High Flow Nasal CannulaHILOOPNCT04965844
Closed-loop Oxygen Control for High Flow Nasal Therapy
A study testing Oxygen close-loop in people with High Flow Nasal Cannula and Oxygen Therapy, run by Hospital Universitari Vall d'Hebron Research Institute at 1 site in Spain.
Trial summary
In patients with acute hypoxemic respiratory failure (AHRF), High Flow Nasal Therapy (HFNT) improves oxygenation, tolerance, and decrease work of breathing as compared to standard oxygen therapy by facemask. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- High Flow Nasal Cannula, Oxygen Therapy, Hypoxemia
- What is being tested?
- Oxygen close-loop
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 53 participants
- Where
- 1 siteSpain
- Study dates
- 27 Apr 2021to 10 Aug 2021
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Adult (>17yo) patients admitted to the ICU treated with HFNT for at least 8h
- Requiring FiO2 ≥ 30% to keep SpO2 in the target ranges defined by the clinician
- Written informed consent signed and dated by the patient or one relative in case that the patient is unable to consent, after full explanation of the study by the investigator and prior to study participation.
Who cannot join
- Patient with indication for immediate continuous positive airway pressure (CPAP), noninvasive ventilation (NIV), or invasive mechanical ventilation
- Hemodynamic instability defined as a need of continuous infusion of epinephrine or norepinephrine > 1 mg/h
- Low quality on the SpO2 measurement using finger and ear sensor (quality index below 60% on the Massimo SpO2 sensor, which is displayed by a red or orange colour bar)
- Severe acidosis (pH ≤ 7.30)
- Pregnant woman
- Patients deemed at high risk for need of mechanical ventilation within the next 8 hours
Show all 13Show fewer
- Chronic or acute dyshemoglobinemia: methemoglobin, carbon monoxide (CO) poisoning, sickle cell disease
- Tracheotomised patient
- Formalized ethical decision to withhold or withdraw life support
- Patient under guardianship
- Patient deprived of liberties
- Patient included in another interventional research study under consent
- Patient already enrolled in the present study in a previous episode of acute respiratory failure
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Safety and Efficacy of a Closed-loop Oxygen Control for High Flow Nasal Therapy in ICU Patients: a Randomized Cross-over Study (The HILOOP Study)
In patients with acute hypoxemic respiratory failure (AHRF), High Flow Nasal Therapy (HFNT) improves oxygenation, tolerance, and decrease work of breathing as compared to standard oxygen therapy by facemask. Current guidelines recommend adjusting oxygen flow rates to keep the oxygen saturation measured by pulse oximetry (SpO2) in the target range and avoid hypoxemia and hyperoxemia. The hypothesis of the study is that closed loop oxygen control increases the time spent within clinically targeted SpO2 ranges and decreases the time spent outside clinical target SpO2 ranges as compared to manual oxygen control in ICU patients treated with HFNT.
- Conditions
- High Flow Nasal Cannula, Oxygen Therapy, Hypoxemia, Hyperoxemia, Acute Respiratory Failure, Respiratory Insufficiency
- Being tested
- Oxygen close-loop, No intervention
- Keywords
- High flow nasal cannula, Nasal high flow, Oxygen close-loop, Hypoxemia, Hyperoxemia
- Medical subject headings
- Hypoxia, Respiratory Insufficiency
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Oxygen close-loopDevice
The Automatic FiO2 option provides automated adjustment of the ventilator Oxygen setting to maintain the patient's SpO2 in a defined target range. When using the software option, the user defines the SpO2 target range, as well as the SpO2 emergency limits, and the device adjusts the Oxygen setting to keep the patient's SpO2 in the target range.
