AzTrials
AzTrials

Hand Injuries and DisordersNCT04174729

System for Quantifying the Functional Strength of the Grip and Pinch Movements

A study testing handgrip strength, Door handle device and Tap device in people with Hand Injuries and Disorders, run by University of Mogi das Cruzes at 1 site in Brazil.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

This study developed a system to quantify the functional strength of young adults without motor impairment during grip and pinch movement. Making it possible to know the accuracy of the value of these strength, the range of motion performed and whether the grip force was maintained throughout the range of motion. Read more about this study

Who is it for?
Ages 20 to 39 yearsHealthy volunteers can take part
Conditions the study is for
Hand Injuries and Disorders
What is being tested?
handgrip strength, Door handle device and Tap device
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
30 participants
Where
1 siteBrazil
Study dates
5 Aug 2019to 29 Oct 2019
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 20 to 39 years
  • All sexes
  • Healthy volunteers accepted
  • Adult

Who may be able to join

  • only right-handed individuals,
  • male and female,
  • have preserved cognitive functions,
  • absence of neurological disorder
  • who present minimum grip strength by the Jamar ® dynamometer, in the age group of 20-29 years men 45.08 ± 0.67 kg and women of 27.2 ± 0.46 kg, who present minimum grip strength by the dynamometer Jamar ®, aged 30 to 39 years old men 46.05 ± 0.47 kg and women 28.0 ± 0.39 kg, using the mean minus the standard deviation.

Who cannot join

  • Injury to upper limbs such as amputation, recent surgery (6 months), fractures, bruising, pain and musculoskeletal disorders.
  • Do not accept to participate in the survey.

Trial locations and contacts

1 site in 1 country.

Brazil1 site
  • Silvia Regina Matos da Silva Boschi

    Mogi das Cruzes, São Paulo, 08780-911

Other trials in Brazil

About this study

This study developed a system to quantify the functional strength of young adults without motor impairment during grip and pinch movement. Making it possible to know the accuracy of the value of these strength, the range of motion performed and whether the grip force was maintained throughout the range of motion. In addition to checking the functionality, reliability and reproducibility of the system.

Read the detailed description

Quantifying grip and grip movement is essential as it allows for a basis in upper limb functionality. However, when there is access, it causes changes in the hands and changes the motor in relation to the force and range of motion, or generates changes in activities of daily living. Thus, a system with 5 devices, where each one the devices were prints in three-dimensional, and instrumented with force sensor for static-dynamic force analysis e potentiometer for analysis range of motion, during the execution of movements cylindrical grip, spherical grip, hook grip, pulp-pulp pinch, and pulp- side pinch in different activities of daily living. Elaborated a data storage interface through MATLAB® software that allows recording the data of each device. For the system functionality tests, 30 volunteers were selected for both sexes, young adults between 20 and 39 years old, students of the Physiotherapy and Graduate courses of the University of Mogi das Cruzes. The tests are divided into two sessions and are repeated after 7 days of the first test

Being tested
handgrip strength, Door handle device, Tap device, Door pull handle, Linear Switch device
Medical subject headings
Hand Injuries, Disease

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • handgrip strengthDevice

    Also called Jamar dynamometer

    First, the hand measurements of each volunteer were evaluated, followed by the measurement of handgrip strength using the Jamar® dynamometer. And later the tests were performed using the system that contains the 5 devices to quantify the hand strength.

  • Door handle deviceDevice

    To evaluate the cylindrical grip movement, a door handle was used, which evaluated the full force in the range of motion.

  • Tap deviceDevice

    To evaluate the spherical grip movement, a tap was used, which evaluated the full force in the range of motion.

  • Door pull handleDevice

    To assess the hook grip movement, a door pull handle was used, which assessed the full force in the range of motion

  • Linear Switch deviceDevice

    To evaluate the pulp-pulp pinch movement, a switch was used, which evaluated the full force in the movement of the movement.

  • Door Key deviceDevice

    To assess the pulp-side pinch movement, a door key was used, which evaluated the full force in the range of motion.

Study groups in NCT04174729
Study groupRoleWhat they receive
Hand strengthExperimentalThe tests were performed in two sessions lasting 1 hour each. The volunteers used the devices: door handle, tap, door pull handle, switch and door key to quantify hand strength. The tests were performed in two sessions lasting 1 hour each. The volunteers used the devices: door handle, tap, door pull handle, switch and door key to quantify hand strength. In the first session, the volunteers performed the movements 3 times in each device of daily living activities with the right limb, with a 1-minute rest interval between the 3 measurements. The entire procedure performed in the session was repeated again after 30 minutes to verify the reliability and reproducibility of the Intra-evaluator test. The Inter-rater test was repeated after 7 days by the second rater to analyze reliability between the rater.
Receives: Device: handgrip strength; Device: Door handle device; Device: Tap device; Device: Door pull handle; Device: Linear Switch device; Device: Door Key device

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Strength device

    The strength of the cylindrical grip movement was quantified through the door handle device, the spherical grip strength through the tap device, the hook grip strength through the vertical door pull handle, the pulp-pulp pinch strength through the linear switch device and the pulp-side pinch strength through the key device. The test was quantified 3 times with a 1 minute interval between each test and the force throughout the range of motion.

    Unit of measure: newton (N).

    Measured: 15 minutes

Secondary outcomes (2)
  1. Range of motion in angle

    The test measured the range of motion of the door handle device, the tap device, door pull handle device and the door key device, 3 times with 1 minute interval for each test, in which all range of motion was measured from its start until its end. Unit of measure: Angle (º).

    Measured: 15 minutes

  2. Range of motion millimeter

    The test measured the range of motion in a linear switch device 3 times with a 1 minute interval for each test, in which all of the range of motion was measured from its start until its end. Unit measurement: millimeter (mm).

    Measured: 15 minutes

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted22 Nov 2019
  2. Study start5 Aug 2019
  3. Primary completion9 Sep 2019
  4. Study completion29 Oct 2019

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
30 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04174729
Sponsor's protocol ID
19020219.2.0000.5497
Status last verified
Nov 2019
First submitted
20 Nov 2019
Last updated
3 Dec 2019
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing handgrip strength, Door handle device and Tap device in people with Hand Injuries and Disorders, run by University of Mogi das Cruzes at 1 site in Brazil.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 3 Dec 2019. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Brazil. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Strength device (time frame: 15 minutes). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 3 Dec 2019.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in