AzTrials
AzTrials

Biliary StrictureBIBNCT04251013

Multicenter RCT for BIliary Brushing: RX Cytology, BOSTON vs. Infinity®, US Endoscopy

A study testing Biliary brushing with the RX Cytology brush, Boston Scientific and Biliary brushing with the Infinity® brush, US Endoscopy in people with Biliary Stricture and Jaundice, Obstructive, run by Société Française d'Endoscopie Digestive at 1 site in France.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The aim of this prospective national multicenter randomized study is to compare, during an ERCP for VBP stenosis, the sensitivity of two biliary brushes: the INFINITY® vs the RX Cytology Brush® The main objective is the comparison of the rates of positive diagnosis of biliary brushing in cases of adenocarcinoma… Read more about this study

Who is it for?
Ages 18 to 90 years
Conditions the study is for
Biliary Stricture, Jaundice, Obstructive
What is being tested?
Biliary brushing with the RX Cytology brush, Boston Scientific and Biliary brushing with the Infinity® brush, US Endoscopy
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
51 participants
Where
1 siteFrance
Study dates
1 Jul 2020to 1 Mar 2022
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 90 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patient admitted to one of the ERCP investigation centers with brushing and drainage for VBP stenosis (proximal or distal) during the study period
  • Patient whose age is greater than or equal to 18 years and less than 90 years
  • Patient ASA 1, ASA 2, ASA 3
  • Lack of participation in another clinical study
  • Signed informed consent

Who cannot join

  • Patients admitted for ERCP for jaundice by lithiasic obstruction
  • Patient under 18 or over 90
  • Patient ASA 4, ASA 5
  • Pregnant woman
  • Patient (s) with coagulation abnormalities preventing puncture: TP <50%, Platelets <50,000 / mm3, effective anti-coagulation in progress, clopidogrel in progress
  • Surgical setup (Billroth II, Roux en Y) preventing endoscopic access to the papilla
  • Patient unable to give personal consent
  • Lack of signed informed consent

Trial locations and contacts

1 site in 1 country.

France1 site
  • Clinique Paris Bercy

    Charenton-le-Pont, F-94220

Other trials in France

About this study

Official title: Multicenter RCT Comparing Two Brushes of Different Diameters for Biliary Stenosis: RX Cytology Brush, BOSTON vs. Infinity® Brush, US Endoscopy. BIB Study (BIliary Brushing)

The aim of this prospective national multicenter randomized study is to compare, during an ERCP for VBP stenosis, the sensitivity of two biliary brushes: the INFINITY® vs the RX Cytology Brush® The main objective is the comparison of the rates of positive diagnosis of biliary brushing in cases of adenocarcinoma stenosis The total number of subjects required: 50 (25 patients per group) Duration of the inclusion period: 2 years Duration of participation for each subject: from 7 days to 12 months (in case of negative initial withdrawal) Total duration of the study: 3 years

Read the detailed description

The aim of this study is to compare, during an ERCP for VBP stenosis, the sensitivity of two biliary brushes: the INFINITY® vs the RX Cytology Brush®

OBJECTIVES

  • Main objective: Comparison of the rates of positive diagnosis of biliary brushing in cases of adenocarcinoma stenosis
  • Secondary objective (s):
  • Comparison of the quantification of the cellular material obtained (acellular, weak, or abundant), and the presence of cellular cupboards unhooked by the brush
  • Comparison of the 2 brushes false negative rates, and negative predictive value for the diagnosis of adenocarcinoma
  • Evaluation of the variation in the profitability of brushing and other sampling techniques (intra-biliary biopsies, puncture, aspiration of bile) according to the presence of a tumor mass syndrome of more than 1 cm.
  • Evaluation of the variation in the profitability of brushing and other sampling techniques (intra-biliary biopsies, puncture, aspiration of bile) according to the site of the stenosis (distal vs proximal BPV: common bile duct or intrahepatic duct), with the cost effectiveness
  • Technical failure rate of brushing and other samples (intra-biliary biopsies, bile aspiration)

This study concerns adult subjects with stenosis of the main bile duct (common bile duct or common hepatic duct).

ENDOSCOPIC PROCEDURE

  • Deep catheterization of the biliary duct (whatever the access technique: by the papilla or by precut) and cross stenosis by the guide wire, then biliary dilation (6 to 8mm)
  • Randomization if the inclusion criteria are met
  • Biliary brushing successively with the 2 brushes in the order designated by randomization:
  • Performing a dozen back and forth movements in the stenosis
  • Aspiration, if possible of bile by the catheter of the brush for cytological analysis
  • The contents of the brush will be spread over 3 blades (numbered) then sectioned and placed in cytolit with the contents of the tubing of the brush flushed with a few cc of cytolit. Each brush in a numbered pot. Blades 1,2 and 3 +/- bile 1 joined to pot n ° 1; blades 4,5 and 6 +/- bile 2 joined to pot 2
  • In the event of technical failure (impossibility of accessing the stenosis with the first or second brush, impossibility of removing the brush), the patient will be considered to have failed for this brush (absence of pathological material brought back)

All possible sampling methods will also be taken to obtain the anatomopathological diagnosis: intra-biliary biopsies with adult or pediatric forceps, wire-guided or not, biopsy samples guided by choledochoscopy, puncture under endo-ultrasonography, bile aspiration after release of the biliary stent, according to the physician's habits.

