Arthroplasty, Replacement, KneeiNAVNCT05325060
Navigated Versus Convention Total Knee Arthroplasty
A study testing Electromagnetically navigated total knee arthroplasty and Conventional total knee arthroplasty in people with Arthroplasty, Replacement, Knee and Surgery, Computer-Assisted, run by NHS Greater Glasgow and Clyde.
Trial summary
The aim of this single blinded randomised control trial study was to assess the accuracy of implantation of components and the clinical outcome and complications with the iNAV electromagnetic navigation system compared with conventional techniques. Read more about this study
- Who is it for?
- Ages 18 to 120 years
- Conditions the study is for
- Arthroplasty, Replacement, Knee, Surgery, Computer-Assisted
- What is being tested?
- Electromagnetically navigated total knee arthroplasty and Conventional total knee arthroplasty
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 200 participants
- Where
- No sites listed yet
- Study dates
- 25 Jun 2007to 2 Jul 2021
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 to 120 years
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Male or female subjects
- Subjects must be at least 18 years of age and there will be no maximum age limit. The subjects age must be considered suitable by the Investigator for a knee arthroplasty using either of the two systems available in the evaluation.
- Subjects, who are able to give voluntary, written informed consent to participate in this investigation and from whom consent has been obtained.
- Subjects, who, in the opinion of the investigator, are able to understand this investigation, co-operate with the investigation procedures and are willing to return to the hopsital for all the required post-operative follow-ups.
- Subjects who require a knee arthroplasty for primary surgical management of the idiopathic osteoarthritis.
- Subjects, who in the opinion of the Investigator, are considered to be suitable for treatment with a NexGen LPS Flex Total Knee Replacement.
Who cannot join
- Subjects who, in the opinion of the investigator, have an existing condition that would compromise their participation and follow-up in the study
- Subjects who require revision total knee arthroplasty surgery
- Subjects with any tibial deformity requiring tibial component augmentation.
- Subjects whom, in the opinion of the Investigator, require a constratined prosthesis.
- Subjects with inflammatory polyarthritis.
- Subjects with disorders of the feet, ankles, hips, or spine caising significant abnormal gait or significant pain.
Show all 16Show fewer
- Subjects with osteoarthritis of the contralateral knee causing significant abnormal gait or significant pain.
- Subjects with poorly functioning contralateral total knee replacement causing significant abnormal gait or significant pain. Subjects with a well functioning contralateral total knee replacement will not be excluded.
- Subjects with neurological conditions affecting movement.
- Subjects with a pathology which, in the opinion of the Investigator, will adversely affect healing.
- Subjects with other disorders which, in the opinion of the Investigator, will/could impair rehabilitation.
- Contra-indications for the use of the device, as detailed in the package insert.
- Women who are pregnant
- Subjects who are known drug or alcohol abusers or with psychological disorders that could effect follow-up care or treatment outcomes.
- Subjects who are currently invovled in another clinical study with an investigational product.
- Subjects who are currently invovled in any injury litigation claims.
About this study
Official title: Randmised Controlled Trial Comparing Electromagnetically Navigated Versus Conventional Mechanically Aligned Total Knee Arthroplasty
The aim of this single blinded randomised control trial study was to assess the accuracy of implantation of components and the clinical outcome and complications with the iNAV electromagnetic navigation system compared with conventional techniques. Secondary outcome measures include Patient reported outcome measures (PROMS) and rates of revision surgery up to 10 years post operatively.
Read the detailed description
Participants Patients were identified by members of the research team from TKA surgical waiting lists. Patients were invited to participate if they had osteoarthritis of the knee suitable for TKA, were able to provide informed consent, and were aged 18 or over. There were no specific limits imposed on the degree of preoperative coronal or sagittal deformity.
Randomization Overall, 272 patients were screened between July 2007 and August 2010. Of the 272 screened patients, 14 were excluded for other medical reasons, whereas 58 participants decided that they did not want to participate in a research study. The remaining 200 patients were recruited and consented to the study giving a recruitment rate of 74%. Patients were randomized in a 1:1 ratio to either conventional TKA or navigated TKA using a web based computer-generated random number table. Randomization was based on the order of their recruitment and stratified by surgeons to prevent surgeon bias and ensure that similar numbers of patients in each groups were allocated to each surgeon. Randomization was successful in assigning equal preoperative patient demographics between the groups.
