Crohn Disease (CD)SCAINCT07111715
Comparison Between Artificial Intelligence and Standard Reading to Investigate Suspected Crohn Disease: the SCAI STUDY
An observational study of Crohn Disease (CD), run by Fondazione Poliambulanza Istituto Ospedaliero at 1 site in Italy.
Trial summary
The diagnosis of Crohn's Disease (CD) is based on a combination of clinical, biochemical (serological and fecal), endoscopic, radiological, and histological investigations. In the absence of obstructive symptoms or known stenosis, European guidelines recommend to investigate the small intestine using Video Capsule… Read more about this study
- Who is it for?
- Ages 18 to 75 years
- Conditions the study is for
- Crohn Disease (CD)
- What is being tested?
- Small bowel Video Capsule Endoscopy (VCE) using an Capsule System equipped with a Deep Neural Network based system called SmartScan (SC),
- Type of treatment
- Pill or oral medicine, Medical device
- How many people
- 180 participants
- Where
- 1 siteItaly
- Study dates
- 21 Jul 2025to 31 Dec 2028
- Phase
- Observational
- Are there results?
- Not yet: the study is under way
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 75 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Study population: Eligible patients for the study are those with clinical symptoms and laboratory results suggestive of CD who have previously undergone an ileocolonoscopy which excluded other organic pathology and/or resulted inconclusive for CD (aspecific terminal ileitis).
Who may be able to join
- Age >= 18 and <= 75 years
- Clinical suspicion of Crohn's Disease (CD) with/without occlusive symptoms
- Ileocolonoscopy: negative examination, aspecific inflammatory findings
- Signed informed consent form
Who cannot join
- Known diagnosis of CD
- Endoscopic diagnosis of active diverticular disease, colorectal cancer, ulcerative colitis, or infectious colitis, microscopic colitis
- Positive stool tests for pathogenic bacteria, Yersinia enterocolitica, parasites, C. difficile infection, fecal antigen for Giardia lamblia within 6 months before VCE
- Known intestinal obstruction or unconfirmed small bowel patency
- Any use of NSAIDs in the 4 weeks before ileocolonoscopy and before VCE
- Known gastrointestinal motility disorder
Show all 16Show fewer
- Known or suspected delayed gastric emptying
- Swallowing disorders
- Allergy or other contraindications or intolerance to the medications/devices used in the study
- Endoscopic placement of the capsule
- Any condition that prevents adherence to the study
- Pregnancy
- Participation in another clinical trial involving experimental drugs or devices
- Concomitant life-threatening condition
- Chronic kidney disease (eGFR<30mL/min/1.73 m2)
- Inability to sign the informed consent
Trial locations and contacts
1 site in 1 country. Contact the study team or a site near you to ask about taking part.
Italy1 site, 1 recruiting
- Recruiting
Fondazione Poliambulanza Istituto Ospedaliero
Brescia, Brescia, 25124
Stefania Piccirelli, MD, +390303518364, stefania.piccirelli@poliambulanza.it
About this study
Official title: Comparison Between Artificial Intelligence Assisted Capsule Endoscopy and Standard Reading to Investigate Suspected Crohn Disease: the SCAI STUDY
The diagnosis of Crohn's Disease (CD) is based on a combination of clinical, biochemical (serological and fecal), endoscopic, radiological, and histological investigations. In the absence of obstructive symptoms or known stenosis, European guidelines recommend to investigate the small intestine using Video Capsule Endoscopy (VCE) if ileocolonoscopy is not decisive. To reduce the reading time of VCE and increase the number of identified lesions during the examination, various artificial intelligence software/tools have been developed in recent decades. This study aims to be the first prospective multicentric real-life trial to evaluate AI-assisted VCE using SmartScan in identifying typical mucosal abnormalities of the small intestine in patients with suspected CD and its ability to reduce reading time while maintaining the same diagnostic yield and diagnostic accuracy of standard reading. The objective of the study is to evaluate the role of AI-assisted VCE using the OMOM SmartScan in detecting typical small bowel inflammatory lesions (i.e. erosions and ulcers) in patients with suspected CD, and comparing AI with standard reading.
