AzTrials
AzTrials

AnesthesiaNCT04224259

Ultrasound Pre-scan to Reduce Needle Redirection During Right Jugular Vein Cannulation

A study testing Ultrasound pre-scan and Landmark guidance in people with Anesthesia, run by Taipei Medical University WanFang Hospital.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

This study aims to define a simple, safe, and effective ultrasound pre-scan technique for right internal jugular vein (RIJV) cannulation. After placing the patient properly, the operator puts a linear ultrasound probe at the mid neck in short-axis view. Read more about this study

Who is it for?
Ages 20 to 79 years
Conditions the study is for
Anesthesia
What is being tested?
Ultrasound pre-scan and Landmark guidance
Type of treatment
Surgery or procedure
Could I receive a placebo?
Yes, some participants may receive a placebo
How many people
80 participants
Where
No sites listed yet
Study dates
Feb 2020to Mar 2021
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 20 to 79 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Older than 20 years and younger than 80 years of age
  • American Society of Anesthesiologists Physical Status Classification I-III (no immediate life-threatening condition)
  • Scheduled for regular surgery
  • Receive general anesthesia with endotracheal tube intubation
  • In need of central venous catheter placement

Who cannot join

  • Body Mass Index > 35kg/m^2
  • Abnormal anatomy of the neck
  • Limited range of motion of the neck
  • The surgery does not allow right internal jugular vein cannulation or other contraindications for the procedure

Trial locations and contacts

No sites are listed yet.

Wei-Chen Chung, Dr. contact

+886965562781

elizabethp215@yahoo.com.tw

Jui-An Lin, Dr. contact

+886970746115

juian.lin@tmu.edu.tw

About this study

Official title: Utility of Vertical Puncture Technique Assisted by Ultrasound Pre-scan to Reduce Needle Redirection During Right Jugular Vein Cannulation

This study aims to define a simple, safe, and effective ultrasound pre-scan technique for right internal jugular vein (RIJV) cannulation. After placing the patient properly, the operator puts a linear ultrasound probe at the mid neck in short-axis view. With the IVJ in the center of the screen, the operator makes marks at both ends of the transducer (mark A and B), and then rotates the transducer 90 degrees counterclockwise. After finding IJV in long-axis view with transducer vertical to the ground, other two marks are made at both ends of the transducer (mark C and D). After proper preparation, the operator recognizes the cross point made by the imagined lines of marks AB and marks CD (point E). The needle is inserted vertically to the ground at point E.

Inclusion criteria are adult patients receiving general anesthesia in need of central venous cannulation.The primary endpoint is the number of needle redirection, and secondary endpoints include first attempt success rate, artery puncture, complication, number of wire attempt, number of skin insertion, venous access time, catheterization time, and malposition. The hypothesis is that this ultrasound pre-scan method would have a fewer number of needle redirection, a higher first-attempt success rate, as well as less complication, number of redirection.

Read the detailed description

Ultrasound-guided central venous cannulation has been widely used because of lower technical failure rate and complications, and faster access compared with landmark-guided cannulation. Real-time guidance is more complex to perform and time-consuming in comparison to pre-scan technique. Therefore, real-time guidance should be reserved to specific groups, such as infants, children, or those with anatomical abnormality. However, there's no widely accepted ultrasound pre-scan techniques yet. The aim of this study is to define a simple, safe, and effective ultrasound pre-scan technique for right internal jugular vein (RIJV) cannulation.

Patient position for RIJV cannulation was reviewed in detail. First, 15゚ Trendelenburg tilt significantly increases the diameter of right internal jugular vein. Second, extreme head rotation to the opposite side will increase the overlap percentage between IJV and common carotid artery (CCA), but neutral head position might make the procedure difficult. Neutral head position or small degree (≦15゚) of head rotation was recommended. Third, although shoulder roll is not recommended since it decreases the anterior-posterior diameter of RIJV, 4- to 5cm-high shoulder roll could be used to reduce the overlap if needed10. In conclusion, patients should be positioned by a 15゚ Trendelenburg tilt and 15゚ head rotation to the opposite side without a shoulder roll unless the IJV is anterior to CCA, which was termed as the rule of 15 by the research team.