No interventionDevice
Manual FiO2 adjustment according to SpO2 values
| Study group | Role | What they receive |
|---|---|---|
| Oxygen close-loop | Experimental | Four hours period where the fraction of inspired oxygen delivered will be automatically titrated based on SpO2 values. Receives: Device: Oxygen close-loop |
| Manual FiO2 adjustment | Active comparator | Four hours period where the fraction of inspired oxygen delivered will be manually adjusted by the healthcare personnel based on SpO2 values. Receives: Device: No intervention |
What is being measured
The primary outcome is the main question the study is designed to answer.
Percentage of time spent in optimal SpO2 range
The optimal SpO2 range will be defined according to the SpO2 targets determined by the clinician.
Measured: 4 hours
Secondary outcomes (12)
Percentage of time spent in sub-optimal SpO2 range
SpO2 values outside the optimal range but still within an acceptable limit (2-3 percent above and below the optimal range)
Measured: 4 hours
Percentage of time spent out of range
Above or below the suboptimal limits specified at the begginning of the study
Measured: 4 hours
Percentage of time with SpO2 signal available
Time with SpO2 signal available
Measured: 4 hours
Mean SpO2/FiO2
Mean oxygenation value
Measured: 4 hours
ROX index
Is a predictor of HFNT success/failure defined as (SpO2/FiO2)/respiratory rate
Measured: 4 hours
Percentage of time with SpO2 below 88 and 85 percent
Duration of time with SpO2 <85 percent and <88 percent, respectively
Measured: 4 hours
Number of events with SpO2 below 88 and 85 percent
Frequency of SpO2 decreases <85 percent and <88 percent, respectively
Measured: 4 hours
Mean FiO2
Mean fraction of inspired oxygen
Measured: 4 hours
Percentage of time with FiO2 below 40 percent and above 60%
Percentage of time that FiO2 is <40 percent and >60 percent, respectively
Measured: 4 hours
Number of manual adjustments
Frequency of manual adjustments of FiO2
Measured: 4 hours
Number of alarms
Frequency of alarms
Measured: 4 hours
Patient comfort
Comfort score by visual analogic scale (from 0 to 10)
Measured: 4 hours
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted16 Jul 2021
- Study start27 Apr 2021
- Primary completion10 Aug 2021
- Study completion10 Aug 2021
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (4)Papers the sponsor has linked to this study.
- Other trials for High Flow Nasal CannulaStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- Single blind
- Who is masked
- Participant
- Enrolment
- 53 participants (actual)
Sponsor and investigators
- Lead sponsor
- Hospital Universitari Vall d'Hebron Research Institute
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT04965844
- Sponsor's protocol ID
- PR(AG)539/2020
- Acronym
- HILOOP
- Status last verified
- Oct 2021
- First submitted
- 4 May 2021
- Last updated
- 9 Dec 2021
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
L'Her E, Dias P, Gouillou M, Riou A, Souquiere L, Paleiron N, Archambault P, Bouchard PA, Lellouche F. Automatic versus manual oxygen administration in the emergency department. Eur Respir J. 2017 Jul 20;50(1):1602552. doi: 10.1183/13993003.02552-2016. Print 2017 Jul.
PubMed 28729473Helmerhorst HJ, Roos-Blom MJ, van Westerloo DJ, de Jonge E. Association Between Arterial Hyperoxia and Outcome in Subsets of Critical Illness: A Systematic Review, Meta-Analysis, and Meta-Regression of Cohort Studies. Crit Care Med. 2015 Jul;43(7):1508-19. doi: 10.1097/CCM.0000000000000998.
PubMed 25855899Arnal JM, Garnero A, Novotni D, Corno G, Donati SY, Demory D, Quintana G, Ducros L, Laubscher T, Durand-Gasselin J. Closed loop ventilation mode in Intensive Care Unit: a randomized controlled clinical trial comparing the numbers of manual ventilator setting changes. Minerva Anestesiol. 2018 Jan;84(1):58-67. doi: 10.23736/S0375-9393.17.11963-2. Epub 2017 Jul 5.
