CataractNCT05304182

Clinical Study - ES 900 - 2020-1

A study testing EYESTAR 900 and LENSTAR LS 900 in people with Cataract, run by Haag-Streit AG at 1 site in India.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

EYESTAR 900 is a device developed by Haag-Streit which utilises 3D OCT for quantitative measurements of the geometry of the entire eye, including ocular biometry and corneal topography. Read more about this study

Who is it for?
Ages 35 years and older
Conditions the study is for
Cataract
What is being tested?
EYESTAR 900 and LENSTAR LS 900
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
50 participants
Where
1 siteIndia
Study dates
1 Jul 2022to 28 Feb 2024
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 35 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • voluntary participation
  • informed consent
  • 35 years of age or older

Who cannot join

  • ineligibility for cataract surgery for any reason, e.g., aphakia
  • Disqualifying pathologies:
  • keratoconus
  • corneal astigmatism of more than 3.5 D
  • history of recurrent inflammation or infection of the eye
  • Disqualifying corneal conditions:
Show all 18Show fewer
  • comorbidities,
  • deformations,
  • lesions, or
  • scarring of the cornea
  • acute inflammation or infection of the eye
  • Disqualifying treatments:
  • previous refractive surgeries, including PRK and LASIK
  • previous corneal surgeries
  • previous corneal transplants
  • previous intraocular surgeries
  • Disqualifying outcomes:
  • failed IOL implantation into the capsular bag

Trial locations and contacts

1 site in 1 country.

India1 site
  • Aravind Eye Hospitals

    Chennai, Tamil Nadu, 600077

    Nivetha K, chennai.research@aravind.org

    Haripriya Aravind, MD

Other trials in India

About this study

EYESTAR 900 is a device developed by Haag-Streit which utilises 3D OCT for quantitative measurements of the geometry of the entire eye, including ocular biometry and corneal topography. It is the most recent in a series of successful biometry devices by Haag-Streit (HS Pachymeter, Lenstar LS 900, LS 900 T-cone and LS 900 APS) and also allows for advanced corneal tomography examinations. The EYESTAR 900 is CE marked.

These measurement results of this device are used for the planning of the medical treatment of patients. Depending on the application, the benefits of this device may include improved visual acuity (after cataract surgery), reduced risk of complications (after refractive surgery or implant of a phakic intraocular lens), early identification of pathological deformations of the cornea (keratoconus detection).

Read more

The primary objective of this clinical trial is to assess the clinical performance of the investigational device in dense cataracts. To that end, for each measurand, the in-vivo repeatability will be quantified, as well as limits of agreement and the mean measurement deviation, with respect to the current gold standard device.

As a secondary objective of the study, raw measurement data will be collected to allow for the improvement of existing algorithms, development of additional measurands and for retrospective analysis.

No diseases are studied.

Read the detailed description

The EYESTAR 900 is a non-contact device for measuring the human eye, consisting of a swept source OCT sub-unit (OCT: optical coherence tomography, a measurement method to acquire tomographic images by optical interferometry) and an imaging system sub-unit.

The OCT sub-unit performs a three-dimensional measurement of all refractive ocular structures in the anterior eye segment (curvatures and locations of the anterior corneal surface, posterior corneal surface, the anterior crystalline lens surface, posterior crystalline lens surface), as well as a one-dimensional measurement of axial eye length. It also generates cross-sectional images of the anterior eye section and the central retina. The measurement is implemented by scanning the eye with a low-power near-infrared laser beam and measuring the light which is back-reflected to the device.

The imaging system sub-unit is used to obtain photographic images of the eye. Based on these images, the keratometry (anterior corneal curvature of the steepest and flattest meridian), the white-to-white distance and the pupil diameter are measured. Additionally, these images can serve to document the locations of special landmarks on the eye, such as blood vessels. The imaging system sub-unit is based on conventional digital photography technology. Illumination for imaging is provided by infrared and white-light LEDs (light emitting diodes). Measurement of keratometry additionally requires measuring the distance to the eye using the OCT sub-unit.

The EYESTAR 900 is designed as standalone-device with integrated PC (personal computer) and display for device operation, measurement acquisition and processing, and presentation of the measurement results. After a patient is placed in front of the device and the chin rest is adjusted, the device can perform the remaining positioning procedures and acquire the measurements in a fully automated manner. Position information is derived from the OCT and digital camera system sub-units.

Both implemented measuring methods, optical coherence tomography (OCT), as well as digital photography are non-invasive, contactless methods. OCT uses a laser beam of λ=1060nm central wavelength and less than 2 mW optical power, which is focussed to a beam diameter of approximately 80µm at the anterior lens plane, and is continuously scanned in the lateral direction. Digital photography uses diffuse illumination of the eye by white-light LEDs (425nm ≤ λ ≤ 725nm) and infrared LEDs with central wavelength λ=850nm. All light sources emit levels that comply with ISO 15004-2 ("Ophthalmic Instruments - Fundamental requirements and test methods - Part 2: Light hazard protection"), under normal operating conditions as well as in case of a single fault condition.

The main application of this device is to acquire biometric measurements of cataractous eyes which are used to calculate suitable intraocular lens power and dimension.

The patient population must be capable of sitting up straight and keeping their head still and their eyes opened. They must be physically and mentally able to cooperate and mentally capable of following the examination. Patients must be at least 18 years old.

The target device user is an ophthalmologist or a trained specialist.

The investigational device EYESTAR 900 is developed and manufactured by HAAG-STREIT AG, Koeniz (Switzerland).

