Type 1 DiabetesNCT04949022
Glycemic Outcomes and Safety With Minimed 780G System in Children With Type 1 Diabetes Aged 2-6 Years
A study testing Medronic 780G insulin pump in people with Type 1 Diabetes, run by Helsinki University Central Hospital at 1 site in Finland.
Trial summary
The purpose of this study is to evaluate the effectiveness of advanced hybrid-closed loop system, Minimed 780G to glycemic control and safety in children aged 2-6 years with type 1 diabetes. Read more about this study
- Who is it for?
- Ages 2 to 6 years
- Conditions the study is for
- Type 1 Diabetes
- What is being tested?
- Medronic 780G insulin pump
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 38 participants
- Where
- 1 siteFinland
- Study dates
- 23 Aug 2021to 31 Dec 2023
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 2 to 6 years
- All sexes
- No healthy volunteers
- Child
Who may be able to join
- total insulin daily dose ≥ 8 units
- HbA1c < 10%
- capability to use pump and the CGM
- time from diabetes diagnosis more than 6 months
Who cannot join
- hemophilia or any other bleeding disorder, a condition, which in the opinion of the investigator would put the participant at risk during the trial
Trial locations and contacts
1 site in 1 country.
Finland1 site, 1 recruiting
- Recruiting
Helsinki University Hospital, New Children's Hospital and Jorvi Hospital
Helsinki
Anna-Kaisa Tuomaala, MD, PhD, +358505430180, anna-kaisa.tuomaala@hus.fi
Anna-Kaisa Tuomaala, MD, PhD
About this study
The purpose of this study is to evaluate the effectiveness of advanced hybrid-closed loop system, Minimed 780G to glycemic control and safety in children aged 2-6 years with type 1 diabetes.
Additionally, the study evaluates the perceived burden of the diabetes treatment to families during the advanced hybrid-closed loop system treatment (diabetes distress).
Read more
This is a prospective, non-randomized, single-arm study, where primary endpoint is the change in TIR after hybrid-closed loop system initiation. Secondary endpoints are safety (number of severe hypoglycaemias and diabetic ketoacidosis, DKA), HbA1c, time below range (TBR), mean sensor glucose (SG), standard deviation of SG, and coefficient of variation (CV).
The inclusion criteria are 1) TDD (total insulin daily dose) ≥ 8 units, 2) HbA1c < 10%, 3) capability to use pump and the CGM, and 4) time from diabetes diagnosis more than 6 months. The exclusion criteria are hemophilia or any other bleeding disorder, a condition, which in the opinion of the investigator would put the participant at risk during the trial.
Read the detailed description
BACKGROUND
The treatment of small children's type 1 diabetes (T1D) is challenging. There is often great day-to-day and within-day variability in glucose levels and HbA1c targets are hard to achieve. The results on hybrid closed loop systems (HCL) in children have been encouraging, suggesting that an algorithm, which automatically doses basal insulin based on sensor glucose (SG) levels, improves time in range (TIR) (3.9-10 mmol/l / 71-180 mg/dl) and reduces the time spent below range (TBR). Despite of these improvements, the target level of TIR (70%) has not been reached in these studies.
In pivotal studies, Minimed 780G advanced HCL system has helped children over 7 years old to reach higher TIR and improve mealtime glycaemia without increasing TBR, severe hypoglycaemias or ketoacidosis.
This study evaluates the effectiveness to glycemic control and safety of advanced hybrid-closed loop system, Minimed 780G, in children aged between 2.0-6.99 years, with type 1 diabetes.
The study protocol is explained to the participants (2.0-6.99 year-old children) orally. Informed consent from participants' caregivers and those participants who can write will be taken by investigators, clinicians or diabetes nurses. The investigator will explain the nature of the study to the subject, and answer all questions regarding this study. Prior to any study-related screening procedures being performed on the participant, the informed consent statement will be reviewed and signed and dated by participant's caregiver.
STUDY PROTOCOL
The study includes a two week run-in-phase in open loop Manual mode, which equals for standard sensor augmented pump (SAP) treatment (this feature is also in the same device), which is followed by a three month study phase with advanced hybrid closed loop Auto mode.
