Low VisionRGPIRIS_PANCT04040790
Performance of Rigid Gas Permeable (RGP) Scleral Contact Lenses With a Passive Artificial Iris
A study testing Scleral contact lens without a passive artificial iris, Scleral contact lens with a passive artificial iris with low contrast (<1:5) and Scleral contact lens with a passive artificial iris with high contrast (>1:5) in people with Low Vision, run by University Ghent at 1 site in Belgium.
Trial summary
Data from 15 healthy subjects will be recorded in two testing sessions spread on two days, using three lens designs (A, B and C). Before the measuring days, each subject will undergo an extra fitting session of a large-diameter scleral contact lens on the dominant eye, assessed by an experienced practitioner. Read more about this study
- Who is it for?
- Ages 18 to 45 yearsHealthy volunteers can take part
- Conditions the study is for
- Low Vision
- What is being tested?
- Scleral contact lens without a passive artificial iris, Scleral contact lens with a passive artificial iris with low contrast (<1:5) and Scleral contact lens with a passive artificial iris with high contrast (>1:5)
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 10 participants
- Where
- 1 siteBelgium
- Study dates
- 16 Sep 2019to 22 Jun 2021
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 45 years
- All sexes
- Healthy volunteers accepted
- Adult
Who may be able to join
- Age between 18 and 45 years old
Who cannot join
- Iris disorders (i.e. ocular albinism, coloboma, aniridia).
- Known disease-related ocular surface problem (i.e. microbial keratitis).
- Known ocular pathologies (except refractive disorders).
- Coexistent ocular diseases impeding contact lens correction (i.e. glaucoma, previous ocular surgery).
- Corneal scarring.
- Low corneal endothelial cell count (< 1500 cells per mm2), with potential of corneal hypoxia-induced corneal edema induced by contact lens wear.
- Wearing of contact lenses in the last 24 hours (prior to the interventions).
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Evaluation of Light Sensitivity and Visual Acuity Changes as Consequence of Rigid Gas Permeable (RGP) Scleral Contact Lenses With a Passive Artificial Iris
Data from 15 healthy subjects will be recorded in two testing sessions spread on two days, using three lens designs (A, B and C). Before the measuring days, each subject will undergo an extra fitting session of a large-diameter scleral contact lens on the dominant eye, assessed by an experienced practitioner. The fitting data will be used to custom-make the three lens designs for each subject, thus ensuring their comfort and safety during the days of the experiments. During the experiment days baseline measurements will be obtained before and after pupil dilation and contact lens wear. During the first testing session data from the lens design A (reference lens without artificial iris) will be recorded. During the second testing session data from the lens designs B and C (lenses with artificial iris with different transmittances) will be recorded. In each testing session, contrast sensitivity and visual acuity will be evaluated and non-invasive imaging measurements will be undertaken (optical coherence tomography and slit lamp). A specific questionnaire will be given to the subject to assess comfort, light sensitivity, the horizontal visual angle and overall experience of the scleral lens and in combination with a pair of sunglasses category 3-4.
Read the detailed description
First, the participant will be subjected to an RGP scleral contact lens fitting session, then during the second and third visits the participant will be subjected to several non-invasive procedures specific to the study in order to assess contrast sensitivity and visual acuity using the fitted and uniquely fabricated investigational medical devices. The tests will be performed after eye drops are supplied to dilate the pupil of the subjects (eye drops: tropicamide and phenylephrine). Besides the clinical experiments, the participant will be given a specific questionnaire in order to assess comfort, light sensitivity, horizontal visual angle and overall experience of the investigational medical device and in combination with a pair of sunglasses category 3-4. The investigators will document the occurrence of any adverse events and specific side effects during Day 2 and 3 (testing sessions with the investigational devices) in order to effectively assess their safety.
