Trial summary
Newborns in the neonatal intensive care unit (NICU) are at high risk for wrong-patient errors. Effective 2019, The Joint Commission requires that health systems adopt distinct methods of newborn identification as part of its National Patient Safety Goals. Read more about this study
- Who is it for?
- Any age
- Conditions the study is for
- Medical Errors, Electronic Medical Records
- What is being tested?
- Pictograph in Banner and Verification Alert
- Type of treatment
- Lifestyle or therapy programme
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 6,250 participants
- Where
- 4 sitesUnited States
- Study dates
- 16 Mar 2022to 30 Jun 2028
- Phase
- Interventional
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages Any age
- All sexes
- No healthy volunteers
- Child, Adult, Older adult
Who may be able to join
- All infants receiving care in the study NICUs for whom an order was placed during the study period.
- All clinicians with the authority to place electronic orders in the NICU and who placed electronic orders during the study period.
Who cannot join
- None
Trial locations and contacts
4 sites in 1 country. Contact the study team or a site near you to ask about taking part.
United States4 sites, 2 recruiting
- Not yet recruiting
Johns Hopkins Medicine
Baltimore, Maryland, 21287
Allen Chen, MD, PhD
- Completed
Brigham and Women's Hospital
Boston, Massachusetts, 02115
- Recruiting
New York-Presbyterian Hospital
New York, New York, 10032
Jason S Adelman, MD,MS
- Active, not recruiting
Montefiore Medical Center
The Bronx, New York, 10461
About this study
Official title: Assessing the Effectiveness of Pictographs for Preventing Wrong-Patient Errors in Neonatal Intensive Care Units: A Randomized Controlled Trial
Newborns in the neonatal intensive care unit (NICU) are at high risk for wrong-patient errors. Effective 2019, The Joint Commission requires that health systems adopt distinct methods of newborn identification as part of its National Patient Safety Goals. Displaying patient photographs in the electronic health record (EHR) is a promising strategy to improve identification of children and adults, but is unlikely to be effective for identifying newborns. This study assesses the use of Pictographs as a "photo equivalent" for improving identification of newborns in the NICU.
This multi-site, two-arm, parallel group, cluster randomized controlled trial will test the effectiveness of Pictographs for preventing wrong-patient order errors in the NICU. Pictographs consist of three elements: 1) pictorial symbols of easy-to-remember objects (e.g., rainbow, lion); 2) the infant's given name (when available); and 3) a color-coded border indicating the infant's sex. The study will be conducted at three academic medical centers that utilize Epic EHR. All parents or guardians will be asked to select a unique Pictograph for each infant admitted to the NICU to be displayed on the isolette and in the EHR for the duration of the infant's hospital stay. All clinicians with the authority to place electronic orders in the study NICUs will be randomly assigned to either the intervention arm (Pictographs displayed in the EHR) or the control arm (no Pictographs displayed in the EHR). The main hypothesis is that clinicians assigned to view Pictographs in the EHR will have a significantly lower rate of wrong-patient order errors in the NICU versus clinicians assigned to no Pictographs.
The primary outcome is wrong-patient order sessions, defined as a series of orders placed for a single patient by a single clinician that contains at least one wrong-patient order. The Wrong-Patient Retract-and-Reorder (RAR) measure, a validated, reliable, and automated method for identifying wrong-patient orders, will be used as the primary outcome measure. The Wrong-Patient RAR measure identifies one or more orders placed for a patient that are retracted within 10 minutes, and then reordered by the same clinician for a different patient within the next 10 minutes. In the validation study conducted at a large academic medical center, real-time telephone interviews with clinicians confirmed that 76.2% of RAR events were correctly identified by the measure as wrong-patient orders.
Read the detailed description
BACKGROUND
Newborns in the neonatal intensive care unit (NICU) are at high risk for wrong-patient errors. Effective 2019, The Joint Commission requires that health systems adopt distinct methods of newborn identification to prevent this type of error as part of its National Patient Safety Goals. Displaying patient photographs in the electronic health record (EHR) is a promising strategy to improve identification of children and adults, but photographs are not likely to be effective for identifying newborns. Therefore, this study assesses the use of Pictographs as a "photo equivalent" for improving identification of newborns in the NICU.
METHODS
The primary hypothesis of this study is that clinicians randomly assigned to view Pictographs in the EHR (intervention arm) will have a significantly lower rate of wrong-patient order errors in the neonatal intensive care unit (NICU) compared to clinicians assigned to view no Pictographs in the EHR (control arm). The secondary hypothesis is that the rate of wrong-patient orders for siblings of multiple births in the NICU will be significantly lower for clinicians randomized to the intervention versus control arm.