PubMed 28679200Roca O, Caritg O, Santafe M, Ramos FJ, Pacheco A, Garcia-de-Acilu M, Ferrer R, Schultz MJ, Ricard JD. Closed-loop oxygen control improves oxygen therapy in acute hypoxemic respiratory failure patients under high flow nasal oxygen: a randomized cross-over study (the HILOOP study). Crit Care. 2022 Apr 14;26(1):108. doi: 10.1186/s13054-022-03970-w.
PubMed 35422002
Study at a glance
From the registry record, last updated by the sponsor on 9 Dec 2021. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Safety and Efficacy of a Closed-loop Oxygen Control for High Flow Nasal Therapy in ICU Patients: a Randomized Cross-over Study (The HILOOP Study)
- ClinicalTrials.gov ID
- NCT04965844
- Acronym / sponsor ID
- HILOOP / PR(AG)539/2020
- Conditions
- High Flow Nasal Cannula, Oxygen Therapy, Hypoxemia, Hyperoxemia, Acute Respiratory Failure, Respiratory Insufficiency
- Keywords
- High flow nasal cannula, Nasal high flow, Oxygen close-loop, Hypoxemia, Hyperoxemia
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 53 participants (actual)
- Lead sponsor
- Hospital Universitari Vall d'Hebron Research InstituteUniversity, hospital or other
- Study start
- 27 Apr 2021 (actual)
- Primary completion
- 10 Aug 2021 (actual)
- Study completion
- 10 Aug 2021 (actual)
- First posted
- 16 Jul 2021 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
In patients with acute hypoxemic respiratory failure (AHRF), High Flow Nasal Therapy (HFNT) improves oxygenation, tolerance, and decrease work of breathing as compared to standard oxygen therapy by facemask. Current guidelines recommend adjusting oxygen flow rates to keep the oxygen saturation measured by pulse oximetry (SpO2) in the target range and avoid hypoxemia and hyperoxemia. The hypothesis of the study is that closed loop oxygen control increases the time spent within clinically targeted SpO2 ranges and decreases the time spent outside clinical target SpO2 ranges as compared to manual oxygen control in ICU patients treated with HFNT.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Crossover
- Masking
- Single blind (participant)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Oxygen close-loop | Experimental | Device: Oxygen close-loopFour hours period where the fraction of inspired oxygen delivered will be automatically titrated based on SpO2 values. |
| Manual FiO2 adjustment | Active comparator | Device: No interventionFour hours period where the fraction of inspired oxygen delivered will be manually adjusted by the healthcare personnel based on SpO2 values. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (3 listed)
- Adult (>17yo) patients admitted to the ICU treated with HFNT for at least 8h
- Requiring FiO2 ≥ 30% to keep SpO2 in the target ranges defined by the clinician
- Written informed consent signed and dated by the patient or one relative in case that the patient is unable to consent, after full explanation of the study by the investigator and prior to study participation.
Key exclusion criteria (13 listed)
- Patient with indication for immediate continuous positive airway pressure (CPAP), noninvasive ventilation (NIV), or invasive mechanical ventilation
- Hemodynamic instability defined as a need of continuous infusion of epinephrine or norepinephrine > 1 mg/h
- Low quality on the SpO2 measurement using finger and ear sensor (quality index below 60% on the Massimo SpO2 sensor, which is displayed by a red or orange colour bar)
- Severe acidosis (pH ≤ 7.30)
- Pregnant woman
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Oxygen close-loopThe Automatic FiO2 option provides automated adjustment of the ventilator Oxygen setting to maintain the patient's SpO2 in a defined target range. When using the software option, the user defines the SpO2 target range, as well as the SpO2 emergency limits, and the device adjusts the Oxygen setting to keep the patient's SpO2 in the target range. | Device | Oxygen close-loop |
| No interventionManual FiO2 adjustment according to SpO2 values | Device | Manual FiO2 adjustment |
Primary outcome
Percentage of time spent in optimal SpO2 range
Time frame: 4 hours
The optimal SpO2 range will be defined according to the SpO2 targets determined by the clinician.