Read the detailed description
SCREENING Patients with signs and symptoms of suspected CD AND negative/inconclusive ileocolonoscopy will be enrolled. Inconclusive ileocolonoscopy will be defined as the presence of aspecific inflammatory mucosal alterations in the ileum or colon, that do not allow a final diagnosis of CD. At the Screening Visit, active or recent gastrointestinal infection will be ruled out. Patients who will present with sub-occlusive symptoms will undergo a patency capsule to exclude the presence of a stenosis. Only patients with a prompt patency transit (expulsion within 30-33 hours of the intact patency capsule or its absence on abdominal X-ray) will be enrolled.
Signs and symptoms of suspected CD will be defined according to the ECCO Guidelines and ICCE criteria. An ad-hoc protocol defined by the authors will be applied to define the patient with suspicion of CD, stratifying all factors as major or minor criteria: the presence of at least two major criteria or the combination of one major criteria with three minor criteria will be necessary for patient enrolment. Other clinical, laboratory and radiological data will be collected (i.e. Thrombocyte, leukocytes, ESR, Vitamin D).
Before the ingestion of the capsule, patients reported outcomes (PRO) measures will be collected to investigate how patients' symptoms impair their physical and mental health (anxiety, depression), interfere with daily activities (work, personal care) and are responsible for chronic fatigue and tiredness, or loss of energy. The aforementioned questionnaires are FACIT-F (https://www.facit.org/measures/facit-fatigue), SF 36 (22), and EQ-5D-5L (23).
VCE PROTOCOL: Small bowel VCE will be performed using the OMOM Capsule System (Chongqing Jinshan Science \& Technology (Group) Co), equipped with a DNN based system called SmartScan (SC), which is able to automatically select suspected lesions thus creating a very short video constituted only by selected images. The SC100 system tested in this study consists of:
- Ingestible microcamera SC1 OMOM HD: the capsule is 25.4 x 11.4 mm in size, with a weight of 3.0 grams. It is embedded with a single camera with a 172° field of view; sampling rate varies between 4 and 35 frames per second, and the image resolution is 512 x 512 pixels. The depth of field is optimized between 0 and 50 mm. The Truecolor 24-bit model allows for high colour depth, displaying up to 16 million colours per pixel.
- Recorder and SC-RD1 belt: antennas receive data from the OMOM video capsule
- Vue Smart Work Station: SmartView reading software equipped with the CNN model. The CNN model analyses raw data during the download phase from the recorder and during video review. It supports the operator in reviewing and reporting through three functionalities:
- SmartScan: Based on an AI algorithm developed and validated for reviewing capsule videos of the stomach and small intestine, it eliminates redundant images and identifies 16 different types of abnormalities found in the images.
- SmartView: Allows the operator to quickly "navigate" through the entire video, showing only the images selected by SmartScan and highlighting the selected video portions on the timeline that can be viewed separately from the rest of the footage.
- SmartFinding: Displays only the images selected by the operator, providing a description and characterization of the detected abnormalities.
VCE will be performed at each centre according to local regulations and requirements, and the study protocol will address the bowel preparation regimen as well as the reading methods and post-procedural analysis for each patient.
PRE-PROCEDURAL PATIENT MANAGEMENT: To achieve homogeneous results, a standard bowel preparation regimen will be adopted, involving the intake of 1 L of Polyethylene glycol + ascorbic acid (Moviprep) in a single-dose manner after the VCE ingestion, as recommended by Xavier et Al. and Estevinho et al.
POST-PROCEDURAL MANAGEMENT: Patient follow-up will occur according to routine clinical practice, collecting any cases of retention or adverse events. Patients undergoing VCE will be instructed to check for the expulsion of the capsule and to report any relevant symptom that may suggest potential capsule retention. Patients who do not notice the expulsion of the capsule within 2 weeks of ingestion will undergo an abdominal X-ray to exclude capsule retention. Clinical and laboratory data of all patients enrolled will be collected at follow-up visits (at 6 and 12 months).
