AzTrials
AzTrials

Post ICU RehabilitationMONIREANCT04661423

Use of RDS MultiSense® in Post-ICU Patients in the COVID-19 Era

A study testing Remote Automated Monitoring System in people with Post ICU Rehabilitation, run by IHU Strasbourg at 2 sites in France.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

In this clinical study, the investigators will compare vital parameters measurements obtained using continuous data from reference monitors and continuous wireless MultiSense® monitoring patch in 60 post-ICU (Intensive Care Unit) patients and over 7 days. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Post ICU Rehabilitation
What is being tested?
Remote Automated Monitoring System
Could I receive a placebo?
No, everyone receives an active treatment
How many people
60 participants
Where
2 sitesFrance
Study dates
2 Sep 2021to 2 Mar 2025
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Man or woman over 18 years old.
  • Patient previously cared in an ICU for severe COVID-19 pneumonia, COVID-related condition or similar neurological compromise necessitating post-ICU rehabilitation
  • Negative respiratory SARS-CoV-2 (Severe Acute Respiratory Syndrome-Corona Virus-2) samples
  • Patient admitted in a post-ICU rehabilitation unit with an expected length of stay > 5 days
  • Patient able to receive and understand information related to the study and give written informed consent.
  • OR If the patient is not capable, presence of a next of kin able to receive and understand information related to the study and give written informed consent for the patient
  • Patient authorizing the treatment of their personal data collected during the study (box checked in the consent form)
  • Patient affiliated to the French social security system.

Who cannot join

  • Patient with a skin disease that would preclude the use of an adhesive.
  • Patient with an implantable device such as a pacemaker
  • Pregnant or lactating patient.
  • Patient in exclusion period (determined by a previous or a current study).
  • Patient under guardianship or trusteeship.
  • Patient under the protection of justice.

Trial locations and contacts

2 sites in 1 country.

France2 sites
  • Anesthesia Department, Central Hospital

    Nancy, 54000

  • Anesthesia, Critical Care & Perioperative Medicine, Hautepierre

    Strasbourg, 67000

Other trials in France

About this study

In this clinical study, the investigators will compare vital parameters measurements obtained using continuous data from reference monitors and continuous wireless MultiSense® monitoring patch in 60 post-ICU (Intensive Care Unit) patients and over 7 days.

Read the detailed description

The MultiSense® strip is a unique, band aid-sized, clinical signal quality, connected strip for real-time monitoring of cardio-respiratory parameters. The MultiSense® strip measures in real-time, remotely and continuously 11 clinical key-indicators by being attached to the patient thorax: ECG trace, heart rate, oxygen saturation (SpO2), respiratory rate and relative respiration depth, pulse transit time, plethysmographic trace, perfusion index, skin temperature, physical activity and body position. Designed to be worn continuously for at least seven days, the patient can keep the patch during his sleep or in the shower.

The aim of this study is to determine the quality of measurements of clinical signs provided by MultiSense® strip in comparison to measurements made with conventional medical devices in the hospital setting, in terms of accuracy, connectivity, generation of artifactual data and stability of data transmission. The study population includes 60 patients transferred to post-ICU units for a minimum of 5 days. Once in the post-ICU unit, the MultiSense® strip will be attached on patient's thorax. The monitoring will last between 5 to 7 days.

Being tested
Remote Automated Monitoring System
Keywords
Vital signs, Connected device, real-time monitoring, post-ICU, cardio-respiratory monitoring

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Remote Automated Monitoring SystemOther

    The patient will be monitored with conventional monitoring devices as well as the MultiSense patch.

Study groups in NCT04661423
Study groupRoleWhat they receive
Remote Automated Monitoring SystemExperimentalMultiSense® strip will be attached on patient's thorax. The monitoring will last between 5 and 7 days during the post-ICU hospitalization, at rest and during rehabilitation exercises.
Receives: Other: Remote Automated Monitoring System

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Determination of the quality of measurements of clinical signs provided by MultiSense® strip in comparison to measurements made with conventional medical devices in the hospital setting, in terms of accuracy.

    Accuracy is defined as an average measurement variation less than 3.5 percent or 5 percent of the mean value, depending on the variable with respect to the reference standard.

