Prostate CancerNCT04565457
A Pilot Study Evaluating the Effect of 2D Antiscatter Grids on CBCT Image Quality
A study testing Research CBCT in people with Prostate Cancer and Head and Neck Cancers, run by University of Colorado, Denver at 2 sites in United States.
Trial summary
This is Pilot study that investigates the CBCT(Cone beam computed tomography) image quality improvement provided by the 2D antiscatter grid technology. The primary objective is to assess the improvement in tissue visualization in an observer study, which will be conducted in a blinded fashion. Read more about this study
- Who is it for?
- Ages 18 to 100 years
- Conditions the study is for
- Prostate Cancer, Head and Neck Cancers, Upper Abdomen Cancers
- What is being tested?
- Research CBCT
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 43 participants
- Where
- 2 sitesUnited States
- Study dates
- 21 Apr 2023to 28 May 2025
- Phase
- Interventional
- Are there results?
- Yes, posted in the registrySummary in the doctors' view
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 100 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Provision to sign and date the consent form.
- Stated willingness to comply with all study procedures and be available for the duration of the study.
- Be a male or female aged 18-100.
- Participants who will be treated or are currently being treated with CBCT-guided photon therapy for prostate or prostate-bed, abdomen head and neck, or pelvic cancers, or with image-guided proton therapy for prostate or prostate bed cancer.
Who cannot join
- Metallic implants in the CBCT scan volume, such as hip prostheses or spine stabilization hardware. Patients with pacemakers, defibrillators, or other implanted electronic devices. Dental implants, fillings, or fiducial markers may be acceptable, and the decision for inclusion/exclusion will be on a case-by-case basis, by reviewing prior CT images of the study candidate. Patient's prior CT images will be reviewed by the PI or the site PI.
- Patients who do not have the ability to lie still for the duration of his/her CBCT imaging and treatment should be excluded. If image artifacts in prior scans are deemed excessive, the patient will be excluded from the study.
- Known pregnancy. (Per SOC, a pregnancy test will be performed prior to CBCT scan on Day 1. At this time, women of child-bearing potential (WOCBP) will receive a pregnancy test to re-confirm eligibility).
- Women of child-bearing potential are described as:
- Age 55 or younger who have not had a negative pregnancy test within 3 days. This excludes patients who have had tubal ligation or are already post-menopausal.
Trial locations and contacts
2 sites in 1 country.
United States2 sites
University of Colorado Hospital
Aurora, Colorado, 80045
University of Florida Health Proton Therapy Institute
Jacksonville, Florida, 32206
About this study
This is Pilot study that investigates the CBCT(Cone beam computed tomography) image quality improvement provided by the 2D antiscatter grid technology. The primary objective is to assess the improvement in tissue visualization in an observer study, which will be conducted in a blinded fashion.
Read the detailed description
This is a single arm study, where all participants will be scanned with a CBCT system equipped with 2D antiscatter grid technology, referred to as research CBCT. Each participant will also be scanned with a standard clinical CBCT as part of their standard clinical care, which will serve as the baseline, or control. Thus, the image quality improvement in research CBCT will assessed with respect to standard clinical CBCT.
- Being tested
- Research CBCT
- Medical subject headings
- Prostatic Neoplasms, Head and Neck Neoplasms
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Research CBCTDevice
Each study participant will receive one additional CBCT scan, with 2D antiscatter grid in place. This is the only intervention in the study, referred as research CBCT scan, and it will be performed on one of the days during the participant's radiation treatment course. This additional research CBCT scan will be used strictly for the objectives of this study. It will not be used as part of the standard clinical care, such as imaging guidance of participant's radiation treatment or diagnostic purposes. To deliver participant's radiation treatment under CBCT guidance, a standard clinical CBCT scan will be acquired, as in standard clinical care protocols.
| Study group | Role | What they receive |
|---|---|---|
| Participants Scanned | Experimental | All participants will be scanned with a CBCT system equipped with 2D antiscatter grid technology, referred to as research CBCT. Each participant will also be scanned with a standard clinical CBCT as part of their standard clinical care, which will serve as the baseline, or control. Receives: Device: Research CBCT |
What is being measured
The primary outcome is the main question the study is designed to answer.
