ACURATE Prime XL Human Feasibility Study

A study testing ACURATE Prime XL Transfemoral Aortic Valve System in people with Aortic Stenosis, run by Boston Scientific Corporation at 3 sites in Australia.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

To evaluate feasibility and safety of the ACURATE Prime™ XL Transfemoral Aortic Valve System for transcatheter aortic valve implantation (TAVI) in subjects with severe native aortic stenosis who are indicated for TAVI. Read more about this study

Who is it for?
Any age
Conditions the study is for
Aortic Stenosis
What is being tested?
ACURATE Prime XL Transfemoral Aortic Valve System
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
13 participants
Where
3 sitesAustralia
Study dates
3 Mar 2022to 24 May 2023
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages Any age
  • All sexes
  • No healthy volunteers
  • Child, Adult, Older adult

Who may be able to join

  • IC1. Subject has documented severe symptomatic native aortic stenosis defined as follows: aortic valve area (AVA) ≤1.0 cm2 (or AVA index ≤0.6 cm2/m2) AND a mean pressure gradient ≥40 mmHg, OR maximal aortic valve velocity ≥4.0 m/s, OR Doppler velocity index ≤0.25 as measured by echocardiography and/or invasive hemodynamics. Note: In cases of low flow, low gradient aortic stenosis with left ventricular dysfunction (ejection fraction <50%), dobutamine can be used to assess the grade of aortic stenosis (maximum dobutamine dose of 20 mcg/kg/min recommended); the subject may be included in the study if echocardiographic criteria are met with this augmentation.
  • IC2. Subject has a documented aortic annulus diameter of ≥26.5 mm and ≤29 mm based on the center's assessment of pre-procedure diagnostic imaging (and confirmed by the Case Review Committee [CRC]).
  • IC3. For subjects with symptomatic aortic valve stenosis per IC1 definition above, functional status is NYHA Functional Class ≥ II.
  • IC4. Heart team (composition per local standards, but at a minimum must include an experienced cardiac surgeon) agrees that the subject is indicated for TAVI, is likely to benefit from prosthetic valve implantation, and TAVI is appropriate.
  • IC5. Subject (or legal representative) understands the study requirements and the treatment procedures and provides written informed consent.
  • IC6. Subject, family member, and/or legal representative agree(s) and subject is capable of returning to the study hospital for all required scheduled follow up visits.
  • IC7. Subject is expected to be able to take the protocol-required adjunctive pharmacologic therapy.

Who cannot join

  • EC1. Subject has a unicuspid or bicuspid aortic valve.
  • EC2. Subject has had an acute myocardial infarction within 30 days prior to the index procedure (defined as Q-wave MI or non-Q-wave MI with total CK elevation ≥ twice normal in the presence of CK MB elevation and/or troponin elevation).
  • EC3.Subject has had a cerebrovascular accident or transient ischemic attack clinically confirmed by a neurologist or neuroimaging within the past 6 months prior to study enrollment.
  • EC4.Subject has eGFR < 20 mL/min (based on hospital preferred method) but is not on renal replacement therapy.
  • EC5. Subject has a pre-existing prosthetic aortic or mitral valve.
  • EC6. Subject has severe (4+) aortic, tricuspid, or mitral regurgitation.
Show all 30Show fewer
  • EC7. Subject has moderate or severe mitral stenosis (mitral valve area ≤1.5 cm2 and diastolic pressure half-time ≥150 ms, Stage C or D).
  • EC8. Subject has a need for emergency surgery for any reason.
  • EC9. Subject has a history of endocarditis within 6 months of index procedure or evidence of an active systemic infection or sepsis.
  • EC10. Subject has echocardiographic evidence of new intra-cardiac vegetation or intraventricular or paravalvular thrombus requiring intervention.
  • EC11. Subject has platelet count <50,000 cells/mm3 or >700,000 cells/mm3, or white blood cell count <1,000 cells/mm3.
  • EC12. Subject has had a gastrointestinal bleed requiring hospitalization or transfusion within the past 3 months or has other clinically significant bleeding diathesis or coagulopathy that would preclude treatment with required antiplatelet regimen or will refuse transfusions.
  • EC13. Subject has known hypersensitivity to the following:
  • Contrast agents that cannot be adequately pre-medicated, OR
  • Protocol-required medications (aspirin, all P2Y12 inhibitors, heparin), OR
  • Individual components of the investigational valve and/or delivery system (stainless steel, platinum, iridium, nickel, titanium, or polyethylene terephthalate [PET]).
  • EC14. Subject has a life expectancy of less than 12 months due to non-cardiac, comorbid conditions based on the assessment of the investigator at the time of enrollment.
  • EC15. Subject has hypertrophic cardiomyopathy.
  • EC16. Subject has any therapeutic invasive cardiac or vascular procedure within 30 days prior to the index procedure (except for balloon aortic valvuloplasty, pacemaker implantation, or implantable cardioverter defibrillator implantation, which are allowed).
  • EC17. Subject has untreated coronary artery disease, which in the opinion of the treating physician is clinically significant and requires revascularization.
  • EC18. Subject has severe left ventricular dysfunction with ejection fraction <20%.
  • EC19. Subject is in cardiogenic shock or has hemodynamic instability requiring inotropic support or mechanical support devices.
  • EC20. Subject has arterial access that is not acceptable for the study device delivery system as defined in the Instructions For Use.
  • EC21. Subject has either of the following:
  • Severe vascular disease that would preclude safe access (e.g., aneurysm with thrombus that cannot be crossed safely; marked tortuosity; significant narrowing of the abdominal aorta; severe unfolding of the thoracic aorta; or thick, protruding, ulcerated atheroma in the aortic arch), OR
  • Severe/eccentric calcification of the aortic annulus that would prevent safe implantation of the TAVI prosthesis.
  • EC22. Subject has current problems with substance abuse (e.g., alcohol, etc.) that may interfere with the subject's participation in this study.
  • EC23. Subject is participating in another investigational drug or device study that has not reached its primary endpoint or subject intends to participate in another investigational device clinical trial within 12 months after the index procedure.
  • EC24. Subject has untreated conduction system disorder (e.g., Type II second degree atrioventricular block) that in the opinion of the treating physician is clinically significant and requires a pacemaker implantation. Enrollment is permissible after permanent pacemaker implantation.
  • EC25. Subject has severe incapacitating dementia.