EFFECTIVE The total number of subjects required: 50 (25 patients per group) Duration of the inclusion period: 2 years Duration of participation for each subject: from 7 days to 12 months (in case of negative initial withdrawal) Total duration of the study: 3 years

Being tested
Biliary brushing with the RX Cytology brush, Boston Scientific, Biliary brushing with the Infinity® brush, US Endoscopy
Medical subject headings
Jaundice, Obstructive

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Biliary brushing with the RX Cytology brush, Boston ScientificDevice

    Biliary brushing during ERCP:

    • Performing a dozen back and forth movements in the stenosis
    • Bile aspiration if possible, by the catheter of the brush for cytological analysis
    • The contents of the brush will be spread over 3 blades (numbered) then sectioned and placed in cytolit with the contents of the tubing of the brush flushed with a few cc of cytolit. Each brush in a numbered pot. Blades 1,2 and 3 +/- bile 1 joined to pot n ° 1; blades 4,5 and 6 +/- bile 2 joined to pot 2
    • In the event of technical failure (impossibility of accessing the stenosis with the first or second brush, impossibility of removing the brush), the patient will be considered to have failed for this brush (absence of pathological material brought back)
  • Biliary brushing with the Infinity® brush, US EndoscopyDevice

    Biliary brushing during ERCP:

    • Performing a dozen back and forth movements in the stenosis
    • Bile aspiration if possible, by the catheter of the brush for cytological analysis
    • The contents of the brush will be spread over 3 blades (numbered) then sectioned and placed in cytolit with the contents of the tubing of the brush flushed with a few cc of cytolit. Each brush in a numbered pot. Blades 1,2 and 3 +/- bile 1 joined to pot n ° 1; blades 4,5 and 6 +/- bile 2 joined to pot 2
    • In the event of technical failure (impossibility of accessing the stenosis with the first or second brush, impossibility of removing the brush), the patient will be considered to have failed for this brush (absence of pathological material brought back)
Study groups in NCT04251013
Study groupRoleWhat they receive
Group A: RX Cytology brush, Boston Scientific FIRSTActive comparatorA first biliary brushing will be carried out during ERCP using a standard brush RX Cytology Brush, Boston Scientific, then a second brushing will be carried out using a brush INFINITY®, US Endoscopy
Receives: Device: Biliary brushing with the RX Cytology brush, Boston Scientific; Device: Biliary brushing with the Infinity® brush, US Endoscopy
Group B: Infinity®, US Endoscopy FIRSTActive comparatorA first biliary brushing will be carried out during ERCP using an INFINITY® brush, US Endoscopy then a second brushing will be carried out using standard RX Cytology Brush, Boston Scientific
Receives: Device: Biliary brushing with the RX Cytology brush, Boston Scientific; Device: Biliary brushing with the Infinity® brush, US Endoscopy

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Sensibility for adenocarcinoma

    Rate of positive diagnosis of biliary brushing in case of cholangiocarcinoma stenosis

    Measured: 8 days to 1 year (if negative)

Secondary outcomes (7)
  1. Sample abundance

    Quantification of the cellular material obtained (acellular, weak, or abundant), presence of cellular cupboards unhooked by the brush or average number of cells per field

    Measured: 8 days

  2. False negative

    Negative brushing for a final diagnosis of cholangiocarcinoma

    Measured: 1 year

  3. Predictive Negative Value

    probability that patients with a negative brushing truly don't have cholangiocarcinoma

    Measured: 1 year

  4. Feasibility of the 2 brushes: Analog visual scale

    Analog visual scale: Feasibility scale (0 to 10, 0 for Extremely difficult to perform and 10 for very easy to perform)

    Measured: 1 day

  5. Feasibility of the intra-biliary biopsies: Analog visual scale

    Analog visual scale: Feasibility scale (0 to 10, 0 for Extremely difficult to perform and 10 for very easy to perform)

    Measured: 1 day

  6. Feasibility of bile aspiration: Analog visual scale

    Analog visual scale: Feasibility scale (0 to 10, 0 for Extremely difficult to perform and 10 for very easy to perform)

    Measured: 1 day

  7. Feasibility of stenosis puncture under ultrasonography: Analog visual scale

    Analog visual scale: Feasibility scale (0 to 10, 0 for Extremely difficult to perform and 10 for very easy to perform)

    Measured: 1 day

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted31 Jan 2020
  2. Study start1 Jul 2020
  3. Primary completion1 Mar 2022
  4. Study completion1 Mar 2022

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Randomised
Intervention model
Crossover
Model description
National prospective multicenter RCT
Masking
None (open label)
Enrolment
51 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04251013
Sponsor's protocol ID
BIB study
Acronym
BIB
Status last verified
Jun 2022
First submitted
25 Jan 2020
Last updated
21 Jun 2022
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Karsenti D, Privat J, Charissoux A, Perrot B, Leblanc S, Chaput U, Boytchev I, Levy J, Schaefer M, Bourgaux JF, Valats JC, Coron E, Moreno-Garcia M, Vanbiervliet G, Rahmi G, Robles EP, Wallenhorst T. Multicenter randomized trial comparing diagnostic sensitivity and cellular abundance with aggressive versus standard biliary brushing for bile duct stenosis without mass syndrome. Endoscopy. 2023 Sep;55(9):796-803. doi: 10.1055/a-2041-7687. Epub 2023 Feb 27.

    PubMed 36849106

Questions about this trial

What is this clinical trial studying?

A study testing Biliary brushing with the RX Cytology brush, Boston Scientific and Biliary brushing with the Infinity® brush, US Endoscopy in people with Biliary Stricture and Jaundice, Obstructive, run by Société Française d'Endoscopie Digestive at 1 site in France.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 21 Jun 2022. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in France. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Sensibility for adenocarcinoma (time frame: 8 days to 1 year (if negative)). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04251013, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 21 Jun 2022.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in