Meibomian Gland DysfunctionNCT04454983
Lipiflow vs iLux Patient Acceptance and Comfort Study
A study testing Lipiflow Thermal Pulsation System and iLux System in people with Meibomian Gland Dysfunction and Dry Eye, run by Epstein, Arthur B., OD, FAAO at 1 site in United States.
Trial summary
This study was designed to compare patient acceptance, comfort, and preference between two meibomian gland clearing devices (Lipiflow vs, iLux). Primary Objective was to compare patient comfort as assessed by Likert-style scale questionnaire following each bilateral procedure. Read more about this study
- Who is it for?
- Ages 18 years and olderHealthy volunteers can take part
- Conditions the study is for
- Meibomian Gland Dysfunction, Dry Eye
- What is being tested?
- Lipiflow Thermal Pulsation System and iLux System
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 43 participants
- Where
- 1 siteUnited States
- Study dates
- 11 Jan 2020to 29 Feb 2020
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Who may be able to join
- Subject can be of any gender or race
- Subject must be 18 years of age or older at the time of informed consent
- 2. Subject must be able to understand and must sign an Informed Consent that has been approved by an IRB 3. Subject must have confirmed diagnosis of Meibomian Gland Dysfunction 4. Subject must agree to not wear contact lenses the day of the Study visit
Who cannot join
- History of intraocular or oculoplastic surgery within 6 months of Screening visit
- History of ocular injury or trauma, chemical burns, or limbal stem cell deficiency within 3 months of the Screening visit
- Active ocular infection or active ocular inflammation (including allergic conjunctivitis, vernal or giant papillary conjunctivitis) at time of Screening visit
- History of ocular surface abnormality that may compromise corneal integrity
- History of treatment with LipiFlow or iLux in either eye in the last 6 months
- Allergy to topical proparacaine eye drops
Trial locations and contacts
1 site in 1 country.
About this study
This study was designed to compare patient acceptance, comfort, and preference between two meibomian gland clearing devices (Lipiflow vs, iLux). Primary Objective was to compare patient comfort as assessed by Likert-style scale questionnaire following each bilateral procedure. Secondary Objective was to compare overall experience and treatment preference as assessed by Likert-style questionnaire following each bilateral procedure. Both devices are exempt from IDE regulations [21 CFR 812.2(c)].
Read the detailed description
Introduction Meibomian gland disease (MGD) is increasingly recognized as a primary cause or contributor to tear instability and dry eye disease. Effective management of this disorder often requires meibomian gland expression and clearance. A variety of devices which apply pressure, heat or a combination of both to the glands have been used.
Two such devices that apply heat and pressure simultaneously are commercially available. LipiFlow (JNJ Vision Care) is an automated computer-controlled device that uses vectored thermal (hydraulic) pulsation applied by an activator device placed on the eye between the globe and the eyelids to achieve gland clearance. The iLux System (Alcon) is an operator controlled assisted manual device which applies heat generated by infrared LEDs and expression through cam driven mechanical pressure applied to the lids.
Device Descriptions LipiFlow Thermal Pulsation System
The Lipiflow Thermal Pulsation System is a commercially available device used in the treatment of MGD. It is cleared to be marketed by the United States Food and Drug Administration. The LipiFlow Thermal Pulsation System is intended for the application of localized heat and pressure therapy in adult patients with chronic cystic conditions of the eyelids, including meibomian gland dysfunction (MGD), also known as evaporative dry eye or lipid deficiency dry eye.
The LipiFlow Console provides the user interface and control elements of the system, including all software, algorithms and control elements. The Activator, a single-use sterile device, delivers automated therapeutic energies to each meibomian gland. Its contoured design vaults the cornea and protects the eye allowing a maximum therapeutic temperature of 43 degrees Celsius to reach glands from the inner eyelid, without damaging the eyelid or delicate structures of the globe. Insulation protects the cornea from exceeding a safe 39.5 degrees Celsius, while a pressure feedback loop sends pulsed sequences to expel blockages. Force equalization protects the globe from pressure transmission by focusing energy only on the eyelid. Delivered through the LipiFlow Activator, Vectored Thermal Pulse™ (VTP) technology applies a combination of heat and pressure to the inner eyelid to safely remove gland obstructions and stagnant gland content. Vectored heat and adaptive force equalization target the pulse, heat, and pressure on the meibomian glands to maximize effectiveness. Therapeutic motion provides proximal-to-distal peristalsis to clear gland contents.