Ethical Approval The study was approved by the Glasgow Royal Infirmary Local Ethics Committee and the University of Strathclyde Ethics Committee (07/S0704/6) and approved by the NHS GGC R\&D department before commencement of the study.
Surgical Procedure All patients received a cemented posterior stabilized NexGen LPS Flex (Zimmer, Warsaw, Indiana, USA). Participants randomized to the conventional group received a TKA implanted using standard instrumentation, whereas those randomized to the navigated group had surgery using the iNav portable EM navigation system (Zimmer GmbH, Winterthur, Switzerland and Medtronic, Minneapolis, MN, USA). The iNav EM system is imageless and uses small reference frames attached to the femur and tibia which are readily incorporated in the primary incision. There is then a process of joint registration which maps the surface anatomy of the joint. All surgeries including joint surface registration were carried out by, or under the direct supervision of, one of two knee arthroplasty surgeons. Alignment targets were similar in both groups with a neutral HKAA and the aim to implant both femur and tibial components perpendicular to this in the coronal plane.
Ligament balancing was carried out using clinical assessment during the surgical procedure in both groups. In the navigated group, additional information was provided by the system with real-time feedback of the gap in mm between the femoral and tibial component and of the overall HKAA during varus and valgus stress.
Primary outcome measurement Post-operative CT scans were used to determine the accuracy of implantation. CT scan analysis was conducted using Mimics 12.0 software (Materialise, Leuven, Belgium). Measurements of the femoral and tibial component position in the coronal (varus/valgus), sagittal (flexion/extension) and axial (rotational) planes were made. The overall mechanical alignment was also calculated from the addition of the femoral and tibial coronal angles. The combined component rotation was calculated from the addition of the femoral and tibial rotation angles. The rotations were measured using the methods detailed in Berger et al (1998). In the coronal plane the investigators aimed to position both femoral and tibial implants at 90° to the mechanical axis. In the sagittal plane the investigators aimed to position the femoral component with a 5° slope relative to the mechanical axis, in line with the anterior cortex of the distal femur. The tibial component was aimed to be positioned at a 7° slope, as per the manufacturer's guidelines. For femoral rotation the investigators aimed to implant the femoral component in line with the surgical trans-epicondylar axis of the femur. The reference for tibial rotation was a line from the geometric center of the tibia to the center of the tuberosity. Rotational measurements were calculated from a perpendicular line drawn from the posterior surface of the implant. As the tuberosity is 18° externally rotated, the investigators considered an 18° internal rotation of the implant to be a neutral position. (No obvious deformities of the tibia or previous fractures were noted in the study cohort that could have influenced this value.) The investigators considered the desired mechanical axis alignment to be 0° with a range of ± 3°.
Patient-Reported Outcome Measures and Revisions Participants were followed up for 10 years after surgery, with clinical assessments by a blinded independent assessor; range of motion (ROM) was determined using a hand-held goniometer, and knee-specific outcome measures included the American Knee Society Score (AKSS) and Oxford Knee Scores (OKS) and the SF 36 score used as a general health measure (both physical and mental). Revision surgery was also assessed by analyzing the Scottish National Picture Archiving and Communication System. This image archiving system stores all imaging for patients undertaken in the National Health Service (NHS) in Scotland since 2008. It acts as a valuable resource for identifying patients lost to follow-up who have undergone revision surgery in other NHS hospitals in Scotland which may have not been identified.
Statistics A power calculation was performed based in data provided by a randomized controlled trial using infra red optical tracking systems. Bathis et al reported 96% of patients with mechanical leg alignment within 3° of neutral using navigation compared to just 78% with conventional instrumentation . In order to detect a difference of this magnitude with a power of 90% at alpha = 0.05, the investigators would require 82 patients per group, 164 in total. As the primary outcome measure was based on post-operative CT scan the investigators anticipated a higher than average loss to follow-up for the primary outcome measure. The investigators therefore allowed an additional 25% for loss to follow-up, giving a total of 103 patients in each group.
Statistical analysis was performed using SigmaPlot 11.0 (Systat Software Inc). To evaluate differences between the surgical groups either a two sample t test (normally distributed data) or a Mann Whitney test (non parametric data) was performed. A Chi Squared test was used to analysis the male: female ratio. A P value of less that 0.05 was considered significant.