The study will pursue the following specific aims:
Aim 1: Test the effectiveness of displaying Pictographs in EHR systems for reducing wrong-patient orders among infants in the NICU, using the Wrong-Patient Retract-and-Reorder measure to identify the outcome.
Aim 2: Conduct subgroup analyses of the effectiveness of Pictographs for reducing the rates of wrong-patient orders among siblings of multiple-birth infants in the NICU.
Design. This multi-site, two-arm, parallel-group, cluster randomized controlled trial will test the effectiveness of Pictographs for preventing wrong-patient order errors in the NICUs of three health systems. Pictographs consist of three elements: 1) pictorial symbols of easy-to-remember objects (e.g., rainbow, lion); 2) the infant's given name (when available); and 3) a color-coded border indicating the infant's sex. For each infant admitted to the study NICUs, parents or guardians will be asked to select a unique Pictograph to be displayed on the isolette and in the EHR for the duration of each infant's hospital stay. Clinicians randomized to the intervention arm will see a Pictograph displayed in the banner and verification alert in the EHR. Clinicians randomized to the control arm will not see Pictographs in the EHR.
Study Sites. The study includes NICUs at the following participating study institutions representing diverse patient populations: NewYork-Presbyterian Hospital, New York, NY; Montefiore Medical Center, Bronx, NY; and Johns Hopkins Medicine, Baltimore, MD. All sites will conduct the study in EpicCare (Epic Systems Corporation, Verona, WI).
Patient Inclusion Criteria. All infants admitted to the study NICUs will be eligible to be included.
Clinician Inclusion Criteria. All clinicians who place electronic orders in the NICU at the study sites during the study period will be included.
Randomization. The clinician is the unit of randomization. Each ordering clinician will be randomly assigned to a study arm in a 1:1 random allocation scheme using a computer random number generator program at all study sites. Then, clinicians will be assigned, as randomized, to groupers built into Epic to apply configuration rules that dictate whether Pictographs are displayed according to study arm.
Primary Outcome. The primary outcome is wrong-patient order sessions, defined as a series of orders placed for a single patient by a single clinician that contains at least one wrong-patient order. The Wrong-Patient Retract-and-Reorder (RAR) measure--a validated, reliable, and automated method endorsed by the National Quality Forum (NQF #2723)--will be used to identify wrong-patient orders. The Wrong-Patient RAR measure identifies RAR events, defined as one or more orders placed for a patient that are retracted within 10 minutes, and then reordered by the same clinician for a different patient within the next 10 minutes. These are near-miss errors, caught by the clinician before they reach the patient. In the validation study, real-time telephone interviews with clinicians demonstrated that 76.2% of RAR events identified by the measure were confirmed to be wrong-patient orders. In a study conducted at a large academic medical center, the RAR measure identified more than 5,000 wrong-patient orders in 1 year. Thus, the RAR measure provides robust outcome data to test safety interventions.
Unit of Analysis. If a clinician begins placing orders in the wrong patient's record, several such orders may be placed consecutively and then retracted together. Therefore, individual orders do not represent independent opportunities for RAR events to occur, rather the order session represents an independent opportunity for an RAR event to occur. Thus, the unit of analysis is the order session, defined as a series of orders placed by a clinician for a single patient that begins with opening that patient's order file and terminates when an order is placed for another patient or after 60 minutes, whichever occurs first. The presence of Pictographs will be tracked as an order-session level characteristic.
Higher Level Units of Analysis. Order sessions are nested within both patient admission and clinician, and both patients and clinicians are nested within NICU. In the analysis, NICU will be treated as a fixed covariate, and clinicians are treated as an important source of variance and "cluster" unit of analysis because clinician is the unit of randomization.
Data Extraction and Management. Data will be extracted retrospectively for all orders (e.g., medications, laboratory tests, imaging studies, and other types) placed by randomized clinicians for patients receiving care in the study NICUs during the study period. Data for each order, including order, patient, and clinician characteristics, will be extracted from the health system data warehouse at each study site at the end of the study period. All patient and clinician identifiers will be replaced by pseudo-identifiers by research personnel at study sites to create de-identified analytic data sets, and data will be transferred electronically to the study biostatistician using a secure file transfer protocol.
Missing Data. Due to the automatic functioning of the EHR, no missing data concerning orders, RAR events, study group assignment, or provider-level covariates is expected. There may be missing information regarding patient-level covariates. If any variables are missing for more than 1 record per 1,000, analyses will be extended to address this. Data will be presumed to be missing at random and multiple imputation with chained equations will be applied.