VIDEO CAPSULE READING: At the site of patient's enrolment, investigators (with experience of > 100 capsules read) will perform VCE by evaluating the video in standard mode according to the recommendations of the European Society of Gastrointestinal Endoscopy, at 10 frames per second in the small intestine, and 20 frames per second in the esophagus, stomach, and colon. The cleanliness level will be assessed as adequate (excellent/good) or inadequate (fair/poor) according to the qualitative scale of Brotz. Inflammatory lesions will be described using the Nomenclature and semantic descriptions defined by Leenhardt et al. in the International Delphi consensus, specifically modified for this study to ensure inter-observer agreement in the description of lesions. Lesions will be reported specifying their time of appearance (h: min: s, timing of single frames. At the end of the reading, readers will also calculate the Lewis score for each video. A score between ≥ 135 and < 790 indicates mild inflammation; and a score of ≥ 790 signifies moderate-to-severe inflammation.
Investigators at the enrolment centre will anonymize the video which will be randomly reallocated to another centre for the second blind reading assisted by AI (i.e., the readers performing the capsule reading in AI mode will not be aware of the results of the first reading in standard mode).
An external expert reader (read more than 500 capsules) will review all the VCE, blind to the source of the videos.
- Conditions
- Crohn Disease (CD)
- Being tested
- Small bowel Video Capsule Endoscopy (VCE) using an Capsule System equipped with a Deep Neural Network based system called SmartScan (SC),
- Keywords
- Crohn Disease (CD), Artificial Intelligence, Video Capsule Endoscopy (VCE)
- Medical subject headings
- Crohn Disease
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Small bowel Video Capsule Endoscopy (VCE) using an Capsule System equipped with a Deep Neural Network based system called SmartScan (SC),Device
Also called Video Capsule Endoscopy (VCE), DNN SmartScan system
Small bowel Video Capsule Endoscopy (VCE) will be performed using the an Capsule System equipped with a Deep Neural Network based system called SmartScan (SC), which is able to automatically select suspected lesions thus creating a very short video constituted only by selected images.
| Study group | Role | What they receive |
|---|---|---|
| Suspected Crohn's Disease | Eligible patients for the study are those with clinical symptoms and laboratory results suggestive of CD who have previously undergone an ileocolonoscopy which excluded other organic pathology and/or resulted inconclusive for CD (aspecific terminal ileitis). Receives: Device: Small bowel Video Capsule Endoscopy (VCE) using an Capsule System equipped with a Deep Neural Network based system called SmartScan (SC), |
What is being measured
The primary outcome is the main question the study is designed to answer.
Diagnostic yield (DY)
Non-inferiority of AI-assisted reading (AIR) compared to standard reading (SR) in detecting (diagnostic yield - DY) typical lesions of suspected CD (erosions and/or ulcers and/or stenosis).