Ratio of Standard CBCT to Research CBCT HU Error in Photon Therapy Participants
Ratio of HU error for standard clinical CBCT (iteratively reconstructed) relative to research CBCT with 2D antiscatter grid in photon therapy participants. HU error was assessed in corresponding regions of interest, and the ratio was estimated using a linear mixed-effects model. A ratio greater than 1 would indicate higher HU error in standard CBCT than in research CBCT. A ratio less than 1 would indicate higher HU error in research CBCT than in standard CBCT.
Measured: At time of CBCT imaging session (Day 1)
Median Shift in Hounsfield Unit (HU) Error Between Standard CBCT and Research CBCT in Proton Therapy Participants
Median paired shift in Hounsfield Unit (HU) error between research CBCT and standard clinical CBCT scans in participants receiving proton radiation therapy. HU error was evaluated in corresponding regions of interest in paired scans. The Hodges-Lehmann estimate of the median shift and its 95% confidence interval were calculated, and paired differences were evaluated using a Wilcoxon signed-rank test.
Measured: At time of CBCT imaging session (Day 1)
Ratio of Artifact Amplitude Between Standard CBCT and Research CBCT in Photon Therapy Participants
Ratio of artifact amplitude between standard clinical CBCT (iteratively reconstructed) and research CBCT scans in participants receiving photon radiation therapy. Artifact amplitude was measured in corresponding regions of interest. The ratio of artifact amplitude between standard CBCT and research CBCT was estimated using a linear mixed-effects model. Ratio greater than 1 would indicate that standard CBCT has greater artifact amplitude than research CBCT.
Measured: At time of CBCT imaging session (Day 1)
Median Shift in Artifact Amplitude (Measured in Hounsfield Units) Between Standard CBCT and Research CBCT in Proton Therapy Participants
Median paired shift in Artifact Amplitude between research CBCT and standard clinical CBCT scans in participants receiving proton radiation therapy. Artifact Amplitude error was evaluated in corresponding regions of interest in paired scans. The Hodges-Lehmann estimate of the median shift and its 95% confidence interval were calculated, and paired differences were evaluated using a Wilcoxon signed-rank test.
Measured: At time of CBCT imaging session (Day 1)
Ratio of Contrast-To-Noise Ratio (CNR) Between Standard CBCT and Research CBCT in Photon Therapy Participants
Ratio of CNR between standard clinical CBCT and research CBCT scans in participants receiving photon radiation therapy. CNR was quantified in corresponding regions of interest in paired standard and research CBCT scans of each participant. The ratio of CNR between standard CBCT and research CBCT was estimated using a linear mixed-effects model.
Measured: At time of CBCT imaging session (Day 1)
Median Shift in Contrast to Noise Ratio (CNR) Between Standard CBCT and Research CBCT in Proton Therapy Participants
Median paired shift in CNR between research CBCT and standard clinical CBCT scans in participants receiving proton radiation therapy. CNR was evaluated in corresponding regions of interest in paired scans. The Hodges-Lehmann estimate of the median shift and its 95% confidence interval were calculated, and paired differences were evaluated using a Wilcoxon signed-rank test.
Measured: At time of CBCT imaging session (Day 1)
Secondary outcomes (1)
Accuracy of Automated Tissue Delineation in CBCT Images for Photon Therapy Participants. Difference in Dice Similarity Coefficient Between Research CBCT and Standard CBCT
Similarity between anatomical structures delineated by auto-segmentation software and expert observer contours in research CBCT and standard clinical CBCT images was evaluated using the Dice similarity coefficient. The pairwise difference in Dice coefficients between standard clinical CBCT and research CBCT images was calculated. Higher Dice coefficients indicate greater similarity between auto-segmented and expert-drawn contours and higher accuracy in automated tissue delineation.
Measured: At time of CBCT imaging session.
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted25 Sep 2020
- Study start21 Apr 2023
- Primary completion28 May 2025
- Study completion28 May 2025
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Posted resultsParticipant flow, outcome measures and adverse events reported by the sponsor.
- Other trials for Prostate CancerStudies of the same condition, open and under way.
