AzTrials
AzTrials

Hemodialysis Access FailureNCT05096416

Three-dimensional (3D) Printed Hemodialysis Vascular Model

A study testing The three-dimensional (3D) printed hemodialysis vascular model in people with Hemodialysis Access Failure, run by Brigham and Women's Hospital at 1 site in United States.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

Infiltration of a surgically-placed hemodialysis vascular access (HVA) is recognized as a major contributor to the high hospital re-admission rate in dialysis-dependent patients. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Hemodialysis Access Failure
What is being tested?
The three-dimensional (3D) printed hemodialysis vascular model
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
20 participants
Where
1 siteUnited States
Study dates
1 Jan 2023to 31 Jul 2026
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Patients with a surgically placed hemodialysis access which has been used in the last 90 days or is being prepared for use in the next 90 days

Who cannot join

  • Patients with only failed hemodialysis surgical access(es) that has/have not been used for >90 days.

Trial locations and contacts

1 site in 1 country.

Andrew Siedlecki, MD contact

+13148092879

asiedlecki@bwh.harvard.edu

Aliza Anwar Memon, MBBS contact

+13479824073

aamemon@bwh.harvard.edu

United States1 site
  • Brigham and Women's Hospital

    Boston, Massachusetts, 02115

Other trials in United States

About this study

Official title: Three-dimensional (3D) Printed Hemodialysis Vascular Model for Increased Precision of Cannulation

Infiltration of a surgically-placed hemodialysis vascular access (HVA) is recognized as a major contributor to the high hospital re-admission rate in dialysis-dependent patients. Three dimensional modeling has been demonstrated as a critical tool for procedurists in preparation for surgical interventions but no such modeling is yet available for dialysis specialists to avoid the common complication of HVA infiltration. Contrast enhanced magnetic resonance angiography (MRA) can be used to generate a three dimensional image data that could render a three dimensional resin-based model of a vascular access.

Read the detailed description

Hemodialysis is the most common treatment for End Stage Renal Disease (ESRD). For an optimal renal replacement therapy, a patent vascular access (VA) is essential. The importance of good vascular access maintenance has been strongly supported by the guidelines (1). Various hinderances render this goal unachievable. A well-known cause of VA failure is access infiltration, which is usually overlooked in clinical practices (2). The calculated economic burden attributable to VA complication is between $16,864 -US$20,961 and more than 50% is due to access infiltration alone (3). Imaging has a pivotal pre- and post-operative role in evaluating vascular access complications. Imaging modalities such as ultrasound (US), Digital Subtraction Angiography (DSA) and Magnetic Resonance Angiography (MRA) are available but their use is limited due to the limited view of plane available for visualization of vessel anatomy(4) and because of the deleterious side effects of the contrast agents used (5,6). Contrast enhanced Magnetic Resonance Angiography (MRA) provides an excellent means of imaging the vasculature (7) which can be reconstructed in a three- dimensional(3D) print. The skill set of dialysis technician nurses play a considerable role in achieving successful cannulation of the fistula. Due oftentimes to complicated vascular anatomy, cannulation based on cutaneous anatomic landmarks and physical examination can be deceiving. Even a minor error in cannulation can impair access longevity(3). The 3D image reconstruction provides a practical solution to generate a 3D VA model which can be used by the procedurists to cannulate the patients, reducing the complications and rate of re admissions. Overall, a significant reduction in the health care cost can be achieved

Being tested
The three-dimensional (3D) printed hemodialysis vascular model
Keywords
hemodialysis, Magnetic resonance angiography, three-dimensional (3D) printed hemodialysis vascular model, Vascular access complication

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • The three-dimensional (3D) printed hemodialysis vascular modelDevice

    The three-dimensional (3D) printed hemodialysis vascular model will be used as a guide map to cannulate the patients for hemodialysis and to minimize the risk of vascular access complications

Study groups in NCT05096416
Study groupRoleWhat they receive
Control armNo interventionPatients in this arm will have standard of care where they will be annulated by the palpation method by the dialysis technician and nurse.
Intervention armExperimentalPatients in this arm will have a three-dimensional (3D) printed vascular access model to assist the dialysis technician and nurse in cannulation.
Receives: Device: The three-dimensional (3D) printed hemodialysis vascular model

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Quantify the number of dialysis treatments completed

    Measured: 12 month

Secondary outcomes (2)
  1. Quantify the number of vascular access interventions over a 12-month period compared to controls

    Measured: 12 month

  2. Quantify annual hospitalization rate compared to controls

    Measured: 12 month

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted27 Oct 2021
  2. Study start1 Jan 2023 (estimated)
  3. Primary completion31 Jul 2026 (estimated)
  4. Study completion31 Jul 2026 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Prevention
Allocation
Randomised
Intervention model
Parallel groups
Masking
None (open label)
Enrolment
20 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05096416
Sponsor's protocol ID
2022P000658
Status last verified
Jul 2022
First submitted
15 Oct 2021
Last updated
2 Aug 2022
Results posted
No
Data monitoring committee
Yes
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing The three-dimensional (3D) printed hemodialysis vascular model in people with Hemodialysis Access Failure, run by Brigham and Women's Hospital at 1 site in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 1 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 2 Aug 2022. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Andrew Siedlecki, MD (+13148092879, asiedlecki@bwh.harvard.edu), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Quantify the number of dialysis treatments completed (time frame: 12 month). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 2 Aug 2022; AzTrials last refreshed its copy on 29 Oct 2026.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in