Comparison of Laser Speckle Contrast Imaging and Laser Doppler Imaging

A study testing Iontophoresis and Stepwise occlusion in people with Microcirculation, run by Maasstad Hospital at 1 site in Netherlands.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The microcirculation plays a fundamental role in metabolic reactions and has been shown as an essential determinant in many clinical scenarios such as shock states, chronic and cardio-metabolic diseases. Microcirculation can be assessed directly using laser-based techniques and intravital microscopes. Read more about this study

Who is it for?
Ages 18 to 50 yearsHealthy volunteers can take part
Conditions the study is for
Microcirculation
What is being tested?
Iontophoresis and Stepwise occlusion
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
15 participants
Where
1 siteNetherlands
Study dates
10 Dec 2018to 17 Dec 2018
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 50 years
  • All sexes
  • Healthy volunteers accepted
  • Adult

Who may be able to join

  • Should not have any disease at the time of procedure (including flu)
  • Should not have any chronic disease
  • Should not be under any medication
  • Should not be smoker or ex-smoker
  • Should not drink coffee or eat meal in two hours before the procedure
  • Should not have an allergy to sodium-nitroprusside

Who cannot join

  • Volunteer who does not meet any of the criteria above
  • <18 years old
  • Pregnant
  • Refusal to participate in the study or demand to end study for any reason
  • Hypersensitivity to sodium nitroprusside
  • Broken or damaged skin surfaces
  • Electrically-sensitive implanted devices such as cardiac pacemakers
  • Maastad Ziekenhuis employers or collegues

Trial locations and contacts

1 site in 1 country.

Netherlands1 site
  • Maasstad Ziekenhuis

    Rotterdam, South Holland, 3007AC

Other trials in Netherlands

About this study

The microcirculation plays a fundamental role in metabolic reactions and has been shown as an essential determinant in many clinical scenarios such as shock states, chronic and cardio-metabolic diseases. Microcirculation can be assessed directly using laser-based techniques and intravital microscopes. When combined with provocation tests, microvascular monitorization can be used to assess microvascular function.

Laser-based techniques are consist of two different methods named laser doppler imaging (LDI), laser speckle contrast imaging (LSCI). LSCI is a technique based on speckle contrast analysis that provides an index of blood flux. No need for skin contact, continuous and real-time assessment of the microcirculation led the LSCI to be broadly used in clinical practice. LDI is also a non-invasive diagnostic method used to measure the blood flux of tissue. The technique is based on measuring the doppler shift induced by moving red blood cells to the illuminating coherent light. Iontophoresis is one of the most commonly used provocation tests to study the endothelium in terms of endothelium-dependent and endothelium-independent vasodilation. Simultaneously with LDI and LSCI are used to follow and assess the skin blood flux during iontophoresis. Therefore, it provides a state to make a comparison between two different laser-based techniques in terms of flux characteristics.

The accurate assessment of burn depth is a critical step in the management of the burn-injured patient. Currently, LDI is the most widely used non-invasive measurement tool for assessing burn wounds and the only technique approved by the U.S. Food and Drug Administration. However, the LDI device is rather costly, cumbersome, and has a poor spatial resolution. LSCI measures perfusion in a similar way, but it provides high-quality images with a much higher spatial resolution. In addition, LSCI is much quicker, maneuverable, and able to assess larger skin areas. In order to use the LSCI technique in the clinical practice of burn-injured patients, as a first step, the linearity of LDI and LSCI should be shown. In this study, we aimed to compare LSCI and LDI with iontophoresis and stepwise occlusion technique. So, we will test the linearity of devices over a large range of blood flux values.

Read the detailed description

Measurements of microcirculation were initiated upon the ethical consent was approved. 15 healthy volunteer were included in the study. All volunteers were asked for the existence of any symptoms for the on-going disease like flu, infectious disease, and chronic disease (Diabetes, hypertension, rheumatologic disorders, epileptic disorders, etc.). Once the volunteer met inclusion criteria, he/she became eligible for study. Volunteers were advised to beware from food and drink for at least two hours before measurement. Also, they were advised to come at least two hours after big meals like lunch or dinner. All the volunteers were evaluated at the same position (sitting and hand at heart level), room and temperature to provide equal standards. The volunteer had rest for at least 30 minutes in a semi-recumbent and extending leg position. The room temperature was 24-26C and checked with a thermometer intermittently. The door was closed to prevent air movement. Lights were switched off, and the curtains were closed to prevent the effect of light on devices. Once all the environmental conditions met, two investigators evaluated the volunteer. One investigator checked the volunteer's blood pressure, temperature, and heart rate.