Statistical Analysis Plan. Because order sessions are nested within clinicians, Aim 1 will be tested by estimating a multilevel mixed Poisson regression model predicting RAR event status (yes, no) with Group (Pictograph, coded 1, vs no Pictograph, coded 0) as the primary predictor and Multiple Status and NICU included as categorical covariates ("class" variables in SAS); the intercept will be treated as a random effect, assumed to vary among clinicians within each group. Because RAR events are rare (approximately 5 per 10,000 order sessions), the mixed Poisson regression model and the mixed logistic regression model yield nearly identical results with parameter estimates differing in the 3rd significant digit. The hypothesis will be confirmed if the RR for Group is significantly different from 1.0 (expected to be <1.0), based on the Wald chi-square test of BGroup; i.e., ln(RR).
To test Aim 2, a variant of the same multilevel Poisson regression model will be estimated in which the main effect of Group is replaced with the Multiple Status*Group interaction; this specification will yield two coefficients for Group, one for Singletons (Multiple Status=0) and one for Multiples (Multiple Status=1). The Wald chi-square test will be used to evaluate the statistical significance of each coefficient, i.e., the effect of Pictographs on RAR risk for singletons and for multiples. The SAS GLIMMIX procedure will be used to perform these analyses, and a 2-tailed, alpha=0.05 criterion will be used to evaluate statistical significance.
Secondary analyses will examine whether the effect of the Pictograph intervention varies across hospitals, by EHR vendor, by clinician type and other clinician characteristics, by patient characteristics, and/or by order session characteristics.
Statistical Power/Sample Size. The power was calculated using the O'Brien and Muller approach, an exemplary data set constructed by assumed population parameters to detect the hypothesized effect. It is estimated approximately 17,000 patients, infants admitted to the NICU at each site will be recruited, and verbal consent will be obtained from parents or legal guardians. The number of clinicians is a fixed attribute of the study sites and is not subject to investigator control. Based on preliminary data, it is assumed that data will be obtained on 6,250 clinicians, with half randomized to each study arm. With respect to Aim 1, if the effect sizes are reductions of 30% for singletons and 50% for multiples, as hypothesized, the study will have 98% power to detect a significant benefit of Pictographs on RAR event rate. By changing the weights described above to 0.75 and 0.25 for both singletons and multiples, it is estimated that the study will have 81% power to detect an overall reduction, across singletons and multiples, of 25% in RAR event rate. Using the mean standard error, the calculated power for Aim 2 of the proposed study: for singletons, the power to detect the hypothesized 30% reduction in RAR rate is 89%; for multiples, the power to detect a 50% reduction is 95%. Minimum effect sizes detectable with 80% power are reductions of 27% for singletons and 42% for multiples.
Interim Analysis. At the midpoint of the study, the Lan-Demets algorithm will be applied for early termination with an O'Brien-Fleming boundary function to preserve overall Type I error rate. At the interim review, the corresponding stopping points correspond to a z-statistic for the primary hypothesis test of ±2.9626. To avoid bias in these judgments, the data sets will contain interim results for the two arms but will not identify which arm is the intervention. A test of futility will be conducted, by treating the expected result of 25% reduction as a null hypothesis. If that hypothesis test is rejected at the 1-tailed 0.001 level, continuation will be considered futile and will conclude the study.
Recruitment/Enrollment. A nurse involved in patient care will inform parents or guardians of infants admitted to the NICU about the study. The nurse will obtain verbal consent to display the Pictograph on the infant's isolette and in the infant's medical record in the EHR for the duration of the infant's hospital stay. Parents who provide verbal consent will select a unique Pictograph for each infant using the Pictograph Application on an electronic tablet. The Pictograph Application is a HIPAA-compliant, secure web-based application that enables Pictograph selection, customization, printing, and uploading to the EHR. Parents with multiple infants in the NICU will select a different Pictograph for each infant. Selected Pictographs become unavailable such that no two infants will have the same Pictograph at the same time in the NICU. The selected Pictograph will be printed and attached to the isolette, and uploaded into the EHR using the same functionality used to upload and display patient photographs. When the infant is discharged, the Pictograph will be removed from the isolette and from the EHR; that image will remain unavailable for use for 2 weeks after the infant is discharged.
- Conditions
- Medical Errors, Electronic Medical Records
- Being tested
- Pictograph in Banner and Verification Alert
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Pictograph in Banner and Verification AlertBehavioural
Patient Pictograph will be displayed in the banner at the top of the screen in the electronic health record AND patient Pictograph displayed in a patient ID verification alert when placing electronic orders in the electronic health record.
| Study group | Role | What they receive |
|---|---|---|
| Pictograph in Banner and Verification Alert | Active comparator | Patient Pictograph displayed in the banner (at the top of the screen) AND Pictograph displayed in a verification alert when placing electronic orders. Receives: Behavioral: Pictograph in Banner and Verification Alert |
| No Pictograph | No intervention | No patient Pictographs displayed in the electronic health record. |
What is being measured
The primary outcome is the main question the study is designed to answer.
