Noninvasive VentilationNCT05336136
Custom Non-invasive Ventilation Masks in Children
A study testing Custom mask and Current commercial mask in people with Noninvasive Ventilation and Child, Only, run by University of Alberta at 1 site in Canada.
Trial summary
One significant challenge to non-invasive ventilation (NIV) use in children is finding masks to fit a wide range of growing shapes and sizes. While the technology has improved with development of masks specifically for children, the range of options remains limited. Read more about this study
- Who is it for?
- Ages 8 to 12 years
- Conditions the study is for
- Noninvasive Ventilation, Child, Only, Adherence, Patient
- What is being tested?
- Custom mask and Current commercial mask
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 16 participants
- Where
- 1 siteCanada
- Study dates
- 15 Dec 2023to 27 Jul 2026
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 8 to 12 years
- All sexes
- No healthy volunteers
- Child
Who may be able to join
- Children between 8-12 years of age
- Followed clinically by the Non-invasive ventilation clinic at the Stollery Children's Hospital
- Established on non-invasive ventilation as part of their treatment plan.
Who cannot join
- Children with developmental or physical disabilities that would prevent their successful completion of the study protocol (e.g., non-verbal, unable to follow 3-step commands, unalbe to lie still for 20 min).
- Children whose parent/guardian are unable to provide consent because of an inability to read the study documents in english.
Trial locations and contacts
1 site in 1 country.
About this study
One significant challenge to non-invasive ventilation (NIV) use in children is finding masks to fit a wide range of growing shapes and sizes. While the technology has improved with development of masks specifically for children, the range of options remains limited. Given the smaller size relative to adults, craniofacial abnormalities and craniofacial differences are more likely to compromise mask fit for children. A poor mask fit is uncomfortable, alters delivery of airway pressure, and, in some children, leads to failure of NIV and the need for surgical insertion of an airway in the neck to deliver positive airway pressure through a tracheostomy. This makes expanding the technology to deliver NIV vital and custom NIV masks an exciting solution.In this study, this study will enroll children who are established on long-term NIV with at least some use within 3 months of starting this therapy but who have non-optimal adherence. After consenting to participate and completing demographic and health questionnaire, participants will undergo a facial scan using stereophotogrammetry. This scan will be imported into a computer-aided design software to create a NIV mask customized to the individual face. The steps of mask testing will include: i) Bench testing to compare the leak and comfort parameters of the current commercial mask used by the participant to the custom mask: ii) Efficacy of treatment as measured by polysomonography iii) NIV compliance from machine downloads; iv) Questionnaires to assess the subjective comfort, fit, and adverse events Finally, participants and their parents/guardian will be asked which mask they prefer and why.
Read the detailed description
- Background 1.1 Investigational Device Custom non-invasive ventilation (NIV) masks will be fabricated based on a facial scan of the participant using sterophotogrammetry (3D photography). The scanner captures and digitizes facial features in a 180o ear-to-ear view in a few seconds. The points in the data set represent the surface of the face. This data set is then converted into a surface representation that can be manipulated using computer-aided design software (MeshMixer, Autodesk, San Rafael, CA). The facial scan data will be imported into computer-aided design (CAD) software (Fusion 360, Autodesk, San Rafael, CA) to create an NIV mask that is customized to the individual face. Once the design is created, a mold will be printed out of polylactic acid filament using a fused filament fabrication 3D printer (Ultimaker II, Ultimaker North America, Cambridge, MA). The printed mold will then be injected with medical grade silicone (Dragonskin, Smooth-On, Macungie, PA), and cured overnight. The coupler, used to attach the mask to the tubing connected to the ventilator, will be directly printed using stereolithography (SL Moai, Peopoly, Los Angeles, CA). 