- Conditions
- Low Vision
- Being tested
- Scleral contact lens without a passive artificial iris, Scleral contact lens with a passive artificial iris with low contrast (<1:5), Scleral contact lens with a passive artificial iris with high contrast (>1:5), Tropicamide and phenylephrine
- Keywords
- visual acuity, contrast sensitivity, scleral contact lens, artificial iris
- Medical subject headings
- Vision, Low
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Scleral contact lens without a passive artificial irisDevice
Also called Control lens Design A
Participants wear a scleral contact lens without a passive artificial iris (Design A) on the dominant eye to perform the baseline visual performance assessment
Scleral contact lens with a passive artificial iris with low contrast (<1:5)Device
Also called Test lens Design B
Participants wear a scleral contact lens with a low contrast (<1:5) passive artificial iris (Design B) on the dominant eye to perform the baseline visual performance assessment
Scleral contact lens with a passive artificial iris with high contrast (>1:5)Device
Participants wear a scleral contact lens with a low contrast (<1:5) passive artificial iris (Design B) on the dominant eye to perform the baseline visual performance assessment
Tropicamide and phenylephrineDrug
Also called Pupil dilation eye drops
Participants receive pupil dilation eye drops on the dominant eye, after baseline measurement and before wearing the scleral contact lenses (Designs A, B and C)
| Study group | Role | What they receive |
|---|---|---|
| Healthy volunteers | Experimental | 15 healthy volunteers for trials with passive artificial iris Receives: Device: Scleral contact lens without a passive artificial iris; Device: Scleral contact lens with a passive artificial iris with low contrast (<1:5); Device: Scleral contact lens with a passive artificial iris with high contrast (>1:5); Drug: Tropicamide and phenylephrine |
What is being measured
The primary outcome is the main question the study is designed to answer.
Visual acuity assessment and comparison between Designs A, B and C by means of logMAR or equivalent value
Compare visual acuity values obtained with different designs
Measured: 5 months from fitting session
Contrast sensitivity assessment and comparison between Designs A, B and C by means of threshold percentage or equivalent value
Compare contrast sensitivity values obtained with different designs
Measured: 5 months from fitting session
Secondary outcomes (6)
Device safety by comparing eventual adverse events with those found in scleral contact lenses
Comparing adverse event of similar devices
Measured: 5 months from fitting session
Correct fitting
Taking and analyzing ocular coherence tomography (OCT) images and slit lamp observations to estimate the clearance
Measured: 5 months from fitting session
Contact lens wear comfort, as assessed by subject data from questionnaires Rasch analyzed using a 4-Andrich ration scale model
The subjective assessment will be carried out by means of questions on 3 content areas: lens comfort (3 questions), visual quality (4 questions) and general satisfaction with the lenses (3 questions).
Measured: 5 months from fitting session
Visual acuity assessment and comparison between Designs B (low contrast) and C (high contrast) by means of logMAR or equivalent value
Comparing visual acuity between Designs B and C
Measured: 5 months from fitting session
Contrast sensitivity assessment and comparison between Designs B (low contrast) and C (high contrast) by means of threshold percentage or equivalent value
Comparing contrast sensitivity between Designs B and C
Measured: 5 months from fitting session
Horizontal visual angle
Angle at which the volunteer can see his fingers move when extending the arm (same side as dominant eye), 0°=arm extended to the side; 90°=arm straight ahead
Measured: 5 months from fitting session
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted1 Aug 2019
- Study start16 Sep 2019
- Primary completion22 Jun 2021
- Study completion22 Jun 2021
Why it stopped: Several reasons: Financing ended before all study assessments were performed, covid-19 delayed design, production and shipment of IMD, experience gained during the study made it clear that lens design should be changed
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (6)Papers the sponsor has linked to this study.
- Other trials for Low VisionStudies of the same condition, open and under way.
