Trial summary
The aim of this study is to compare the effectiveness of multiple modalities of cardiac resynchronisation therapy using high precision acute electrical and haemodynamic measurements.These modalities include biventricular pacing and conduction system pacing utilising His bundle and left bundle pacing. Read more about this study
- Who is it for?
- Ages 18 to 100 years
- Conditions the study is for
- Heart Failure, Left Ventricular Systolic Dysfunction, Left Bundle-Branch Block
- What is being tested?
- His-bundle pacing.
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 47 participants
- Where
- 1 siteUnited Kingdom
- Study dates
- 15 Oct 2019to 1 Dec 2022
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 100 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Patients referred for conventional CRT
- Severe heart failure (LVEF, a measure of heart pumping, < 35% - severe)
- Prolonged QRS duration (>120ms)
- Adults willing to take part (age > 18 years)
- Able to give consent
Who cannot join
- Unable to give consent
- Children (age < 18 years)
- Pregnant women
Trial locations and contacts
1 site in 1 country.
United Kingdom1 site
Hammersmith Hospital Imperial College NHS trust
London, W12 0HS
About this study
Official title: Evaluation of Mechanisms and Innovations in Cardiac Resynchronization Therapy
The aim of this study is to compare the effectiveness of multiple modalities of cardiac resynchronisation therapy using high precision acute electrical and haemodynamic measurements.These modalities include biventricular pacing and conduction system pacing utilising His bundle and left bundle pacing. Conduction system pacing is a more physiological form of pacing. The study hypothesises that this will produce more effective cardiac resynchronisation.
Read the detailed description
This is a single centre acute electrical/haemodynamic and observational study of a subgroup of patients with heart failure. A total of 60 will be recruited. The acute study involves within patient comparison of biventricular and conduction system pacing using detailed electrical mapping and high precision haemodynamic measurement protocol.
Participants will have permanent conduction system pacing if;
- Baseline left bundle branch block and QRS > 140ms or QRS >150ms and any QRS morphology AND
- Conduction system pacing is successful at reducing QRS duration by 20ms or more with satisfactory pacing parameters.
Participants who receive permanent conduction system pacing will have follow up at 6 weeks, 3 months, 6 months and 12 months. Non-invasive markers including mechanical activation pattern (echocardiography and cardiac MRI) and electrical activation pattern (ultra-high frequency electrocardiography) will be used to identify the characteristics of patients who benefit from conduction system pacing.
- Conditions
- Heart Failure, Left Ventricular Systolic Dysfunction, Left Bundle-Branch Block, Right Bundle-Branch Block, Non-Specific Intraventricular Conduction Defect
- Being tested
- His-bundle pacing.
- Keywords
- Cardiac resynchronization therapy, His bundle pacing, Haemodynamics, ECGI
- Medical subject headings
- Heart Failure, Ventricular Dysfunction, Left, Bundle-Branch Block
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
His-bundle pacing.Device
Also called Left bundle pacing, Biventricular pacing, Combined His-bundle and left ventricular epicardial pacing (HOT-CRT)
Cardiac resynchronisation therapy can be achieved using biventricular pacing involving placement of three leads into the right atrium, right ventricle and coronary sinus (epicardial left ventricle). Alternatively the third lead may be placed at the bundle of His or left ventricular septum to pace the left bundle directly.
| Study group | Role | What they receive |
|---|---|---|
| Heart failure and abnormal cardiac conduction | Experimental | Subjects will have an attempt at His-bundle pacing, left bundle pacing and biventricular pacing. Pacing at the His bundle and the left bundle will be attempted using a Medtronic SelectSecure™, Model 3830 lead. Delivery of the lead utilizes a deflectable sheath, the Medtronic SelectSite™, Model C304. Biventricular pacing will utilise a left ventricular lead placed in the coronary sinus using any of the 5 manufactures of CS leads Biotronik, Boston Scientific, Medtronic, Sorin, and St. Jude Medical or in participants receiving permanent conduction system pacing left ventricular pacing will be achieved using a Cordis ATW™ wire placed in the coronary sinus. Receives: Device: His-bundle pacing. |
What is being measured
The primary outcome is the main question the study is designed to answer.
Acute change is systolic blood pressure
Mean change in systolic blood pressure (mmHg) from atrial pacing to AV sequential CRT pacing (HBP, LBP, epiBVP and combined HPB with epiLVP) at optimal AV delay measured in mmHg.
Measured: 20 minutes
Acute electrical measurements
Mean change in left ventricular activation time (Milliseconds) (measured using ECGI) during AV sequential CRT pacing (HBP, LBP, epiBVP and combined HPB with epiLVP) at optimal AV delay measured in Milliseconds.
Measured: 20 minutes
Secondary outcomes (5)
Conduction system battery longevity
The measurements include battery longevity measured in months.
Measured: 6 weeks, 3 months, 6 months, 12 months.
Conduction system lead threshold
The measurements include lead threshold to achieved QRS narrowing measured in Volts at 0.5ms and 1ms.