1.2 Previous Studies and Predicate Devices A few reports indicate that quantitative approaches towards NIV mask selection may improve comfort and adherence to treatment. In 2018 Ma et al. reviewed selection and design considerations for continuous positive airway pressure (CPAP) masks and stated "There is potential for optimizing the CPAP mask fit by adapting the interface to the patients' individual characteristics. This holds particularly true for users with abnormal features or simply outside conventional industry sizing standards. There is to date no integrated system that integrates those elements into a standard solution, but several studies have shown its effectiveness for specific cohorts."1 In 2019, Goh et al. reported a quantitative analysis of facial photographs of obstructive sleep apnea (OSA) patients.2 This report suggests that quantifying individual craniofacial features may help guide mask choice for NIV treatment for OSA, although the authors cautioned that the oronasal masks were not as effective as the nasal masks in terms of leakage and in reducing the number of apnea events. Despite the caveats, the report supports that further study of aa more rigorous approach to mask fitting is warranted. In an accompanying commentary, Cistulli and Sullivan state: "Surprisingly, the evidence base supporting clinical decisions about appropriate mask selection is relatively weak and is based largely on art rather than science."3 At least two companies offer custom NIV masks, including Inspirate (Singapore) and ApneaSeal, (Australia). To our knowledge, however, efficacy and compliance of custom versus commercial masks has not been tested rigorously. In addition, the published literature on customized masks for NIV therapy is small. For creating the masks de novo, one report details the fabrication of customized masks using maxillofacial prosthodontic laboratory techniques,4 while another reports a procedure including impression casting, 3D printing and silicone casting.5 Another approach describes modifying standard masks to create 3D-printed interfaces fitted to individual faces.6 1.3 Trial Conduct This study will be conducted in compliance with the protocol approved by the University of Alberta Health Research Ethics Board (HREB), and according to Good Clinical Practice standards. 1.4 Population Children already established on NIV (use for at least 3 month) between the ages of 6-12 years who continue to show sub-optimal adherence are able to be the participants in this clinical trial. Children with craniofacial disease or differences make up a large proportion of children using NIV. Craniofacial dimensions change with growth such that children using NIV may need to change to a different mask to provide the best possible fit. Children with developmental or physical disabilities that would prevent their successful completion of the study protocol (e.g., non-verbal, unable to follow 3-step commands, unable to lie still for 20 min) will be excluded from recruitment.
- Trial Objectives To compare the efficacy of custom NIV masks to commercial masks as measured by efficacy of treatment delivery, compliance, fit test, and ratings of comfort.
- Trial Design 3.1 Study Design/Type This is a non-randomized clinical trial using a crossover design comparing a custom NIV mask to the participants current commercial NIV mask. 3.2 Procedures There will be three parts to this trial to compare the custom mask to the participant's current commercial mask:
- Fit testing will assess both the unintentional leak and comfort of the custom mask compared to the participant's current commercial mask. This will be completed with the participant sitting in a seated position. For each mask, an in-line flow sensor will be used to assess unintentional leak (i.e., air leak around the mask) at two levels of mask tightness (typical used at home, loose) and two pressures (current mean airway pressure, 4 cmH20 higher). Participants will be asked to rate comfort for each trial using a pictorial visual analogue scale. The total testing time including set-up will be approximately 45 min. ii) Titration polysomnography will assess the treatment efficacy. Participants will undergo a standard clinical polysomnography in the Pediatric Sleep Laboratory using their current commercial mask and then the custom mask prior with a 2-week measurement of compliance after each polysomnography study. The titration studies will be scored according to the Pediatric Sleep Laboratory protocol and the data extracted for analysis. iii) NIV compliance \& end of trial questionnaire will assess compliance from NIV machine downloads as well as mask comfort and fit prior to and at the end of each 2-weeks compliance monitoring period, and preference assessed at the end of the study. After each titration study (custom, commercial mask), participants will use the same mask for 2-weeks with NIV machine downloads obtained specific to this time period for each mask. At the end of each 2-week period, participants and their parent/guardian will be asked to complete a questionnaire to assess participantive comfort and fit using a pictorial visual analogue scale as well as to provide narrative data on their experience. Participants and their parent/guardian will also be asked to describe any adverse events. There will be a minimum 2-week wash out period between mask trials where the participants will wear their current commercial ask without monitoring. After each participant has completed both 2-week trials, the participant and their parent/guardian will be asked which mask they prefer and why. The decision as to whether the custom mask is appropriate for on-going use outside the trial will be made by the participant, their parent/guardian, and the NIV clinical team (includes physicians, an NIV nurse practitioner, and an NIV respiratory therapist).