    Measured: from patch placement to hospital discharge, assessed up to 7 days

  2. Determination of the quality of measurements of clinical signs provided by MultiSense® strip in comparison to measurements made with conventional medical devices in the hospital setting, in terms of connectivity.

    Connectivity is defined as a time-wise ratio of missing versus total signal less than 20 percent.

    Measured: from patch placement to hospital discharge, assessed up to 7 days

  3. Determination of the quality of measurements of clinical signs provided by MultiSense® strip in comparison to measurements made with conventional medical devices in the hospital setting, in terms of generation of artifactual data.

    The generation of artefact data is defined as a percentage of outlier data less than 10 percent.

    Measured: from patch placement to hospital discharge, assessed up to 7 days

  4. Determination of the quality of measurements of clinical signs provided by MultiSense® strip in comparison to measurements made with conventional medical devices in the hospital setting, in terms of stability of data transmission.

    Data transmission stability is defined as a data transmission rate equal to or greater than 80 percent.

    Measured: from patch placement to hospital discharge, assessed up to 7 days

Secondary outcomes (7)
  1. Usability of a data acquisition patch by health care providers (HCPs) in the setting of post-ICU, rehabilitation unit assessed via a questionnaire.

    Descriptive determination of user-friendliness, comprehensibility and ease of placement, connection and removal of the data acquisition patch by healthcare providers.

    Measured: At hospital discharge, up to 7 days after the patch placement

  2. User experience of post-ICU rehabilitation patients with the continuous use of the adhesive data acquisition patch during remote monitoring assessed via a patient's final questionnaire.

    Descriptive determination of user experience and practicalities associated with wearing the data acquisition patch (e.g. portability, duration of skin adhesion, anticipated detachment, interference with activities and stigma perception).

    Measured: At hospital discharge, up to 7 days after the patch placement

  3. Assess patients' tolerability to prolonged use of an adhesive patch during remote monitoring.

    Number of unexpected local and distant events attributable to the use of the adhesive data acquisition patch

    Measured: From patch placement to its removal (up to 7 days)

  4. Assess the correlation between body temperature and skin temperature

    Correlation between the body temperature measured with a standard device and the skin temperature measured with the remote data acquisition device.

    Measured: From patch placement to its removal (up to 7 days)

  5. Assess the ability of the patch to detect and signal the clinically confirmed excursions of heart rate (high and low) outside predefined thresholds

    Non-inferiority of the number of clinically confirmed alerts observed with the patch compared to those signalled by the conventional devices, and difference in the number of false positive excursions.

    Measured: From patch placement to its removal (up to 7 days)

  6. Assess the ability of the patch to detect and signal the clinically confirmed excursions of SpO2 (low) outside predefined thresholds

    Non-inferiority of the number of clinically confirmed alerts observed with the patch compared to those signalled by the conventional devices, and difference in the number of false positive excursions.

    Measured: From patch placement to its removal (up to 7 days)

  7. Assess the ability of the patch to detect and signal the clinically confirmed excursions of respiratory rate (high and low) outside predefined thresholds

    Non-inferiority of the number of clinically confirmed alerts observed with the patch compared to those signalled by the conventional devices, and difference in the number of false positive excursions.

    Measured: From patch placement to its removal (up to 7 days)

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted10 Dec 2020
  2. Study start2 Sep 2021
  3. Primary completion2 Mar 2025
  4. Study completion2 Mar 2025

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
60 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04661423
Sponsor's protocol ID
20-004
Acronym
MONIREA
Status last verified
Apr 2025
First submitted
7 Dec 2020
Last updated
1 May 2025
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Pamuk K, Turan N. The effect of light on sleep quality and physiological parameters in patients in the intensive care unit. Appl Nurs Res. 2022 Aug;66:151607. doi: 10.1016/j.apnr.2022.151607. Epub 2022 Jun 26.

    PubMed 35840273

Questions about this trial

What is this clinical trial studying?

A study testing Remote Automated Monitoring System in people with Post ICU Rehabilitation, run by IHU Strasbourg at 2 sites in France.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 8 inclusion and 6 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 1 May 2025. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 2 sites in France. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Determination of the quality of measurements of clinical signs provided by MultiSense® strip in comparison to measurements made with conventional medical devices in the hospital setting, in terms of accuracy. (time frame: from patch placement to hospital discharge, assessed up to 7 days). The study lists 4 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04661423, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 1 May 2025.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.