Measured: through study completion, an average of 1 year
Secondary outcomes (1)
VCE reading time
Small bowel reading time of video capsule endoscopy in two setting: Artificial Intelligence Reading and in Standard Reading
Measured: through study completion, an average of 1 year
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted8 Aug 2025
- Study start21 Jul 2025
- Primary completion31 Dec 2027 (estimated)
- Study completion31 Dec 2028 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Crohn Disease (CD)Studies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Cohort
- Time perspective
- Prospective
- Enrolment
- 180 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Fondazione Poliambulanza Istituto Ospedaliero
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Stefania Piccirelli, Fondazione Poliambulanza Istituto Ospedaliero
- Investigators
- Cristiano Spada, Prof, Study director, Fondazione Poliambulanza, Policlinico A GemelliPaola Cesaro, PhD, Study director, Fondazione PoliambulanzaStefania Piccirelli, MD, Principal investigator, Fondazione Poliambulanza
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT07111715
- Sponsor's protocol ID
- SCAI_Prot0026575/25
- Other IDs
- Local Ethical Committee
- Acronym
- SCAI
- Status last verified
- Sep 2026
- First submitted
- 4 Jul 2025
- Last updated
- 2 Sep 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Yes
Study at a glance
From the registry record, last updated by the sponsor on 2 Sep 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Comparison Between Artificial Intelligence Assisted Capsule Endoscopy and Standard Reading to Investigate Suspected Crohn Disease: the SCAI STUDY
- ClinicalTrials.gov ID
- NCT07111715
- Acronym / sponsor ID
- SCAI / SCAI_Prot0026575/25
- Conditions
- Crohn Disease (CD)
- Keywords
- Crohn Disease (CD), Artificial Intelligence, Video Capsule Endoscopy (VCE)
- Study type
- Observational
- Recruitment status
- Recruiting
- Enrolment
- 180 participants (estimated)
- Lead sponsor
- Fondazione Poliambulanza Istituto OspedalieroUniversity, hospital or other
- Study start
- 21 Jul 2025 (actual)
- Primary completion
- 31 Dec 2027 (estimated)
- Study completion
- 31 Dec 2028 (estimated)
- First posted
- 8 Aug 2025 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The diagnosis of Crohn's Disease (CD) is based on a combination of clinical, biochemical (serological and fecal), endoscopic, radiological, and histological investigations. In the absence of obstructive symptoms or known stenosis, European guidelines recommend to investigate the small intestine using Video Capsule Endoscopy (VCE) if ileocolonoscopy is not decisive. To reduce the reading time of VCE and increase the number of identified lesions during the examination, various artificial intelligence software/tools have been developed in recent decades. This study aims to be the first prospective multicentric real-life trial to evaluate AI-assisted VCE using SmartScan in identifying typical mucosal abnormalities of the small intestine in patients with suspected CD and its ability to reduce reading time while maintaining the same diagnostic yield and diagnostic accuracy of standard reading. The objective of the study is to evaluate the role of AI-assisted VCE using the OMOM SmartScan in detecting typical small bowel inflammatory lesions (i.e. erosions and ulcers) in patients with suspected CD, and comparing AI with standard reading.
Detailed description
SCREENING Patients with signs and symptoms of suspected CD AND negative/inconclusive ileocolonoscopy will be enrolled. Inconclusive ileocolonoscopy will be defined as the presence of aspecific inflammatory mucosal alterations in the ileum or colon, that do not allow a final diagnosis of CD. At the Screening Visit, active or recent gastrointestinal infection will be ruled out. Patients who will present with sub-occlusive symptoms will undergo a patency capsule to exclude the presence of a stenosis. Only patients with a prompt patency transit (expulsion within 30-33 hours of the intact patency capsule or its absence on abdominal X-ray) will be enrolled.
Signs and symptoms of suspected CD will be defined according to the ECCO Guidelines and ICCE criteria. An ad-hoc protocol defined by the authors will be applied to define the patient with suspicion of CD, stratifying all factors as major or minor criteria: the presence of at least two major criteria or the combination of one major criteria with three minor criteria will be necessary for patient enrolment. Other clinical, laboratory and radiological data will be collected (i.e. Thrombocyte, leukocytes, ESR, Vitamin D).
Before the ingestion of the capsule, patients reported outcomes (PRO) measures will be collected to investigate how patients' symptoms impair their physical and mental health (anxiety, depression), interfere with daily activities (work, personal care) and are responsible for chronic fatigue and tiredness, or loss of energy. The aforementioned questionnaires are FACIT-F (https://www.facit.org/measures/facit-fatigue), SF 36 (22), and EQ-5D-5L (23).