- Statistical Plan 4.1 Statistical Methods Descriptive statistics will be used to summarize demographic and health information of the participants. Pair-wise t-tests will be used to compare continuous data including unintended air leak, polysomnography variables, and compliance measurements between custom and commercial masks with corrections for multiple comparisons as appropriate. Categorical data, including comfort and mask preference, will be analyzed using Chi-square or Kruskal-Wallis tests.
4.2 Participant Population(s) for Analysis Power calculations show that based on the recruitment of 15 participants, we will have the ability to detect a 1 hour increase in NIV compliance (increase in average use per day from 360 min to 420 min, SD 60 min) with power = 0.86, α = 0.05. Participants will be identified through the NIV clinic and approached for participation as they are identified. As the sample is not random and will focus on those with low compliance, the study results will be relevant to those children most likely to benefit from a custom mask.
- Conditions
- Noninvasive Ventilation, Child, Only, Adherence, Patient
- Being tested
- Custom mask, Current commercial mask
- Medical subject headings
- Patient Compliance
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Custom maskDevice
Custom mask based on 3D facial photograph for administration of non-invasive ventilation
Current commercial maskDevice
Current commercial mask used for administration of non-invasive ventilation
| Study group | Role | What they receive |
|---|---|---|
| Custom mask | Experimental | Custom mask based on 3D facial photograph for administration of non-invasive ventilation Receives: Device: Custom mask |
| Current commercial mask | Active comparator | Current commercial mask used by the participant for administration of non-invasive ventilation Receives: Device: Current commercial mask |
What is being measured
The primary outcome is the main question the study is designed to answer.
Change in apnea hypopnea index
Polysomnography parameter - apnea hypopnea index
Measured: Baseline (commercial mask study), repeated measure at 1 month (custom mask)
Change in obstructive apnea hypopnea index
Polysomnography parameter - obstructive apnea hypopnea index
Measured: Baseline (commercial mask study), repeated measure at 1 month (custom mask)
Change in oxygen desaturation index
Polysomnography parameter - oxygen desaturation index
Measured: Baseline (commercial mask study), repeated measure at 1 month (custom mask)
Change in percent time with oxygen saturation less than 90%
Polysomnography parameter - percent time with oxygen saturation less than 90%
Measured: Baseline (commercial mask study), repeated measure at 1 month (custom mask)
Change in percentage of nights used
Machine download
Measured: Two weeks of commercial versus custom mask use
Change in average time used/night
Machine download
Measured: Two weeks of commercial versus custom mask use
Secondary outcomes (5)
Change in mask air leak (bench testing)
Unintentional mask leak
Measured: Baseline (commercial mask study), repeated measure at 1 month (custom mask)
Change in mask comfort - participant (visual likert scale, 1-9)
Subjective rating of mask comfort from participant
Measured: End of two week of mask use of commercial versus custom mask
Change in mask comfort - parent (visual likert scale1-9)
Subjective rating of mask comfort from parent
Measured: End of two week of mask use of commercial versus custom mask
Mask preference - participant (question)
Participant selection of mask preference with reasons
Measured: End of trial - 1 month
Mask preference - parent (question)
Parent selection of mask preference with reasons
Measured: End of trial - 1 month
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted20 Apr 2022
- Study start15 Dec 2023
- Primary completion27 Jul 2026
- Study completion27 Jul 2026
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Noninvasive VentilationStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Treatment
- Allocation
- Non-randomised
- Intervention model
- Crossover
- Model description
- Within subject crossover
- Masking
- None (open label)
- Enrolment
- 16 participants (actual)
Sponsor and investigators
- Lead sponsor
- University of Alberta
- Sponsor type
- University, hospital or other
- Collaborators
- Stollery Children's Hospital
- Responsible party
- Sponsor
- Investigators
- Joanna E MacLean, MD, PhD, Principal investigator, University of Alberta
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT05336136
- Sponsor's protocol ID
- Pro00047768
- Status last verified
- Sep 2026
- First submitted
- 7 Jun 2021
- Last updated
- 9 Sep 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Study at a glance
From the registry record, last updated by the sponsor on 9 Sep 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Custom Non-invasive Ventilation Masks in Children