For the duration of the examination (approximately 1-2 minutes), the patient is in contact with the device at following applied parts:

  1. the chin rest shell (Edistir RK451 G naturally coated with HAERATEX Aqua 2K-structural coater BW89 10K RAL 9005);
  2. the forehead rest band (Saxamid 126-N001 uncoated PA6 white FK 6659 PA);
  3. (depending on the subject's requirements) the patient handles (aluminium EN AW-6060 (AlMgSi 0.5) colourless anodized class 20 with sealing chemically polished and sandblasted).

No other contact with body tissues or fluids takes place. No critical biocompatibility issues were identified.

Conditions
Cataract
Being tested
EYESTAR 900, LENSTAR LS 900
Keywords
Optical Biometry, Corneal Topography
Medical subject headings
Cataract

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • EYESTAR 900Device

    Also called Optical Biometer

    The EYESTAR 900 is a device developed by Haag-Streit which utilises 3D OCT for quantitative measurements of the geometry of the entire eye, including ocular biometry and corneal topography. It is the most recent in a series of successful biometry devices by Haag-Streit (HS Pachymeter, Lenstar LS 900, LS 900 T-cone and LS 900 APS) and also allows for advanced corneal tomography examinations.

  • LENSTAR LS 900Device

    Also called Optical Biometer

    The LENSTAR LS 900 is a non-contact device for measurement of biometrical parameters of the eye, aimed to assist the calculation of intraocular lenses (IOLs) prior to intraocular lens implantation. The most common application is in preparation of cataract surgery.

    This device uses OLCR (optical low-coherence reflectometry), an interferometric method to measure intraocular axial distances. Furthermore, it uses digital photography of the anterior section of the eye to measure pupil size and location, as well as the white-to-white distance of the eye. The same photographic unit, in conjunction with a specific illumination pattern, is used to measure the corneal curvature - this measurement is known as 'keratometry', or, more specifically, 'automated keratometry'.

Study groups in NCT05304182
Study groupRoleWhat they receive
Pre-OpExperimentalThe experimental intervention is non-invasive optical imaging, in particular digital photography and optical coherence tomography, conducted with the investigational and comparator device, for the purpose of measuring dimensions of the eye.
Receives: Device: EYESTAR 900; Device: LENSTAR LS 900
Post-OpActive comparatorThe experimental intervention is non-invasive optical imaging, in particular digital photography and optical coherence tomography, conducted with the investigational and comparator device, for the purpose of measuring dimensions of the eye.
Receives: Device: EYESTAR 900; Device: LENSTAR LS 900

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Dense Cataract Performance

    The primary outcome is the performance of the EYESTAR 900 in dense cataracts. Specifically, the highest grade of cataract at which complete measurements can reliably be performed and, consequently, the number of patients measured successfully.

    Measured: 18 months

Secondary outcomes (12)
  1. Keratometry

    The limits of agreement and the confidence interval of difference in comparison with the LENSTAR 900.

    Measured: 18 months

  2. Axial Length

    The limits of agreement and the confidence interval of difference in comparison with the LENSTAR 900.

    Measured: 18 months

  3. White-to-White Imaging

    The limits of agreement and the confidence interval of difference in comparison with the LENSTAR 900.

    Measured: 18 months

  4. Anterior Corneal Elevation

    The limits of agreement and the confidence interval of difference in comparison with the LENSTAR 900.

    Measured: 18 months

  5. Anterior Corneal Axial Curvature

    The limits of agreement and the confidence interval of difference in comparison with the LENSTAR 900.

    Measured: 18 months

  6. Anterior Corneal Tangential Curvature

    The limits of agreement and the confidence interval of difference in comparison with the LENSTAR 900.

    Measured: 18 months

  7. Posterior Corneal Elevation

    The limits of agreement and the confidence interval of difference in comparison with the LENSTAR 900.

    Measured: 18 months

  8. Posterior Corneal Axial Curvature

    The limits of agreement and the confidence interval of difference in comparison with the LENSTAR 900.

    Measured: 18 months

  9. Posterior Corneal Tangential Curvature

    The limits of agreement and the confidence interval of difference in comparison with the LENSTAR 900.

    Measured: 18 months

  10. Corneal Pachymetry

    The limits of agreement and the confidence interval of difference in comparison with the LENSTAR 900.

    Measured: 18 months

  11. Simulated Anterior Keratometry

    The limits of agreement and the confidence interval of difference in comparison with the LENSTAR 900.

    Measured: 18 months

  12. Simulated Posterior Keratometry

    The limits of agreement and the confidence interval of difference in comparison with the LENSTAR 900.

    Measured: 18 months

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted31 Mar 2022
  2. Study start1 Jul 2022 (estimated)
  3. Primary completion30 Dec 2023 (estimated)
  4. Study completion28 Feb 2024 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Diagnosis
Allocation
Non-randomised
Intervention model
Crossover
Model description
There are two identical arms in this study: pre-operative and post-operative. Every participant starts in the pre-operative arm and crosses over to the post-operative arm. During both arms, each study subject undergoes the experimental intervention and the control intervention. The study objective is to assess the clinical performance of the investigational device. This assessment is performed by a statistical analysis of the measurement results from the experimental intervention and the control intervention. The surgery is not a study intervention.
Masking
None (open label)
Enrolment
50 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05304182
Sponsor's protocol ID
1023703
Status last verified
Jun 2022
First submitted
22 Mar 2022
Last updated
29 Jun 2022
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing EYESTAR 900 and LENSTAR LS 900 in people with Cataract, run by Haag-Streit AG at 1 site in India.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 18 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 29 Jun 2022. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in India. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Rachit Bhandary (+91 40 24891250, rachit@biomedixdevices.com), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Dense Cataract Performance (time frame: 18 months). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 29 Jun 2022.

Free account

Keep searching with a free account

You’ve used your 3 free searches for this session. Log in or create a free AzTrials account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in
Clinical Study - ES 900 - 2020-1 (NCT05304182) | AzTrials