A vacuum pillow was used to hold the arm stable during the procedure. Two different devices (laser speckle contrast imaging (LSCI) and laser doppler imaging (LDI)) were ready next to the volunteer. An appropriate intact skin area, inner side of the forearm were used for the investigation and both electrodes were attached. The skin surface was cleaned with alcohol or deionized water to remove remnants of cosmetics and creams with low conductivity. This helped to prevent spots with high current density that may result in local burns and non-specific vascular reactions. After peeling off the protective tape layer on the bottom of the Drug Delivery Electrode, the electrode was firmly attached to the skin. The Dispersive Electrode was placed approximately 10-15 cm from the Drug Delivery Electrode. Power supply was connected by attaching the electrodes to the leads. After lifting the lid of the Drug Delivery Electrode using the pointed tab, tip of the syringe was slided under the lid of the Drug Delivery Electrode and the Drug Delivery Chamber was filled with approximately 0.5 mL of a 10 mg/ml SNP solution. The drug was then delivered using cathodal iontophoresis for 1 minute with a current strength of 200 µA. The LDI and LSCI instruments are positioned so they can alternately measure the delivery site. Basal perfusion was measured with both instruments before starting iontophoresis. Subsequently, iontophoresis was started and measurements are made alternating between the two instruments. Therefore, we would be able to compare both devices in terms of supra-baseline flux values. When all measurements were finished, the electrodes removed from the patient and the Drug Delivery Electrode and the Dispersive Electrode was removed.

The second part of the study was performed as step-wise occlusion. The arm which was not used for iontophoresis test was used for step-wise occlusion. The baseline blood flux was followed for 2 minutes by LDI and LSCI. After 2 minutes, the upper arm was occluded for 30 seconds with a pneumatic cuff up to 50 mmHg, 80 mmHg, 110 mmHg, 140 mmHg, and 170 mmHg. Between each part, the volunteer had rest for 5 minutes to let the blood flux to turn the baseline. Once reaching to the planned pressure, LSCI and LDI devices were alternately be used to record blood flux. Therefore, we were able to compare both devices in terms of sub-baseline flux values.

All data were recorded in 2 external electronic storage, and the names of the volunteers were coded with numbers. Only main investigator was aware of who corresponds to which number. Results of Perimed and Moore Devices were analyzed with the software PIMsoft 1.5 (Perimed AB, Järfälla, Sweden), MoorLDI2-BI Burn's Software Version 4.0, respectively. Two investigators performed the analysis. If one investigator made the analysis, the other checked the results, as well.

Being tested
Iontophoresis, Stepwise occlusion
Keywords
microcirculation, laser speckle contrast imaging, laser doppler perfusion imaging, iontophoresis, comparison, flux

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • IontophoresisDevice

    By using the PeriIont (Perimed, Jarfalla, Sweden) device, 0.5 mL of a 10 mg/ml Sodium nitroprusside solution was used transdermally and ionised with a current strength of 200 µA for 1 minute.

  • Stepwise occlusionOther

    The upper arm was occluded for 30 seconds with a pneumatic cuff up to 50 mmHg, 80 mmHg, 110 mmHg, 140 mmHg, and 170 mmHg. The volunteer had rest for 5 minutes between each occlusion procedure.

Study groups in NCT04660162
Study groupRoleWhat they receive
Arm-1: Laser speckle contrast imagingExperimental(Perimed AB, Järfälla, Sweden)
Receives: Device: Iontophoresis; Other: Stepwise occlusion
Arm-2: Laser Doppler perfusion imagingExperimental(Moor Instruments, Devon, UK)
Receives: Device: Iontophoresis; Other: Stepwise occlusion

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Comparison of Laser Speckle Contrast Imaging and Laser Doppler Imaging

    Blood flux values of Laser Speckle Contrast Imaging device (Perimed AB, Järfälla, Sweden) and Laser Doppler Imaging device (Moor Instruments, Devon, UK) will be measured in a wide range of blood flux values and an equation formula will be described

    Measured: 60 minutes

Secondary outcomes (2)
  1. Creating common unit for Laser Speckle Contrast Imaging and Laser Doppler Imaging

    Blood flux units will be measured and A new common and universal unit for laser based tecniques will be reported

    Measured: 60 minutes

  2. Creating common color map for Laser Speckle Contrast Imaging and Laser Doppler Imaging

    A new universal color code that is used by both Laser Doppler perfusion imaging and Laser speckle contrast imaging will be created based on the equation formula