- More trials run by University GhentThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 10 participants (actual)
Sponsor and investigators
- Lead sponsor
- University Ghent
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- Andres F Vasquez Quintero, Professor, Study chair, University Ghent
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04040790
- Sponsor's protocol ID
- RGPIRIS_PA
- Acronym
- RGPIRIS_PA
- Status last verified
- Nov 2021
- First submitted
- 13 Jun 2019
- Last updated
- 27 Apr 2022
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
Garcia-Lazaro S, Ferrer-Blasco T, Radhakrishnan H, Cervino A, Charman WN, Montes-Mico R. Visual function through 4 contact lens-based pinhole systems for presbyopia. J Cataract Refract Surg. 2012 May;38(5):858-65. doi: 10.1016/j.jcrs.2011.11.042. Epub 2012 Mar 16.
PubMed 22424803Pepose JS. Small-aperture contact lenses for presbyopia. J Cataract Refract Surg. 2012 Nov;38(11):2060-1; author reply 2062-4. doi: 10.1016/j.jcrs.2012.08.041. No abstract available.
PubMed 23079328Xu R, Gil D, Dibas M, Hare W, Bradley A. The Effect of Light Level and Small Pupils on Presbyopic Reading Performance. Invest Ophthalmol Vis Sci. 2016 Oct 1;57(13):5656-5664. doi: 10.1167/iovs.16-20008.
PubMed 27784070Eyeson-Annan ML, Hirst LW, Battistutta D, Green A. Comparative pupil dilation using phenylephrine alone or in combination with tropicamide. Ophthalmology. 1998 Apr;105(4):726-32. doi: 10.1016/S0161-6420(98)94030-1.
PubMed 9544648Compan V, Oliveira C, Aguilella-Arzo M, Molla S, Peixoto-de-Matos SC, Gonzalez-Meijome JM. Oxygen diffusion and edema with modern scleral rigid gas permeable contact lenses. Invest Ophthalmol Vis Sci. 2014 Sep 4;55(10):6421-9. doi: 10.1167/iovs.14-14038.
PubMed 25190661Holden BA, Mertz GW. Critical oxygen levels to avoid corneal edema for daily and extended wear contact lenses. Invest Ophthalmol Vis Sci. 1984 Oct;25(10):1161-7.
PubMed 6592160
Study at a glance
From the registry record, last updated by the sponsor on 27 Apr 2022. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Evaluation of Light Sensitivity and Visual Acuity Changes as Consequence of Rigid Gas Permeable (RGP) Scleral Contact Lenses With a Passive Artificial Iris
- ClinicalTrials.gov ID
- NCT04040790
- Acronym / sponsor ID
- RGPIRIS_PA / RGPIRIS_PA
- Conditions
- Low Vision
- Keywords
- visual acuity, contrast sensitivity, scleral contact lens, artificial iris
- Study type
- Interventional
- Recruitment status
- TerminatedReason stopped: Several reasons: Financing ended before all study assessments were performed, covid-19 delayed design, production and shipment of IMD, experience gained during the study made it clear that lens design should be changed
- Enrolment
- 10 participants (actual)
- Lead sponsor
- University GhentUniversity, hospital or other
- Study start
- 16 Sep 2019 (actual)
- Primary completion
- 22 Jun 2021 (actual)
- Study completion
- 22 Jun 2021 (actual)
- First posted
- 1 Aug 2019 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Data from 15 healthy subjects will be recorded in two testing sessions spread on two days, using three lens designs (A, B and C). Before the measuring days, each subject will undergo an extra fitting session of a large-diameter scleral contact lens on the dominant eye, assessed by an experienced practitioner. The fitting data will be used to custom-make the three lens designs for each subject, thus ensuring their comfort and safety during the days of the experiments. During the experiment days baseline measurements will be obtained before and after pupil dilation and contact lens wear. During the first testing session data from the lens design A (reference lens without artificial iris) will be recorded. During the second testing session data from the lens designs B and C (lenses with artificial iris with different transmittances) will be recorded. In each testing session, contrast sensitivity and visual acuity will be evaluated and non-invasive imaging measurements will be undertaken (optical coherence tomography and slit lamp). A specific questionnaire will be given to the subject to assess comfort, light sensitivity, the horizontal visual angle and overall experience of the scleral lens and in combination with a pair of sunglasses category 3-4.