iLux System
The iLux™ System is a medical device commercially available for use by Eye Care Professionals (ECP) to apply localized heat and pressure therapy to a patient's eyelids. It is cleared to be marketed by the United States Food and Drug Administration. The system consists of a handheld instrument coupled to a single-use, sterile disposable component that is positioned to bridge the eyelid. The iLux device allows an ECP to view the eyelid margin through a magnifier, then warm the eyelid tissue to a range of 40 to 42˚C, and then apply force-limited compression to the eyelid in order to express melted meibum from obstructed glands. The iLux System is indicated for the application of localized heat and pressure therapy in adult patients with chronic cystic conditions of the eyelids, including meibomian gland dysfunction (MGD), also known as evaporative dry eye.
The iLux Instrument is a handheld, electronic instrument used together with the iLux disposable to apply heating and pressure to the eyelid. The Instrument includes electronic circuits that read sensors in the Inner and Outer Eyelid Pads to measure temperatures representative of inner and outer eyelid temperature, respectively. Warming is accomplished using light energy emitted from LEDs in the Instrument. The LEDs are located behind a clear window on the open end of the Shroud. Two wavelengths of light are used: lime-green (568 nm) and near-infrared (850 nm). A mechanism in the Instrument allows the operator to apply pressure to the eyelid by controlling the movement of the Outer Pad using finger pressure applied to the Compression Control button. The force applied to the Compression Control is measured by a sensor in this mechanism. A graphic Screen displays information for operating the Instrument during a treatment.
Study Purpose / Objectives This study is designed to compare patient acceptance, comfort, and preference between two meibomian gland clearing devices. Both devices are exempt from IDE regulations [21 CFR 812.2(c)]. Primary Objective is to compare patient comfort as assessed by Likert-style scale questionnaire following each bilateral procedure. Secondary Objective is to compare overall experience and treatment preference as assessed by Likert-style questionnaire following each bilateral procedure.
Background "Comparison Between iLux™ and LipiFlow® in the Treatment of Meibomian Gland Dysfunction" listed on ClincalTrials.gov looked at a 4-week efficacy comparison between the two treatment devices. Pain and discomfort data were collected regarding the two procedures but was not analyzed for significance due to no pre-trial hypothesis. The raw data shows lower pain and discomfort scores immediately following the procedure for the Lipiflow as compared to iLux with similar pre-treatment and one-day post post-treatment scores (Thornhill 2019). There is currently no published research on the patient acceptance, comfort, and preference comparing any meibomian gland emptying devices.
- Conditions
- Meibomian Gland Dysfunction, Dry Eye
- Being tested
- Lipiflow Thermal Pulsation System, iLux System
- Keywords
- meibomian gland dysfunction, dry eye, Lipiflow, iLux
- Medical subject headings
- Meibomian Gland Dysfunction, Dry Eye Syndromes
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Lipiflow Thermal Pulsation SystemDevice
The LipiFlow Console provides the user interface and control elements of the system, including all software, algorithms and control elements. The Activator, a single-use sterile device, delivers automated therapeutic energies to each meibomian gland. Its contoured design vaults the cornea and protects the eye allowing a maximum therapeutic temperature of 43 degrees Celsius to reach glands from the inner eyelid. Insulation protects the cornea from exceeding a safe 39.5 degrees Celsius, while a pressure feedback loop sends pulsed sequences to expel blockages. Force equalization protects the globe from pressure transmission by focusing energy only on the eyelid. Delivered through the LipiFlow Activator, Vectored Thermal Pulse™ technology applies a combination of heat and pressure to the inner eyelid to safely remove gland obstructions and stagnant gland content. Therapeutic motion provides proximal-to-distal peristalsis to clear gland contents.
iLux SystemDevice
The iLux™ System is used to apply localized heat and pressure to a patient's eyelids. The system consists of a handheld instrument coupled to a single-use, sterile disposable component that is positioned to bridge the eyelid. The iLux device allows view of the eyelid through a magnifier, then warms the eyelid to 40 to 42˚C, then force-limited compression is applied manually to express the melted meibum from obstructed glands. Warming is accomplished using light energy emitted from LEDs in the Instrument. The LEDs are located behind a clear window on the open end of the Shroud. Two wavelengths of light are used: lime-green (568 nm) and near-infrared (850 nm). A mechanism in the Instrument allows the operator to apply pressure to the eyelid by controlling the movement of the Outer Pad using finger pressure applied to the Compression Control button. The force applied to the Compression Control is measured by a sensor in this mechanism.
| Study group | Role | What they receive |
|---|---|---|
| Lipiflow - All Subjects | Experimental | Both Lipiflow and iLux procedures were performed bilaterally on all subjects on the same day. Subjects were randomized to which procedure they received first. There was a 1-hour wait between procedures. Receives: Device: Lipiflow Thermal Pulsation System |
| iLux - All Subjects | Experimental | Both Lipiflow and iLux procedures were performed bilaterally on all subjects on the same day. Subjects were randomized to which procedure they received first. There was a 1-hour wait between procedures. Receives: Device: iLux System |
What is being measured
The primary outcome is the main question the study is designed to answer.
