AzTrials
AzTrials

Temperature Change, BodyNCT04608565

Remote Biomonitoring (RBM) for Temperature Surveillance of Mothers and Newborns: Pre-clinical and Clinical Evaluation

A study testing Remote biomonitoring sensor device in people with Temperature Change, Body, run by St. John's Research Institute at 1 site in India.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Based on client needs and technological requirements, a wearable sensor device was designed and developed using principles of 'social innovation' design. The device underwent multiple iterations in product design and engineering based on user-feedback and then following pre-clinical testing, a techno-feasibility study… Read more about this study

Who is it for?
Ages 1 day to 7 daysHealthy volunteers can take part
Conditions the study is for
Temperature Change, Body
What is being tested?
Remote biomonitoring sensor device
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
250 participants
Where
1 siteIndia
Study dates
May 2014to Mar 2015
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 1 day to 7 days
  • All sexes
  • Healthy volunteers accepted
  • Child

Who may be able to join

  • Mothers 15-44 years
  • Neonates 1-7 days who were healthy and of normal weight from postnatal ward
  • Neonates 1-7 days who were stable from neonatal intensive care unit above 1500 grams

Who cannot join

  • Not applicable

Trial locations and contacts

1 site in 1 country.

India1 site
  • St. John's Research Institute

    Bangalore, Karnataka, 560034

Other trials in India

About this study

Official title: Remote Biomonitoring for Temperature Surveillance of Mothers and Newborns: Pre-clinical and Clinical Evaluation

Based on client needs and technological requirements, a wearable sensor device was designed and developed using principles of 'social innovation' design. The device underwent multiple iterations in product design and engineering based on user-feedback and then following pre-clinical testing, a techno-feasibility study and clinical trial were undertaken in a tertiary-care, teaching hospital in Bangalore, India. Clinical trial phases I and IIa {studies/pilot studies designed to demonstrate clinical efficacy or biological activity ('proof of concept' studies)} for evaluation of safety and efficacy were undertaken in the following sequence: first with healthy adult volunteers; then healthy mothers; healthy babies; stable babies in the Neonatal intensive care unit (NICU) and then a baby with morbidities. Time-stamped skin temperatures obtained at 5-minute intervals over a 1-hour period from the device secured on upper arms of mothers and abdomen of neonates were compared against readings from thermometers used routinely in clinical practice, radiant warmer and multimodal sensor

Read the detailed description

Study setting: St John's Medical College Hospital, Bangalore, a 1300-bedded, tertiary-care hospital with 2500 deliveries per annum and a Level-3 nursery that takes care of 1000 neonates (inborn: outborn ratio = 2:1) in the neonatal care intensive unit (NICU) annually, one-third of whom are low birth weight and one-fifth are preterm.

Choice of site of temperature measurement in adult and newborn: In the adult, the upper arm was selected for continuous monitoring. While in the newborn abdominal skin temperature was selected. In addition to being close to the liver, a metabolically-active organ facilitating a measurement close to the core temperature, it is also a non-invasive method that is steady, continuous, easy-to-use and comfortable for the infant.

Innovation Pathway: The USAID 2006 Innovation Pathway model was adopted and it incorporated four steps from research to field implementation - (1) priority-setting phase and product design (2) product development and proof-of-concept (3) product introduction and (4) field implementation.As part of step 1, the sub-steps of (a) problem identification (epidemiologic/ technological/ social/ financial, etc), (b) critical review of temperature measurement devices and other issues (temperature sensors or thermistors, core body temperature measurement issues, etc), and (c) determination of niche of this device vis-à-vis other devices through horizon scanning.

Epidemiologic burden of chief causes of maternal and neonatal mortality and morbidity were reviewed as a first step.A technological review revealed that the device to be strapped-on to the mother or newborn for vital sign detection had to be a medical-grade device with extremely high safety profile. Further, it had to remain functional in situations such as soiling or wetting by the newborn, and also continue to work in different areas with varying population densities as well as buildings. Several devices such as the ThermoSpot®, a temperature sensor tag and remote infrared-based instruments were evaluated. Social review revealed that a sensor being continually strapped on to the body for long periods was not dissimilar to that of talismans strapped around the arms of adults or around the necks/waists of children and might therefore not be too disagreeable to families. A financial review revealed that for the device to be used widely, especially by low-income populations, it would have to be a low-cost device. Implementation review focused on possible uptake and utilization of such a device in rural, urban and slum communities.