The participants will be given an advanced HCL pump (MiniMed 780G™ system with SmartGuard Medtronic, Northridge, CA). Minimed 780g™ is an insulin pump, which doses insulin automatically to patients subcutaneous tissue every 5 minutes based on SG values. The maximal dosing is based on participants TDD. The SmartGuard feature uses meal information, up to date SG reading, and SG target values to control basal insulin delivery. Additionally, it can automatically deliver a correction bolus to correct a high SG reading. The MiniMed 780G insulin pump requires a minimum of eight units and a maximum of 250 units per day to operate using the SmartGuard feature (Medtronic Minimed 780g™ system user guide).
This device has CE mark and is indicated to children aged over 7 years who require insulin over 8 units/day. In manufacturers safety studies, no adverse effects (diabetic ketoacidosis (DKA) or severe hypoglycaemias) has been reported in children over 7 years old who had TDD over 8 units/day (MDT personal communication).
The infusion set of insulin pump is changed every 2-3 days by patients' caregivers. The material connected to subcutaneous tissue is Teflon. The SG values are measured by continuous glucose monitor (CGM). The used CGM is Guardian3 sensor, which is integrated to Minimed 780g™ system. It measures the glucose level in the subcutaneous tissue. The CGM sensor connects to a transmitter that sends the glucose data to insulin pump. The sensor is worn for 7 days and then replaced with a new one by the participants' caregivers.
The traceability is achieved by each device's serial number (insulin pump, CGM transmitter). The glucose sensors, infusion sets, reservoirs and glucose sensors have lot numbers.
The families are trained to use the device by Medtronic's local representatives (technical issues), diabetes nurses, and clinicians (dosing and other medical issues). If the family has been on a sensor augmented pump (SAP) treatment previously, training includes one 3 hour session, a normal procedure in our clinic, at the outpatient clinic. If family has no previous experience on pump treatment or CGM, they will first try CGM out for 2 weeks and then 3-days visit on day hospital is arranged to first learn the basics on insulin pump treatment.
POWER ANALYSES
Based on previous studies, it was estimated that a significant difference in increased TIR between the advanced HCL treatment and the Manual mode would be 10% and the standard deviation is expected to be 13%. Taken these into account, the power of 90% to detect a difference between the modes with type 1 error rate of 0.05, 35 participants should complete the protocol. The dropout rate is estimated to be less than 3%, thus 38 HCL systems have been reserved for 38 participants.
ETHICAL ISSUES
This study is conducted in accordance with the ethical principles that have their origins in the Declaration of Helsinki. This study will be conducted in accordance with Good Clinical Practice (GCP), as defined by the International Conference on Harmonization (ICH) and in accordance with the ethical principles underlying European Union Directive 2001/20/EC and 2005/28/EC (or Regulation (EU) No 536/2014). The ethics committee of Helsinki University Hospital and The Finnish Medicines Agency has approved the study protocol.
- Conditions
- Type 1 Diabetes
- Being tested
- Medronic 780G insulin pump
- Keywords
- hybrid closed loop system
- Medical subject headings
- Diabetes Mellitus, Type 1
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Medronic 780G insulin pumpDevice
Commercial hybrid closed loop system Medronic 780G
| Study group | Role | What they receive |
|---|---|---|
| Hybrid closed loop system | Experimental | Initiation of 780G insulin pump. First two weeks run-in-phase in open loop Manual mode, followed by a12 month study phase with advanced hybrid closed loop Auto mode. Receives: Device: Medronic 780G insulin pump |
What is being measured
The primary outcome is the main question the study is designed to answer.
Time in range (glucose between 3.9-10 mmol/l) before and during hybrid close loop insulin pump treatment
Time in range (%) derived from continuous glucose monitoring
Measured: Up to 3 months
Time in range (glucose between 3.9-10 mmol/l) before and during hybrid close loop insulin pump treatment
Time in range (%) derived from continuous glucose monitoring
Measured: Up to 12 months
Secondary outcomes (8)
The number of severe hypoglycemia before and during hybrid close loop insulin pump treatment
Number of hypoglycemia (glucose <3.0 and altered mental status) derived from blood glucose monitoring
Measured: Up to 3 months
The number of severe hypoglycemia before and during hybrid close loop insulin pump treatment
Number of hypoglycemia (glucose <3.0 and altered mental status) derived from blood glucose monitoring
Measured: Up to 12 months
Number of diabetic ketoacidosis in participant before and during hybrid close loop insulin pump treatment
Number of diabetes ketoacidosis derived from patient information system
Measured: Up to 3 months
Number of diabetic ketoacidosis in participant before and during hybrid close loop insulin pump treatment
Number of diabetes ketoacidosis derived from patient information system
Measured: Up to 12 months
Diabetes distress before and during hybrid close loop insulin pump treatment
Parents diabetes distress measured with validated questionnaire: Problem Areas In Diabetes-Parent Revised (PAID-Pr) (scored 0-72)
Measured: Up to 3 months
Diabetes distress before and during hybrid close loop insulin pump treatment
Parents diabetes distress measured with validated questionnaire: Problem Areas In Diabetes-Parent Revised (PAID-Pr) (scored 0-72)
Measured: Up to 12 months
HbA1c before and during hybrid close loop insulin pump treatment
HbA1c (mmol/mol, %) measured from blood during treatment
Measured: Up to 3 months
HbA1c before and during hybrid close loop insulin pump treatment
HbA1c (mmol/mol, %) measured from blood during treatment
Measured: Up to 12 months
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted2 Jul 2021
- Study start23 Aug 2021
- Primary completion1 Oct 2022 (estimated)
- Study completion31 Dec 2023 (estimated)
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (6)Papers the sponsor has linked to this study.
