Glycemic Outcomes and Safety With Minimed 780G System in Children With Type 1 Diabetes Aged 2-6 Years

A study testing Medronic 780G insulin pump in people with Type 1 Diabetes, run by Helsinki University Central Hospital at 1 site in Finland.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

The purpose of this study is to evaluate the effectiveness of advanced hybrid-closed loop system, Minimed 780G to glycemic control and safety in children aged 2-6 years with type 1 diabetes. Read more about this study

Who is it for?
Ages 2 to 6 years
Conditions the study is for
Type 1 Diabetes
What is being tested?
Medronic 780G insulin pump
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
38 participants
Where
1 siteFinland
Study dates
23 Aug 2021to 31 Dec 2023
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 2 to 6 years
  • All sexes
  • No healthy volunteers
  • Child

Who may be able to join

  • total insulin daily dose ≥ 8 units
  • HbA1c < 10%
  • capability to use pump and the CGM
  • time from diabetes diagnosis more than 6 months

Who cannot join

  • hemophilia or any other bleeding disorder, a condition, which in the opinion of the investigator would put the participant at risk during the trial

Trial locations and contacts

1 site in 1 country.

Anna-Kaisa Tuomaala, MD, PhD contact

+358505430180

anna-kaisa.tuomaala@hus.fi

Tero Varimo, MD, PhD contact

+358504279569

tero.varimo@hus.fi

Finland1 site, 1 recruiting
  • Helsinki University Hospital, New Children's Hospital and Jorvi Hospital

    Helsinki

    Anna-Kaisa Tuomaala, MD, PhD, +358505430180, anna-kaisa.tuomaala@hus.fi

    Anna-Kaisa Tuomaala, MD, PhD

    Recruiting

Other trials in Finland

About this study

The purpose of this study is to evaluate the effectiveness of advanced hybrid-closed loop system, Minimed 780G to glycemic control and safety in children aged 2-6 years with type 1 diabetes.

Additionally, the study evaluates the perceived burden of the diabetes treatment to families during the advanced hybrid-closed loop system treatment (diabetes distress).

Read more

This is a prospective, non-randomized, single-arm study, where primary endpoint is the change in TIR after hybrid-closed loop system initiation. Secondary endpoints are safety (number of severe hypoglycaemias and diabetic ketoacidosis, DKA), HbA1c, time below range (TBR), mean sensor glucose (SG), standard deviation of SG, and coefficient of variation (CV).

The inclusion criteria are 1) TDD (total insulin daily dose) ≥ 8 units, 2) HbA1c < 10%, 3) capability to use pump and the CGM, and 4) time from diabetes diagnosis more than 6 months. The exclusion criteria are hemophilia or any other bleeding disorder, a condition, which in the opinion of the investigator would put the participant at risk during the trial.

Read the detailed description

BACKGROUND

The treatment of small children's type 1 diabetes (T1D) is challenging. There is often great day-to-day and within-day variability in glucose levels and HbA1c targets are hard to achieve. The results on hybrid closed loop systems (HCL) in children have been encouraging, suggesting that an algorithm, which automatically doses basal insulin based on sensor glucose (SG) levels, improves time in range (TIR) (3.9-10 mmol/l / 71-180 mg/dl) and reduces the time spent below range (TBR). Despite of these improvements, the target level of TIR (70%) has not been reached in these studies.

In pivotal studies, Minimed 780G advanced HCL system has helped children over 7 years old to reach higher TIR and improve mealtime glycaemia without increasing TBR, severe hypoglycaemias or ketoacidosis.

This study evaluates the effectiveness to glycemic control and safety of advanced hybrid-closed loop system, Minimed 780G, in children aged between 2.0-6.99 years, with type 1 diabetes.

The study protocol is explained to the participants (2.0-6.99 year-old children) orally. Informed consent from participants' caregivers and those participants who can write will be taken by investigators, clinicians or diabetes nurses. The investigator will explain the nature of the study to the subject, and answer all questions regarding this study. Prior to any study-related screening procedures being performed on the participant, the informed consent statement will be reviewed and signed and dated by participant's caregiver.

STUDY PROTOCOL

The study includes a two week run-in-phase in open loop Manual mode, which equals for standard sensor augmented pump (SAP) treatment (this feature is also in the same device), which is followed by a three month study phase with advanced hybrid closed loop Auto mode.

