liver segment attenuation minus intramuscular attenuation, divided by the SD of the intramuscular attenuation. For both a higher number indicated a better image quality. The outcome should not be significantly different between groups.

    Measured: Measurement for each scan is performed within 1 month after the scan.

  2. Subjective image quality - assessed with a 5-point Likert scale

    Two experienced radiologists will assess the subjective image quality in consensus, while being blinded for the protocol used. A 5-point Likert scale is used, in which 1= excellent; 2= good; 3 = moderate; 4 = poor; 5 = very poor. So a higher number is a worse outcome. The scale does not have a particular name.

    Measured: Measurement for each scan is performed within 1 month after the scan.

  3. Radiation dose

    The mean effective mAs (± SD), mean CTDIvol (mGy) (± SD) and the Mean DLP (mGy*cm) (± SD) are visible on screen and reported, to compare the difference in radiation dose between groups. A higher number means a higher radiation dose and is therefore a worse outcome.

    Measured: Measurement for each scan is performed within 1 month after the scan.

  4. Weight

    Patients weight (in kg) is assessed by using a weighting scale

    Measured: Directly prior to the scan it is measured and data is collected within one month after the scan.

  5. Height (in m)

    Patients height is asked

    Measured: Directly prior to the scan it is measured and data is collected within one month after the scan.

  6. Contrast media volume

    A dedicated data acquisition program (Certega Informatics Solution; Bayer) continuously monitors and collects all injection parameters (eg, total amount of CM [milliliter] and peak flow rate [milliliter per seconds]). A higher number means a higher radiation dose and is therefore a worse outcome. And results are compared between groups.

    Measured: Data is retrieved from the system within 1 month after the scan.

  7. Needle size

    A dedicated data acquisition program (Certega Informatics Solution; Bayer) continuously monitors and collects all injection parameters, among which needle size is one of the parameters. A smaller gauge of the needle could possibly mean that the desired flow rate is not possible. In general it is expected that the needle size used is not significantly different between groups.

    Measured: Data is retrieved from the system within 1 month after the scan. It is finished when all patients are scanned.

  8. Needle placement

    A dedicated data acquisition program (Certega Informatics Solution; Bayer) continuously monitors and collects all injection parameters, among which needle placement is one of the parameters. In general it is expected that the needle placement is not significantly different between groups.

    Measured: Data is retrieved from the system within 1 month after the scan.

  9. BMI

    Weight and height will be combined to report BMI in kg/m^2

    Measured: Calculated after the scan, within 1 month after the scan.

  10. Sex

    Is collected

    Measured: Collected before the scan by the technician and retrieved from the system within 1 month after the scan.

  11. Age

    Is collected

    Measured: Collected before the scan by the technician and retrieved from the system within 1 month after the scan.

  12. Scan indication

    Is collected

    Measured: Collected before the scan by the technician and retrieved from the system within 1 month after the scan.

  13. Flow rate

    A dedicated data acquisition program (Certega Informatics Solution; Bayer) continuously monitors and collects peak flow rate [milliliter per seconds]).

    Measured: Data is retrieved from the system within 1 month after the scan.

  14. Concentration of the contrast media

    All patients receive the identical contrast media concentration as used in daily clinical routine; 300 mg/ml

    Measured: Data is retrieved from the system within 1 month after the scan.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted8 Nov 2018
  2. Study start13 Dec 2018
  3. Primary completion26 Jun 2019
  4. Study completion26 Jun 2019

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Randomised
Intervention model
Parallel groups
Model description
randomized controlled trial with 4 study arms.
Masking
Triple blind
Who is masked
Participant, Care provider, Investigator
Enrolment
245 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03735706
Sponsor's protocol ID
NL66971.068.18
Acronym
COMpLEx
Status last verified
Feb 2020
First submitted
31 Oct 2018
Last updated
10 Feb 2020
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided: It is not yet known if there will be a plan to make IPD available.

Questions about this trial

What is this clinical trial studying?

A study testing Radiation dose reduction, Contrast media volume reduction and Unenhanced slice in people with Radiation and Contrast Media, run by Maastricht University Medical Center at 1 site in Netherlands.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 2 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 10 Feb 2020. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Netherlands. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

A liver attenuation (Δ HU) (time frame: Measurement for each scan is performed withing 1 month after the scan.). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 10 Feb 2020.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in