- Being tested
- Electromagnetically navigated total knee arthroplasty, Conventional total knee arthroplasty
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Electromagnetically navigated total knee arthroplastyDevice
The navigated group had surgery using the iNav portable EM navigation system (Zimmer GmbH, Winterthur, Switzerland and Medtronic, Minneapolis, MN, USA) and the definitive implant used was NexGen LPS implant (Zimmer Inc, Warsaw, IN, USA), a fixed-bearing bicruciate-sacrificing total condylar implant using traditional instrumentation with no patellar resurfacing
Conventional total knee arthroplastyDevice
The conventional group received surgery using conventional instrumentation and jigs from the implant manufacturer (Zimmer Inc, Warsaw, IN, USA) and the definitive implant used was NexGen LPS implant (Zimmer Inc, Warsaw, IN, USA), a fixed-bearing bicruciate-sacrificing total condylar implant using traditional instrumentation with no patellar resurfacing
| Study group | Role | What they receive |
|---|---|---|
| Electromagentically navigated Total knee arthroplasty | Experimental | Patients underwent total knee arthroplasty using the iNav portable EM navigation system (Zimmer GmbH, Winterthur, Switzerland and Medtronic, Minneapolis, MN, USA). The system employs small reference frames attached to the femur and tibia which are incorporated within the primary surgical incision. A standard process of joint registration maps the surface anatomy of the joint. Alignment targets were similar in both groups with a neutral Hip-Knee-Ankle-Axis and the aim to implant both femur and tibial components perpendicular to this in the coronal plane.
All patients received a cemented posterior stabilized NexGen LPS Flex TKA (Zimmer, Warsaw, Indiana, USA). Receives: Device: Electromagnetically navigated total knee arthroplasty |
| Conventional mechanically alligned Total knee arthroplasty | Active comparator | Participants randomized to the conventional group received a TKA implanted using standard instrumentation.
All patients received a cemented posterior stabilized NexGen LPS Flex TKA (Zimmer, Warsaw, Indiana, USA).
Alignment targets were similar in both groups with a neutral Hip-Knee-Ankle-Axis and the aim to implant both femur and tibial components perpendicular to this in the coronal plane. Receives: Device: Conventional total knee arthroplasty |
What is being measured
The primary outcome is the main question the study is designed to answer.
Knee coronal plane allignment
The primary outcome measure for this study was alignment within 3 degrees of neutral mechanical alignment at three months after surgery
Measured: 3 months post operatively
Secondary outcomes (5)
Oxford knee score
Patient reported outcome measure validated for total knee arthroplasty
Measured: Up to 10 years post operatively
American Knee Society Score
Patient reported outcome measure validated for total knee arthroplasty
Measured: Up to 10 years post operatively
Short Form 36 Health Survey Questionnaire (SF-36)
Validated self reported outcome measure of health
Measured: Up to 10 years post operatively
Range of motion
Measured by research assistant post operatively using established techniques
Measured: 10 years post operatively
All cause revision surgery
Examines re-intervention rates for any cause post-operatively. We defined revision using the United Kingdom National Joint registery definition of any intervention that results in the addition, removal or exchange of any component of the primary implant
Measured: 10 years post operatively
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted13 Apr 2022
- Study start25 Jun 2007
- Primary completion7 Dec 2010
- Study completion2 Jul 2021
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (8)Papers the sponsor has linked to this study.
- Other trials for Arthroplasty, Replacement, KneeStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Double blind
- Who is masked
- Participant, Outcomes assessor
- Enrolment
- 200 participants (actual)
Sponsor and investigators
- Lead sponsor
- NHS Greater Glasgow and Clyde
- Sponsor type
- University, hospital or other
- Responsible party
- Sponsor
- Investigators
- Mark JG Blyth, Mr, Principal investigator, NHS Greater Glasgow and Clyde
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT05325060
- Sponsor's protocol ID
- RN07OR001
- Acronym
- iNAV
- Status last verified
- Apr 2022
- First submitted
- 5 Apr 2022
- Last updated
- 20 Apr 2022
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- Yes
- Individual data sharing
- No
Publications
Decking R, Markmann Y, Fuchs J, Puhl W, Scharf HP. Leg axis after computer-navigated total knee arthroplasty: a prospective randomized trial comparing computer-navigated and manual implantation. J Arthroplasty. 2005 Apr;20(3):282-8. doi: 10.1016/j.arth.2004.09.047.