Wrong-patient order sessions that contain at least one Retract-and-Reorder (RAR) event as identified by the Wrong-Patient Retract-and-Reorder (RAR) measure.
The primary outcome is wrong-patient order sessions, defined as a series of orders placed for a single patient by a single clinician that contains at least one wrong-patient order. We will use the Wrong-Patient Retract-and-Reorder (RAR) measure, a validated, reliable, and automated method endorsed by the National Quality Forum (NQF #2723) to identify wrong-patient orders. The Wrong-Patient RAR measure identifies RAR events, defined as one or more orders placed for a patient that are retracted within 10 minutes, and then reordered by the same clinician for a different patient within the next 10 minutes.
Measured: 2.5 years
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted22 May 2019
- Study start16 Mar 2022
- Primary completion30 Jun 2027 (estimated)
- Study completion30 Jun 2028 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (5)Papers the sponsor has linked to this study.
- Other trials for Medical ErrorsStudies of the same condition, open and under way.
- More trials run by Columbia UniversityThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Health services research
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Enrolment
- 6,250 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Columbia University
- Sponsor type
- University, hospital or other
- Collaborators
- Albert Einstein College of Medicine, Johns Hopkins University, Brigham and Women's Hospital, Weill Medical College of Cornell University, Eunice Kennedy Shriver National Institute of Child Health and Human Development (NICHD)
- Responsible party
- Principal investigator, Jason Adelman, Columbia University
- Investigators
- Jason Adelman, MD, MS, Principal investigator, Columbia University
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT03960099
- Sponsor's protocol ID
- AAAR0080 - 2
- Other IDs
- 5R01HD094793-05
- Status last verified
- Mar 2026
- First submitted
- 20 May 2019
- Last updated
- 16 Mar 2026
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Yes: Data will be shared with qualified investigators whose research protocols have been IRB-approved by their institutions. The final data set will include retract-and-reorder events (representing near-miss, wrong-patient errors), as well as clinician, patient, and order level characteristics. The final data set will be de-identified, with personal identifiers replaced with pseudo-identifiers. Data will be made available to potential users under a data-sharing agreement that ensures that: (1) data are used only for research purposes and does identify individual participants; (2) data are handled in a secure and confidential way; and (3) data are destroyed or returned after analyses are completed.
Publications
Adelman JS, Kalkut GE, Schechter CB, Weiss JM, Berger MA, Reissman SH, Cohen HW, Lorenzen SJ, Burack DA, Southern WN. Understanding and preventing wrong-patient electronic orders: a randomized controlled trial. J Am Med Inform Assoc. 2013 Mar-Apr;20(2):305-10. doi: 10.1136/amiajnl-2012-001055. Epub 2012 Jun 29.
PubMed 22753810Adelman JS, Aschner JL, Schechter CB, Angert RM, Weiss JM, Rai A, Berger MA, Reissman SH, Yongue C, Chacko B, Dadlez NM, Applebaum JR, Racine AD, Southern WN. Evaluating Serial Strategies for Preventing Wrong-Patient Orders in the NICU. Pediatrics. 2017 May;139(5):e20162863. doi: 10.1542/peds.2016-2863.
PubMed 28557730Adelman JS, Aschner JL, Schechter CB, Angert RM, Weiss JM, Rai A, Parakkattu V, Goffman D, Applebaum JR, Racine AD, Southern WN. Babyboy/Babygirl: A National Survey on the Use of Temporary, Nondistinct Naming Conventions for Newborns in Neonatal Intensive Care Units. Clin Pediatr (Phila). 2017 Oct;56(12):1157-1159. doi: 10.1177/0009922817701178. Epub 2017 Apr 12. No abstract available.
PubMed 28403654Adelman JS, Applebaum JR, Schechter CB, Berger MA, Reissman SH, Thota R, Racine AD, Vawdrey DK, Green RA, Salmasian H, Schiff GD, Wright A, Landman A, Bates DW, Koppel R, Galanter WL, Lambert BL, Paparella S, Southern WN. Effect of Restriction of the Number of Concurrently Open Records in an Electronic Health Record on Wrong-Patient Order Errors: A Randomized Clinical Trial. JAMA. 2019 May 14;321(18):1780-1787. doi: 10.1001/jama.2019.3698.
PubMed 31087021Adelman J, Aschner J, Schechter C, Angert R, Weiss J, Rai A, Berger M, Reissman S, Parakkattu V, Chacko B, Racine A, Southern W. Use of Temporary Names for Newborns and Associated Risks. Pediatrics. 2015 Aug;136(2):327-33. doi: 10.1542/peds.2015-0007. Epub 2015 Jul 13.