VCE PROTOCOL: Small bowel VCE will be performed using the OMOM Capsule System (Chongqing Jinshan Science \& Technology (Group) Co), equipped with a DNN based system called SmartScan (SC), which is able to automatically select suspected lesions thus creating a very short video constituted only by selected images. The SC100 system tested in this study consists of:
- Ingestible microcamera SC1 OMOM HD: the capsule is 25.4 x 11.4 mm in size, with a weight of 3.0 grams. It is embedded with a single camera with a 172° field of view; sampling rate varies between 4 and 35 frames per second, and the image resolution is 512 x 512 pixels. The depth of field is optimized between 0 and 50 mm. The Truecolor 24-bit model allows for high colour depth, displaying up to 16 million colours per pixel.
- Recorder and SC-RD1 belt: antennas receive data from the OMOM video capsule
- Vue Smart Work Station: SmartView reading software equipped with the CNN model. The CNN model analyses raw data during the download phase from the recorder and during video review. It supports the operator in reviewing and reporting through three functionalities:
- SmartScan: Based on an AI algorithm developed and validated for reviewing capsule videos of the stomach and small intestine, it eliminates redundant images and identifies 16 different types of abnormalities found in the images.
- SmartView: Allows the operator to quickly "navigate" through the entire video, showing only the images selected by SmartScan and highlighting the selected video portions on the timeline that can be viewed separately from the rest of the footage.
- SmartFinding: Displays only the images selected by the operator, providing a description and characterization of the detected abnormalities.
VCE will be performed at each centre according to local regulations and requirements, and the study protocol will address the bowel preparation regimen as well as the reading methods and post-procedural analysis for each patient.
PRE-PROCEDURAL PATIENT MANAGEMENT: To achieve homogeneous results, a standard bowel preparation regimen will be adopted, involving the intake of 1 L of Polyethylene glycol + ascorbic acid (Moviprep) in a single-dose manner after the VCE ingestion, as recommended by Xavier et Al. and Estevinho et al.
POST-PROCEDURAL MANAGEMENT: Patient follow-up will occur according to routine clinical practice, collecting any cases of retention or adverse events. Patients undergoing VCE will be instructed to check for the expulsion of the capsule and to report any relevant symptom that may suggest potential capsule retention. Patients who do not notice the expulsion of the capsule within 2 weeks of ingestion will undergo an abdominal X-ray to exclude capsule retention. Clinical and laboratory data of all patients enrolled will be collected at follow-up visits (at 6 and 12 months).
VIDEO CAPSULE READING: At the site of patient's enrolment, investigators (with experience of > 100 capsules read) will perform VCE by evaluating the video in standard mode according to the recommendations of the European Society of Gastrointestinal Endoscopy, at 10 frames per second in the small intestine, and 20 frames per second in the esophagus, stomach, and colon. The cleanliness level will be assessed as adequate (excellent/good) or inadequate (fair/poor) according to the qualitative scale of Brotz. Inflammatory lesions will be described using the Nomenclature and semantic descriptions defined by Leenhardt et al. in the International Delphi consensus, specifically modified for this study to ensure inter-observer agreement in the description of lesions. Lesions will be reported specifying their time of appearance (h: min: s, timing of single frames. At the end of the reading, readers will also calculate the Lewis score for each video. A score between ≥ 135 and < 790 indicates mild inflammation; and a score of ≥ 790 signifies moderate-to-severe inflammation.
Investigators at the enrolment centre will anonymize the video which will be randomly reallocated to another centre for the second blind reading assisted by AI (i.e., the readers performing the capsule reading in AI mode will not be aware of the results of the first reading in standard mode).
An external expert reader (read more than 500 capsules) will review all the VCE, blind to the source of the videos.
Study design
- Observational model
- Cohort
- Time perspective
- Prospective
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Suspected Crohn's Disease | – | Device: Small bowel Video Capsule Endoscopy (VCE) using an Capsule System equipped with a Deep Neural Network based system called SmartScan (SC),Eligible patients for the study are those with clinical symptoms and laboratory results suggestive of CD who have previously undergone an ileocolonoscopy which excluded other organic pathology and/or resulted inconclusive for CD (aspecific terminal ileitis). |
Who may qualify
- Ages
- 18 to 75 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
- Study population
- Eligible patients for the study are those with clinical symptoms and laboratory results suggestive of CD who have previously undergone an ileocolonoscopy which excluded other organic pathology and/or resulted inconclusive for CD (aspecific terminal ileitis).
