Body Temperature ChangesNCT04463537
The Effect of Auricle Position on Tympanic Thermometry
A study testing Body Temperature Measurements in people with Body Temperature Changes, run by Ege University.
Trial summary
Objective: The aim of this study was to investigate the effect of auricle position on body temperature measurements made with tympanic membrane thermometer in adult patients. Methods: The study was conducted with a quasi-experimental design with a pre-test and a post-test. Read more about this study
- Who is it for?
- Ages 18 to 70 yearsHealthy volunteers can take part
- Conditions the study is for
- Body Temperature Changes
- What is being tested?
- Body Temperature Measurements
- Type of treatment
- Surgery or procedure
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 143 participants
- Where
- No sites listed yet
- Study dates
- 1 Nov 2016to 5 Jan 2017
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 70 years
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Who may be able to join
- The patients who were 18 years old or older, conscious, without communication issues, volunteers, not diagnosed with otitis media, who did not have a fever.
Who cannot join
- havin fever, Being under the age of 18, not volunteers.
About this study
Official title: The Effect Of Auricle Position On Body Temperature Measurements Made With Tympanic Membrane Thermometer In Adults
Objective: The aim of this study was to investigate the effect of auricle position on body temperature measurements made with tympanic membrane thermometer in adult patients.
Methods: The study was conducted with a quasi-experimental design with a pre-test and a post-test. A total of 143 patients who fit the inclusion criteria of the study were included in the sample. The research carried out between 1 November - 31 December 2016 in the emergency department. Body temperature measurements were carried out on the patients in the study firstly by not changing the position of the auricle and then repeated after a minute, this time by changing the position of the auricle.
Read more
Results: The difference between the measurement values found in two different positions was 0.31 0C, and the Bland Altman plot showed that the differences were distributed systematically around the value 0.31. The difference between the lengths of measurements performed on two separate positions was detected to be 1.08 second. During body temperature measurements performed through giving position to auricle, 59.2 % of the patients never felt discomfort.
Conclusions: It was found in the comparison of two positions that there was a significant difference between the tympanic membrane thermometer measurements made by positioning the auricle and those without positioning.
Read the detailed description
Introduction One of the most common practices in clinical investigations is the measurement of a patient's body temperature (1-2,3). Body temperature measurement has a significant place in evaluation of clinical pictures and clinical monitoring (4). The issue at hand is that various temperature measurement modalities yield different results (2-4).
Although the accuracy of temperatures measured by infrared tympanic thermometers is a controversial issue among people interested in the subject, these thermometers have many advantages; they measure the temperature fast (1-2 s), and they are easy to use and non-invasiveness (3). Compared to the armpit or oral temperatures, the tympanic temperature reflects the core temperature more accurately which was demonstrated by comparing the temperature measurements made in the pulmonary artery and esophagus (5-6).
Methods Aim The aim of this study investigate the effects of auricle position on body temperature values in tympanic membrane thermometer measurements performed on adult patients. The hypothesis was "Position of the auricle during measurement of tympanic membrane temperature will affect the reading".
Design The study was conducted with a quasi-experimental design with a pre-test and a post-test.
The Study Participants This cross-sectional study surveyed 143 patients from one of emergency department in Turkey. The patients who were 18 years old or older, conscious, without communication issues, volunteers, not diagnosed with otitis media, who did not have a fever. Because otitis media and fever cause to potential sources of bias. A sample of the study with 143 patients who meeting these criteria and agreed to participate in the study was generated.
Data collection The data were collected by "a Personal Information Form, a Visual Comparison Scale, a tympanic membrane thermometer and a stop watch" by the researcher on 143 patients who selected convenience sampling at the Emergency Services of a university hospital in the period of 1 November - 31 December 2016.
Data Collection Tolls The "Personal Information Form" is a form that includes three questions based on socio-demographic characteristics (age, sex, presence of otitis media), this form was developed by the researchers. "Tympanic membrane thermometer" were used during body temperature measurements. The "Visual Comparison Scale" is used in evaluating the discomfort the patients feel based on auricle position change during the body temperature measurement, and it records the values for the duration of the body temperature measurement process and body temperature. This form was developed by the researchers. The score range of the "Visual Comparison Scale" is between 0 and 10.