PubMed 15809943Chin PL, Yang KY, Yeo SJ, Lo NN. Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique. J Arthroplasty. 2005 Aug;20(5):618-26. doi: 10.1016/j.arth.2005.04.004.
PubMed 16309998Haaker RG, Stockheim M, Kamp M, Proff G, Breitenfelder J, Ottersbach A. Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop Relat Res. 2005 Apr;(433):152-9. doi: 10.1097/01.blo.0000150564.31880.c4.
PubMed 15805951Bolognesi M, Hofmann A. Computer navigation versus standard instrumentation for TKA: a single-surgeon experience. Clin Orthop Relat Res. 2005 Nov;440:162-9. doi: 10.1097/01.blo.0000186561.70566.95.
PubMed 16239801Bathis H, Perlick L, Tingart M, Luring C, Zurakowski D, Grifka J. Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br. 2004 Jul;86(5):682-7. doi: 10.1302/0301-620x.86b5.14927.
PubMed 15274263Clark AN, Hounat A, O'Donnell S, May P, Doonan J, Rowe P, Jones BG, Blyth MJG. Electromagnetic Navigated Versus Conventional Total Knee Arthroplasty-A Five-Year Follow-Up of a Single-Blind Randomized Control Trial. J Arthroplasty. 2021 Oct;36(10):3451-3455. doi: 10.1016/j.arth.2021.06.007. Epub 2021 Jun 12.
PubMed 34226082Blyth MJ, Smith JR, Anthony IC, Strict NE, Rowe PJ, Jones BG. Electromagnetic navigation in total knee arthroplasty-a single center, randomized, single-blind study comparing the results with conventional techniques. J Arthroplasty. 2015 Feb;30(2):199-205. doi: 10.1016/j.arth.2014.09.008. Epub 2014 Sep 16.
PubMed 25263246Smith JR, Rowe PJ, Blyth M, Jones B. The effect of electromagnetic navigation in total knee arthroplasty on knee kinematics during functional activities using flexible electrogoniometry. Clin Biomech (Bristol). 2013 Jan;28(1):23-8. doi: 10.1016/j.clinbiomech.2012.09.006. Epub 2012 Oct 18.
PubMed 23083704
Study at a glance
From the registry record, last updated by the sponsor on 20 Apr 2022. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Randmised Controlled Trial Comparing Electromagnetically Navigated Versus Conventional Mechanically Aligned Total Knee Arthroplasty
- ClinicalTrials.gov ID
- NCT05325060
- Acronym / sponsor ID
- iNAV / RN07OR001
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 200 participants (actual)
- Lead sponsor
- NHS Greater Glasgow and ClydeUniversity, hospital or other
- Study start
- 25 Jun 2007 (actual)
- Primary completion
- 7 Dec 2010 (actual)
- Study completion
- 2 Jul 2021 (actual)
- First posted
- 13 Apr 2022 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The aim of this single blinded randomised control trial study was to assess the accuracy of implantation of components and the clinical outcome and complications with the iNAV electromagnetic navigation system compared with conventional techniques. Secondary outcome measures include Patient reported outcome measures (PROMS) and rates of revision surgery up to 10 years post operatively.
Detailed description
Participants Patients were identified by members of the research team from TKA surgical waiting lists. Patients were invited to participate if they had osteoarthritis of the knee suitable for TKA, were able to provide informed consent, and were aged 18 or over. There were no specific limits imposed on the degree of preoperative coronal or sagittal deformity.
Randomization Overall, 272 patients were screened between July 2007 and August 2010. Of the 272 screened patients, 14 were excluded for other medical reasons, whereas 58 participants decided that they did not want to participate in a research study. The remaining 200 patients were recruited and consented to the study giving a recruitment rate of 74%. Patients were randomized in a 1:1 ratio to either conventional TKA or navigated TKA using a web based computer-generated random number table. Randomization was based on the order of their recruitment and stratified by surgeons to prevent surgeon bias and ensure that similar numbers of patients in each groups were allocated to each surgeon. Randomization was successful in assigning equal preoperative patient demographics between the groups.
