AzTrials
AzTrials

KeratoconusNCT05161052

Assessment of Corneal Stiffness in Keratoconus After Crosslinking by Corvis ST and OCT.

A study testing Corvis ST (dynamic Scheimpflug technology) in people with Keratoconus, run by Cairo University.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

Objectives: Measurement of corneal stiffness parameters { Deformation Amlitude (DAR1), Integrated radius, Stress parameter (SP A1), Stress strain index (SSI) and Corvis biomechanical index (CBI) } in keratoconic corneas before and after 3 and 6 months CXL using Corvis ST. Read more about this study

Who is it for?
Ages 18 to 40 yearsHealthy volunteers can take part
Conditions the study is for
Keratoconus
What is being tested?
Corvis ST (dynamic Scheimpflug technology)
Type of treatment
Medical device
How many people
55 participants
Where
No sites listed yet
Study dates
1 Jan 2022to 1 Feb 2023
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 40 years
  • All sexes
  • Healthy volunteers accepted
  • Adult

Who may be able to join

  • Patients with documented progressive keratoconus within one year include any of the following:
  • ≥ 1.00 diopter increase in maximal keratometry (Kmax). B. ≥ 1.00 diopter increase in the manifest cylinder. C. ≥ 0.75 diopter increase in average of Kmax and Kmin (Kmean). D. ≥ 2% decrease in central thickness. E. ≥ 1.50 diopter increase in the central K power from baseline. F. ≥ 1.0 diopter increase in manifest spherical equivalent change (MRSE).
  • All patients have minimal corneal stromal thickness 400 μm before UVA irradiation.

Who cannot join

  • Patients with corneal rings.
  • Advanced keratoconus with corneal scarring.
  • History of herpetic keratitis and severe corneal infection.
  • Pregnancy or breastfeeding.
  • The use of rigid contact lens¬es for more than 4 weeks before the baseline evaluation.

Trial locations and contacts

No sites are listed yet.

Mohamed Elnoamany, MD contact

01222536367

mohamedelnoamany1@gmail.com

Mohamed Fakhry, MD contact

01006678788

fakhryref@hotmail.com

About this study

Official title: Assessment of Corneal Stiffness Parameters in Keratoconus After Corneal Collagen Cross Linking Using Dynamic Scheimpflug Technology and Anterior Segment Optical Coherence Tomography.

Objectives:

  • Measurement of corneal stiffness parameters { Deformation Amlitude (DAR1), Integrated radius, Stress parameter (SP A1), Stress strain index (SSI) and Corvis biomechanical index (CBI) } in keratoconic corneas before and after 3 and 6 months CXL using Corvis ST.
  • Measurement of demarcation line depth using anterior segment OCT and correlate between corneal stiffness following CXL and demarcation line depth.
Read the detailed description

Background and Rationale:

Keratoconus is a progressive corneal degeneration resulting from noninflammatory thinning of the corneal stroma. Visual impairment typically commences in adolescence and progresses thereafter. Further increase in myopia, irregular astigmatism, and subepithelial scarring leads to visual impairment. Treatment modalities are based on refractive correction with spectacles or contact lenses to correct astigmatism and restore visual acuity. Such modalities do not stop ectatic progression and further visual deterioration, which ultimately necessitates corneal transplantation in 10% to 20% of patients.

Corneal collagen cross-linking (CXL) has emerged as a promising techniq;ue to slow or halt the progression of keratoconus. CXL leads to an increase in intra and interfibrillar covalent bonds by photosensitized oxidation and causes a biomechanical stabilization of the cornea.

Corneal visualization using dynamic Scheimpflug technology (Corvis ST, Oculus Optikger€ate GmbH) allows in vivo measurement of the corneal biomechanical deformation response to an applied air puff and is useful for evaluating the biomechanical response parameters of the cornea. It captures the dynamic corneal deformation caused by an air puff using an ultrahigh- speed camera that operates at a speed of greater than 4300 frames per second to capture a series of 140 sequential horizontal Scheimpflug images of the temporal-nasal cross section of the cornea. The consistency of the air puff has been shown and the spatial and temporal profiles have been characterized to allow calculation of the load on the cornea within the imaging window.