Conceptual framework: The conceptual framework for remote monitoring consisted of five components: (1) a low-cost, wearable sensor tag; (2) a gateway device acting as an ultra-low-power 'real-time' communication link; (3) piggy-backing on a commercial cellular communication network; (4) smart data analytics system; and (5) feedback loop to the care-giver or frontline health worker. This framework was to be ideated, designed, prototyped and developed into a Class A medical device with lowest risk level as per Medical Device Regulatory Authority of India bearing in mind that the end-product should enable tenets of good Quality of Care (QoC) namely effectiveness, timeliness, safety, people-centeredness and equity.

Requirements for components Two key requirements for the 'on-body' sensor were safety and accuracy. Given the fragility of the newborn skin, the device had to be hypoallergenic, burst/leak proof, cause minimal infections, and dissipate minimal heat or ultra-low power, non-ionizing electromagnetic radiation. nThe adhesive used to secure the device to the skin should similarly cause minimal 'medical adhesive-related skin injury' (MARSI), allergy or infections. Device accuracy was targeted to be +/-0.2°C in in-vitro conditions and +/-0.5°C in actual clinical practice. Other mechanical requirements for the device were: long battery-life up to 28 days (with sampling frequency of 5 minutes); robustness (without any malfunction on coming into contact with body fluids like sweat, blood, urine, faeces, etc);at least 'ingress protection class 67' (dust-proof and water-proof); human-centric and aesthetic design for non-intrusiveness over prolonged use; and ability to withstand mild shock or vibration; and that the device should not get re-set accidentally. There was also a requirement for the device to store data locally and communicate with a gateway device for onward transmission of data via the configured cellular network.

Product design and engineering: Based on the clinical requirements, a preliminary design was constituted and subsequent design choices underwent multiple iterations driven by technological capabilities and user reviews. The wearable sensor enclosures were pebble-shaped or coin-stack shaped with all the electronics embedded inside. A battery of tests (both mechanical and electrical) were undertaken to confirm device performance, robustness, and reliability. After several rounds of pre-testing, design optimization was achieved.

Prototype and Implementation: The details of the prototype sensor device are given elsewhere. Briefly, the sensor hardware platform, developed using a multi-layer printed circuit board, consisted of a microcontroller (MCU) with integrated Bluetooth 4.0 Low Energy (BLE), a 12-bit ADC {Analog to Digital Converter} (CC2540 from Texas Instruments), a NICU-grade temperature sensor with its analog front-end circuit, status LEDs {Light Emitting Diode}, power supply and RF {Radio-Frequency} balun {a electrical device that converts between a balanced and imbalanced signal} transmits filter and antenna for wireless communication over 2.4 GHz {gigahertz} ISM {Industrial Scientific and Medical} band. High-precision MF51E NTC {high precision negative temperature coefficient} thermistors were used for extremely accurate temperature measurements. An embedded Inverted F-antenna (IFA) with higher efficiency, longer range and a wider bandwidth than a chip antenna was used. It also had a very low tolerance resistor enabling a low power consumption during both active (150μA) as well as sleep (1μA) modes. The sensor hardware was programmable as per requirements. A 3-volt coin battery powered the device. A baby-friendly enclosure was made from medical-grade hypoallergenic plastics.

The sensor communicated with a gateway device (a smartphone or a Raspberry pi) that could subsequently relay the temperature data over a secured internet backbone provided by GPRS {General Packet Radio Service}/Wi-fi on to a centralized database for storage (web figure 3).

Phases of device testing: The planned phases of device testing were pre-clinical testing (in June 2013) and clinical trial phases I\& IIa {studies/pilot studies designed to demonstrate clinical efficacy or biological activity ('proof of concept' studies)} for evaluation of safety and efficacy in the following sequence: healthy adult volunteers (May 2014); healthy mothers (Jan-Feb 2015); healthy babies (Feb 2015); stable babies in the NICU (Feb-Mar 2015) and babies with morbidities such as hypoxic ischemic encephalopathy (Mar 2015). The results of the pre-clinical testing in the laboratory setting were published earlier. Briefly, the response time of the sensor device to attain thermal equilibrium with the surroundings was 4 minutes compared to 3 minutes observed with a precision-grade digital thermometer used as a reference standard. In terms of accuracy, the error was calculated to be within 0.1°C of the reference standard while using water-baths in the temperature range of 25°C to 40°C. The details of the clinical phase of testing are outlined below.