Ethical Approval The study was approved by the Glasgow Royal Infirmary Local Ethics Committee and the University of Strathclyde Ethics Committee (07/S0704/6) and approved by the NHS GGC R\&D department before commencement of the study.
Surgical Procedure All patients received a cemented posterior stabilized NexGen LPS Flex (Zimmer, Warsaw, Indiana, USA). Participants randomized to the conventional group received a TKA implanted using standard instrumentation, whereas those randomized to the navigated group had surgery using the iNav portable EM navigation system (Zimmer GmbH, Winterthur, Switzerland and Medtronic, Minneapolis, MN, USA). The iNav EM system is imageless and uses small reference frames attached to the femur and tibia which are readily incorporated in the primary incision. There is then a process of joint registration which maps the surface anatomy of the joint. All surgeries including joint surface registration were carried out by, or under the direct supervision of, one of two knee arthroplasty surgeons. Alignment targets were similar in both groups with a neutral HKAA and the aim to implant both femur and tibial components perpendicular to this in the coronal plane.
Ligament balancing was carried out using clinical assessment during the surgical procedure in both groups. In the navigated group, additional information was provided by the system with real-time feedback of the gap in mm between the femoral and tibial component and of the overall HKAA during varus and valgus stress.
Primary outcome measurement Post-operative CT scans were used to determine the accuracy of implantation. CT scan analysis was conducted using Mimics 12.0 software (Materialise, Leuven, Belgium). Measurements of the femoral and tibial component position in the coronal (varus/valgus), sagittal (flexion/extension) and axial (rotational) planes were made. The overall mechanical alignment was also calculated from the addition of the femoral and tibial coronal angles. The combined component rotation was calculated from the addition of the femoral and tibial rotation angles. The rotations were measured using the methods detailed in Berger et al (1998). In the coronal plane the investigators aimed to position both femoral and tibial implants at 90° to the mechanical axis. In the sagittal plane the investigators aimed to position the femoral component with a 5° slope relative to the mechanical axis, in line with the anterior cortex of the distal femur. The tibial component was aimed to be positioned at a 7° slope, as per the manufacturer's guidelines. For femoral rotation the investigators aimed to implant the femoral component in line with the surgical trans-epicondylar axis of the femur. The reference for tibial rotation was a line from the geometric center of the tibia to the center of the tuberosity. Rotational measurements were calculated from a perpendicular line drawn from the posterior surface of the implant. As the tuberosity is 18° externally rotated, the investigators considered an 18° internal rotation of the implant to be a neutral position. (No obvious deformities of the tibia or previous fractures were noted in the study cohort that could have influenced this value.) The investigators considered the desired mechanical axis alignment to be 0° with a range of ± 3°.
Patient-Reported Outcome Measures and Revisions Participants were followed up for 10 years after surgery, with clinical assessments by a blinded independent assessor; range of motion (ROM) was determined using a hand-held goniometer, and knee-specific outcome measures included the American Knee Society Score (AKSS) and Oxford Knee Scores (OKS) and the SF 36 score used as a general health measure (both physical and mental). Revision surgery was also assessed by analyzing the Scottish National Picture Archiving and Communication System. This image archiving system stores all imaging for patients undertaken in the National Health Service (NHS) in Scotland since 2008. It acts as a valuable resource for identifying patients lost to follow-up who have undergone revision surgery in other NHS hospitals in Scotland which may have not been identified.
Statistics A power calculation was performed based in data provided by a randomized controlled trial using infra red optical tracking systems. Bathis et al reported 96% of patients with mechanical leg alignment within 3° of neutral using navigation compared to just 78% with conventional instrumentation . In order to detect a difference of this magnitude with a power of 90% at alpha = 0.05, the investigators would require 82 patients per group, 164 in total. As the primary outcome measure was based on post-operative CT scan the investigators anticipated a higher than average loss to follow-up for the primary outcome measure. The investigators therefore allowed an additional 25% for loss to follow-up, giving a total of 103 patients in each group.
Statistical analysis was performed using SigmaPlot 11.0 (Systat Software Inc). To evaluate differences between the surgical groups either a two sample t test (normally distributed data) or a Mann Whitney test (non parametric data) was performed. A Chi Squared test was used to analysis the male: female ratio. A P value of less that 0.05 was considered significant.