After placing the patient properly, the operator puts a linear ultrasound probe at the mid neck in short-axis view. With IVJ in the center of the screen, marks at both ends of the transducer (mark A and B) are made. Then the operator rotates transducer 90 degrees counterclockwise. After finding IJV in long-axis view with transducer vertical to the ground, other two marks are made at both ends of the transducer (mark C and D), and transducer and jelly are removed. Then the operator sterilizes the performing field with chlorhexidine without removing the marks. After proper preparation and recognizing the cross point made by the imagined lines of marks AB and marks CD (point E), the operator inserts the needle vertically to the ground at point E.

The aim of this study is to compare the effectiveness and safety between ultrasound pre-scan technique and traditional landmark-guidance. Inclusion criteria are adult patients receiving general anesthesia in need of central venous cannulation. The primary endpoint is the number of needle redirection, and secondary endpoints include first attempt success rate, artery puncture, complication, number of wire attempt, number of skin insertion, venous access time, catheterization time, and malposition. The hypothesis is that the ultrasound pre-scan method would have a fewer number of needle redirection, a higher first-attempt success rate, as well as less complication, number of redirection.

Conditions
Anesthesia
Being tested
Ultrasound pre-scan, Landmark guidance
Keywords
Ultrasound, pre-scan, right internal jugular vein

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Ultrasound pre-scanProcedure or surgery

    Before cannulation, use ultrasound to mark the position of right internal jugular vein

  • Landmark guidanceProcedure or surgery

    The traditional landmark-guided technique for internal jugular vein cannulation, including recognizing the sternocleidomastoid muscle and palpating the carotid artery

Study groups in NCT04224259
Study groupRoleWhat they receive
ultrasound pre-scan groupExperimentalPerform ultrasound pre-scan before central venous cannulation
Receives: Procedure: Ultrasound pre-scan
landmark guidance groupSham comparatorUse the traditional landmark method to perform central venous cannulation
Receives: Procedure: Landmark guidance

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. number of needle redirection

    How many times of the needle being withdrawn and redirected before successfully access internal jugular vein

    Measured: During the cannulation procedure

Secondary outcomes (9)
  1. first attempt success rate

    successfully access the internal jugular vein at first attempt

    Measured: During the cannulation procedure

  2. artery puncture

    accidental artery puncture

    Measured: During the cannulation procedure

  3. number of wire attempt

    how many times of the wire attempts before successful wire insertion to internal jugular vein

    Measured: During the cannulation procedure

  4. number of skin insertion

    how many different skin insertion sites were tried before successfully access the internal jugular vein

    Measured: During the cannulation procedure

  5. venous access time

    How long does it take from the first skin insertion to success venous access

    Measured: During the cannulation procedure

  6. catheterization time

    How long does it take from the first skin insertion to successful catheter cannulation

    Measured: During the cannulation procedure

  7. malposition

    the catheter misplaced to wrong sites (e.g. artery, subcutaneous)

    Measured: During the cannulation procedure

  8. presence of hematoma

    a different and blinded investigator reviewed the post-procedure ultrasound image to determine whether there is hematoma after the procedure

    Measured: immediately at the end of procedure, evaluated by clinical signs and ultrasound image

  9. other complication

    Other complications related to the procedure, such as pneumothorax

    Measured: during the procedure, and 1 day after the procedure

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted13 Jan 2020
  2. Study startFeb 2020 (estimated)
  3. Primary completionDec 2020 (estimated)
  4. Study completionMar 2021 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Randomised
Intervention model
Parallel groups
Masking
Double blind
Who is masked
Participant, Outcomes assessor
Enrolment
80 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04224259
Sponsor's protocol ID
N201803005
Status last verified
Dec 2019
First submitted
28 Oct 2019
Last updated
13 Jan 2020
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No: There's no plan of sharing individual participant data currently

Publications

  • Schummer W, Koditz JA, Schelenz C, Reinhart K, Sakka SG. Pre-procedure ultrasound increases the success and safety of central venous catheterizationdagger. Br J Anaesth. 2014 Jul;113(1):122-9. doi: 10.1093/bja/aeu049. Epub 2014 Mar 18.

    PubMed 24648131

Questions about this trial

What is this clinical trial studying?

A study testing Ultrasound pre-scan and Landmark guidance in people with Anesthesia, run by Taipei Medical University WanFang Hospital.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 13 Jan 2020. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. Some participants in this study may receive a placebo. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Wei-Chen Chung, Dr. (+886965562781, elizabethp215@yahoo.com.tw), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

number of needle redirection (time frame: During the cannulation procedure). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04224259, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 13 Jan 2020.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in