Procedure Comfort
Likert-scale questionnaire: 1=strongly disagree, 2=disagree, 3=Undecided, 4=Agree, 5=strongly agree - 1 Question
Measured: 5 minutes
Secondary outcomes (2)
Procedure Experience
Likert-scale questionnaire: 1=strongly disagree, 2=disagree, 3=Undecided, 4=Agree, 5=strongly agree - 4 Questions
Measured: 5 minutes
Patient Preference
Questionnaire: Lipiflow, iLux, No Preference
Measured: 5 minutes
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted2 Jul 2020
- Study start11 Jan 2020
- Primary completion29 Feb 2020
- Study completion29 Feb 2020
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Meibomian Gland DysfunctionStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Other
- Allocation
- Randomised
- Intervention model
- Crossover
- Model description
- This study is an open-label, single site, crossover trial comparing LipiFlow Thermal Pulsation System to the iLux System based on patient acceptance, comfort, and preference.
- Masking
- None (open label)
- Enrolment
- 43 participants (actual)
Sponsor and investigators
- Lead sponsor
- Epstein, Arthur B., OD, FAAO
- Collaborators
- Johnson & Johnson Vision Care, Inc.
- Responsible party
- Principal investigator, Dr. Arthur Epstein, Epstein, Arthur B., OD, FAAO
- Investigators
- Arthur B Epstein, OD, Principal investigator, Ophthalmic Research Consultants of Arizona
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04454983
- Sponsor's protocol ID
- PEC-Sep2019-Lipi-iLux
- Status last verified
- Aug 2020
- First submitted
- 28 Jun 2020
- Last updated
- 19 Aug 2020
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No: There is not a plan to make IPD available.
Study at a glance
From the registry record, last updated by the sponsor on 19 Aug 2020. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Lipiflow vs iLux Patient Acceptance and Comfort Study
- ClinicalTrials.gov ID
- NCT04454983
- Acronym / sponsor ID
- PEC-Sep2019-Lipi-iLux
- Conditions
- Meibomian Gland Dysfunction, Dry Eye
- Keywords
- meibomian gland dysfunction, dry eye, Lipiflow, iLux
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 43 participants (actual)
- Lead sponsor
- Epstein, Arthur B., OD, FAAO
- Collaborators
- Johnson & Johnson Vision Care, Inc.
- Study start
- 11 Jan 2020 (actual)
- Primary completion
- 29 Feb 2020 (actual)
- Study completion
- 29 Feb 2020 (actual)
- First posted
- 2 Jul 2020 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This study was designed to compare patient acceptance, comfort, and preference between two meibomian gland clearing devices (Lipiflow vs, iLux). Primary Objective was to compare patient comfort as assessed by Likert-style scale questionnaire following each bilateral procedure. Secondary Objective was to compare overall experience and treatment preference as assessed by Likert-style questionnaire following each bilateral procedure. Both devices are exempt from IDE regulations [21 CFR 812.2(c)].
Detailed description
Introduction Meibomian gland disease (MGD) is increasingly recognized as a primary cause or contributor to tear instability and dry eye disease. Effective management of this disorder often requires meibomian gland expression and clearance. A variety of devices which apply pressure, heat or a combination of both to the glands have been used.
Two such devices that apply heat and pressure simultaneously are commercially available. LipiFlow (JNJ Vision Care) is an automated computer-controlled device that uses vectored thermal (hydraulic) pulsation applied by an activator device placed on the eye between the globe and the eyelids to achieve gland clearance. The iLux System (Alcon) is an operator controlled assisted manual device which applies heat generated by infrared LEDs and expression through cam driven mechanical pressure applied to the lids.
Device Descriptions LipiFlow Thermal Pulsation System
The Lipiflow Thermal Pulsation System is a commercially available device used in the treatment of MGD. It is cleared to be marketed by the United States Food and Drug Administration. The LipiFlow Thermal Pulsation System is intended for the application of localized heat and pressure therapy in adult patients with chronic cystic conditions of the eyelids, including meibomian gland dysfunction (MGD), also known as evaporative dry eye or lipid deficiency dry eye.