The Corvis ST enables the measurement of several parameters by analyzing the timing and patterns of deformation at the highest concavity as well as applanation during inward deformation (loading) and outward recovery (unloading). The original parameters have been reported to be influenced most strongly by intraocular pressure (IOP) as well as age and central corneal thickness (CCT). Recently, new corneal biomechanical parameters were introduced, including the Deformation Amplitude ratio at 1.0 mm (DAR1), Deformation Amplitude ratio at 2.0 mm (DAR2), Integrated radius, Stiffness Parameter at first applanation (SP A1), Ambrosio's Relational Thickness (ARTH) , Corbic Biomechanical index (CBI) and biomechanically corrected IOP (bIOP).

Laboratory studies have shown that the effective depth of CXL is confined to the anterior 300 μm of the cornea. Moreover, a stromal demarcation line between treated and untreated stroma was visible biomicroscopically at a depth of approximately 300 μm over the entire cornea after CXL treatment. This demarcation line was also evident on optical coherence tomography (OCT). The depth of this line has been postulated as an indirect measurement of cross-linking effectiveness.

Conditions
Keratoconus
Being tested
Corvis ST (dynamic Scheimpflug technology)
Medical subject headings
Keratoconus

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Corvis ST (dynamic Scheimpflug technology)Device

    Also called OCT (Optical Coherence tomography)

    • Measurement of corneal stiffness parameters { Deformation Amlitude (DAR1), Integrated radius, Stress parameter (SP A1), Stress strain index (SSI) and Corvis biomechanical index (CBI) } in keratoconic corneas before and after 3 and 6 months CXL using Corvis ST.
    • Measurement of demarcation line depth using anterior segment OCT and correlate between corneal stiffness following CXL and demarcation line depth

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Measuring changes in corneal stiffness parameters in keratoconus after CXL by Corvis ST which measures corneal stiffness parameters.

    Measurement of changes in corneal stiffness parameters { Deformation Amplitude (DAR1), Integrated radius, Stress parameter (SP A1), Stress strain index (SSI) and Corvis biomechanical index (CBI) } before and after crosslinking procedure to measure corneal stiffness.

    Measured: Before crosslinknig procedure and after 3, 6 months using Corvis ST.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted16 Dec 2021
  2. Study start1 Jan 2022 (estimated)
  3. Primary completion1 Jan 2023 (estimated)
  4. Study completion1 Feb 2023 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Randomised
Intervention model
Single group
Model description
* Measurement of corneal stiffness parameters { Deformation Amplitude (DAR1), Integrated radius, Stress parameter (SP A1), Stress strain index (SSI) and Corvis biomechanical index (CBI) } in keratoconic corneas before and after 3 and 6 months CXL using Corvis ST. * Measurement of demarcation line depth using anterior segment OCT and correlate between corneal stiffness following CXL and demarcation line depth.
Masking
None (open label)
Enrolment
55 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05161052
Sponsor's protocol ID
MD-80-2021
Status last verified
Dec 2021
First submitted
19 Oct 2021
Last updated
16 Dec 2021
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No

Publications

  • Salouti R, Bagheri M, Shamsi A, Zamani M. Corneal Parameters in Healthy Subjects Assessed by Corvis ST. J Ophthalmic Vis Res. 2020 Feb 2;15(1):24-31. doi: 10.18502/jovr.v15i1.5936. eCollection 2020 Jan-Mar.

    PubMed 32095205
  • Nakao Y, Kiuchi Y, Okumichi H. Evaluation of biomechanically corrected intraocular pressure using Corvis ST and comparison of the Corvis ST, noncontact tonometer, and Goldmann applanation tonometer in patients with glaucoma. PLoS One. 2020 Sep 23;15(9):e0238395. doi: 10.1371/journal.pone.0238395. eCollection 2020.

    PubMed 32966284
  • Herber R, Terai N, Pillunat KR, Raiskup F, Pillunat LE, Sporl E. [Dynamic Scheimpflug Analyzer (Corvis ST) for measurement of corneal biomechanical parameters : A praxis-related overview]. Ophthalmologe. 2018 Aug;115(8):635-643. doi: 10.1007/s00347-018-0716-y. German.

    PubMed 29767348

Questions about this trial

What is this clinical trial studying?

A study testing Corvis ST (dynamic Scheimpflug technology) in people with Keratoconus, run by Cairo University.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 16 Dec 2021. Status can change between updates, so confirm with the study contact before making plans.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Mohamed Elnoamany, MD (01222536367, mohamedelnoamany1@gmail.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Measuring changes in corneal stiffness parameters in keratoconus after CXL by Corvis ST which measures corneal stiffness parameters. (time frame: Before crosslinknig procedure and after 3, 6 months using Corvis ST.). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT05161052, which also lists 3 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 16 Dec 2021.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in