PubMed 26169429
Study at a glance
From the registry record, last updated by the sponsor on 16 Mar 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Assessing the Effectiveness of Pictographs for Preventing Wrong-Patient Errors in Neonatal Intensive Care Units: A Randomized Controlled Trial
- ClinicalTrials.gov ID
- NCT03960099
- Acronym / sponsor ID
- AAAR0080 - 2
- Conditions
- Medical Errors, Electronic Medical Records
- Study type
- Interventional
- Recruitment status
- Recruiting
- Enrolment
- 6,250 participants (estimated)
- Lead sponsor
- Columbia UniversityUniversity, hospital or other
- Collaborators
- Albert Einstein College of Medicine, Johns Hopkins University, Brigham and Women's Hospital, Weill Medical College of Cornell University, Eunice Kennedy Shriver National Institute of Child Health and Human Development (NICHD)
- Study start
- 16 Mar 2022 (actual)
- Primary completion
- 30 Jun 2027 (estimated)
- Study completion
- 30 Jun 2028 (estimated)
- First posted
- 22 May 2019 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Newborns in the neonatal intensive care unit (NICU) are at high risk for wrong-patient errors. Effective 2019, The Joint Commission requires that health systems adopt distinct methods of newborn identification as part of its National Patient Safety Goals. Displaying patient photographs in the electronic health record (EHR) is a promising strategy to improve identification of children and adults, but is unlikely to be effective for identifying newborns. This study assesses the use of Pictographs as a "photo equivalent" for improving identification of newborns in the NICU.
This multi-site, two-arm, parallel group, cluster randomized controlled trial will test the effectiveness of Pictographs for preventing wrong-patient order errors in the NICU. Pictographs consist of three elements: 1) pictorial symbols of easy-to-remember objects (e.g., rainbow, lion); 2) the infant's given name (when available); and 3) a color-coded border indicating the infant's sex. The study will be conducted at three academic medical centers that utilize Epic EHR. All parents or guardians will be asked to select a unique Pictograph for each infant admitted to the NICU to be displayed on the isolette and in the EHR for the duration of the infant's hospital stay. All clinicians with the authority to place electronic orders in the study NICUs will be randomly assigned to either the intervention arm (Pictographs displayed in the EHR) or the control arm (no Pictographs displayed in the EHR). The main hypothesis is that clinicians assigned to view Pictographs in the EHR will have a significantly lower rate of wrong-patient order errors in the NICU versus clinicians assigned to no Pictographs.
The primary outcome is wrong-patient order sessions, defined as a series of orders placed for a single patient by a single clinician that contains at least one wrong-patient order. The Wrong-Patient Retract-and-Reorder (RAR) measure, a validated, reliable, and automated method for identifying wrong-patient orders, will be used as the primary outcome measure. The Wrong-Patient RAR measure identifies one or more orders placed for a patient that are retracted within 10 minutes, and then reordered by the same clinician for a different patient within the next 10 minutes. In the validation study conducted at a large academic medical center, real-time telephone interviews with clinicians confirmed that 76.2% of RAR events were correctly identified by the measure as wrong-patient orders.
Detailed description
BACKGROUND
Newborns in the neonatal intensive care unit (NICU) are at high risk for wrong-patient errors. Effective 2019, The Joint Commission requires that health systems adopt distinct methods of newborn identification to prevent this type of error as part of its National Patient Safety Goals. Displaying patient photographs in the electronic health record (EHR) is a promising strategy to improve identification of children and adults, but photographs are not likely to be effective for identifying newborns. Therefore, this study assesses the use of Pictographs as a "photo equivalent" for improving identification of newborns in the NICU.
METHODS
The primary hypothesis of this study is that clinicians randomly assigned to view Pictographs in the EHR (intervention arm) will have a significantly lower rate of wrong-patient order errors in the neonatal intensive care unit (NICU) compared to clinicians assigned to view no Pictographs in the EHR (control arm). The secondary hypothesis is that the rate of wrong-patient orders for siblings of multiple births in the NICU will be significantly lower for clinicians randomized to the intervention versus control arm.
The study will pursue the following specific aims:
Aim 1: Test the effectiveness of displaying Pictographs in EHR systems for reducing wrong-patient orders among infants in the NICU, using the Wrong-Patient Retract-and-Reorder measure to identify the outcome.
Aim 2: Conduct subgroup analyses of the effectiveness of Pictographs for reducing the rates of wrong-patient orders among siblings of multiple-birth infants in the NICU.
