AzTrials
AzTrials

Capsule EndoscopyNCT04329468

Detachable String MCE for Upper Gastrointestinal Tract and Small Bowel

A study testing DS-MCE in people with Capsule Endoscopy, run by Zhuan Liao at 1 site in China.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

This study aims to evaluate the feasibility and safety of DS-MCE with a novel way for complete examination in UGI tract and small bowel, compared with EGD. Read more about this study

Who is it for?
Ages 18 to 80 yearsHealthy volunteers can take part
Conditions the study is for
Capsule Endoscopy
What is being tested?
DS-MCE
Could I receive a placebo?
No, everyone receives an active treatment
How many people
25 participants
Where
1 siteChina
Study dates
10 Mar 2020to 20 Sep 2020
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 80 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Adult patients aged 18 to 80
  • With or without gastrointestinal complaints
  • Scheduled to undergo a capsule endoscopy for both stomach and small bowel
  • Signed the informed consents before joining this study

Who cannot join

  • Pacemakers or electromedical devices implanted which are incompatible with magnetic field;
  • Suspected or known gastrointestinal stenosis, obstruction or other known risk factors for capsule retention;
  • Scheduled magnetic resonance imaging examination before excretion of capsule;
  • Pregnancy or suspected pregnancy;
  • Any contraindications about EGD.
  • Other circumstances that doctors consider inappropriate for the study.

Trial locations and contacts

1 site in 1 country.

China1 site, 1 recruiting
  • Changhai Hospital

    Shanghai, 200433

    Zhuan Liao, 86-21-31161004, liaozhuan@smmu.edu.cn

    Bin Jiang

    Recruiting

Other trials in China

About this study

Official title: Detachable String Magnetically Controlled Capsule Endoscopy for Complete Examination of Upper Gastrointestinal Tract and Small Bowel

This study aims to evaluate the feasibility and safety of DS-MCE with a novel way for complete examination in UGI tract and small bowel, compared with EGD.

Read the detailed description

Magnetically controlled capsule endoscopy (MCE) has been widely used in clinical practice for upper gastrointestinal (UGI) tract and Small Bowel. However, the complete visualization of UGI tract still present challenges due to rapid transit through esophagus and duodenum, although technical improvements of MCE are helpful.

Detachable String MCE (DS-MCE) can control the movement of MCE through the string and MCE can start next examination after string detachment, which was proved to be an effective and safe method for complete viewing of the esophagus and stomach. In order to improve the duodenum visualization, endoscopist separate MCE from the string after finishing UGI examination so that can inspect the esophagus, stomach and duodenum under the string and magnetic field control.

This is a prospective, single-centered, self-controlled pilot study. Subjects with or without digestive symptoms receiving UGI endoscopy will be enrolled to take DS-MCE and conventional esophagogastroduodenoscopy (EGD) within 48h successively.

Being tested
DS-MCE
Keywords
DS-MCE, Z-line, Duodenal papilla, Completion rate

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • DS-MCEDevice

    The subjects swallowed the MCE to investigate the esophagus repeatedly by pulling up or down the string. After completion of the esophageal examination, MCE reached the stomach and was lifted away from the posterior wall, rotated if necessary and advanced to the fundus and cardiac regions, and then to the gastric body, angulus, antrum and pylorus. After finishing the stomach examination, the capsule would enter the duodenum due to peristalsis when the pylorus opened. Then DS-MCE tried to inspect the duodenum repeatedly under the string and magnetic field control, including view of major papilla in the descending part of duodenum and retrograde view of pylorus in duodenal bulb with a "360-degree automatic scanning" mode. After completion of the duodenum examination, the capsule started to view the small bowel.

Study groups in NCT04329468
Study groupRoleWhat they receive
DS-MCE examinationExperimentalSubjects with or without digestive symptoms will be enrolled to take DS-MCE and conventional esophagogastroduodenoscopy (EGD) within 48h successively.
Receives: Device: DS-MCE

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Success rate of UGI and small-bowel examination

    The feasibility of DS-MCE examination with a novel way is evaluated by the technical success rate, a composite outcome including the successful separation of the string and MCE, repeat viewing of esophagus, stomach and duodenum, and complete small-bowel examination.