Seven free-living healthy adult volunteers (males = 2; females = 5), with no known morbidities, were the first phase participants over a 7-day period. All of them had the devices strapped with an arm band secured with Velcro® tape on to their left upper arms and were invited to contribute at least a minimum of 24 hours of observations accumulated from over one or more days and report any adverse events or side-effects they experienced. In parallel, they also noted down timed axillary temperature readings (at least 5 times in a 24-hour window) using a digital thermometer for paired comparisons.

Testing in healthy postnatal mothers (n=11) was first carried out amongst those with well babies in the postnatal ward and then amongst mothers (n=7) with neonates admitted in the NICU. The devices were secured on to their upper arms with arm band secured with Velcro® tape. Paired readings taken every 5 minutes over a 1-hour period with an axillary digital thermometer were compared against the readings of the sensor with its time stamp.

Testing among neonates was carried out in three different phases in all of which the devices were secured with cotton and micropore adhesive to the upper epigastrium. In the first phase, well-babies (n=3) in their early neonatal periods in the postnatal ward had their axillary temperature readings taken every 5 minutes over a 1-hour period with a digital thermometer and compared against the sensor readings. In the second phase, sick but stable neonates (n=10) from the NICU were recruited. They were under the radiant warmer with the temperature probe fixed on to the upper abdomen beside the sensor device and so the readings taken every 5 minutes over a 1-hour period from the warmer panel were compared against the sensor readings. But since all these babies had their temperatures maintained within a narrow normal range under the radiant warmer, we included one sick infant with hypoxic ischemic encephalopathy (HIE) due to birth asphyxia and who was on treatment with therapeutic whole-body cooling. This facilitated comparison of readings in the range of 33° to 34°C during the cooling and re-warming phases of the treatment. The radiant warmer probe readings taken every 5 minutes over a 1-hour period from the warmer panel were compared against the sensor readings.

Definitions Safety: An adverse event reporting and resolution protocol for the wearable sensor devices was instituted. This enabled capture of the number and severity of adverse events as well as the individual clinical management as also feedback for changes into device design. Adverse events to be recorded were: dermatitis, infection, thermal injury, radiation injury, device leak/burst and others.

Accuracy: Of the device was estimated by comparing temperatures recorded by the device against other measurements routinely used in clinical practice. For mothers and well-babies in postnatal wards, the comparisons were between the device temperatures versus axillary temperatures read from a digital thermometer (once readings stabilized after the beep - usually after 3 minutes); for newborns in NICU, the comparisons were between the time-stamped device temperatures versus skin probe temperatures obtained from the control panels of calibrated radiant warmers (Phoenix Medical Systems Private Limited, Chennai, India or Zeal Medical Ltd, Mumbai, India).

Statistical Analysis: Mean [+/-Standard deviation (S.D.)] was calculated for the paired sets of readings noted in mothers and newborns and the mean differences were obtained. Paired t-test was used for testing of significance between two different methods.

Ethics: Ethics approval for the study was obtained from the St John's Institutional Ethics Review Board (IERB #59/2011 dated 15 Mar 2011\&# 125/2014 dated 16 Aug 2014). The clinical trial was registered with the Clinical Trials Registry of India (CTRI/2015/05/005779). Informed consent was obtained from all participants/care-givers.

Being tested
Remote biomonitoring sensor device
Keywords
Newborns, Biomonitoring, Sensor, Device, Remote
Medical subject headings
Body Temperature Changes

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Remote biomonitoring sensor deviceDevice

    Same as described in arm descriptions. Safety was ensured by getting radiant warmer and multichannel probe examined and services by the biomedical engineering department; calibration certificates were obtained and these were used routinely in care of other neonates. An adverse event reporting and resolution protocol for the wearable sensor devices to capture number and severity of adverse events; individual clinical management and feedback for changes into device design. Adverse events recorded were: dermatitis, infection, thermal injury, radiation injury, device leak/burst and others.

Study groups in NCT04608565
Study groupRoleWhat they receive
Remote biomonitoring sensor deviceOther250 readings for a power of 80% and to detect a 5% difference in measurements with 95% confidence interval from mothers and newborns was ascertained. Once 3 probes were strapped (radiant warmer, RBM device and multichannel), a waiting period of 10 minutes for temperature stabilization was given. First RBM device \& multichannel probe provided readings continuously (every few seconds); Then radiant warmer probe and manual thermometer readings were taken every 15 minutes for 5 timings: 0, 15, 30, 45 and 60 minutes. Participant safety for newborns was ensured following routine appropriate care protocols.
Receives: Device: Remote biomonitoring sensor device

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Design, development and testing of a wearable sensor device for remote biomonitoring (RBM) of body temperatures in mothers and newborns

    We describe the design, development and testing of a wearable sensor device for remote biomonitoring (RBM) of body temperatures in mothers and newborns in southern India.