Detailed description
First, the participant will be subjected to an RGP scleral contact lens fitting session, then during the second and third visits the participant will be subjected to several non-invasive procedures specific to the study in order to assess contrast sensitivity and visual acuity using the fitted and uniquely fabricated investigational medical devices. The tests will be performed after eye drops are supplied to dilate the pupil of the subjects (eye drops: tropicamide and phenylephrine). Besides the clinical experiments, the participant will be given a specific questionnaire in order to assess comfort, light sensitivity, horizontal visual angle and overall experience of the investigational medical device and in combination with a pair of sunglasses category 3-4. The investigators will document the occurrence of any adverse events and specific side effects during Day 2 and 3 (testing sessions with the investigational devices) in order to effectively assess their safety.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Healthy volunteers | Experimental | Device: Scleral contact lens without a passive artificial iris, Device: Scleral contact lens with a passive artificial iris with low contrast (<1:5), Device: Scleral contact lens with a passive artificial iris with high contrast (>1:5), Drug: Tropicamide and phenylephrine15 healthy volunteers for trials with passive artificial iris |
Who may qualify
- Ages
- 18 to 45 years
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult
Key inclusion criteria (1 listed)
- Age between 18 and 45 years old
Key exclusion criteria (7 listed)
- Iris disorders (i.e. ocular albinism, coloboma, aniridia).
- Known disease-related ocular surface problem (i.e. microbial keratitis).
- Known ocular pathologies (except refractive disorders).
- Coexistent ocular diseases impeding contact lens correction (i.e. glaucoma, previous ocular surgery).
- Corneal scarring.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Scleral contact lens without a passive artificial irisAlso: Control lens Design AParticipants wear a scleral contact lens without a passive artificial iris (Design A) on the dominant eye to perform the baseline visual performance assessment | Device | Healthy volunteers |
| Scleral contact lens with a passive artificial iris with low contrast (<1:5)Also: Test lens Design BParticipants wear a scleral contact lens with a low contrast (<1:5) passive artificial iris (Design B) on the dominant eye to perform the baseline visual performance assessment | Device | Healthy volunteers |
| Scleral contact lens with a passive artificial iris with high contrast (>1:5)Participants wear a scleral contact lens with a low contrast (<1:5) passive artificial iris (Design B) on the dominant eye to perform the baseline visual performance assessment | Device | Healthy volunteers |
| Tropicamide and phenylephrineAlso: Pupil dilation eye dropsParticipants receive pupil dilation eye drops on the dominant eye, after baseline measurement and before wearing the scleral contact lenses (Designs A, B and C) | Drug | Healthy volunteers |
Primary outcome
Visual acuity assessment and comparison between Designs A, B and C by means of logMAR or equivalent value
Time frame: 5 months from fitting session
Compare visual acuity values obtained with different designs
Contrast sensitivity assessment and comparison between Designs A, B and C by means of threshold percentage or equivalent value
Time frame: 5 months from fitting session
Compare contrast sensitivity values obtained with different designs
6 secondary outcomes
Device safety by comparing eventual adverse events with those found in scleral contact lenses
Time frame: 5 months from fitting session
Correct fitting
Time frame: 5 months from fitting session
Contact lens wear comfort, as assessed by subject data from questionnaires Rasch analyzed using a 4-Andrich ration scale model
Time frame: 5 months from fitting session
Visual acuity assessment and comparison between Designs B (low contrast) and C (high contrast) by means of logMAR or equivalent value
Time frame: 5 months from fitting session
Contrast sensitivity assessment and comparison between Designs B (low contrast) and C (high contrast) by means of threshold percentage or equivalent value
Time frame: 5 months from fitting session
Horizontal visual angle
Time frame: 5 months from fitting session
Results and safety
The study was stopped early (reason given: Several reasons: Financing ended before all study assessments were performed, covid-19 delayed design, production and shipment of IMD, experience gained during the study made it clear that lens design should be changed). Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 27 Apr 2022.