The participants will be given an advanced HCL pump (MiniMed 780G™ system with SmartGuard Medtronic, Northridge, CA). Minimed 780g™ is an insulin pump, which doses insulin automatically to patients subcutaneous tissue every 5 minutes based on SG values. The maximal dosing is based on participants TDD. The SmartGuard feature uses meal information, up to date SG reading, and SG target values to control basal insulin delivery. Additionally, it can automatically deliver a correction bolus to correct a high SG reading. The MiniMed 780G insulin pump requires a minimum of eight units and a maximum of 250 units per day to operate using the SmartGuard feature (Medtronic Minimed 780g™ system user guide).

This device has CE mark and is indicated to children aged over 7 years who require insulin over 8 units/day. In manufacturers safety studies, no adverse effects (diabetic ketoacidosis (DKA) or severe hypoglycaemias) has been reported in children over 7 years old who had TDD over 8 units/day (MDT personal communication).

The infusion set of insulin pump is changed every 2-3 days by patients' caregivers. The material connected to subcutaneous tissue is Teflon. The SG values are measured by continuous glucose monitor (CGM). The used CGM is Guardian3 sensor, which is integrated to Minimed 780g™ system. It measures the glucose level in the subcutaneous tissue. The CGM sensor connects to a transmitter that sends the glucose data to insulin pump. The sensor is worn for 7 days and then replaced with a new one by the participants' caregivers.

The traceability is achieved by each device's serial number (insulin pump, CGM transmitter). The glucose sensors, infusion sets, reservoirs and glucose sensors have lot numbers.

The families are trained to use the device by Medtronic's local representatives (technical issues), diabetes nurses, and clinicians (dosing and other medical issues). If the family has been on a sensor augmented pump (SAP) treatment previously, training includes one 3 hour session, a normal procedure in our clinic, at the outpatient clinic. If family has no previous experience on pump treatment or CGM, they will first try CGM out for 2 weeks and then 3-days visit on day hospital is arranged to first learn the basics on insulin pump treatment.

POWER ANALYSES

Based on previous studies, it was estimated that a significant difference in increased TIR between the advanced HCL treatment and the Manual mode would be 10% and the standard deviation is expected to be 13%. Taken these into account, the power of 90% to detect a difference between the modes with type 1 error rate of 0.05, 35 participants should complete the protocol. The dropout rate is estimated to be less than 3%, thus 38 HCL systems have been reserved for 38 participants.

ETHICAL ISSUES

This study is conducted in accordance with the ethical principles that have their origins in the Declaration of Helsinki. This study will be conducted in accordance with Good Clinical Practice (GCP), as defined by the International Conference on Harmonization (ICH) and in accordance with the ethical principles underlying European Union Directive 2001/20/EC and 2005/28/EC (or Regulation (EU) No 536/2014). The ethics committee of Helsinki University Hospital and The Finnish Medicines Agency has approved the study protocol.

Conditions
Type 1 Diabetes
Being tested
Medronic 780G insulin pump
Keywords
hybrid closed loop system
Medical subject headings
Diabetes Mellitus, Type 1

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Medronic 780G insulin pumpDevice

    Commercial hybrid closed loop system Medronic 780G

Study groups in NCT04949022
Study groupRoleWhat they receive
Hybrid closed loop systemExperimentalInitiation of 780G insulin pump. First two weeks run-in-phase in open loop Manual mode, followed by a12 month study phase with advanced hybrid closed loop Auto mode.
Receives: Device: Medronic 780G insulin pump

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Time in range (glucose between 3.9-10 mmol/l) before and during hybrid close loop insulin pump treatment

    Time in range (%) derived from continuous glucose monitoring

    Measured: Up to 3 months

  2. Time in range (glucose between 3.9-10 mmol/l) before and during hybrid close loop insulin pump treatment

    Time in range (%) derived from continuous glucose monitoring

    Measured: Up to 12 months

Secondary outcomes (8)
  1. The number of severe hypoglycemia before and during hybrid close loop insulin pump treatment

    Number of hypoglycemia (glucose <3.0 and altered mental status) derived from blood glucose monitoring

    Measured: Up to 3 months

  2. The number of severe hypoglycemia before and during hybrid close loop insulin pump treatment

    Number of hypoglycemia (glucose <3.0 and altered mental status) derived from blood glucose monitoring

    Measured: Up to 12 months

  3. Number of diabetic ketoacidosis in participant before and during hybrid close loop insulin pump treatment

    Number of diabetes ketoacidosis derived from patient information system

    Measured: Up to 3 months

  4. Number of diabetic ketoacidosis in participant before and during hybrid close loop insulin pump treatment

    Number of diabetes ketoacidosis derived from patient information system

    Measured: Up to 12 months

  5. Diabetes distress before and during hybrid close loop insulin pump treatment

    Parents diabetes distress measured with validated questionnaire: Problem Areas In Diabetes-Parent Revised (PAID-Pr) (scored 0-72)