- Other trials for Type 1 DiabetesStudies of the same condition, open and under way.
- More trials run by Helsinki University Central HospitalThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 38 participants (estimated)
Sponsor and investigators
- Lead sponsor
- Helsinki University Central Hospital
- Sponsor type
- University, hospital or other
- Collaborators
- Medtronic International Trading Sarl
- Responsible party
- Principal investigator, Tero Varimo, MD, PhD, Helsinki University Central Hospital
- Investigators
- Anna-Kaisa Tuomaala, MD, PhD, Principal investigator, Helsinki University Hospital, New Children's Hospital
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04949022
- Sponsor's protocol ID
- ERP-2020-12544
- Status last verified
- Jan 2022
- First submitted
- 17 Jun 2021
- Last updated
- 25 Jan 2022
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Yes: The data that support the findings of this study are available from the corresponding author upon reasonable request.
Publications
Miller KM, Foster NC, Beck RW, Bergenstal RM, DuBose SN, DiMeglio LA, Maahs DM, Tamborlane WV; T1D Exchange Clinic Network. Current state of type 1 diabetes treatment in the U.S.: updated data from the T1D Exchange clinic registry. Diabetes Care. 2015 Jun;38(6):971-8. doi: 10.2337/dc15-0078.
PubMed 25998289Breton MD, Kanapka LG, Beck RW, Ekhlaspour L, Forlenza GP, Cengiz E, Schoelwer M, Ruedy KJ, Jost E, Carria L, Emory E, Hsu LJ, Oliveri M, Kollman CC, Dokken BB, Weinzimer SA, DeBoer MD, Buckingham BA, Chernavvsky D, Wadwa RP; iDCL Trial Research Group. A Randomized Trial of Closed-Loop Control in Children with Type 1 Diabetes. N Engl J Med. 2020 Aug 27;383(9):836-845. doi: 10.1056/NEJMoa2004736.
PubMed 32846062Lind M, Pivodic A, Svensson AM, Olafsdottir AF, Wedel H, Ludvigsson J. HbA1c level as a risk factor for retinopathy and nephropathy in children and adults with type 1 diabetes: Swedish population based cohort study. BMJ. 2019 Aug 28;366:l4894. doi: 10.1136/bmj.l4894.
PubMed 31462492Hagger V, Hendrieckx C, Sturt J, Skinner TC, Speight J. Diabetes Distress Among Adolescents with Type 1 Diabetes: a Systematic Review. Curr Diab Rep. 2016 Jan;16(1):9. doi: 10.1007/s11892-015-0694-2.
PubMed 26748793Pulkkinen MA, Varimo TJ, Hakonen ET, Hero MT, Miettinen PJ, Tuomaala AK. During an 18-month course of automated insulin delivery treatment, children aged 2 to 6 years achieve and maintain a higher time in tight range. Diabetes Obes Metab. 2024 Jun;26(6):2431-2438. doi: 10.1111/dom.15562. Epub 2024 Mar 21.
PubMed 38514384Pulkkinen MA, Varimo TJ, Hakonen ET, Harsunen MH, Hyvonen ME, Janer JN, Kiiveri SM, Laakkonen HM, Laakso SM, Wehkalampi K, Hero MT, Miettinen PJ, Tuomaala AK. MiniMed 780G in 2- to 6-Year-Old Children: Safety and Clinical Outcomes After the First 12 Weeks. Diabetes Technol Ther. 2023 Feb;25(2):100-107. doi: 10.1089/dia.2022.0313. Epub 2022 Dec 30.
