AzTrials
AzTrials

HemodialysisNCT04746391

Impact of Clotting on Dialyzer Efficiency

A study testing Dialyzer type and Dialysis duration in people with Hemodialysis and Coagulation, run by University Hospital, Ghent at 1 site in Belgium.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Coagulation within the dialyzer membrane fibres is an obvious biological sign of bio-incompatibility. To avoid clotting during extracorporeal treatment, an anticoagulant is added to the circuit, resulting in an increased risk for bleeding complications. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Hemodialysis, Coagulation
What is being tested?
Dialyzer type and Dialysis duration
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
10 participants
Where
1 siteBelgium
Study dates
19 May 2021to 31 Jul 2021
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • 18 years or older
  • experienced stable dialysis sessions during the last 4 weeks
  • double needle/lumen well-functioning vascular access

Who cannot join

  • known coagulation disorder
  • active inflammation
  • malignancy

Trial locations and contacts

1 site in 1 country.

Belgium1 site
  • Ghent University Hospital - Nephrology

    Ghent, 9000

Other trials in Belgium

About this study

Official title: Assessment of a Relation Between Dialyzer Clearance and Clotting in Hemodialyzer

Coagulation within the dialyzer membrane fibres is an obvious biological sign of bio-incompatibility. To avoid clotting during extracorporeal treatment, an anticoagulant is added to the circuit, resulting in an increased risk for bleeding complications. In addition, there is evidence that a substantial number of fibers can become blocked before this is reflected in routinely observed parameters, or in termination of the dialysis session. Little is known about the impact of such subclinical clotting on dialyzer performance in terms of solute clearance. Membrane clogging may influence both the diffusive and convective transport characteristics of the dialyzer membrane before leading to complete dialyzer clotting. In 2018, we described a method to objectively count the number of blocked fibres inside a dialyzer using a micro-CT scanning technique. In the present trial, we use this method to assess the number of open fibers post dialysis, and this for three different dialysis durations and in two different dialyzer types. Just before the termination of the dialysis session, dialyzer clearance is assessed for different solutes from concentration measurements in blood samples as taken from the dialyzer inlet and outlet line.

The aim of this randomized cross-over study is to objectively quantify the impact of blocked fibers on the performance of different dialyzer membranes: ATA™ (asymmetric triacetate) membrane in the Solacea™ dialyzer, and polysulfone membrane in the FX800Cordiax dialyzer, and this with a decreased anticoagulation dose.

Read the detailed description

This single centre, randomized cross-over study includes ten consecutive stable chronic hemodialysis (HD) patients who experienced stable dialysis sessions during the last 4 weeks, and had no known coagulation disorder, active inflammation or malignancy. Double-needle vascular access is achieved through a native arterio-venous fistula or a well-functioning double lumen tunnelled central venous catheter. Patients are followed during 6 consecutive midweek dialysis sessions. At midweek, patients receive only 1/4th of their regular brand of Low-Molecular Weight Heparin anticoagulation at the beginning of the dialysis session. All test sessions are performed with blood flow at 300mL/min and dialysate flow at 500mL/min in post dilution hemodiafiltration (HDF) mode (substitution flow 75mL/min). Ultrafiltration rates are set according to the patient's interdialytic weight gain and clinical status.

Patients are randomized for hemodialyzer type and dialysis duration:

  1. ATA™ Solacea 19H - 60min dialysis
  2. ATA™ Solacea 19H - 120min dialysis
  3. ATA™ Solacea 19H - 240min dialysis
  4. polysulfone FX800Cordiax - 60min dialysis
  5. polysulfone FX800Cordiax - 120min dialysis
  6. polysulfone FX800Cordiax - 240min dialysis

Just before the termination of the 6 experimental midweek sessions, blood is sampled from the inlet and outlet blood lines. Blood samples are immediately centrifuged and serum vials are stored at -80°C until batch analysis. Post dialysis, dialyzers are rinsed and dried and scanned with micro computed tomography (CT) to count the number of open fibers.

Being tested
Dialyzer type, Dialysis duration
Keywords
Hemodialyzer, Fibre Clotting
Medical subject headings
Thrombosis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Dialyzer typeDevice

    Fiber blocking and dialyzer clearance is calculated in two different commercially available dialyzers

  • Dialysis durationOther

    Fiber blocking and dialyzer clearance is calculated for three different dialysis durations

Study groups in NCT04746391
Study groupRoleWhat they receive
Solacea_60minExperimental* blood sampling from dialyzer inlet and outlet line at 60min, just before dialysis termination * microCT scanning of rinsed and dried hemodialyzer, post dialysis in order to count open fibers
Receives: Device: Dialyzer type; Other: Dialysis duration
Solacea_120minExperimental* blood sampling from dialyzer inlet and outlet line at 120min, just before dialysis termination * microCT scanning of rinsed and dried hemodialyzer, post dialysis in order to count open fibers
Receives: Device: Dialyzer type; Other: Dialysis duration
Solacea_240minExperimental* blood sampling from dialyzer inlet and outlet line at 240min, just before dialysis termination * microCT scanning of rinsed and dried hemodialyzer, post dialysis in order to count open fibers
Receives: Device: Dialyzer type; Other: Dialysis duration
FX800_60minExperimental* blood sampling from dialyzer inlet and outlet line at 60min, just before dialysis termination * microCT scanning of rinsed and dried hemodialyzer, post dialysis in order to count open fibers
Receives: Device: Dialyzer type; Other: Dialysis duration
FX800_120minExperimental* blood sampling from dialyzer inlet and outlet line at 120min, just before dialysis termination * microCT scanning of rinsed and dried hemodialyzer, post dialysis in order to count open fibers
Receives: Device: Dialyzer type; Other: Dialysis duration
FX800_240minExperimental* blood sampling from dialyzer inlet and outlet line at 240min, just before dialysis termination * microCT scanning of rinsed and dried hemodialyzer, post dialysis in order to count open fibers
Receives: Device: Dialyzer type; Other: Dialysis duration

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Fibre blocking in hemodialyzers

    Fibre blocking as assessed post dialysis by a reference microCT scanning technique

    Measured: 6 weeks

  2. Hemodialyzer performance

    Dialyzer performance based on calculated clearances for different solutes

    Measured: 6 weeks

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted9 Feb 2021
  2. Study start19 May 2021
  3. Primary completion1 Jul 2021
  4. Study completion31 Jul 2021

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Crossover
Masking
None (open label)
Enrolment
10 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04746391
Sponsor's protocol ID
UGent_FiberClotting_2
Status last verified
Sep 2024
First submitted
29 Sep 2020
Last updated
19 Sep 2024
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Vanommeslaeghe F, Van Biesen W, Dierick M, Boone M, Dhondt A, Eloot S. Micro-computed tomography for the quantification of blocked fibers in hemodialyzers. Sci Rep. 2018 Feb 8;8(1):2677. doi: 10.1038/s41598-018-20898-w.

    PubMed 29422614

Questions about this trial

What is this clinical trial studying?

A study testing Dialyzer type and Dialysis duration in people with Hemodialysis and Coagulation, run by University Hospital, Ghent at 1 site in Belgium.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 3 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 19 Sep 2024. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Belgium. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Fibre blocking in hemodialyzers (time frame: 6 weeks). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04746391, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 19 Sep 2024.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in