12 secondary outcomes
Percentage of time spent in sub-optimal SpO2 range
Time frame: 4 hours
Percentage of time spent out of range
Time frame: 4 hours
Percentage of time with SpO2 signal available
Time frame: 4 hours
Mean SpO2/FiO2
Time frame: 4 hours
ROX index
Time frame: 4 hours
Percentage of time with SpO2 below 88 and 85 percent
Time frame: 4 hours
Number of events with SpO2 below 88 and 85 percent
Time frame: 4 hours
Mean FiO2
Time frame: 4 hours
Percentage of time with FiO2 below 40 percent and above 60%
Time frame: 4 hours
Number of manual adjustments
Time frame: 4 hours
Number of alarms
Time frame: 4 hours
Patient comfort
Time frame: 4 hours
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 9 Dec 2021.
- Background: PubMed 28729473L'Her E, Dias P, Gouillou M, Riou A, Souquiere L, Paleiron N, Archambault P, Bouchard PA, Lellouche F. Automatic versus manual oxygen administration in the emergency department. Eur Respir J. 2017 Jul 20;50(1):1602552. doi: 10.1183/13993003.02552-2016. Print 2017 Jul.
- Background: PubMed 25855899Helmerhorst HJ, Roos-Blom MJ, van Westerloo DJ, de Jonge E. Association Between Arterial Hyperoxia and Outcome in Subsets of Critical Illness: A Systematic Review, Meta-Analysis, and Meta-Regression of Cohort Studies. Crit Care Med. 2015 Jul;43(7):1508-19. doi: 10.1097/CCM.0000000000000998.
- Background: PubMed 28679200Arnal JM, Garnero A, Novotni D, Corno G, Donati SY, Demory D, Quintana G, Ducros L, Laubscher T, Durand-Gasselin J. Closed loop ventilation mode in Intensive Care Unit: a randomized controlled clinical trial comparing the numbers of manual ventilator setting changes. Minerva Anestesiol. 2018 Jan;84(1):58-67. doi: 10.23736/S0375-9393.17.11963-2. Epub 2017 Jul 5.
- Derived from this study: PubMed 35422002Roca O, Caritg O, Santafe M, Ramos FJ, Pacheco A, Garcia-de-Acilu M, Ferrer R, Schultz MJ, Ricard JD. Closed-loop oxygen control improves oxygen therapy in acute hypoxemic respiratory failure patients under high flow nasal oxygen: a randomized cross-over study (the HILOOP study). Crit Care. 2022 Apr 14;26(1):108. doi: 10.1186/s13054-022-03970-w.
- Individual participant dataSharing planned: No
Related trials for High Flow Nasal Cannula
Recruiting
Role of HFNC During FOB in Patients With Respiratory Failure
Respiratory Failure, Respiratory Failure With Hypercapnia
RecruitingObservational study
Brain-lung Interaction During Acute Respiratory Failure
Acute Respiratory Failure
Not yet recruiting
nCPAP Versus High-Flow Nasal Cannula in Preterm Infants With RDS
Respiratory Distress Syndrome, Premature Birth
Recruiting
HFNC Versus NIV in Hypercapneic COPD Patients
COPD (Chronic Obstructive Pulmonary Disease)
Recruiting
Physiological Effects of Continuous Negative External Pressure for Acute Hypoxemic Respiratory Failure
Acute Hypoxemic Respiratory Failure
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
The record lists no contact. Use the official record to reach the sponsor.
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Oxygen close-loop in people with High Flow Nasal Cannula and Oxygen Therapy, run by Hospital Universitari Vall d'Hebron Research Institute at 1 site in Spain.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 13 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 9 Dec 2021. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Spain. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Percentage of time spent in optimal SpO2 range (time frame: 4 hours). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT04965844, which also lists 4 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Dec 2021.