AzTrials
AzTrials

Energy ExpenditureNCT04491708

What is the Metabolic Intensity of Pilates

A study testing Pilates exercises in people with Energy Expenditure, run by Catholic University of Brasília.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Background: Pilates is a form of structured physical activity that is commonly used in rehabilitation settings and to improve muscular fitness, balance, and flexibility. Despite its popularity, it is not known whether the energy expenditure (EE) and oxygen consumption from Pilates sessions could also lead to metabolic… Read more about this study

Who is it for?
Ages 18 to 30 years, women onlyHealthy volunteers can take part
Conditions the study is for
Energy Expenditure
What is being tested?
Pilates exercises
Could I receive a placebo?
No, everyone receives an active treatment
How many people
18 participants
Where
No sites listed yet
Study dates
1 Jul 2015to 30 Jan 2016
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 30 years
  • Women only
  • Healthy volunteers accepted
  • Adult

Who may be able to join

  • Women aged up to 30 years;
  • Sedentary or irregularly active, as assessed by the International Physical Activity Questionnaire (IPAQ);
  • Not have any prior experience in Pilates exercises.

Who cannot join

  • Have any clinical or orthopedic conditions/disease;
  • Practitioner of any type of exercise.

About this study

Official title: What is the Metabolic Intensity of Pilates: An Analysis of the Energy Expenditure and Cardiovascular Markers of Intensity of Apparatus and Mat Pilates Sessions

Background: Pilates is a form of structured physical activity that is commonly used in rehabilitation settings and to improve muscular fitness, balance, and flexibility. Despite its popularity, it is not known whether the energy expenditure (EE) and oxygen consumption from Pilates sessions could also lead to metabolic fitness benefits. The aim of this study was to quantify the intensity and the EE during two different types of Pilates sessions (mat and apparatus). Methods: 18 healthy females (age: 22 ± 3 years; height: 1.6 ± 0.1cm; body mass: 61.0 ± 10.0 kg; body mass index: 21 ± 3 kg/cm2) performed two different sessions. Each session involved the performance of 15 different exercises. Oxygen consumption (VO2) was measured continuously and then converted to EE in Kcal/min. Blood lactate, heart rate (HR), and blood pressure (BP) were also measured. A repeated measures two-way ANOVA (time X group) determined differences between types.

Read the detailed description

The participants attended two half-hour Pilates exercise classes twice a week, for one month, to familiarize themselves with the exercises and to learn the 5 Pilates' principles. After the learning period, two experimental sessions were performed: a Mat Pilates session and a Reformer apparatus Pilates session. The order of each session was randomized and drawn beforehand. Each experimental session lasted about one and a half hours and the interval between the sessions was 48 hours. Participants were asked to not perform any exercise and to refrain from food or fluids except water eight hours prior to each experimental session. Prior to the start of the experimental sessions, participants received a standard breakfast of 321 kcal that was 76% (61 g) carbohydrate, 8% (6,7 g) protein, 16% (5,9) fat, provided by the study researchers. All sessions were conducted at the same time in the morning, and the room temperature (22°C) and humidity (40-50%) were controlled during the whole session.

Prior to the start of experimental sessions, participants rested in a supine position for 15 minutes. At the end of the 15 minutes, while still supine, measurements of BP and resting blood lactate were taken using standard laboratory procedures. Participants were then outfitted with a oxygen gas analyzer (Metalyzer 3b Cortex, Germany). Participants were connected by a mask, covering mouth and nose, to a digital gas flow analyzer. Standard calibration before every session was conducted according to the manufacturer's instructions.VO2 and HR were then simultaneously recorded for 5 minutes in a sitting position. At the end of the 5 minutes, the exercise session was started. VO2 and HR were monitored continuously throughout the session, while BP was assessed during rest intervals between exercises. At the end of the exercise session, BP and blood lactate were measured one time in a supine position in the post recovery time period. VO2 and HR were measured continuously for 5 minutes post session in a sitting position.

Being tested
Pilates exercises

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Pilates exercisesOther

    The participants attended two half-hour Pilates exercise classes twice a week, for one month, to familiarize themselves with the exercises and to learn the 5 Pilates' principles. After the learning period, two experimental sessions were performed: a Mat Pilates session and a Reformer apparatus Pilates session. The order of each session was randomized and drawn beforehand. Each experimental session lasted about one and a half hours and the interval between the sessions was 48 hours. Participants were asked to not perform any exercise and to refrain from food or fluids except water eight hours prior to each experimental session. Prior to the start of the experimental sessions, participants received a standard breakfast of 321 kcal that was 76% (61 g) carbohydrate, 8% (6,7 g) protein, 16% (5,9) fat, provided by the study researchers. All sessions were conducted at the same time in the morning, and the room temperature (22°C) and humidity (40-50%) were controlled during the whole session.