Study design
- Primary purpose
- Treatment
- Allocation
- Randomised
- Intervention model
- Parallel groups
- Masking
- Double blind (participant, outcomes assessor)
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Electromagentically navigated Total knee arthroplasty | Experimental | Device: Electromagnetically navigated total knee arthroplastyPatients underwent total knee arthroplasty using the iNav portable EM navigation system (Zimmer GmbH, Winterthur, Switzerland and Medtronic, Minneapolis, MN, USA). The system employs small reference frames attached to the femur and tibia which are incorporated within the primary surgical incision. A standard process of joint registration maps the surface anatomy of the joint. Alignment targets were similar in both groups with a neutral Hip-Knee-Ankle-Axis and the aim to implant both femur and tibial components perpendicular to this in the coronal plane. All patients received a cemented posterior stabilized NexGen LPS Flex TKA (Zimmer, Warsaw, Indiana, USA). |
| Conventional mechanically alligned Total knee arthroplasty | Active comparator | Device: Conventional total knee arthroplastyParticipants randomized to the conventional group received a TKA implanted using standard instrumentation. All patients received a cemented posterior stabilized NexGen LPS Flex TKA (Zimmer, Warsaw, Indiana, USA). Alignment targets were similar in both groups with a neutral Hip-Knee-Ankle-Axis and the aim to implant both femur and tibial components perpendicular to this in the coronal plane. |
Who may qualify
- Ages
- 18 to 120 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (6 listed)
- Male or female subjects
- Subjects must be at least 18 years of age and there will be no maximum age limit. The subjects age must be considered suitable by the Investigator for a knee arthroplasty using either of the two systems available in the evaluation.
- Subjects, who are able to give voluntary, written informed consent to participate in this investigation and from whom consent has been obtained.
- Subjects, who, in the opinion of the investigator, are able to understand this investigation, co-operate with the investigation procedures and are willing to return to the hopsital for all the required post-operative follow-ups.
- Subjects who require a knee arthroplasty for primary surgical management of the idiopathic osteoarthritis.
Key exclusion criteria (16 listed)
- Subjects who, in the opinion of the investigator, have an existing condition that would compromise their participation and follow-up in the study
- Subjects who require revision total knee arthroplasty surgery
- Subjects with any tibial deformity requiring tibial component augmentation.
- Subjects whom, in the opinion of the Investigator, require a constratined prosthesis.
- Subjects with inflammatory polyarthritis.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Electromagnetically navigated total knee arthroplastyThe navigated group had surgery using the iNav portable EM navigation system (Zimmer GmbH, Winterthur, Switzerland and Medtronic, Minneapolis, MN, USA) and the definitive implant used was NexGen LPS implant (Zimmer Inc, Warsaw, IN, USA), a fixed-bearing bicruciate-sacrificing total condylar implant using traditional instrumentation with no patellar resurfacing | Device | Electromagentically navigated Total knee arthroplasty |
| Conventional total knee arthroplastyThe conventional group received surgery using conventional instrumentation and jigs from the implant manufacturer (Zimmer Inc, Warsaw, IN, USA) and the definitive implant used was NexGen LPS implant (Zimmer Inc, Warsaw, IN, USA), a fixed-bearing bicruciate-sacrificing total condylar implant using traditional instrumentation with no patellar resurfacing | Device | Conventional mechanically alligned Total knee arthroplasty |
Primary outcome
Knee coronal plane allignment
Time frame: 3 months post operatively
The primary outcome measure for this study was alignment within 3 degrees of neutral mechanical alignment at three months after surgery
5 secondary outcomes
Oxford knee score
Time frame: Up to 10 years post operatively
American Knee Society Score
Time frame: Up to 10 years post operatively
Short Form 36 Health Survey Questionnaire (SF-36)
Time frame: Up to 10 years post operatively
Range of motion
Time frame: 10 years post operatively
All cause revision surgery
Time frame: 10 years post operatively
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 20 Apr 2022.
- Background: PubMed 15809943Decking R, Markmann Y, Fuchs J, Puhl W, Scharf HP. Leg axis after computer-navigated total knee arthroplasty: a prospective randomized trial comparing computer-navigated and manual implantation. J Arthroplasty. 2005 Apr;20(3):282-8. doi: 10.1016/j.arth.2004.09.047.