According to this scale, while "0" means "I do not feel discomforted", "10" means "I feel terribly discomforted". "Stop watch" was used to record whether there is a difference between the measurement processes in terms of duration.
To measure the body temperature in all the patients, only the Covidien brand tympanic membrane thermometer was used. Before the study was started, the Covidien brand tympanic membrane thermometer was calibrated and a pilot study was conducted with 15 people to assure the accuracy of the thermometer.
Intervention Firstly, patients selected with convenience sampling. In the sampling method, the order of the patients' enrollment to the emergency room was used. Then, patient's age, sex and presence of otitis media were recorded in the Personal Information Form.
After recording, measurements were carried out on the patients in the study firstly by not changing the position of the auricle. The duration was measured by stop watch and the results were recorded in the data form. The levels of patients' discomfort were evaluated by the "Visual Comparison Scale".
The measurement was then repeated after a minute, this time by changing the position of the auricle. The duration was measured for this position and the results were recorded in the data form. The levels of patients' discomfort were evaluated by the "Visual Comparison Scale". The auricle on the same side was used during both measurements.
Sample Size Calculation In order to determine the sample size, a pre-administration was conducted on a total of 15 adult patients. The collected data were subjected to a power analysis. The effect size was determined as d=0.3645, according to the evaluation that was conducted by using these data. To obtain 99% power at a level of α=0.05, it was determined that there must be 110 patient in the groups. When considering that there may be a loss of data in the study process, it was decided that the study should be conducted on a total of 143 participants.
Ethical Considerations Approval (number: 2015-106) was received for the study from the Scientific Ethics Board of University, Faculty of Nursing. Written permission was taken from the Chief Physician of the Hospital of University, Faculty of Medicine for conducting the study in the emergency department of the hospital, while written consent was received from patients themselves after information was provided about the purpose of the study.
Analysis The statistical analysis of the data obtained in the study was achieved using the Statistical Package for the Social Sciences (SPSS) 22.0. For analysis of the data, frequencies, percentages, means and standard deviations were calculated, and the significance of the difference between paired values was tested in order to investigate the effects of auricle position on measurement values. Additionally, systematic distributions of the data were examined with a Bland Altman plot which is used in repeated measurements based on positions. The results were interpreted in a 95% confidence interval and a level of significance of p<0.05.
The mean value taken from the measurements with the tympanic membrane thermometer was 36.99±0.48 in measurements by positioning the auricle, and 36.68±0.47 in measurements without positioning. The difference between the measurements obtained in two different positions was found as 0.31 0C. Accordingly, it was found that the difference between the values in two different measurement positions was noteworthy (t=15.12; p< 0.05).
While one of the researchers measured the temperature with the tympanic membrane thermometer, the other researcher measured the amount of time elapsed with a stopwatch and recorded it. The mean duration of measurement was 5.51 seconds (min: 3.5 max: 7.3) in the measurements made by positioning the auricle, and 4.42 seconds (min: 2.9 max: 7.6) in the measurements without positioning. Considering the difference between the durations of measurements made in two different positions ( =1.08±0.07) it was found that the difference was significant between the measurements with positioning and those without positioning (t=15.16; p< 0.05).
Table II. Measurement results according to pinna position and durations of the measurements taken in the comparison of the two positions.
Conclusion This article contributes the main finding that nurses should be change the position of the pinna while measuring the temperature with tympanic membrane thermometers. Placing the sensor tip of the thermometer into the ear canal and pulling the auricle allows easy access to the tympanic membrane by straightening the external canal and it reflected the core temperature accurately.
Utilization of tympanic membrane thermometers in measurement of body temperature is highly important and technique should be applied properly to obtain correct values in emergency department. In the light of the results we obtained in this study, in order to achieve accurate and reliable measurement values the auricle should be positioned correctly, and the ear canal should be straightened. This way, the tympanic membrane that receives blood via the external cerebral artery is placed straight ahead the infrared rays. This method of body temperature measurement should be included in the in-service training or nurses, as it is one of the jobs of nurses to measure body temperature.