Measured: 6 weeks, 3 months, 6 months, 12 months.
Heart failure symptoms
Heart failure symptoms of patients with permanent conduction system leads will be assessed at follow up at 3 month, 6 months and 12 months. The symptoms will be assessed using the Minnesota living with heart failure questionnaire score.
Measured: 6 months
Left ventricular ejection fraction
Patients with permanent conduction system leads will undergo a repeat echocardiography and measure their left ventricular ejection fraction.
Measured: 12 months
Cardiopulmonary exercise testing
Patients with permanent conduction system leads will undergo symptom assessment with a repeat cardio-pulmonary exercise test to measure MVO2 in litres/minute.
Measured: 6 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted9 Jan 2020
- Study start15 Oct 2019
- Primary completion1 Dec 2022
- Study completion1 Dec 2022
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (2)Papers the sponsor has linked to this study.
- Other trials for Heart FailureStudies of the same condition, open and under way.
- More trials run by Imperial College LondonThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Model description
- 60 patients with heart failure, severe left ventricular systolic dysfunction and cardiac conduction abnormality (QRS \> 120ms) will be recruited and undergo an attempt at His bundle, left bundle pacing and biventricular pacing. Patients will have acute haemodynamic and electrical measurements.
- Masking
- None (open label)
- Enrolment
- 47 participants (actual)
Sponsor and investigators
- Lead sponsor
- Imperial College London
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- Zachary Whinnett, BM BS B, Study chair, Imperial College London
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04221763
- Sponsor's protocol ID
- 18HH4801
- Other IDs
- FS/19/4/34013
- Acronym
- MIC
- Status last verified
- Mar 2023
- First submitted
- 4 Nov 2019
- Last updated
- 22 Mar 2023
- Results posted
- No
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- Yes: We plan to share the electrical data obtained from non-invasive electrical mapping with Medtronic (industry company)
Publications
Cleland JG, Abraham WT, Linde C, Gold MR, Young JB, Claude Daubert J, Sherfesee L, Wells GA, Tang AS. An individual patient meta-analysis of five randomized trials assessing the effects of cardiac resynchronization therapy on morbidity and mortality in patients with symptomatic heart failure. Eur Heart J. 2013 Dec;34(46):3547-56. doi: 10.1093/eurheartj/eht290. Epub 2013 Jul 29.
PubMed 23900696Vijayaraman P, Herweg B, Ellenbogen KA, Gajek J. His-Optimized Cardiac Resynchronization Therapy to Maximize Electrical Resynchronization: A Feasibility Study. Circ Arrhythm Electrophysiol. 2019 Feb;12(2):e006934. doi: 10.1161/CIRCEP.118.006934.
PubMed 30681348
Study at a glance
From the registry record, last updated by the sponsor on 22 Mar 2023. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Evaluation of Mechanisms and Innovations in Cardiac Resynchronization Therapy
- ClinicalTrials.gov ID
- NCT04221763
- Acronym / sponsor ID
- MIC / 18HH4801
- Conditions
- Heart Failure, Left Ventricular Systolic Dysfunction, Left Bundle-Branch Block, Right Bundle-Branch Block, Non-Specific Intraventricular Conduction Defect
- Keywords
- Cardiac resynchronization therapy, His bundle pacing, Haemodynamics, ECGI
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 47 participants (actual)
- Lead sponsor
- Imperial College LondonUniversity, hospital or other
- Study start
- 15 Oct 2019 (actual)
- Primary completion
- 1 Dec 2022 (actual)
- Study completion
- 1 Dec 2022 (actual)
- First posted
- 9 Jan 2020 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The aim of this study is to compare the effectiveness of multiple modalities of cardiac resynchronisation therapy using high precision acute electrical and haemodynamic measurements.These modalities include biventricular pacing and conduction system pacing utilising His bundle and left bundle pacing. Conduction system pacing is a more physiological form of pacing. The study hypothesises that this will produce more effective cardiac resynchronisation.
Detailed description
This is a single centre acute electrical/haemodynamic and observational study of a subgroup of patients with heart failure. A total of 60 will be recruited. The acute study involves within patient comparison of biventricular and conduction system pacing using detailed electrical mapping and high precision haemodynamic measurement protocol.
Participants will have permanent conduction system pacing if;
- Baseline left bundle branch block and QRS > 140ms or QRS >150ms and any QRS morphology AND
- Conduction system pacing is successful at reducing QRS duration by 20ms or more with satisfactory pacing parameters.