PubMed 36511831
Study at a glance
From the registry record, last updated by the sponsor on 25 Jan 2022. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Glycemic Outcomes and Safety With Minimed 780G System in Children With Type 1 Diabetes Aged 2-6 Years
- ClinicalTrials.gov ID
- NCT04949022
- Acronym / sponsor ID
- ERP-2020-12544
- Conditions
- Type 1 Diabetes
- Keywords
- hybrid closed loop system
- Study type
- Interventional
- Recruitment status
- Unknown status
- Enrolment
- 38 participants (estimated)
- Lead sponsor
- Helsinki University Central HospitalUniversity, hospital or other
- Collaborators
- Medtronic International Trading Sarl
- Study start
- 23 Aug 2021 (actual)
- Primary completion
- 1 Oct 2022 (estimated)
- Study completion
- 31 Dec 2023 (estimated)
- First posted
- 2 Jul 2021 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The purpose of this study is to evaluate the effectiveness of advanced hybrid-closed loop system, Minimed 780G to glycemic control and safety in children aged 2-6 years with type 1 diabetes.
Additionally, the study evaluates the perceived burden of the diabetes treatment to families during the advanced hybrid-closed loop system treatment (diabetes distress).
This is a prospective, non-randomized, single-arm study, where primary endpoint is the change in TIR after hybrid-closed loop system initiation. Secondary endpoints are safety (number of severe hypoglycaemias and diabetic ketoacidosis, DKA), HbA1c, time below range (TBR), mean sensor glucose (SG), standard deviation of SG, and coefficient of variation (CV).
The inclusion criteria are 1) TDD (total insulin daily dose) ≥ 8 units, 2) HbA1c < 10%, 3) capability to use pump and the CGM, and 4) time from diabetes diagnosis more than 6 months. The exclusion criteria are hemophilia or any other bleeding disorder, a condition, which in the opinion of the investigator would put the participant at risk during the trial.
Detailed description
BACKGROUND
The treatment of small children's type 1 diabetes (T1D) is challenging. There is often great day-to-day and within-day variability in glucose levels and HbA1c targets are hard to achieve. The results on hybrid closed loop systems (HCL) in children have been encouraging, suggesting that an algorithm, which automatically doses basal insulin based on sensor glucose (SG) levels, improves time in range (TIR) (3.9-10 mmol/l / 71-180 mg/dl) and reduces the time spent below range (TBR). Despite of these improvements, the target level of TIR (70%) has not been reached in these studies.
In pivotal studies, Minimed 780G advanced HCL system has helped children over 7 years old to reach higher TIR and improve mealtime glycaemia without increasing TBR, severe hypoglycaemias or ketoacidosis.
This study evaluates the effectiveness to glycemic control and safety of advanced hybrid-closed loop system, Minimed 780G, in children aged between 2.0-6.99 years, with type 1 diabetes.
The study protocol is explained to the participants (2.0-6.99 year-old children) orally. Informed consent from participants' caregivers and those participants who can write will be taken by investigators, clinicians or diabetes nurses. The investigator will explain the nature of the study to the subject, and answer all questions regarding this study. Prior to any study-related screening procedures being performed on the participant, the informed consent statement will be reviewed and signed and dated by participant's caregiver.
STUDY PROTOCOL
The study includes a two week run-in-phase in open loop Manual mode, which equals for standard sensor augmented pump (SAP) treatment (this feature is also in the same device), which is followed by a three month study phase with advanced hybrid closed loop Auto mode.
The participants will be given an advanced HCL pump (MiniMed 780G™ system with SmartGuard Medtronic, Northridge, CA). Minimed 780g™ is an insulin pump, which doses insulin automatically to patients subcutaneous tissue every 5 minutes based on SG values. The maximal dosing is based on participants TDD. The SmartGuard feature uses meal information, up to date SG reading, and SG target values to control basal insulin delivery. Additionally, it can automatically deliver a correction bolus to correct a high SG reading. The MiniMed 780G insulin pump requires a minimum of eight units and a maximum of 250 units per day to operate using the SmartGuard feature (Medtronic Minimed 780g™ system user guide).
This device has CE mark and is indicated to children aged over 7 years who require insulin over 8 units/day. In manufacturers safety studies, no adverse effects (diabetic ketoacidosis (DKA) or severe hypoglycaemias) has been reported in children over 7 years old who had TDD over 8 units/day (MDT personal communication).