Key inclusion criteria (4 listed)
- Age >= 18 and <= 75 years
- Clinical suspicion of Crohn's Disease (CD) with/without occlusive symptoms
- Ileocolonoscopy: negative examination, aspecific inflammatory findings
- Signed informed consent form
Key exclusion criteria (16 listed)
- Known diagnosis of CD
- Endoscopic diagnosis of active diverticular disease, colorectal cancer, ulcerative colitis, or infectious colitis, microscopic colitis
- Positive stool tests for pathogenic bacteria, Yersinia enterocolitica, parasites, C. difficile infection, fecal antigen for Giardia lamblia within 6 months before VCE
- Known intestinal obstruction or unconfirmed small bowel patency
- Any use of NSAIDs in the 4 weeks before ileocolonoscopy and before VCE
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Small bowel Video Capsule Endoscopy (VCE) using an Capsule System equipped with a Deep Neural Network based system called SmartScan (SC),Also: Video Capsule Endoscopy (VCE), DNN SmartScan systemSmall bowel Video Capsule Endoscopy (VCE) will be performed using the an Capsule System equipped with a Deep Neural Network based system called SmartScan (SC), which is able to automatically select suspected lesions thus creating a very short video constituted only by selected images. | Device | Suspected Crohn's Disease |
Primary outcome
Diagnostic yield (DY)
Time frame: through study completion, an average of 1 year
Non-inferiority of AI-assisted reading (AIR) compared to standard reading (SR) in detecting (diagnostic yield - DY) typical lesions of suspected CD (erosions and/or ulcers and/or stenosis).
1 secondary outcome
VCE reading time
Time frame: through study completion, an average of 1 year
Results and safety
This study is still under way. Results are not available in the source record yet.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 2 Sep 2026.
- Individual participant dataSharing planned: Yes
Related trials for Crohn Disease (CD)
Enrolling by invitationPhase 4
INSIGHT-IBD Pragmatic Study
Ulcerative Colitis (UC), Crohn Disease (CD)
RecruitingPhase 4
A Study of Vedolizumab in Adults With Ulcerative Colitis (UC) or Crohn's Disease (CD) in the Community Setting
Ulcerative Colitis, Crohn's Disease
RecruitingPhase 4
Open-label Single-arm Study to Assess the Efficacy of Mirikizumab in Patients With Inflammatory Strictures Due to CD
Crohn Disease
Not yet recruitingObservational study
MENA/Levant Epidemiological, Registry of Immunological & Clinical Traits (MERIT)
Antiphospholipid (aPL)-Positive, Rheumatic Arthritis
Active, not recruitingPhase 4
A Study of Vedolizumab Intravenous (IV) and Adalimumab or Vedolizumab and Ustekinumab in Adults With Crohn's Disease
Crohn's Disease
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part.
Cristiano Spada, Prof study director
Fondazione Poliambulanza, Policlinico A Gemelli
Paola Cesaro, PhD study director
Fondazione Poliambulanza
Stefania Piccirelli, MD principal investigator
Fondazione Poliambulanza
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Crohn Disease (CD), run by Fondazione Poliambulanza Istituto Ospedaliero at 1 site in Italy.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 16 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: looking for participants now, as of the sponsor's last update on 2 Sep 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Italy. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
This study is still under way. Results are not available in the source record yet.
How can a doctor refer a patient or contact the research team?
Contact Stefania Piccirelli, MD (0039 0303518364, stefania.piccirelli@poliambulanza.it), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Diagnostic yield (DY) (time frame: through study completion, an average of 1 year). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 2 Sep 2026.