Study groups in NCT04491708
Study groupRoleWhat they receive
Apparatus PilatesExperimentalThe same Pilates exercises were performed during the Mat Pilates and Reformer apparatus sessions. For each exercise, one set of 10 repetitions was performed. Between each exercise, participants were allowed to rest for 2 minutes in a lying position. For each exercise in the Reformer apparatus, the number of springs used was defined during the familiarization sessions as the highest number of springs the participant could perform the 10 repetitions of the exercise with proper technique and following the 5 Pilates principles correctly. The exercises performed were (Stott 2003; Stott 2001): 1) Cat stretch; 2) Hip rolls; 3) Ab prep; 4) Breast stroke preps; 5) Hundred; 6) Breast stroke; 7) Half roll back; 8) Single leg stretch; 9) Slow double leg stretch; 10) Double leg stretch; 11) Double leg circle; 12) Scissors; 13) Roll over; 14) Teaser; 15) Spine stretch forward.
Receives: Other: Pilates exercises
Mat PilatesExperimentalThe same Pilates exercises were performed during the Mat Pilates and Reformer apparatus sessions. For each exercise, one set of 10 repetitions was performed. Between each exercise, participants were allowed to rest for 2 minutes in a lying position. For each exercise in the Reformer apparatus, the number of springs used was defined during the familiarization sessions as the highest number of springs the participant could perform the 10 repetitions of the exercise with proper technique and following the 5 Pilates principles correctly. The exercises performed were (Stott 2003; Stott 2001): 1) Cat stretch; 2) Hip rolls; 3) Ab prep; 4) Breast stroke preps; 5) Hundred; 6) Breast stroke; 7) Half roll back; 8) Single leg stretch; 9) Slow double leg stretch; 10) Double leg stretch; 11) Double leg circle; 12) Scissors; 13) Roll over; 14) Teaser; 15) Spine stretch forward.
Receives: Other: Pilates exercises

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Energy expenditure

    VO2 was measured continuously for both Mat and Reformer apparatus Pilates as described previously. Data were calculated on breath-by-breath intervals at rest and during exercise. The absolute EE in kilocalories per minute was estimated using a constant value of 5.05 kcal.L-1 O2, so the O2 values expressed in L/min were multiplied by 5.05. VO2 values in ml/min/kg were also considered for the analysis.

    Measured: 50 minutes

Secondary outcomes (3)
  1. Blood Lactate

    Capillary blood samples were collected from a fingertip before the first exercise and immediately after the last exercise of the Mat Pilates and Reformer apparatus experimental sessions. These samples were added into a 3mL eppendorf tube with sodium fluorite and this mixture was frozen to be further analyzed via spectrophotometry using a YSI 2300 STAT Plus (Yellow Springs Instrument, Yellow Springs, Ohio, USA).

    Measured: 10 minutes

  2. Heart rate

    HR was recorded continuously throughout the sessions using a POLAR RS800cx heart-rate monitor (Polar Electro, Kempele, Finland) as per manufacturers guidelines for sensor belt placement. The mean HR of each Pilates sessions was determined using the Polar Precision Performance software (version 5.40.172).

    Measured: 50 minutes

  3. Blood pressure

    BP was measured using a digital BP monitor (Microlife BP 3BTO-A, São Paulo, Brazil) on the left arm. BP was measured, when participants lied on a bed on supine position, before, during (in the rest intervals between exercises) and after the exercises in the post exercise. Both pressures, sistolic and diastolic, was assessed during the study period.

    Measured: 15 minutes

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted29 Jul 2020
  2. Study start1 Jul 2015
  3. Primary completion30 Dec 2015
  4. Study completion30 Jan 2016

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Basic science
Allocation
Randomised
Intervention model
Crossover
Masking
Single blind
Who is masked
Participant
Enrolment
18 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04491708
Sponsor's protocol ID
28657514.0.0000.0029
Status last verified
Aug 2020
First submitted
25 Jul 2020
Last updated
5 Aug 2020
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Wilmore JH, Parr RB, Ward P, Vodak PA, Barstow TJ, Pipes TV, Grimditch G, Leslie P. Energy cost of circuit weight training. Med Sci Sports. 1978 Summer;10(2):75-8.

    PubMed 692305

Questions about this trial

What is this clinical trial studying?

A study testing Pilates exercises in people with Energy Expenditure, run by Catholic University of Brasília.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 5 Aug 2020. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Energy expenditure (time frame: 50 minutes). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04491708, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 5 Aug 2020.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in