The information in user manuals in Turkish about tympanic membrane thermometers should be updated to include the steps in the process of body temperature measurement, and nurses should use this method effectively. The information in the literature relative to nursing practices on measurements made with tympanic membrane thermometers should be updated. It was found that the measurements made by positioning the auricle did not require an extra application time and this application would not be an additional workload for the nurses. It was determined that body temperature measurement by placing auricle in position did not cause discomfort in patients. Studies about the accuracy and reliability of measurements made with tympanic membrane thermometers should be repeated on different samples and the results should be shared.
References
- Chaglla JSE, Celik N, Balachandran W. Measurement of Core Body Temperature Using Graphene-Inked Infrared Thermopile. Sensor 2018;18:3315-23. Doi: 10.3390/s18103315.
- Arslan GG, Eşer İ, Khorshıd L. Analysis of the effect of lying on the ear on body temperature measurement using a tympanic thermometer. Journal of Pakistan Medical Association 2011; 61:1065. Retrieved from http://jpma.org.pk/PdfDownload/3100.pdf.
- Erickson RS, Kirklin SK. Comparison of ear-based, bladder, oral, and axillary methods for core temperature measurement. Critical care medicine, 1993;21(10): 1528-1534.
- Yeoh WK, Lee JKW, Lim HY, Gan CW, Liang W, Tan KK. Re-visiting the tympanic membrane vicinity as core body temperature measurement site. PLoS ONE 2017; 2 (4): 1-21. Doi: 10.1371/journal.pone.0174120.
- Stavem, Saxholm, Smith-Erichsen, 1997
- Yaron M, Lowenstain SR, Koziol McLain J. Measuring the accuracy of the infrared tympanic thermometer. Journal of Emergency Medicine 1995;13:617-621. Doi: 10.1016/0736-4679(95)00065-i
- Conditions
- Body Temperature Changes
- Being tested
- Body Temperature Measurements
- Keywords
- body temperature,, adult patients,, tympanic membrane thermometer,, auricle position,, nursing practice.
- Medical subject headings
- Body Temperature Changes
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Body Temperature MeasurementsProcedure or surgery
measurements were carried out on the patients in the study firstly by not changing the position of the auricle. The duration was measured by stop watch and the results were recorded in the data form. The levels of patients' discomfort were evaluated by the "Visual Comparison Scale".
The measurement was then repeated after a minute, this time by changing the position of the auricle. The duration was measured for this position and the results were recorded in the data form.
| Study group | Role | What they receive |
|---|---|---|
| experiment group | Experimental | Firstly, patients selected with convenience sampling. In the sampling method, the order of the patients' enrollment to the emergency room was used. Then, patient's age, sex and presence of otitis media were recorded in the Personal Information Form.
After recording, measurements were carried out on the patients in the study firstly by not changing the position of the auricle. The duration was measured by stop watch and the results were recorded in the data form. The levels of patients' discomfort were evaluated by the "Visual Comparison Scale".
The measurement was then repeated after a minute, this time by changing the position of the auricle. The duration was measured for this position and the results were recorded in the data form. The levels of patients' discomfort were evaluated by the "Visual Comparison Scale". The auricle on the same side was used during both measurements. Receives: Procedure: Body Temperature Measurements |
What is being measured
The primary outcome is the main question the study is designed to answer.
outcome1
It was found in the comparison of two positions that there was a significant difference between the tympanic membrane thermometer measurements made by positioning the auricle and those without positioning
Measured: NOVEMBER 2016 JANUARY 2017
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted9 Jul 2020
- Study start1 Nov 2016
- Primary completion1 Dec 2016
- Study completion5 Jan 2017
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Body Temperature ChangesStudies of the same condition, open and under way.
- More trials run by Ege UniversityThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Model description
- a quasi-experimental design with a pre-test and a post-test.
- Masking
- None (open label)
- Enrolment
- 143 participants (actual)
Sponsor and investigators
- Lead sponsor
- Ege University
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Nilay Orkun, Ege University
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04463537
- Sponsor's protocol ID
- 2015-106
- Status last verified
- Jul 2020
- First submitted
- 7 Jul 2020
- Last updated
- 9 Jul 2020
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No: I have not IPD
Study at a glance
From the registry record, last updated by the sponsor on 9 Jul 2020. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- The Effect Of Auricle Position On Body Temperature Measurements Made With Tympanic Membrane Thermometer In Adults
- ClinicalTrials.gov ID
- NCT04463537
- Acronym / sponsor ID
- 2015-106
- Conditions
- Body Temperature Changes
- Keywords
- body temperature,, adult patients,, tympanic membrane thermometer,, auricle position,, nursing practice.