- More trials run by University of Colorado, DenverThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Model description
- Single arm study
- Masking
- None (open label)
- Enrolment
- 43 participants (actual)
Sponsor and investigators
- Lead sponsor
- University of Colorado, Denver
- Sponsor type
- University, hospital or other
- Collaborators
- National Cancer Institute (NCI)
- Responsible party
- Sponsor
- Investigators
- Cem Altunbas, PhD, Principal investigator, University of Colorado, Denver
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04565457
- Sponsor's protocol ID
- 20-1684.cc
- Other IDs
- R01CA245270
- Status last verified
- Apr 2026
- First submitted
- 18 Sep 2020
- Last updated
- 6 May 2026
- Results posted
- Yes, on ClinicalTrials.gov
- Data monitoring committee
- Yes
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 6 May 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- A Pilot Study Evaluating the Effect of 2D Antiscatter Grids on CBCT Image Quality
- ClinicalTrials.gov ID
- NCT04565457
- Acronym / sponsor ID
- 20-1684.cc
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 43 participants (actual)
- Lead sponsor
- University of Colorado, DenverUniversity, hospital or other
- Collaborators
- National Cancer Institute (NCI)
- Study start
- 21 Apr 2023 (actual)
- Primary completion
- 28 May 2025 (actual)
- Study completion
- 28 May 2025 (actual)
- First posted
- 25 Sep 2020 (actual)
- Results
- Posted 6 May 2026
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
This is Pilot study that investigates the CBCT(Cone beam computed tomography) image quality improvement provided by the 2D antiscatter grid technology. The primary objective is to assess the improvement in tissue visualization in an observer study, which will be conducted in a blinded fashion.
Detailed description
This is a single arm study, where all participants will be scanned with a CBCT system equipped with 2D antiscatter grid technology, referred to as research CBCT. Each participant will also be scanned with a standard clinical CBCT as part of their standard clinical care, which will serve as the baseline, or control. Thus, the image quality improvement in research CBCT will assessed with respect to standard clinical CBCT.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
- Model description
- Single arm study
| Arm | Type | Receives |
|---|---|---|
| Participants Scanned | Experimental | Device: Research CBCTAll participants will be scanned with a CBCT system equipped with 2D antiscatter grid technology, referred to as research CBCT. Each participant will also be scanned with a standard clinical CBCT as part of their standard clinical care, which will serve as the baseline, or control. |
Who may qualify
- Ages
- 18 to 100 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (4 listed)
- Provision to sign and date the consent form.
- Stated willingness to comply with all study procedures and be available for the duration of the study.
- Be a male or female aged 18-100.
- Participants who will be treated or are currently being treated with CBCT-guided photon therapy for prostate or prostate-bed, abdomen head and neck, or pelvic cancers, or with image-guided proton therapy for prostate or prostate bed cancer.
Key exclusion criteria (5 listed)
- Metallic implants in the CBCT scan volume, such as hip prostheses or spine stabilization hardware. Patients with pacemakers, defibrillators, or other implanted electronic devices. Dental implants, fillings, or fiducial markers may be acceptable, and the decision for inclusion/exclusion will be on a case-by-case basis, by reviewing prior CT images of the study candidate. Patient's prior CT images will be reviewed by the PI or the site PI.
- Patients who do not have the ability to lie still for the duration of his/her CBCT imaging and treatment should be excluded. If image artifacts in prior scans are deemed excessive, the patient will be excluded from the study.
- Known pregnancy. (Per SOC, a pregnancy test will be performed prior to CBCT scan on Day 1. At this time, women of child-bearing potential (WOCBP) will receive a pregnancy test to re-confirm eligibility).
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Research CBCTEach study participant will receive one additional CBCT scan, with 2D antiscatter grid in place. This is the only intervention in the study, referred as research CBCT scan, and it will be performed on one of the days during the participant's radiation treatment course. This additional research CBCT scan will be used strictly for the objectives of this study. It will not be used as part of the standard clinical care, such as imaging guidance of participant's radiation treatment or diagnostic purposes. To deliver participant's radiation treatment under CBCT guidance, a standard clinical CBCT scan will be acquired, as in standard clinical care protocols. | Device | Participants Scanned |
Primary outcome
Ratio of Standard CBCT to Research CBCT HU Error in Photon Therapy Participants
Time frame: At time of CBCT imaging session (Day 1)
Ratio of HU error for standard clinical CBCT (iteratively reconstructed) relative to research CBCT with 2D antiscatter grid in photon therapy participants. HU error was assessed in corresponding regions of interest, and the ratio was estimated using a linear mixed-effects model. A ratio greater than 1 would indicate higher HU error in standard CBCT than in research CBCT. A ratio less than 1 would indicate higher HU error in research CBCT than in standard CBCT.