The LipiFlow Console provides the user interface and control elements of the system, including all software, algorithms and control elements. The Activator, a single-use sterile device, delivers automated therapeutic energies to each meibomian gland. Its contoured design vaults the cornea and protects the eye allowing a maximum therapeutic temperature of 43 degrees Celsius to reach glands from the inner eyelid, without damaging the eyelid or delicate structures of the globe. Insulation protects the cornea from exceeding a safe 39.5 degrees Celsius, while a pressure feedback loop sends pulsed sequences to expel blockages. Force equalization protects the globe from pressure transmission by focusing energy only on the eyelid. Delivered through the LipiFlow Activator, Vectored Thermal Pulse™ (VTP) technology applies a combination of heat and pressure to the inner eyelid to safely remove gland obstructions and stagnant gland content. Vectored heat and adaptive force equalization target the pulse, heat, and pressure on the meibomian glands to maximize effectiveness. Therapeutic motion provides proximal-to-distal peristalsis to clear gland contents.
iLux System
The iLux™ System is a medical device commercially available for use by Eye Care Professionals (ECP) to apply localized heat and pressure therapy to a patient's eyelids. It is cleared to be marketed by the United States Food and Drug Administration. The system consists of a handheld instrument coupled to a single-use, sterile disposable component that is positioned to bridge the eyelid. The iLux device allows an ECP to view the eyelid margin through a magnifier, then warm the eyelid tissue to a range of 40 to 42˚C, and then apply force-limited compression to the eyelid in order to express melted meibum from obstructed glands. The iLux System is indicated for the application of localized heat and pressure therapy in adult patients with chronic cystic conditions of the eyelids, including meibomian gland dysfunction (MGD), also known as evaporative dry eye.
The iLux Instrument is a handheld, electronic instrument used together with the iLux disposable to apply heating and pressure to the eyelid. The Instrument includes electronic circuits that read sensors in the Inner and Outer Eyelid Pads to measure temperatures representative of inner and outer eyelid temperature, respectively. Warming is accomplished using light energy emitted from LEDs in the Instrument. The LEDs are located behind a clear window on the open end of the Shroud. Two wavelengths of light are used: lime-green (568 nm) and near-infrared (850 nm). A mechanism in the Instrument allows the operator to apply pressure to the eyelid by controlling the movement of the Outer Pad using finger pressure applied to the Compression Control button. The force applied to the Compression Control is measured by a sensor in this mechanism. A graphic Screen displays information for operating the Instrument during a treatment.
Study Purpose / Objectives This study is designed to compare patient acceptance, comfort, and preference between two meibomian gland clearing devices. Both devices are exempt from IDE regulations [21 CFR 812.2(c)]. Primary Objective is to compare patient comfort as assessed by Likert-style scale questionnaire following each bilateral procedure. Secondary Objective is to compare overall experience and treatment preference as assessed by Likert-style questionnaire following each bilateral procedure.
Background "Comparison Between iLux™ and LipiFlow® in the Treatment of Meibomian Gland Dysfunction" listed on ClincalTrials.gov looked at a 4-week efficacy comparison between the two treatment devices. Pain and discomfort data were collected regarding the two procedures but was not analyzed for significance due to no pre-trial hypothesis. The raw data shows lower pain and discomfort scores immediately following the procedure for the Lipiflow as compared to iLux with similar pre-treatment and one-day post post-treatment scores (Thornhill 2019). There is currently no published research on the patient acceptance, comfort, and preference comparing any meibomian gland emptying devices.
Study design
- Primary purpose
- Other
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- None (open label)
- Number of arms
- 2
- Model description
- This study is an open-label, single site, crossover trial comparing LipiFlow Thermal Pulsation System to the iLux System based on patient acceptance, comfort, and preference.
