To observe and evaluate the safety and efficacy of TaurusOne® transcatheter aortic valve system in patients with severe calcific aortic stenosis through a prospective, multicenter clinical trial using objective performance criteria. Read more about this study

Who is it for?
Ages 70 years and older
Conditions the study is for
Aortic Stenosis
What is being tested?
TaurusOne® transcatheter aortic valve replacement system
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
120 participants
Where
1 siteChina
Study dates
22 Sep 2017to 30 May 2024
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 70 years and older
  • All sexes
  • No healthy volunteers
  • Older adult

Who may be able to join

  • Patients who voluntarily participate and sign the informed consent and are able to comply with the entire trial process;
  • Age ≥ 70 years;
  • Patients with severe calcific aortic stenosis confirmed by echocardiography (Transaortic flow velocity ≥ 4.0 m/s, or aortic-valve gradient ≥ 40 mmHg (1 mmHg = 0.133 kPa), or aortic valve area < 0.8 cm2, or effective orifice area < 0.5 cm2/m2);
  • Patients who have symptoms obviously caused by aortic stenosis, NYHA Class II or worse;
  • Patients who are unsuitable for conventional surgery evaluated by the cardiac team (including at least two cardiovascular surgeons) [13] *;
  • Life expectancy after implantation of prosthetic valve is more than one year evaluated by the cardiac team (including at least two cardiac surgeons);
Show all 12Show fewer
  • Aortic annulus diameter ≥ 18 mm and ≤ 29 mm (measured by cardiac CT);
  • Ascending aorta diameter < 50 mm
  • : If the patient meets any of the following criteria judged by a multidisciplinary cardiac team composed of cardiologists and cardiovascular surgeons, radiologists, anesthesiologists, etc. (at least two cardiovascular surgeons), the patient will be identified as unsuitable for conventional surgery (at least STS ≥ 8 points):
  • Estimated risk of surgery-related death or disability > 50% within 1 year;
  • ≥3 major organ damage that could not be improved by surgery;
  • Obstacles related to surgical procedures judged as serious

Who cannot join

  • Patients with bacteremia or toxemia;
  • Previous endocarditis or active endocarditis;
  • Acute myocardial infarction (Q-wave MI, or non-Q-wave MI with elevated creatine kinase isoenzyme and troponin T) within 30 days;
  • Any intracardiac mass, left ventricular or atrial thrombus, vegetation on echocardiography;
  • Symptomatic atrial fibrillation that cannot be improved by drug therapy;
  • Familial hypertrophic cardiomyopathy;
Show all 29Show fewer
  • Mitral or tricuspid valve insufficiency (grade II regurgitation or higher);
  • Previous aortic valve graft (mechanical or bioprosthetic valve);
  • Known allergies to contrast agents, aspirin, heparin, ticlopidine drugs, nitinol shape memory alloy, or bovine products;
  • Known contraindications or allergies to anticoagulant regimens, or inability to use anticoagulants throughout the trial;
  • Other serious diseases that may reduce life expectancy to less than 12 months (such as clinically recurrent or metastatic cancer, congestive heart failure, etc.);
  • Current substance abuse problems (e.g., alcohol, cocaine, heroin, etc.);
  • Scheduled to undergo surgery that may result in protocol noncompliance or confounding in data interpretation.
  • Cerebrovascular accident (CVA) in the past 6 months;
  • Patients with common carotid artery or internal carotid artery or vertebral artery stenosis (>70%);
  • White blood cell count <3×109/L, platelet count <50×109/L;
  • Hemoglobin < 90 g/L;
  • Patients with severe coagulopathy;
  • Severe left ventricular dysfunction, left ventricular ejection fraction < 20%;
  • Abdominal or thoracic aortic aneurysm;
  • Hepatic encephalopathy or acute active hepatitis;
  • On dialysis or baseline creatinine level > 2.5 mg/dL (221 μ mol/L);
  • Bleeding tendency or history of coagulation disease or refusal of blood transfusion;
  • Patients with active peptic ulcer or active gastrointestinal (GI) bleeding;
  • Patients with neurological diseases that seriously affect mobility and activities of daily living;
  • Patients with mental illness or psychological disorders who are unable to communicate effectively;
  • Patients who need emergency surgery for any reason;
  • Patients who have participated in other drug or medical device clinical trials within 3 months prior to screening;
  • Other conditions that make the patient ineligible to participate in this clinical trial in judgement of investigators

Trial locations and contacts

1 site in 1 country.