    Measured: Up to 3 months

  6. Diabetes distress before and during hybrid close loop insulin pump treatment

    Parents diabetes distress measured with validated questionnaire: Problem Areas In Diabetes-Parent Revised (PAID-Pr) (scored 0-72)

    Measured: Up to 12 months

  7. HbA1c before and during hybrid close loop insulin pump treatment

    HbA1c (mmol/mol, %) measured from blood during treatment

    Measured: Up to 3 months

  8. HbA1c before and during hybrid close loop insulin pump treatment

    HbA1c (mmol/mol, %) measured from blood during treatment

    Measured: Up to 12 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted2 Jul 2021
  2. Study start23 Aug 2021
  3. Primary completion1 Oct 2022 (estimated)
  4. Study completion31 Dec 2023 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
38 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT04949022
Sponsor's protocol ID
ERP-2020-12544
Status last verified
Jan 2022
First submitted
17 Jun 2021
Last updated
25 Jan 2022
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Yes: The data that support the findings of this study are available from the corresponding author upon reasonable request.

Publications

  • Miller KM, Foster NC, Beck RW, Bergenstal RM, DuBose SN, DiMeglio LA, Maahs DM, Tamborlane WV; T1D Exchange Clinic Network. Current state of type 1 diabetes treatment in the U.S.: updated data from the T1D Exchange clinic registry. Diabetes Care. 2015 Jun;38(6):971-8. doi: 10.2337/dc15-0078.

    PubMed 25998289
  • Breton MD, Kanapka LG, Beck RW, Ekhlaspour L, Forlenza GP, Cengiz E, Schoelwer M, Ruedy KJ, Jost E, Carria L, Emory E, Hsu LJ, Oliveri M, Kollman CC, Dokken BB, Weinzimer SA, DeBoer MD, Buckingham BA, Chernavvsky D, Wadwa RP; iDCL Trial Research Group. A Randomized Trial of Closed-Loop Control in Children with Type 1 Diabetes. N Engl J Med. 2020 Aug 27;383(9):836-845. doi: 10.1056/NEJMoa2004736.

    PubMed 32846062
  • Lind M, Pivodic A, Svensson AM, Olafsdottir AF, Wedel H, Ludvigsson J. HbA1c level as a risk factor for retinopathy and nephropathy in children and adults with type 1 diabetes: Swedish population based cohort study. BMJ. 2019 Aug 28;366:l4894. doi: 10.1136/bmj.l4894.

    PubMed 31462492
  • Hagger V, Hendrieckx C, Sturt J, Skinner TC, Speight J. Diabetes Distress Among Adolescents with Type 1 Diabetes: a Systematic Review. Curr Diab Rep. 2016 Jan;16(1):9. doi: 10.1007/s11892-015-0694-2.

    PubMed 26748793
  • Pulkkinen MA, Varimo TJ, Hakonen ET, Hero MT, Miettinen PJ, Tuomaala AK. During an 18-month course of automated insulin delivery treatment, children aged 2 to 6 years achieve and maintain a higher time in tight range. Diabetes Obes Metab. 2024 Jun;26(6):2431-2438. doi: 10.1111/dom.15562. Epub 2024 Mar 21.

    PubMed 38514384
  • Pulkkinen MA, Varimo TJ, Hakonen ET, Harsunen MH, Hyvonen ME, Janer JN, Kiiveri SM, Laakkonen HM, Laakso SM, Wehkalampi K, Hero MT, Miettinen PJ, Tuomaala AK. MiniMed 780G in 2- to 6-Year-Old Children: Safety and Clinical Outcomes After the First 12 Weeks. Diabetes Technol Ther. 2023 Feb;25(2):100-107. doi: 10.1089/dia.2022.0313. Epub 2022 Dec 30.

    PubMed 36511831

Questions about this trial

What is this clinical trial studying?

A study testing Medronic 780G insulin pump in people with Type 1 Diabetes, run by Helsinki University Central Hospital at 1 site in Finland.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 25 Jan 2022. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Finland. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Anna-Kaisa Tuomaala, MD, PhD (+358505430180, anna-kaisa.tuomaala@hus.fi), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Time in range (glucose between 3.9-10 mmol/l) before and during hybrid close loop insulin pump treatment (time frame: Up to 3 months). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT04949022, which also lists 6 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 25 Jan 2022.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in