The infusion set of insulin pump is changed every 2-3 days by patients' caregivers. The material connected to subcutaneous tissue is Teflon. The SG values are measured by continuous glucose monitor (CGM). The used CGM is Guardian3 sensor, which is integrated to Minimed 780g™ system. It measures the glucose level in the subcutaneous tissue. The CGM sensor connects to a transmitter that sends the glucose data to insulin pump. The sensor is worn for 7 days and then replaced with a new one by the participants' caregivers.
The traceability is achieved by each device's serial number (insulin pump, CGM transmitter). The glucose sensors, infusion sets, reservoirs and glucose sensors have lot numbers.
The families are trained to use the device by Medtronic's local representatives (technical issues), diabetes nurses, and clinicians (dosing and other medical issues). If the family has been on a sensor augmented pump (SAP) treatment previously, training includes one 3 hour session, a normal procedure in our clinic, at the outpatient clinic. If family has no previous experience on pump treatment or CGM, they will first try CGM out for 2 weeks and then 3-days visit on day hospital is arranged to first learn the basics on insulin pump treatment.
POWER ANALYSES
Based on previous studies, it was estimated that a significant difference in increased TIR between the advanced HCL treatment and the Manual mode would be 10% and the standard deviation is expected to be 13%. Taken these into account, the power of 90% to detect a difference between the modes with type 1 error rate of 0.05, 35 participants should complete the protocol. The dropout rate is estimated to be less than 3%, thus 38 HCL systems have been reserved for 38 participants.
ETHICAL ISSUES
This study is conducted in accordance with the ethical principles that have their origins in the Declaration of Helsinki. This study will be conducted in accordance with Good Clinical Practice (GCP), as defined by the International Conference on Harmonization (ICH) and in accordance with the ethical principles underlying European Union Directive 2001/20/EC and 2005/28/EC (or Regulation (EU) No 536/2014). The ethics committee of Helsinki University Hospital and The Finnish Medicines Agency has approved the study protocol.
Study design
- Primary purpose
- Treatment
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Hybrid closed loop system | Experimental | Device: Medronic 780G insulin pumpInitiation of 780G insulin pump. First two weeks run-in-phase in open loop Manual mode, followed by a12 month study phase with advanced hybrid closed loop Auto mode. |
Who may qualify
- Ages
- 2 to 6 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Child
Key inclusion criteria (4 listed)
- total insulin daily dose ≥ 8 units
- HbA1c < 10%
- capability to use pump and the CGM
- time from diabetes diagnosis more than 6 months
Key exclusion criteria (1 listed)
- hemophilia or any other bleeding disorder, a condition, which in the opinion of the investigator would put the participant at risk during the trial
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Medronic 780G insulin pumpCommercial hybrid closed loop system Medronic 780G | Device | Hybrid closed loop system |
Primary outcome
Time in range (glucose between 3.9-10 mmol/l) before and during hybrid close loop insulin pump treatment
Time frame: Up to 3 months
Time in range (%) derived from continuous glucose monitoring
Time in range (glucose between 3.9-10 mmol/l) before and during hybrid close loop insulin pump treatment
Time frame: Up to 12 months
Time in range (%) derived from continuous glucose monitoring
8 secondary outcomes
The number of severe hypoglycemia before and during hybrid close loop insulin pump treatment
Time frame: Up to 3 months
The number of severe hypoglycemia before and during hybrid close loop insulin pump treatment
Time frame: Up to 12 months
Number of diabetic ketoacidosis in participant before and during hybrid close loop insulin pump treatment
Time frame: Up to 3 months
Number of diabetic ketoacidosis in participant before and during hybrid close loop insulin pump treatment
Time frame: Up to 12 months
Diabetes distress before and during hybrid close loop insulin pump treatment
Time frame: Up to 3 months
Diabetes distress before and during hybrid close loop insulin pump treatment
Time frame: Up to 12 months
HbA1c before and during hybrid close loop insulin pump treatment
Time frame: Up to 3 months
HbA1c before and during hybrid close loop insulin pump treatment
Time frame: Up to 12 months
Results and safety
Results are not available in the source record.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 25 Jan 2022.
- Background: PubMed 25998289Miller KM, Foster NC, Beck RW, Bergenstal RM, DuBose SN, DiMeglio LA, Maahs DM, Tamborlane WV; T1D Exchange Clinic Network. Current state of type 1 diabetes treatment in the U.S.: updated data from the T1D Exchange clinic registry. Diabetes Care. 2015 Jun;38(6):971-8. doi: 10.2337/dc15-0078.