Design. This multi-site, two-arm, parallel-group, cluster randomized controlled trial will test the effectiveness of Pictographs for preventing wrong-patient order errors in the NICUs of three health systems. Pictographs consist of three elements: 1) pictorial symbols of easy-to-remember objects (e.g., rainbow, lion); 2) the infant's given name (when available); and 3) a color-coded border indicating the infant's sex. For each infant admitted to the study NICUs, parents or guardians will be asked to select a unique Pictograph to be displayed on the isolette and in the EHR for the duration of each infant's hospital stay. Clinicians randomized to the intervention arm will see a Pictograph displayed in the banner and verification alert in the EHR. Clinicians randomized to the control arm will not see Pictographs in the EHR.
Study Sites. The study includes NICUs at the following participating study institutions representing diverse patient populations: NewYork-Presbyterian Hospital, New York, NY; Montefiore Medical Center, Bronx, NY; and Johns Hopkins Medicine, Baltimore, MD. All sites will conduct the study in EpicCare (Epic Systems Corporation, Verona, WI).
Patient Inclusion Criteria. All infants admitted to the study NICUs will be eligible to be included.
Clinician Inclusion Criteria. All clinicians who place electronic orders in the NICU at the study sites during the study period will be included.
Randomization. The clinician is the unit of randomization. Each ordering clinician will be randomly assigned to a study arm in a 1:1 random allocation scheme using a computer random number generator program at all study sites. Then, clinicians will be assigned, as randomized, to groupers built into Epic to apply configuration rules that dictate whether Pictographs are displayed according to study arm.
Primary Outcome. The primary outcome is wrong-patient order sessions, defined as a series of orders placed for a single patient by a single clinician that contains at least one wrong-patient order. The Wrong-Patient Retract-and-Reorder (RAR) measure--a validated, reliable, and automated method endorsed by the National Quality Forum (NQF #2723)--will be used to identify wrong-patient orders. The Wrong-Patient RAR measure identifies RAR events, defined as one or more orders placed for a patient that are retracted within 10 minutes, and then reordered by the same clinician for a different patient within the next 10 minutes. These are near-miss errors, caught by the clinician before they reach the patient. In the validation study, real-time telephone interviews with clinicians demonstrated that 76.2% of RAR events identified by the measure were confirmed to be wrong-patient orders. In a study conducted at a large academic medical center, the RAR measure identified more than 5,000 wrong-patient orders in 1 year. Thus, the RAR measure provides robust outcome data to test safety interventions.
Unit of Analysis. If a clinician begins placing orders in the wrong patient's record, several such orders may be placed consecutively and then retracted together. Therefore, individual orders do not represent independent opportunities for RAR events to occur, rather the order session represents an independent opportunity for an RAR event to occur. Thus, the unit of analysis is the order session, defined as a series of orders placed by a clinician for a single patient that begins with opening that patient's order file and terminates when an order is placed for another patient or after 60 minutes, whichever occurs first. The presence of Pictographs will be tracked as an order-session level characteristic.
Higher Level Units of Analysis. Order sessions are nested within both patient admission and clinician, and both patients and clinicians are nested within NICU. In the analysis, NICU will be treated as a fixed covariate, and clinicians are treated as an important source of variance and "cluster" unit of analysis because clinician is the unit of randomization.
Data Extraction and Management. Data will be extracted retrospectively for all orders (e.g., medications, laboratory tests, imaging studies, and other types) placed by randomized clinicians for patients receiving care in the study NICUs during the study period. Data for each order, including order, patient, and clinician characteristics, will be extracted from the health system data warehouse at each study site at the end of the study period. All patient and clinician identifiers will be replaced by pseudo-identifiers by research personnel at study sites to create de-identified analytic data sets, and data will be transferred electronically to the study biostatistician using a secure file transfer protocol.
Missing Data. Due to the automatic functioning of the EHR, no missing data concerning orders, RAR events, study group assignment, or provider-level covariates is expected. There may be missing information regarding patient-level covariates. If any variables are missing for more than 1 record per 1,000, analyses will be extended to address this. Data will be presumed to be missing at random and multiple imputation with chained equations will be applied.
Statistical Analysis Plan. Because order sessions are nested within clinicians, Aim 1 will be tested by estimating a multilevel mixed Poisson regression model predicting RAR event status (yes, no) with Group (Pictograph, coded 1, vs no Pictograph, coded 0) as the primary predictor and Multiple Status and NICU included as categorical covariates ("class" variables in SAS); the intercept will be treated as a random effect, assumed to vary among clinicians within each group. Because RAR events are rare (approximately 5 per 10,000 order sessions), the mixed Poisson regression model and the mixed logistic regression model yield nearly identical results with parameter estimates differing in the 3rd significant digit. The hypothesis will be confirmed if the RR for Group is significantly different from 1.0 (expected to be <1.0), based on the Wald chi-square test of BGroup; i.e., ln(RR).