China1 site
  • Peiga Medical Technology (Suzhou) Co., Ltd

    Suzhou, Jiangsu, 215025

Other trials in China

About this study

Official title: A Multicenter, Prospective, Single-Arm, Objective Performance Criteria Study to Evaluate the Safety and Efficacy of TaurusOne® Transcatheter Aortic Valve System in Patients With Severe Calcific Aortic Stenosis

To observe and evaluate the safety and efficacy of TaurusOne® transcatheter aortic valve system in patients with severe calcific aortic stenosis through a prospective, multicenter clinical trial using objective performance criteria.

Conditions
Aortic Stenosis
Being tested
TaurusOne® transcatheter aortic valve replacement system
Medical subject headings
Aortic Valve Stenosis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • TaurusOne® transcatheter aortic valve replacement systemDevice

    The TaurusOne® Transcatheter Aortic Valve System consists of an aortic valve, an associated delivery catheter and a loading system. The aortic valve consists of a self-expanding nitinol frame, a sealing skirt and valve leaflets, which are made of bovine pericardium. The delivery system is mainly composed of conical head, opacity ring, inner tube, top ring, middle tube, outer tube, booster rod, stress diffusion catheter, handle, etc. The outflow end of the aortic valve is provided with three fixing holes evenly distributed on the circumference on the top ring of the delivery catheter, so as to facilitate the installation, delivery and release of the aortic valve. Before the operation, the aortic valve needs to be installed into the sheath of the delivery catheter as required.

Study groups in NCT04815785
Study groupRoleWhat they receive
A single set of testExperimentalThe experimental apparatus consisted of artificial aortic valve, transporter and loading system
Receives: Device: TaurusOne® transcatheter aortic valve replacement system

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. All-cause mortality at 12 months

    All-cause mortality

    Measured: 12 months

Secondary outcomes (3)
  1. Device success rate (Immediate after procedure)

    • Successful delivery and release of vascular access and prosthetic aortic valve, and successful withdrawal of the delivery catheter
    • Accurate placement of prosthetic aortic valve at the anatomical site
    • Prosthetic aortic valve meets the desired requirements (mean valve gradient < 20 mm Hg or maximal flow velocity < 3 m/s; No severe prosthetic valve regurgitation or perivalvular leak)

    Measured: Immediate after procedure

  2. Procedure success rate

    A successful procedure is defined as successful implantation of the prosthetic aortic valve at the correct anatomical site 72 hours after the operation or before discharge without severe prosthetic valve regurgitation or perivalvular leak.

    Measured: 72 hours after procedure/prior to discharge

  3. Cardiac function improvement

    NYHA functional classification

    Measured: 30 days, 6 months, 12 months, 2 years, 3 years, 4 years and 5 years

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted25 Mar 2021
  2. Study start22 Sep 2017
  3. Primary completion11 May 2020
  4. Study completion30 May 2024 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
120 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04815785
Sponsor's protocol ID
CSP12000-2
Status last verified
Oct 2023
First submitted
6 Mar 2021
Last updated
24 Oct 2023
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No

Questions about this trial

What is this clinical trial studying?

A study testing TaurusOne® transcatheter aortic valve replacement system in people with Aortic Stenosis, run by Peijia Medical Technology (Suzhou) Co., Ltd. at 1 site in China.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 12 inclusion and 29 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 24 Oct 2023. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in China. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

All-cause mortality at 12 months (time frame: 12 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 24 Oct 2023.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in