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 143 participants (actual)
- Lead sponsor
- Ege UniversityUniversity, hospital or other
- Study start
- 1 Nov 2016 (actual)
- Primary completion
- 1 Dec 2016 (actual)
- Study completion
- 5 Jan 2017 (actual)
- First posted
- 9 Jul 2020 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Objective: The aim of this study was to investigate the effect of auricle position on body temperature measurements made with tympanic membrane thermometer in adult patients.
Methods: The study was conducted with a quasi-experimental design with a pre-test and a post-test. A total of 143 patients who fit the inclusion criteria of the study were included in the sample. The research carried out between 1 November - 31 December 2016 in the emergency department. Body temperature measurements were carried out on the patients in the study firstly by not changing the position of the auricle and then repeated after a minute, this time by changing the position of the auricle.
Results: The difference between the measurement values found in two different positions was 0.31 0C, and the Bland Altman plot showed that the differences were distributed systematically around the value 0.31. The difference between the lengths of measurements performed on two separate positions was detected to be 1.08 second. During body temperature measurements performed through giving position to auricle, 59.2 % of the patients never felt discomfort.
Conclusions: It was found in the comparison of two positions that there was a significant difference between the tympanic membrane thermometer measurements made by positioning the auricle and those without positioning.
Detailed description
Introduction One of the most common practices in clinical investigations is the measurement of a patient's body temperature (1-2,3). Body temperature measurement has a significant place in evaluation of clinical pictures and clinical monitoring (4). The issue at hand is that various temperature measurement modalities yield different results (2-4).
Although the accuracy of temperatures measured by infrared tympanic thermometers is a controversial issue among people interested in the subject, these thermometers have many advantages; they measure the temperature fast (1-2 s), and they are easy to use and non-invasiveness (3). Compared to the armpit or oral temperatures, the tympanic temperature reflects the core temperature more accurately which was demonstrated by comparing the temperature measurements made in the pulmonary artery and esophagus (5-6).
Methods Aim The aim of this study investigate the effects of auricle position on body temperature values in tympanic membrane thermometer measurements performed on adult patients. The hypothesis was "Position of the auricle during measurement of tympanic membrane temperature will affect the reading".
Design The study was conducted with a quasi-experimental design with a pre-test and a post-test.
The Study Participants This cross-sectional study surveyed 143 patients from one of emergency department in Turkey. The patients who were 18 years old or older, conscious, without communication issues, volunteers, not diagnosed with otitis media, who did not have a fever. Because otitis media and fever cause to potential sources of bias. A sample of the study with 143 patients who meeting these criteria and agreed to participate in the study was generated.
Data collection The data were collected by "a Personal Information Form, a Visual Comparison Scale, a tympanic membrane thermometer and a stop watch" by the researcher on 143 patients who selected convenience sampling at the Emergency Services of a university hospital in the period of 1 November - 31 December 2016.
Data Collection Tolls The "Personal Information Form" is a form that includes three questions based on socio-demographic characteristics (age, sex, presence of otitis media), this form was developed by the researchers. "Tympanic membrane thermometer" were used during body temperature measurements. The "Visual Comparison Scale" is used in evaluating the discomfort the patients feel based on auricle position change during the body temperature measurement, and it records the values for the duration of the body temperature measurement process and body temperature. This form was developed by the researchers. The score range of the "Visual Comparison Scale" is between 0 and 10.
According to this scale, while "0" means "I do not feel discomforted", "10" means "I feel terribly discomforted". "Stop watch" was used to record whether there is a difference between the measurement processes in terms of duration.
To measure the body temperature in all the patients, only the Covidien brand tympanic membrane thermometer was used. Before the study was started, the Covidien brand tympanic membrane thermometer was calibrated and a pilot study was conducted with 15 people to assure the accuracy of the thermometer.