Median Shift in Hounsfield Unit (HU) Error Between Standard CBCT and Research CBCT in Proton Therapy Participants
Time frame: At time of CBCT imaging session (Day 1)
Median paired shift in Hounsfield Unit (HU) error between research CBCT and standard clinical CBCT scans in participants receiving proton radiation therapy. HU error was evaluated in corresponding regions of interest in paired scans. The Hodges-Lehmann estimate of the median shift and its 95% confidence interval were calculated, and paired differences were evaluated using a Wilcoxon signed-rank test.
Ratio of Artifact Amplitude Between Standard CBCT and Research CBCT in Photon Therapy Participants
Time frame: At time of CBCT imaging session (Day 1)
Ratio of artifact amplitude between standard clinical CBCT (iteratively reconstructed) and research CBCT scans in participants receiving photon radiation therapy. Artifact amplitude was measured in corresponding regions of interest. The ratio of artifact amplitude between standard CBCT and research CBCT was estimated using a linear mixed-effects model. Ratio greater than 1 would indicate that standard CBCT has greater artifact amplitude than research CBCT.
Median Shift in Artifact Amplitude (Measured in Hounsfield Units) Between Standard CBCT and Research CBCT in Proton Therapy Participants
Time frame: At time of CBCT imaging session (Day 1)
Median paired shift in Artifact Amplitude between research CBCT and standard clinical CBCT scans in participants receiving proton radiation therapy. Artifact Amplitude error was evaluated in corresponding regions of interest in paired scans. The Hodges-Lehmann estimate of the median shift and its 95% confidence interval were calculated, and paired differences were evaluated using a Wilcoxon signed-rank test.
Ratio of Contrast-To-Noise Ratio (CNR) Between Standard CBCT and Research CBCT in Photon Therapy Participants
Time frame: At time of CBCT imaging session (Day 1)
Ratio of CNR between standard clinical CBCT and research CBCT scans in participants receiving photon radiation therapy. CNR was quantified in corresponding regions of interest in paired standard and research CBCT scans of each participant. The ratio of CNR between standard CBCT and research CBCT was estimated using a linear mixed-effects model.
Median Shift in Contrast to Noise Ratio (CNR) Between Standard CBCT and Research CBCT in Proton Therapy Participants
Time frame: At time of CBCT imaging session (Day 1)
Median paired shift in CNR between research CBCT and standard clinical CBCT scans in participants receiving proton radiation therapy. CNR was evaluated in corresponding regions of interest in paired scans. The Hodges-Lehmann estimate of the median shift and its 95% confidence interval were calculated, and paired differences were evaluated using a Wilcoxon signed-rank test.
1 secondary outcome
Accuracy of Automated Tissue Delineation in CBCT Images for Photon Therapy Participants. Difference in Dice Similarity Coefficient Between Research CBCT and Standard CBCT
Time frame: At time of CBCT imaging session.
Results and safety
Loading the posted results from ClinicalTrials.gov…
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 6 May 2026.
- Posted resultsParticipant flow, baseline, all outcome measures and adverse events.
- Individual participant dataSharing planned: No
Related trials for Prostate Cancer
RecruitingPhase 1/2
Docetaxel and SX-682 in Recurrent/Metastatic Head and Neck Squamous Cell Carcinoma, Salivary Gland Carcinoma, and Advanced Prostate Cancer
Head and Neck Cancer, Head and Neck Squamous Cell Carcinoma
Active, not recruiting
Daily Adaptive Post-Prostatectomy With Stereotactic Ablative Radiotherapy in Patients With Prostate Cancer
Malignant Prostate Neoplasm
Enrolling by invitation
Use of Tracking Devices to Locate Abnormalities During Invasive Procedures
Adenocarcinoma, Prostate Neoplasms
RecruitingObservational study
Imaging Studies to Check the Local Response of Prostate Cancer to Radiation Therapy
Prostatic Neoplasms, Prostate Cancer
RecruitingPhase 1
A Study of LY4257496 in Participants With Cancer (OMNIRAY)
Breast Neoplasms, Colorectal Neoplasms
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Cem Altunbas, PhD principal investigator
University of Colorado, Denver
2 sites in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Research CBCT in people with Prostate Cancer and Head and Neck Cancers, run by University of Colorado, Denver at 2 sites in United States.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 6 May 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 2 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Yes. Results are posted in the registry (first posted 6 May 2026). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Ratio of Standard CBCT to Research CBCT HU Error in Photon Therapy Participants (time frame: At time of CBCT imaging session (Day 1)). The study lists 6 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 May 2026.