    Measured: up to 2 weeks

Secondary outcomes (11)
  1. Diagnostic accuracy

    The diagnostic accordance rate, sensitivity and specificity of lesions detected by DS-MCE compared with EGD.

    Measured: up to 2 weeks

  2. Safety of DS-MCE procedure: presence of any adverse events during DS-MCE procedure will be recorded

    The presence of any adverse events during DS-MCE procedure will be recorded.

    Measured: up to 2 weeks

  3. Detection rate of Z-line, duodenal papilla and pyloric retrograde view

    The detection means that at least one image of anatomical structure was obtained.

    Measured: up to 2 weeks

  4. Circumferential visualization of the Z-line and duodenal papilla

    It is defined by quadrants as follows: less than 2 quadrants (< 50%) observed; at least 2 quadrants (50%-75%) observed; at least 3 quadrants (>75%) observed; and entire structure (100%) observed.

    Measured: up to 2 weeks

  5. Cleansing level of Z-line and duodenal papilla area

    The effect of bubbles/saliva on the appearance of the Z line or duodenal papilla area was both scored as follows: 0=no interference by bubbles/saliva;1=minor interference of bubbles/saliva; 2=major interference of bubbles/saliva.

    Measured: up to 2 weeks

  6. Visualization level of stomach

    Visualization level of gastric primary anatomic landmarks: cardia, fundus, body, angulus, antrum and pylorus. (good, >75% of mucosa was observed; moderate, 50% to 75% was observed; poor, <50% of the gastric mucosa was observed)

    Measured: up to 2 weeks

  7. Examination time of esophagus, stomach, duodenum and small bowel

    Record the time taken to finish examination in different digestive part.

    Measured: up to 2 weeks

  8. Pyloric transit time

    Record the time from completion of the gastric examination to the capsule entering the duodenum.

    Measured: up to 2 weeks

  9. Discomfort scores associated with DS-MCE

    Discomfort caused by the string, swallowing the DS-MCE, pulling the capsule up or down, and pulling the string out were on a scale from 0 to 3 (0=none;1=mild/minimal; 2=moderate; and 3=severe/very difficult) according to the Ramirez system. Overall discomfort was scored on a scale of 0 to 10 (0=no discomfort; 10=the overall discomfort of EGD) according to our previous system.

    Measured: up to 2 weeks

  10. Image quality scores

    Assess Image quality grade ranged from 1 to 10 (1, the worst quality; 10, the quality of the best image captured by EGD).

    Measured: up to 2 weeks

  11. Detection rate of lesions

    The detection rate of lesions in different digestive part (esophagus, stomach, duodenum, jejunoileum) found by MCE.

    Measured: up to 2 weeks

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted1 Apr 2020
  2. Study start10 Mar 2020
  3. Primary completion20 Aug 2020 (estimated)
  4. Study completion20 Sep 2020 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
25 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04329468
Sponsor's protocol ID
DS-MCE-UGI and SB
Status last verified
Mar 2020
First submitted
27 Mar 2020
Last updated
21 Jul 2020
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Chen YZ, Pan J, Luo YY, Jiang X, Zou WB, Qian YY, Zhou W, Liu X, Li ZS, Liao Z. Detachable string magnetically controlled capsule endoscopy for complete viewing of the esophagus and stomach. Endoscopy. 2019 Apr;51(4):360-364. doi: 10.1055/a-0856-6845. Epub 2019 Mar 1.

    PubMed 30822803
  • Jiang B, Qian YY, Wang YC, Pan J, Jiang X, Zhu JH, Qiu XO, Zhou W, Li ZS, Liao Z. A novel capsule endoscopy for upper and mid-GI tract: the UMGI capsule. BMC Gastroenterol. 2023 Mar 16;23(1):76. doi: 10.1186/s12876-023-02696-5.

    PubMed 36927462

Questions about this trial

What is this clinical trial studying?

A study testing DS-MCE in people with Capsule Endoscopy, run by Zhuan Liao at 1 site in China.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 21 Jul 2020. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in China. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Bin Jiang (15021569528 ext. 15021569528, jarz1995@163.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Success rate of UGI and small-bowel examination (time frame: up to 2 weeks). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04329468, which also lists 2 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 21 Jul 2020.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in