- Background: PubMed 32846062Breton MD, Kanapka LG, Beck RW, Ekhlaspour L, Forlenza GP, Cengiz E, Schoelwer M, Ruedy KJ, Jost E, Carria L, Emory E, Hsu LJ, Oliveri M, Kollman CC, Dokken BB, Weinzimer SA, DeBoer MD, Buckingham BA, Chernavvsky D, Wadwa RP; iDCL Trial Research Group. A Randomized Trial of Closed-Loop Control in Children with Type 1 Diabetes. N Engl J Med. 2020 Aug 27;383(9):836-845. doi: 10.1056/NEJMoa2004736.
- Background: PubMed 31462492Lind M, Pivodic A, Svensson AM, Olafsdottir AF, Wedel H, Ludvigsson J. HbA1c level as a risk factor for retinopathy and nephropathy in children and adults with type 1 diabetes: Swedish population based cohort study. BMJ. 2019 Aug 28;366:l4894. doi: 10.1136/bmj.l4894.
- Background: PubMed 26748793Hagger V, Hendrieckx C, Sturt J, Skinner TC, Speight J. Diabetes Distress Among Adolescents with Type 1 Diabetes: a Systematic Review. Curr Diab Rep. 2016 Jan;16(1):9. doi: 10.1007/s11892-015-0694-2.
- Derived from this study: PubMed 38514384Pulkkinen MA, Varimo TJ, Hakonen ET, Hero MT, Miettinen PJ, Tuomaala AK. During an 18-month course of automated insulin delivery treatment, children aged 2 to 6 years achieve and maintain a higher time in tight range. Diabetes Obes Metab. 2024 Jun;26(6):2431-2438. doi: 10.1111/dom.15562. Epub 2024 Mar 21.
- Derived from this study: PubMed 36511831Pulkkinen MA, Varimo TJ, Hakonen ET, Harsunen MH, Hyvonen ME, Janer JN, Kiiveri SM, Laakkonen HM, Laakso SM, Wehkalampi K, Hero MT, Miettinen PJ, Tuomaala AK. MiniMed 780G in 2- to 6-Year-Old Children: Safety and Clinical Outcomes After the First 12 Weeks. Diabetes Technol Ther. 2023 Feb;25(2):100-107. doi: 10.1089/dia.2022.0313. Epub 2022 Dec 30.
- Individual participant dataSharing planned: Yes. The data that support the findings of this study are available from the corresponding author upon reasonable request.
Related trials for Type 1 Diabetes
Not yet recruitingPhase 3
A Study to Evaluate the Effectiveness and Safety of the Drug AZD6234 for Managing Weight in Adults Who Are Obese or Overweight. These Participants May or May Not Also Have Type 2 Diabetes
Obesity, Overweight
RecruitingPhase 1
Pharmacokinetics, Safety, and Immunogenicity Comparison of Bmab1700 and Opdivo® as Adjuvant Monotherapy in Participants With Melanoma
Melanoma
Active, not recruitingPhase 2
A Study of Botensilimab and Balstilimab for the Treatment of Colorectal Cancer
Metastatic Colorectal Cancer
Not yet recruiting
Inter-Arm Differences in Continuous Glucose Monitor Readings in Adults With Diabetes
Continuous Glucose Monitoring, Type 1 Diabetes
RecruitingObservational study
Estimated Risk of Preeclampsia in the First Trimester and Its Association With Subclinical Atherosclerosis and Cardiovascular Risk in Women With Type 1 Diabetes
Type 1 Diabetes, Preeclampsia
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Anna-Kaisa Tuomaala, MD, PhD principal investigator
Helsinki University Hospital, New Children's Hospital
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Medronic 780G insulin pump in people with Type 1 Diabetes, run by Helsinki University Central Hospital at 1 site in Finland.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 4 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: status not confirmed, as of the sponsor's last update on 25 Jan 2022. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Finland. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
Results are not available in the source record.
How can a doctor refer a patient or contact the research team?
Contact Anna-Kaisa Tuomaala, MD, PhD (+358505430180, anna-kaisa.tuomaala@hus.fi), or a site near the patient. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Time in range (glucose between 3.9-10 mmol/l) before and during hybrid close loop insulin pump treatment (time frame: Up to 3 months). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT04949022, which also lists 6 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 25 Jan 2022.