Bile Duct StrictureNCT03788655

Metal Stents (Moving Cell Stent) for Inoperable Tumors of the Bile Duct Tract

An observational study of Bile Duct Stricture and Bile Duct Cancer, run by Johannes Vermehren at 1 site in Germany.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

In this feasibility study (non-randomized), the applicability of a new "moving cell" biliary stents (by HILZO) in Klatskin tumors (bile duct obstruction) will be investigated. The HILZO Moving-Cell Stent to be examined here is a non-coated metal stent with a novelty. Read more about this study

Who is it for?
Ages 18 to 100 years
Conditions the study is for
Bile Duct Stricture, Bile Duct Cancer
How many people
30 participants
Where
1 siteGermany
Study dates
31 Dec 2018to Jun 2021
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 100 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Study population: Patients with the indication for palliative stenting of the bile duct system due to non-operable Klatskin tumors type II-IV

Who may be able to join

  • Indication for the palliative metal-stent system for malignant stenosis due to biliary cancer (Klatskin tumor).

Who cannot join

  • Age under 18 years
  • Pregnancy
  • Contraindication to an endoscopic examination
  • Life expectancy under 3 months

Trial locations and contacts

1 site in 1 country.

Mireen Friedrich-Rust, Prof. contact

069-6301-0

mireen.friedrich-rust@kgu.de

Fabian Finkelmeier, Dr. contact

069-6301-0

fabian.finkelmeier@kgu.de

Germany1 site, 1 recruiting
  • Klinikum der J. W. Goethe-Universität

    Frankfurt am Main, 60590

    Mireen Friedrich-Rust, Prof., Mireen.Friedrich-Rust@kgu.de

    Recruiting

Other trials in Germany

About this study

Official title: Feasibility Study on Novel Metal Stents (Moving Cell Stent) for Inoperable Tumors of the Bile Duct Tract

In this feasibility study (non-randomized), the applicability of a new "moving cell" biliary stents (by HILZO) in Klatskin tumors (bile duct obstruction) will be investigated.

The HILZO Moving-Cell Stent to be examined here is a non-coated metal stent with a novelty. The meshes have a diameter of 4 mm, which is rather small compared to most other stents. This significantly increases the radial force and thus the stability of the stent. Furthermore, ingrowth by tumors in the stent is difficult. The special feature is that the individual meshes can easily be stretched to 10 mm without changing the stability of the stent. This allows a second stent to pass through the first to another segment of liver.

Read the detailed description

ERCP (endoscopic retrograde cholangiopancreatography) is the standard method of treating diseases in the biliopancreatic system and the treatment goal is achieved in a very high proportion of the studies. The ERCP is based on the indirect imaging of the bile ducts by injection of contrast medium, which is visualized in X-ray fluoroscopy. Furthermore, the probing of the bile ducts by means of wire and direct interventions within the bile duct system is possible.

Malignant biliary strictures are caused by various, usually cholangiocellular or pancreatic tumors, whose surgical therapy is complex and often impossible due to advanced disease. Tumors of the papillae, lymphomas and lymph node metastases can also lead to stenosis of the extra hepatic bile ducts.

The outcome of patients with malignant biliary strictures is poor, most are already presenting with advanced disease because early symptoms are rare. In particular, the above-mentioned cholangiocellular carcinomas and pancreatic carcinomas are often resectable only in its early form with high recurrence rates. Furthermore, then only palliative concepts are possible. Various studies have shown that stenting of the biliary tract with drainage of more than 50% of the liver volume improves survival. Metal stents seem to be superior to plastic stents at a slightly higher cholangitis rate. It is therefore considered standard therapy to palliatively treat these patients with more than 3 months of life expectancy using a metal stent.

Two types of stents are currently in use, plastic stents and self-expanding metal stents (SEMS). These in turn are coated (cSEMS) and uncoated (uSEMS). In distal malignant stenosis, both cSEMS and uSEMS can be used, with a higher patency rate for cSEMS and a longer duration of uSEMS retention. The disadvantage of the uSEMS is the tumor ingrowth in the stents and the possibility of re-stenosis. Various studies have shown that metal stents are associated with better bile duct drainage and better retention time compared to plastic stents and have fewer early complications, however, a consensus regarding a survival advantage with metal stents has not yet been substantiated, with the data showing a positive trend. Since metal stents, unlike plastic stents, do not need to be changed, a significant advantage for the patient is the significant reduction in endoscopic examinations and associated hospitalization and complication rates.

The HILZO Moving-Cell Stent to be examined here is a non-coated metal stent with a novelty. The meshes have a diameter of 4 mm, which is rather small compared to most other stents. This significantly increases the radial force and thus the stability of the stent. Furthermore, ingrowth by tumors in the stent is difficult. The special feature is that the individual meshes can easily be stretched to 10 mm without changing the stability of the stent. This allows a second stent to pass through the first to another segment of liver. Previous metal stents could previously only be placed side by side in the common bile duct, thereby limiting the number of stents as a function of the gait and the stents can develop worse in the main course.

Keywords
metal stent, biliary stricture, stenting
Medical subject headings
Bile Duct Neoplasms

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Technical feasibility of intrahepatic stenting

    Successful biliary drainage by new stent

    Measured: 12 month

Secondary outcomes (5)
  1. Number of drained segments

    Number of successful drained liver segments

    Measured: 12

  2. Length of intervention

    Length of the endoscopy with the new stent

    Measured: 12 month

  3. Stent dysfunction

    Stent migration or stenosis

    Measured: 12 month

  4. Number of necessary endoscopies per year

    Number of necessary endoscopies per year to have successful drainage

    Measured: 12 month

  5. Survival rate

    Survival of patients 12 month after the procedure

    Measured: 12 month

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted27 Dec 2018
  2. Study start31 Dec 2018 (estimated)
  3. Primary completionDec 2020 (estimated)
  4. Study completionJun 2021 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
30 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT03788655
Sponsor's protocol ID
JWGUHMED1-010
Status last verified
Dec 2018
First submitted
25 Dec 2018
Last updated
27 Dec 2018
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

An observational study of Bile Duct Stricture and Bile Duct Cancer, run by Johannes Vermehren at 1 site in Germany.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 27 Dec 2018. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Germany. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Mireen Friedrich-Rust, Prof. (069-6301-0, mireen.friedrich-rust@kgu.de), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Technical feasibility of intrahepatic stenting (time frame: 12 month). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 27 Dec 2018.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in