To test Aim 2, a variant of the same multilevel Poisson regression model will be estimated in which the main effect of Group is replaced with the Multiple Status*Group interaction; this specification will yield two coefficients for Group, one for Singletons (Multiple Status=0) and one for Multiples (Multiple Status=1). The Wald chi-square test will be used to evaluate the statistical significance of each coefficient, i.e., the effect of Pictographs on RAR risk for singletons and for multiples. The SAS GLIMMIX procedure will be used to perform these analyses, and a 2-tailed, alpha=0.05 criterion will be used to evaluate statistical significance.
Secondary analyses will examine whether the effect of the Pictograph intervention varies across hospitals, by EHR vendor, by clinician type and other clinician characteristics, by patient characteristics, and/or by order session characteristics.
Statistical Power/Sample Size. The power was calculated using the O'Brien and Muller approach, an exemplary data set constructed by assumed population parameters to detect the hypothesized effect. It is estimated approximately 17,000 patients, infants admitted to the NICU at each site will be recruited, and verbal consent will be obtained from parents or legal guardians. The number of clinicians is a fixed attribute of the study sites and is not subject to investigator control. Based on preliminary data, it is assumed that data will be obtained on 6,250 clinicians, with half randomized to each study arm. With respect to Aim 1, if the effect sizes are reductions of 30% for singletons and 50% for multiples, as hypothesized, the study will have 98% power to detect a significant benefit of Pictographs on RAR event rate. By changing the weights described above to 0.75 and 0.25 for both singletons and multiples, it is estimated that the study will have 81% power to detect an overall reduction, across singletons and multiples, of 25% in RAR event rate. Using the mean standard error, the calculated power for Aim 2 of the proposed study: for singletons, the power to detect the hypothesized 30% reduction in RAR rate is 89%; for multiples, the power to detect a 50% reduction is 95%. Minimum effect sizes detectable with 80% power are reductions of 27% for singletons and 42% for multiples.
Interim Analysis. At the midpoint of the study, the Lan-Demets algorithm will be applied for early termination with an O'Brien-Fleming boundary function to preserve overall Type I error rate. At the interim review, the corresponding stopping points correspond to a z-statistic for the primary hypothesis test of ±2.9626. To avoid bias in these judgments, the data sets will contain interim results for the two arms but will not identify which arm is the intervention. A test of futility will be conducted, by treating the expected result of 25% reduction as a null hypothesis. If that hypothesis test is rejected at the 1-tailed 0.001 level, continuation will be considered futile and will conclude the study.
Recruitment/Enrollment. A nurse involved in patient care will inform parents or guardians of infants admitted to the NICU about the study. The nurse will obtain verbal consent to display the Pictograph on the infant's isolette and in the infant's medical record in the EHR for the duration of the infant's hospital stay. Parents who provide verbal consent will select a unique Pictograph for each infant using the Pictograph Application on an electronic tablet. The Pictograph Application is a HIPAA-compliant, secure web-based application that enables Pictograph selection, customization, printing, and uploading to the EHR. Parents with multiple infants in the NICU will select a different Pictograph for each infant. Selected Pictographs become unavailable such that no two infants will have the same Pictograph at the same time in the NICU. The selected Pictograph will be printed and attached to the isolette, and uploaded into the EHR using the same functionality used to upload and display patient photographs. When the infant is discharged, the Pictograph will be removed from the isolette and from the EHR; that image will remain unavailable for use for 2 weeks after the infant is discharged.
Study design
- Primary purpose
- Health services research
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- None (open label)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Pictograph in Banner and Verification Alert | Active comparator | Behavioral: Pictograph in Banner and Verification AlertPatient Pictograph displayed in the banner (at the top of the screen) AND Pictograph displayed in a verification alert when placing electronic orders. |
| No Pictograph | No intervention | –No patient Pictographs displayed in the electronic health record. |
Who may qualify
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Child, Adult, Older adult
Key inclusion criteria (2 listed)
- All infants receiving care in the study NICUs for whom an order was placed during the study period.
- All clinicians with the authority to place electronic orders in the NICU and who placed electronic orders during the study period.
Key exclusion criteria (1 listed)
- None
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Pictograph in Banner and Verification AlertPatient Pictograph will be displayed in the banner at the top of the screen in the electronic health record AND patient Pictograph displayed in a patient ID verification alert when placing electronic orders in the electronic health record. | Behavioural | Pictograph in Banner and Verification Alert |
Primary outcome
Wrong-patient order sessions that contain at least one Retract-and-Reorder (RAR) event as identified by the Wrong-Patient Retract-and-Reorder (RAR) measure.