- Background: PubMed 22424803Garcia-Lazaro S, Ferrer-Blasco T, Radhakrishnan H, Cervino A, Charman WN, Montes-Mico R. Visual function through 4 contact lens-based pinhole systems for presbyopia. J Cataract Refract Surg. 2012 May;38(5):858-65. doi: 10.1016/j.jcrs.2011.11.042. Epub 2012 Mar 16.
- Background: PubMed 23079328Pepose JS. Small-aperture contact lenses for presbyopia. J Cataract Refract Surg. 2012 Nov;38(11):2060-1; author reply 2062-4. doi: 10.1016/j.jcrs.2012.08.041. No abstract available.
- Background: PubMed 27784070Xu R, Gil D, Dibas M, Hare W, Bradley A. The Effect of Light Level and Small Pupils on Presbyopic Reading Performance. Invest Ophthalmol Vis Sci. 2016 Oct 1;57(13):5656-5664. doi: 10.1167/iovs.16-20008.
- Background: PubMed 9544648Eyeson-Annan ML, Hirst LW, Battistutta D, Green A. Comparative pupil dilation using phenylephrine alone or in combination with tropicamide. Ophthalmology. 1998 Apr;105(4):726-32. doi: 10.1016/S0161-6420(98)94030-1.
- Background: PubMed 25190661Compan V, Oliveira C, Aguilella-Arzo M, Molla S, Peixoto-de-Matos SC, Gonzalez-Meijome JM. Oxygen diffusion and edema with modern scleral rigid gas permeable contact lenses. Invest Ophthalmol Vis Sci. 2014 Sep 4;55(10):6421-9. doi: 10.1167/iovs.14-14038.
- Background: PubMed 6592160Holden BA, Mertz GW. Critical oxygen levels to avoid corneal edema for daily and extended wear contact lenses. Invest Ophthalmol Vis Sci. 1984 Oct;25(10):1161-7.
- Individual participant dataSharing planned: No
Related trials for Low Vision
Active, not recruiting
Improving Visual Field Deficits With Noninvasive Brain Stimulation
Visual Field Defect, Peripheral, Stroke
RecruitingPhase 4
Ocular Assessments in Patients Treated With Tivdak® in Recurrent or Metastatic Cervical Cancer
Cervical Cancer
Recruiting
Brain Stimulation Effects on Orientation and Mobility Skills in Adults With Vision Impairment
Retinitis Pigmentosa (RP), Rod Cone Dystrophy
Not yet recruiting
NEURO-COGS: Neurometabolic Mechanisms of Cognitive Training in Schizophrenia
Schizophrenia, Schizoaffective Disorder
RecruitingPhase 3
A Study to Evaluate the Efficacy and Safety of Tabirafusp Tedromer Compared to Aflibercept in Participants With DME - ALTO
Diabetic Macular Edema (DME)
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Andres F Vasquez Quintero, Professor study chair
University Ghent
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Scleral contact lens without a passive artificial iris, Scleral contact lens with a passive artificial iris with low contrast (<1:5) and Scleral contact lens with a passive artificial iris with high contrast (>1:5) in people with Low Vision, run by University Ghent at 1 site in Belgium.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 7 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: stopped early, as of the sponsor's last update on 27 Apr 2022. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Belgium. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study was stopped early (reason given: Several reasons: Financing ended before all study assessments were performed, covid-19 delayed design, production and shipment of IMD, experience gained during the study made it clear that lens design should be changed). Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Visual acuity assessment and comparison between Designs A, B and C by means of logMAR or equivalent value (time frame: 5 months from fitting session). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT04040790, which also lists 6 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 27 Apr 2022.