    Measured: May 2014-Mar 2015

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted29 Oct 2020
  2. Study startMay 2014
  3. Primary completionMar 2015
  4. Study completionMar 2015

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
250 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04608565
Sponsor's protocol ID
StJohnRI
Status last verified
Oct 2020
First submitted
19 Oct 2020
Last updated
29 Oct 2020
Results posted
No
Data monitoring committee
No
Individual data sharing
No

Publications

  • Varkey P, Horne A, Bennet KE. Innovation in health care: a primer. Am J Med Qual. 2008 Sep-Oct;23(5):382-8. doi: 10.1177/1062860608317695.

    PubMed 18820143
  • Christensen CM, Bohmer R, Kenagy J. Will disruptive innovations cure health care? Harv Bus Rev. 2000 Sep-Oct;78(5):102-12, 199.

    PubMed 11143147
  • Say L, Chou D, Gemmill A, Tuncalp O, Moller AB, Daniels J, Gulmezoglu AM, Temmerman M, Alkema L. Global causes of maternal death: a WHO systematic analysis. Lancet Glob Health. 2014 Jun;2(6):e323-33. doi: 10.1016/S2214-109X(14)70227-X. Epub 2014 May 5.

    PubMed 25103301
  • Million Death Study Collaborators; Bassani DG, Kumar R, Awasthi S, Morris SK, Paul VK, Shet A, Ram U, Gaffey MF, Black RE, Jha P. Causes of neonatal and child mortality in India: a nationally representative mortality survey. Lancet. 2010 Nov 27;376(9755):1853-60. doi: 10.1016/S0140-6736(10)61461-4. Epub 2010 Nov 12.

    PubMed 21075444
  • Yilmaz T, Foster R, Hao Y. Detecting vital signs with wearable wireless sensors. Sensors (Basel). 2010;10(12):10837-62. doi: 10.3390/s101210837. Epub 2010 Dec 2.

    PubMed 22163501
  • Ramdorai A, Herstatt C. Frugal innovation in healthcare: how targeting low-income markets leads to disruptive innovation. Springer International Publishing Switzerland. 2015

  • Registrar General of India. Sample Registration System Bulletin. Vol 49, No. 1. New Delhi, India: Government of India. 2014

  • Chen W, Dols S, Oetomo SB, et al. Monitoring body temperature of newborn infants at neonatal intensive care units using wearable sensors. BodyNets'2010, September 10-12, 2010, Corfu Island, Greece.

  • Smith J. Methods and devices of temperature measurement in the neonate: a narrative review and practice recommendations. Newborn & Infant Nursing Reviews 2014: 64-71

  • USAID. Report to Congress: Health-Related Research and Development Activities at USAID (HRRD), May 2006

  • Government of India. The Medical Devices Regulation Bill, 2006 (No XX of 2006). Department of Science & Technology, New Delhi.

  • Thyssen JP, Menne T. Metal allergy--a review on exposures, penetration, genetics, prevalence, and clinical implications. Chem Res Toxicol. 2010 Feb 15;23(2):309-18. doi: 10.1021/tx9002726.

    PubMed 19831422
  • Lund, C. Medical Adhesives in the NICU. Newborn & Infant Nursing Reviews 2014: 160-165

  • Rao H, Saxena D, Kumar S, et al. Low power remote neonatal temperature monitoring device. 7th International Conference on Biomedical Electronics and Devices (BioDevices 2014). 3-6 March 2014, Angers, France.

  • Yock P. Needs-based innovation: the biodesign process. BMJ Innov 2015;1:3

Questions about this trial

What is this clinical trial studying?

A study testing Remote biomonitoring sensor device in people with Temperature Change, Body, run by St. John's Research Institute at 1 site in India.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 29 Oct 2020. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in India. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Design, development and testing of a wearable sensor device for remote biomonitoring (RBM) of body temperatures in mothers and newborns (time frame: May 2014-Mar 2015). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04608565, which also lists 20 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 29 Oct 2020.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in