Participants who receive permanent conduction system pacing will have follow up at 6 weeks, 3 months, 6 months and 12 months. Non-invasive markers including mechanical activation pattern (echocardiography and cardiac MRI) and electrical activation pattern (ultra-high frequency electrocardiography) will be used to identify the characteristics of patients who benefit from conduction system pacing.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
- Model description
- 60 patients with heart failure, severe left ventricular systolic dysfunction and cardiac conduction abnormality (QRS > 120ms) will be recruited and undergo an attempt at His bundle, left bundle pacing and biventricular pacing. Patients will have acute haemodynamic and electrical measurements.
| Arm | Type | Receives |
|---|---|---|
| Heart failure and abnormal cardiac conduction | Experimental | Device: His-bundle pacing.Subjects will have an attempt at His-bundle pacing, left bundle pacing and biventricular pacing. Pacing at the His bundle and the left bundle will be attempted using a Medtronic SelectSecure™, Model 3830 lead. Delivery of the lead utilizes a deflectable sheath, the Medtronic SelectSite™, Model C304. Biventricular pacing will utilise a left ventricular lead placed in the coronary sinus using any of the 5 manufactures of CS leads Biotronik, Boston Scientific, Medtronic, Sorin, and St. Jude Medical or in participants receiving permanent conduction system pacing left ventricular pacing will be achieved using a Cordis ATW™ wire placed in the coronary sinus. |
Who may qualify
- Ages
- 18 to 100 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (5 listed)
- Patients referred for conventional CRT
- Severe heart failure (LVEF, a measure of heart pumping, < 35% - severe)
- Prolonged QRS duration (>120ms)
- Adults willing to take part (age > 18 years)
- Able to give consent
Key exclusion criteria (3 listed)
- Unable to give consent
- Children (age < 18 years)
- Pregnant women
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| His-bundle pacing.Also: Left bundle pacing, Biventricular pacing, Combined His-bundle and left ventricular epicardial pacing (HOT-CRT)Cardiac resynchronisation therapy can be achieved using biventricular pacing involving placement of three leads into the right atrium, right ventricle and coronary sinus (epicardial left ventricle). Alternatively the third lead may be placed at the bundle of His or left ventricular septum to pace the left bundle directly. | Device | Heart failure and abnormal cardiac conduction |
Primary outcome
Acute change is systolic blood pressure
Time frame: 20 minutes
Mean change in systolic blood pressure (mmHg) from atrial pacing to AV sequential CRT pacing (HBP, LBP, epiBVP and combined HPB with epiLVP) at optimal AV delay measured in mmHg.
Acute electrical measurements
Time frame: 20 minutes
Mean change in left ventricular activation time (Milliseconds) (measured using ECGI) during AV sequential CRT pacing (HBP, LBP, epiBVP and combined HPB with epiLVP) at optimal AV delay measured in Milliseconds.
5 secondary outcomes
Conduction system battery longevity
Time frame: 6 weeks, 3 months, 6 months, 12 months.
Conduction system lead threshold
Time frame: 6 weeks, 3 months, 6 months, 12 months.
Heart failure symptoms
Time frame: 6 months
Left ventricular ejection fraction
Time frame: 12 months
Cardiopulmonary exercise testing
Time frame: 6 months
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 22 Mar 2023.
- Background: PubMed 23900696Cleland JG, Abraham WT, Linde C, Gold MR, Young JB, Claude Daubert J, Sherfesee L, Wells GA, Tang AS. An individual patient meta-analysis of five randomized trials assessing the effects of cardiac resynchronization therapy on morbidity and mortality in patients with symptomatic heart failure. Eur Heart J. 2013 Dec;34(46):3547-56. doi: 10.1093/eurheartj/eht290. Epub 2013 Jul 29.
- Background: PubMed 30681348Vijayaraman P, Herweg B, Ellenbogen KA, Gajek J. His-Optimized Cardiac Resynchronization Therapy to Maximize Electrical Resynchronization: A Feasibility Study. Circ Arrhythm Electrophysiol. 2019 Feb;12(2):e006934. doi: 10.1161/CIRCEP.118.006934.
- Individual participant dataSharing planned: Yes. We plan to share the electrical data obtained from non-invasive electrical mapping with Medtronic (industry company)
Related trials for Heart Failure
Recruiting
Reducing Fluid Overload in Heart Failure Patients Using a Non-invasive, Renal Independent System
Chronic Heart Failure, CKD Stage 3
Not yet recruiting
SWitching to Appropriate Prescription in Cardiovascular-Kidney-Metabolic Syndrome
Cardiovascular-kidney-metabolic Syndrome, Diabete Type 2
Not yet recruiting
Notification Of High-Risk Veterans for Access to Heart Failure Prevention
Heart Failure
Enrolling by invitationObservational study
Multi-Scale Analysis of Phenotypes in Heart Failure (MAP-HEART)
Heart Failure
Recruiting
Achieving Optimal Medical Therapy Through Percutaneous Treatment of Secondary Mitral Regurgitation to Improve Outcome in Patients With HFrEF
Mitral Regurgitation Functional, Heart Failure With Reduced Ejection Fraction (HFrEF)
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Zachary Whinnett, BM BS B study chair
Imperial College London
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing His-bundle pacing. in people with Heart Failure and Left Ventricular Systolic Dysfunction, run by Imperial College London at 1 site in United Kingdom.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 5 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 22 Mar 2023. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United Kingdom. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Acute change is systolic blood pressure (time frame: 20 minutes). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT04221763, which also lists 2 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 22 Mar 2023.