- Background: PubMed 16309998Chin PL, Yang KY, Yeo SJ, Lo NN. Randomized control trial comparing radiographic total knee arthroplasty implant placement using computer navigation versus conventional technique. J Arthroplasty. 2005 Aug;20(5):618-26. doi: 10.1016/j.arth.2005.04.004.
- Background: PubMed 15805951Haaker RG, Stockheim M, Kamp M, Proff G, Breitenfelder J, Ottersbach A. Computer-assisted navigation increases precision of component placement in total knee arthroplasty. Clin Orthop Relat Res. 2005 Apr;(433):152-9. doi: 10.1097/01.blo.0000150564.31880.c4.
- Background: PubMed 16239801Bolognesi M, Hofmann A. Computer navigation versus standard instrumentation for TKA: a single-surgeon experience. Clin Orthop Relat Res. 2005 Nov;440:162-9. doi: 10.1097/01.blo.0000186561.70566.95.
- Background: PubMed 15274263Bathis H, Perlick L, Tingart M, Luring C, Zurakowski D, Grifka J. Alignment in total knee arthroplasty. A comparison of computer-assisted surgery with the conventional technique. J Bone Joint Surg Br. 2004 Jul;86(5):682-7. doi: 10.1302/0301-620x.86b5.14927.
- Results publication: PubMed 34226082Clark AN, Hounat A, O'Donnell S, May P, Doonan J, Rowe P, Jones BG, Blyth MJG. Electromagnetic Navigated Versus Conventional Total Knee Arthroplasty-A Five-Year Follow-Up of a Single-Blind Randomized Control Trial. J Arthroplasty. 2021 Oct;36(10):3451-3455. doi: 10.1016/j.arth.2021.06.007. Epub 2021 Jun 12.
- Results publication: PubMed 25263246Blyth MJ, Smith JR, Anthony IC, Strict NE, Rowe PJ, Jones BG. Electromagnetic navigation in total knee arthroplasty-a single center, randomized, single-blind study comparing the results with conventional techniques. J Arthroplasty. 2015 Feb;30(2):199-205. doi: 10.1016/j.arth.2014.09.008. Epub 2014 Sep 16.
- Results publication: PubMed 23083704Smith JR, Rowe PJ, Blyth M, Jones B. The effect of electromagnetic navigation in total knee arthroplasty on knee kinematics during functional activities using flexible electrogoniometry. Clin Biomech (Bristol). 2013 Jan;28(1):23-8. doi: 10.1016/j.clinbiomech.2012.09.006. Epub 2012 Oct 18.
- Individual participant dataSharing planned: No
Related trials for Arthroplasty, Replacement, Knee
Not yet recruiting
GENIVS Block Versus Adductor Canal Block After Total Knee Arthroplasty
Arthroplasty, Replacement, Knee, Pain, Postoperative
Not yet recruitingObservational study
oneKNEE - Prospective, Non-interventional, Multicenter PMCF-Study
Arthroplasty, Arthroplasty Replacement, Knee
RecruitingObservational study
Tau Pathology in the Brain After Hip or Knee Replacement Surgery
Postoperative Cognitive Dysfunction, Alzheimer Disease
RecruitingPhase 3
Suzetrigine in TKA
Total Knee Arthroplasty (TKA), Total Knee Arthroplasty \(TKA\)
Not yet recruiting
The Effect of White and Pink Noise in Patients Undergoing Total Hip and Knee Arthroplasty
Arthroplasty, Replacement, Knee, Hip, Postoperative Nausea and Vomiting
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Mark JG Blyth, Mr principal investigator
NHS Greater Glasgow and Clyde
Questions about this trial
What is this clinical trial studying?
A study testing Electromagnetically navigated total knee arthroplasty and Conventional total knee arthroplasty in people with Arthroplasty, Replacement, Knee and Surgery, Computer-Assisted, run by NHS Greater Glasgow and Clyde.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 6 inclusion and 16 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 20 Apr 2022. Status can change between updates, so confirm with the study contact before making plans.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Knee coronal plane allignment (time frame: 3 months post operatively). It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT05325060, which also lists 8 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 20 Apr 2022; AzTrials last refreshed its copy on 29 Oct 2026.