Time frame: 2.5 years
The primary outcome is wrong-patient order sessions, defined as a series of orders placed for a single patient by a single clinician that contains at least one wrong-patient order. We will use the Wrong-Patient Retract-and-Reorder (RAR) measure, a validated, reliable, and automated method endorsed by the National Quality Forum (NQF #2723) to identify wrong-patient orders. The Wrong-Patient RAR measure identifies RAR events, defined as one or more orders placed for a patient that are retracted within 10 minutes, and then reordered by the same clinician for a different patient within the next 10 minutes.
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 16 Mar 2026.
- Background: PubMed 22753810Adelman JS, Kalkut GE, Schechter CB, Weiss JM, Berger MA, Reissman SH, Cohen HW, Lorenzen SJ, Burack DA, Southern WN. Understanding and preventing wrong-patient electronic orders: a randomized controlled trial. J Am Med Inform Assoc. 2013 Mar-Apr;20(2):305-10. doi: 10.1136/amiajnl-2012-001055. Epub 2012 Jun 29.
- Background: PubMed 28557730Adelman JS, Aschner JL, Schechter CB, Angert RM, Weiss JM, Rai A, Berger MA, Reissman SH, Yongue C, Chacko B, Dadlez NM, Applebaum JR, Racine AD, Southern WN. Evaluating Serial Strategies for Preventing Wrong-Patient Orders in the NICU. Pediatrics. 2017 May;139(5):e20162863. doi: 10.1542/peds.2016-2863.
- Background: PubMed 28403654Adelman JS, Aschner JL, Schechter CB, Angert RM, Weiss JM, Rai A, Parakkattu V, Goffman D, Applebaum JR, Racine AD, Southern WN. Babyboy/Babygirl: A National Survey on the Use of Temporary, Nondistinct Naming Conventions for Newborns in Neonatal Intensive Care Units. Clin Pediatr (Phila). 2017 Oct;56(12):1157-1159. doi: 10.1177/0009922817701178. Epub 2017 Apr 12. No abstract available.
- Background: PubMed 31087021Adelman JS, Applebaum JR, Schechter CB, Berger MA, Reissman SH, Thota R, Racine AD, Vawdrey DK, Green RA, Salmasian H, Schiff GD, Wright A, Landman A, Bates DW, Koppel R, Galanter WL, Lambert BL, Paparella S, Southern WN. Effect of Restriction of the Number of Concurrently Open Records in an Electronic Health Record on Wrong-Patient Order Errors: A Randomized Clinical Trial. JAMA. 2019 May 14;321(18):1780-1787. doi: 10.1001/jama.2019.3698.
- Background: PubMed 26169429Adelman J, Aschner J, Schechter C, Angert R, Weiss J, Rai A, Berger M, Reissman S, Parakkattu V, Chacko B, Racine A, Southern W. Use of Temporary Names for Newborns and Associated Risks. Pediatrics. 2015 Aug;136(2):327-33. doi: 10.1542/peds.2015-0007. Epub 2015 Jul 13.
- Individual participant dataSharing planned: Yes. Data will be shared with qualified investigators whose research protocols have been IRB-approved by their institutions. The final data set will include retract-and-reorder events (representing near-miss, wrong-patient errors), as well as clinician, patient, and order level characteristics. The final data set will be de-identified, with personal identifiers replaced with pseudo-identifiers. Data will be made available to potential users under a data-sharing agreement that ensures that: (1) data are used only for research purposes and does identify individual participants; (2) data are handled in a secure and confidential way; and (3) data are destroyed or returned after analyses are completed.
Related trials for Medical Errors
Active, not recruiting
Evaluation of the Effect of a Low-FODMAP Diet on Gastrointestinal Symptoms and Inflammatory Markers in Fabry Patients
Fabry Disease
RecruitingObservational study
Establishment of Genomic and Phenotypic Database for Niemann-Pick Disease, Type C
Niemann-Pick Disease, Type C
RecruitingObservational study
Abbott Vascular Medical Device Registry
Acute Myocardial Infarction, Restenoses, Coronary
Not yet recruiting
AI-Based Quality Control for Radiology Reporting
Radiology, Medical Errors
Not yet recruitingObservational study
Specialist Review of Harm Ratings for Clinical Responses Acronym: NOHARM
Patient Safety, Medical Errors
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Jason Adelman, MD, MS principal investigator
Columbia University
4 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Pictograph in Banner and Verification Alert in people with Medical Errors and Electronic Medical Records, run by Columbia University at 4 sites in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 2 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: looking for participants now, as of the sponsor's last update on 16 Mar 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 4 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Jason Adelman, MD, MS (646-317-4803, jsa2163@cumc.columbia.edu), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Wrong-patient order sessions that contain at least one Retract-and-Reorder (RAR) event as identified by the Wrong-Patient Retract-and-Reorder (RAR) measure. (time frame: 2.5 years). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT03960099, which also lists 5 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 16 Mar 2026.