Intervention Firstly, patients selected with convenience sampling. In the sampling method, the order of the patients' enrollment to the emergency room was used. Then, patient's age, sex and presence of otitis media were recorded in the Personal Information Form.
After recording, measurements were carried out on the patients in the study firstly by not changing the position of the auricle. The duration was measured by stop watch and the results were recorded in the data form. The levels of patients' discomfort were evaluated by the "Visual Comparison Scale".
The measurement was then repeated after a minute, this time by changing the position of the auricle. The duration was measured for this position and the results were recorded in the data form. The levels of patients' discomfort were evaluated by the "Visual Comparison Scale". The auricle on the same side was used during both measurements.
Sample Size Calculation In order to determine the sample size, a pre-administration was conducted on a total of 15 adult patients. The collected data were subjected to a power analysis. The effect size was determined as d=0.3645, according to the evaluation that was conducted by using these data. To obtain 99% power at a level of α=0.05, it was determined that there must be 110 patient in the groups. When considering that there may be a loss of data in the study process, it was decided that the study should be conducted on a total of 143 participants.
Ethical Considerations Approval (number: 2015-106) was received for the study from the Scientific Ethics Board of University, Faculty of Nursing. Written permission was taken from the Chief Physician of the Hospital of University, Faculty of Medicine for conducting the study in the emergency department of the hospital, while written consent was received from patients themselves after information was provided about the purpose of the study.
Analysis The statistical analysis of the data obtained in the study was achieved using the Statistical Package for the Social Sciences (SPSS) 22.0. For analysis of the data, frequencies, percentages, means and standard deviations were calculated, and the significance of the difference between paired values was tested in order to investigate the effects of auricle position on measurement values. Additionally, systematic distributions of the data were examined with a Bland Altman plot which is used in repeated measurements based on positions. The results were interpreted in a 95% confidence interval and a level of significance of p<0.05.
The mean value taken from the measurements with the tympanic membrane thermometer was 36.99±0.48 in measurements by positioning the auricle, and 36.68±0.47 in measurements without positioning. The difference between the measurements obtained in two different positions was found as 0.31 0C. Accordingly, it was found that the difference between the values in two different measurement positions was noteworthy (t=15.12; p< 0.05).
While one of the researchers measured the temperature with the tympanic membrane thermometer, the other researcher measured the amount of time elapsed with a stopwatch and recorded it. The mean duration of measurement was 5.51 seconds (min: 3.5 max: 7.3) in the measurements made by positioning the auricle, and 4.42 seconds (min: 2.9 max: 7.6) in the measurements without positioning. Considering the difference between the durations of measurements made in two different positions ( =1.08±0.07) it was found that the difference was significant between the measurements with positioning and those without positioning (t=15.16; p< 0.05).
Table II. Measurement results according to pinna position and durations of the measurements taken in the comparison of the two positions.
Conclusion This article contributes the main finding that nurses should be change the position of the pinna while measuring the temperature with tympanic membrane thermometers. Placing the sensor tip of the thermometer into the ear canal and pulling the auricle allows easy access to the tympanic membrane by straightening the external canal and it reflected the core temperature accurately.
Utilization of tympanic membrane thermometers in measurement of body temperature is highly important and technique should be applied properly to obtain correct values in emergency department. In the light of the results we obtained in this study, in order to achieve accurate and reliable measurement values the auricle should be positioned correctly, and the ear canal should be straightened. This way, the tympanic membrane that receives blood via the external cerebral artery is placed straight ahead the infrared rays. This method of body temperature measurement should be included in the in-service training or nurses, as it is one of the jobs of nurses to measure body temperature.
The information in user manuals in Turkish about tympanic membrane thermometers should be updated to include the steps in the process of body temperature measurement, and nurses should use this method effectively. The information in the literature relative to nursing practices on measurements made with tympanic membrane thermometers should be updated. It was found that the measurements made by positioning the auricle did not require an extra application time and this application would not be an additional workload for the nurses. It was determined that body temperature measurement by placing auricle in position did not cause discomfort in patients. Studies about the accuracy and reliability of measurements made with tympanic membrane thermometers should be repeated on different samples and the results should be shared.