Trial locations and contacts

3 sites in 1 country.

Australia3 sites
  • The Prince Charles Hospital

    Brisbane, Queensland, 4032

  • Royal Prince Alfred Hospital

    Camperdown, New South Wales, 2050

  • Monash Health

    Clayton, Victoria, 3168

Other trials in Australia

About this study

Official title: A Study to Evaluate the Feasibility and Safety of the ACURATE Prime™ XL Aortic Valve System in Patients Indicated for TAVI: ACURATE Prime XL Human Feasibility Study

To evaluate feasibility and safety of the ACURATE Prime™ XL Transfemoral Aortic Valve System for transcatheter aortic valve implantation (TAVI) in subjects with severe native aortic stenosis who are indicated for TAVI.

Read the detailed description

The ACURATE Prime XL Human Feasibility Study (ACURATE Prime XL HFS) is a prospective, multicenter, open-label, single-arm study designed to evaluate feasibility and safety of the ACURATE Prime XL Transfemoral Aortic Valve System for TAVI in subjects who have severe native aortic stenosis and are indicated for TAVI.

Subjects who provide written informed consent, meet all eligibility criteria, and are approved by the Case Review Committee (CRC) are considered enrolled when an attempt is made to insert the iSLEEVE Introducer into the subject's femoral artery. There will be up to 20 subjects enrolled at up to 6 centers in Australia and Europe.

All subjects implanted with a study valve will be assessed at baseline, peri- and post-procedure, at discharge or 7 days post index procedure (whichever comes first), 30 days, 6 months, and 1 year. Subjects who are enrolled but not implanted with a study valve at the time of the procedure will be followed for safety through 30 days.

Conditions
Aortic Stenosis
Being tested
ACURATE Prime XL Transfemoral Aortic Valve System
Keywords
ACURATE Prime™ XL Aortic Valve System
Medical subject headings
Aortic Valve Stenosis

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • ACURATE Prime XL Transfemoral Aortic Valve SystemDevice

    ACURATE Prime™ Transfemoral Aortic Valve system: Support frame made of nitinol, supra-annular processed tri-leaflet porcine pericardial valve and an outer skirt to limit paravalvular regurgitation (manufactured by Boston Scientific Corporation, Marlborough, MA, USA).

Study groups in NCT05224245
Study groupRoleWhat they receive
Single arm: ACURATE Prime XL Transfemoral Aortic Valve SystemExperimentalSubjects who provide written informed consent, meet all eligibility criteria, and are approved by the Case Review Committee (CRC) will be implanted with ACURATE Prime XL Transfemoral Aortic Valve using iSLEEVE, ACURATE Prime XL Delivery System and ACURATE Prime XL Loading kit
Receives: Device: ACURATE Prime XL Transfemoral Aortic Valve System

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Number of participants with Device Success

    Absence of procedural mortality, AND Correct positioning of a single valve into the proper anatomical location, AND Intended performance of the study device (indexed effective orifice area [iEOA] >0.85 cm2/m2 for BMI <30 kg/m2 and iEOA >0.70 cm2/m2 for BMI ≥30 kg/m2 plus either a mean aortic valve gradient <20 mmHg or a peak velocity <3m/sec, and no moderate or severe prosthetic valve aortic regurgitation) as measured by transthoracic echocardiography (TTE) and assessed by an independent core laboratory.

    Measured: Through discharge or 7 days post procedure

  2. Number of participants who died or experienced a stroke

    Composite of all-cause mortality and all stroke

    A Clinical Events Committee (CEC), independent group of physician experts will be used to evaluate all reported cases of death and stroke to determine whether they met the specific protocol definition of the event.

    Measured: Through 30 Days post procedure

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted4 Feb 2022
  2. Study start3 Mar 2022
  3. Primary completion16 Jun 2022
  4. Study completion24 May 2023

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Device feasibility
Allocation
Not applicable
Intervention model
Single group
Model description
The protocol allows for up to 20 patients to be enrolled.
Masking
None (open label)
Enrolment
13 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05224245
Sponsor's protocol ID
S2458
Status last verified
Jun 2023
First submitted
4 Jan 2022
Last updated
15 Jun 2023
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
Undecided: The data and study protocol for this clinical trial may be made available to other researchers in accordance with the Boston Scientific Data Sharing Policy (http://www.bostonscientific.com/en-US/data-sharing-requests.html)

Publications

  • Gooley R, Murdoch D, Ng MK, Modolo R, Allocco DJ. First results from the ACURATE Prime XL human feasibility study. Cardiovasc Revasc Med. 2023 Dec;57:1-5. doi: 10.1016/j.carrev.2023.06.028. Epub 2023 Jun 30.

    PubMed 37429793

Questions about this trial

What is this clinical trial studying?

A study testing ACURATE Prime XL Transfemoral Aortic Valve System in people with Aortic Stenosis, run by Boston Scientific Corporation at 3 sites in Australia.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 7 inclusion and 30 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 15 Jun 2023. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 3 sites in Australia. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Number of participants with Device Success (time frame: Through discharge or 7 days post procedure). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT05224245, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 15 Jun 2023.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in