| Arm | Type | Receives |
|---|---|---|
| Lipiflow - All Subjects | Experimental | Device: Lipiflow Thermal Pulsation SystemBoth Lipiflow and iLux procedures were performed bilaterally on all subjects on the same day. Subjects were randomized to which procedure they received first. There was a 1-hour wait between procedures. |
| iLux - All Subjects | Experimental | Device: iLux SystemBoth Lipiflow and iLux procedures were performed bilaterally on all subjects on the same day. Subjects were randomized to which procedure they received first. There was a 1-hour wait between procedures. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (3 listed)
- Subject can be of any gender or race
- Subject must be 18 years of age or older at the time of informed consent
- 2. Subject must be able to understand and must sign an Informed Consent that has been approved by an IRB 3. Subject must have confirmed diagnosis of Meibomian Gland Dysfunction 4. Subject must agree to not wear contact lenses the day of the Study visit
Key exclusion criteria (6 listed)
- History of intraocular or oculoplastic surgery within 6 months of Screening visit
- History of ocular injury or trauma, chemical burns, or limbal stem cell deficiency within 3 months of the Screening visit
- Active ocular infection or active ocular inflammation (including allergic conjunctivitis, vernal or giant papillary conjunctivitis) at time of Screening visit
- History of ocular surface abnormality that may compromise corneal integrity
- History of treatment with LipiFlow or iLux in either eye in the last 6 months
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Lipiflow Thermal Pulsation SystemThe LipiFlow Console provides the user interface and control elements of the system, including all software, algorithms and control elements. The Activator, a single-use sterile device, delivers automated therapeutic energies to each meibomian gland. Its contoured design vaults the cornea and protects the eye allowing a maximum therapeutic temperature of 43 degrees Celsius to reach glands from the inner eyelid. Insulation protects the cornea from exceeding a safe 39.5 degrees Celsius, while a pressure feedback loop sends pulsed sequences to expel blockages. Force equalization protects the globe from pressure transmission by focusing energy only on the eyelid. Delivered through the LipiFlow Activator, Vectored Thermal Pulse™ technology applies a combination of heat and pressure to the inner eyelid to safely remove gland obstructions and stagnant gland content. Therapeutic motion provides proximal-to-distal peristalsis to clear gland contents. | Device | Lipiflow - All Subjects |
| iLux SystemThe iLux™ System is used to apply localized heat and pressure to a patient's eyelids. The system consists of a handheld instrument coupled to a single-use, sterile disposable component that is positioned to bridge the eyelid. The iLux device allows view of the eyelid through a magnifier, then warms the eyelid to 40 to 42˚C, then force-limited compression is applied manually to express the melted meibum from obstructed glands. Warming is accomplished using light energy emitted from LEDs in the Instrument. The LEDs are located behind a clear window on the open end of the Shroud. Two wavelengths of light are used: lime-green (568 nm) and near-infrared (850 nm). A mechanism in the Instrument allows the operator to apply pressure to the eyelid by controlling the movement of the Outer Pad using finger pressure applied to the Compression Control button. The force applied to the Compression Control is measured by a sensor in this mechanism. | Device | iLux - All Subjects |
Primary outcome
Procedure Comfort
Time frame: 5 minutes
Likert-scale questionnaire: 1=strongly disagree, 2=disagree, 3=Undecided, 4=Agree, 5=strongly agree - 1 Question
2 secondary outcomes
Procedure Experience
Time frame: 5 minutes
Patient Preference
Time frame: 5 minutes
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 19 Aug 2020.
- Comparison Between iLux™ and LipiFlow® in the Treatment of Meibomian Gland DysfunctionLink provided by the sponsor.
- Individual participant dataSharing planned: No. There is not a plan to make IPD available.
Related trials for Meibomian Gland Dysfunction
Active, not recruiting
Clinical Study Evaluating Nordlys™ SWT IPL for Dry Eye Disease (DED) Due to MGD
Meibomian Gland Dysfunction, Dry Eye Disease
Not yet recruiting
TearCare in Young Adults
Meibomian Gland Dysfunction (Disorder)
Active, not recruitingPhase 2
Autologous Serum Obtained by a Closed-Circuit Collection Device
GVHD, Meibomian Gland Dysfunction (Disorder)
Not yet recruitingObservational study
Ocular Surface Changes and Meibomian Gland Dysfunction in Rheumatologic Patients
Meibomian Gland Dysfunction, Dry Eye Syndromes
Enrolling by invitation
Microbiome-Focused Food Supplement for Evaporative Dry Eye Due to Meibomian Gland Dysfunction
Dry Eye, Evaporative Dry Eye Disease
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Arthur B Epstein, OD principal investigator
Ophthalmic Research Consultants of Arizona
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Lipiflow Thermal Pulsation System and iLux System in people with Meibomian Gland Dysfunction and Dry Eye, run by Epstein, Arthur B., OD, FAAO at 1 site in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 19 Aug 2020. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Procedure Comfort (time frame: 5 minutes). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 19 Aug 2020.