References
- Chaglla JSE, Celik N, Balachandran W. Measurement of Core Body Temperature Using Graphene-Inked Infrared Thermopile. Sensor 2018;18:3315-23. Doi: 10.3390/s18103315.
- Arslan GG, Eşer İ, Khorshıd L. Analysis of the effect of lying on the ear on body temperature measurement using a tympanic thermometer. Journal of Pakistan Medical Association 2011; 61:1065. Retrieved from http://jpma.org.pk/PdfDownload/3100.pdf.
- Erickson RS, Kirklin SK. Comparison of ear-based, bladder, oral, and axillary methods for core temperature measurement. Critical care medicine, 1993;21(10): 1528-1534.
- Yeoh WK, Lee JKW, Lim HY, Gan CW, Liang W, Tan KK. Re-visiting the tympanic membrane vicinity as core body temperature measurement site. PLoS ONE 2017; 2 (4): 1-21. Doi: 10.1371/journal.pone.0174120.
- Stavem, Saxholm, Smith-Erichsen, 1997
- Yaron M, Lowenstain SR, Koziol McLain J. Measuring the accuracy of the infrared tympanic thermometer. Journal of Emergency Medicine 1995;13:617-621. Doi: 10.1016/0736-4679(95)00065-i
Study design
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
- Model description
- a quasi-experimental design with a pre-test and a post-test.
| Arm | Type | Receives |
|---|---|---|
| experiment group | Experimental | Procedure: Body Temperature MeasurementsFirstly, patients selected with convenience sampling. In the sampling method, the order of the patients' enrollment to the emergency room was used. Then, patient's age, sex and presence of otitis media were recorded in the Personal Information Form. After recording, measurements were carried out on the patients in the study firstly by not changing the position of the auricle. The duration was measured by stop watch and the results were recorded in the data form. The levels of patients' discomfort were evaluated by the "Visual Comparison Scale". The measurement was then repeated after a minute, this time by changing the position of the auricle. The duration was measured for this position and the results were recorded in the data form. The levels of patients' discomfort were evaluated by the "Visual Comparison Scale". The auricle on the same side was used during both measurements. |
Who may qualify
- Ages
- 18 to 70 years
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (1 listed)
- The patients who were 18 years old or older, conscious, without communication issues, volunteers, not diagnosed with otitis media, who did not have a fever.
Key exclusion criteria (1 listed)
- havin fever, Being under the age of 18, not volunteers.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Body Temperature Measurementsmeasurements were carried out on the patients in the study firstly by not changing the position of the auricle. The duration was measured by stop watch and the results were recorded in the data form. The levels of patients' discomfort were evaluated by the "Visual Comparison Scale". The measurement was then repeated after a minute, this time by changing the position of the auricle. The duration was measured for this position and the results were recorded in the data form. | Procedure or surgery | experiment group |
Primary outcome
outcome1
Time frame: NOVEMBER 2016 JANUARY 2017
It was found in the comparison of two positions that there was a significant difference between the tympanic membrane thermometer measurements made by positioning the auricle and those without positioning
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 9 Jul 2020.
- Individual participant dataSharing planned: No. I have not IPD
Related trials for Body Temperature Changes
RecruitingObservational study
Familial Mediterranean Fever and Related Disorders: Genetics and Disease Characteristics
Familial Mediterranean Fever (FMF), Autoinflammation
Recruiting
Recovery After Fatigue in Young Athletes: Comparison Between TECAR Therapy and Cycle Ergometer"
Muscle Fatigue, Healthy Adult
RecruitingObservational study
Host and Parasite Factors That Influence Susceptibility to Malaria Infection and Disease During Pregnancy and Early Childhood in Ouelessebougou and Bamako, Mali
Malaria
RecruitingObservational study
Diagnosis and Management of Inflammatory and Infectious Diseases
Infection, Inflammation
Not yet recruiting
Rapid Cool: Heat Stroke Treatment
Hyperthermia
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
Questions about this trial
What is this clinical trial studying?
A study testing Body Temperature Measurements in people with Body Temperature Changes, run by Ege University.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 9 Jul 2020. Status can change between updates, so confirm with the study contact before making plans.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
outcome1 (time frame: NOVEMBER 2016 JANUARY 2017). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Jul 2020.