    Measured: 60 minutes

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted9 Dec 2020
  2. Study start10 Dec 2018
  3. Primary completion17 Dec 2018
  4. Study completion17 Dec 2018

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Screening
Allocation
Randomised
Intervention model
Sequential
Masking
None (open label)
Enrolment
15 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04660162
Sponsor's protocol ID
NL65747.101.18
Acronym
LACOM
Status last verified
Mar 2023
First submitted
22 Nov 2020
Last updated
17 Mar 2023
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided

Publications

  • Sakr Y. Techniques to assess tissue oxygenation in the clinical setting. Transfus Apher Sci. 2010 Aug;43(1):79-94. doi: 10.1016/j.transci.2010.05.012. Epub 2010 Jun 17.

    PubMed 20692624
  • Briers JD. Laser Doppler, speckle and related techniques for blood perfusion mapping and imaging. Physiol Meas. 2001 Nov;22(4):R35-66. doi: 10.1088/0967-3334/22/4/201.

    PubMed 11761081
  • Tew GA, Klonizakis M, Crank H, Briers JD, Hodges GJ. Comparison of laser speckle contrast imaging with laser Doppler for assessing microvascular function. Microvasc Res. 2011 Nov;82(3):326-32. doi: 10.1016/j.mvr.2011.07.007. Epub 2011 Jul 22.

    PubMed 21803051
  • Stewart CJ, Frank R, Forrester KR, Tulip J, Lindsay R, Bray RC. A comparison of two laser-based methods for determination of burn scar perfusion: laser Doppler versus laser speckle imaging. Burns. 2005 Sep;31(6):744-52. doi: 10.1016/j.burns.2005.04.004.

    PubMed 16129229
  • Millet C, Roustit M, Blaise S, Cracowski JL. Comparison between laser speckle contrast imaging and laser Doppler imaging to assess skin blood flow in humans. Microvasc Res. 2011 Sep;82(2):147-51. doi: 10.1016/j.mvr.2011.06.006. Epub 2011 Jul 1.

    PubMed 21745482
  • Cordovil I, Huguenin G, Rosa G, Bello A, Kohler O, de Moraes R, Tibirica E. Evaluation of systemic microvascular endothelial function using laser speckle contrast imaging. Microvasc Res. 2012 May;83(3):376-9. doi: 10.1016/j.mvr.2012.01.004. Epub 2012 Jan 31.

    PubMed 22326551
  • Tesselaar E, Sjoberg F. Transdermal iontophoresis as an in-vivo technique for studying microvascular physiology. Microvasc Res. 2011 Jan;81(1):88-96. doi: 10.1016/j.mvr.2010.11.002. Epub 2010 Nov 9.

    PubMed 21070791
  • Wearn C, Lee KC, Hardwicke J, Allouni A, Bamford A, Nightingale P, Moiemen N. Prospective comparative evaluation study of Laser Doppler Imaging and thermal imaging in the assessment of burn depth. Burns. 2018 Feb;44(1):124-133. doi: 10.1016/j.burns.2017.08.004. Epub 2017 Oct 9.

    PubMed 29032974
  • Iredahl F, Lofberg A, Sjoberg F, Farnebo S, Tesselaar E. Non-Invasive Measurement of Skin Microvascular Response during Pharmacological and Physiological Provocations. PLoS One. 2015 Aug 13;10(8):e0133760. doi: 10.1371/journal.pone.0133760. eCollection 2015.

    PubMed 26270037
  • Ince C. The microcirculation is the motor of sepsis. Crit Care. 2005;9 Suppl 4(Suppl 4):S13-9. doi: 10.1186/cc3753. Epub 2005 Aug 25.

    PubMed 16168069
  • Klijn E, Den Uil CA, Bakker J, Ince C. The heterogeneity of the microcirculation in critical illness. Clin Chest Med. 2008 Dec;29(4):643-54, viii. doi: 10.1016/j.ccm.2008.06.008.

    PubMed 18954699

Questions about this trial

What is this clinical trial studying?

A study testing Iontophoresis and Stepwise occlusion in people with Microcirculation, run by Maasstad Hospital at 1 site in Netherlands.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 6 inclusion and 8 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 17 Mar 2023. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Netherlands. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Comparison of Laser Speckle Contrast Imaging and Laser Doppler Imaging (time frame: 60 minutes). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04660162, which also lists 11 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 17 Mar 2023.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in