- ClinicalTrials.gov ID
- NCT05336136
- Acronym / sponsor ID
- Pro00047768
- Conditions
- Noninvasive Ventilation, Child, Only, Adherence, Patient
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 16 participants (actual)
- Lead sponsor
- University of AlbertaUniversity, hospital or other
- Collaborators
- Stollery Children's Hospital
- Study start
- 15 Dec 2023 (actual)
- Primary completion
- 27 Jul 2026 (actual)
- Study completion
- 27 Jul 2026 (actual)
- First posted
- 20 Apr 2022 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
One significant challenge to non-invasive ventilation (NIV) use in children is finding masks to fit a wide range of growing shapes and sizes. While the technology has improved with development of masks specifically for children, the range of options remains limited. Given the smaller size relative to adults, craniofacial abnormalities and craniofacial differences are more likely to compromise mask fit for children. A poor mask fit is uncomfortable, alters delivery of airway pressure, and, in some children, leads to failure of NIV and the need for surgical insertion of an airway in the neck to deliver positive airway pressure through a tracheostomy. This makes expanding the technology to deliver NIV vital and custom NIV masks an exciting solution.In this study, this study will enroll children who are established on long-term NIV with at least some use within 3 months of starting this therapy but who have non-optimal adherence. After consenting to participate and completing demographic and health questionnaire, participants will undergo a facial scan using stereophotogrammetry. This scan will be imported into a computer-aided design software to create a NIV mask customized to the individual face. The steps of mask testing will include: i) Bench testing to compare the leak and comfort parameters of the current commercial mask used by the participant to the custom mask: ii) Efficacy of treatment as measured by polysomonography iii) NIV compliance from machine downloads; iv) Questionnaires to assess the subjective comfort, fit, and adverse events Finally, participants and their parents/guardian will be asked which mask they prefer and why.
Detailed description
- Background 1.1 Investigational Device Custom non-invasive ventilation (NIV) masks will be fabricated based on a facial scan of the participant using sterophotogrammetry (3D photography). The scanner captures and digitizes facial features in a 180o ear-to-ear view in a few seconds. The points in the data set represent the surface of the face. This data set is then converted into a surface representation that can be manipulated using computer-aided design software (MeshMixer, Autodesk, San Rafael, CA). The facial scan data will be imported into computer-aided design (CAD) software (Fusion 360, Autodesk, San Rafael, CA) to create an NIV mask that is customized to the individual face. Once the design is created, a mold will be printed out of polylactic acid filament using a fused filament fabrication 3D printer (Ultimaker II, Ultimaker North America, Cambridge, MA). The printed mold will then be injected with medical grade silicone (Dragonskin, Smooth-On, Macungie, PA), and cured overnight. The coupler, used to attach the mask to the tubing connected to the ventilator, will be directly printed using stereolithography (SL Moai, Peopoly, Los Angeles, CA). 1.2 Previous Studies and Predicate Devices A few reports indicate that quantitative approaches towards NIV mask selection may improve comfort and adherence to treatment. In 2018 Ma et al. reviewed selection and design considerations for continuous positive airway pressure (CPAP) masks and stated "There is potential for optimizing the CPAP mask fit by adapting the interface to the patients' individual characteristics. This holds particularly true for users with abnormal features or simply outside conventional industry sizing standards. There is to date no integrated system that integrates those elements into a standard solution, but several studies have shown its effectiveness for specific cohorts."1 In 2019, Goh et al. reported a quantitative analysis of facial photographs of obstructive sleep apnea (OSA) patients.2 This report suggests that quantifying individual craniofacial features may help guide mask choice for NIV treatment for OSA, although the authors cautioned that the oronasal masks were not as effective as the nasal masks in terms of leakage and in reducing the number of apnea events. Despite the caveats, the report supports that further study of aa more rigorous approach to mask fitting is warranted. In an accompanying commentary, Cistulli and Sullivan state: "Surprisingly, the evidence base supporting clinical decisions about appropriate mask selection is relatively weak and is based largely on art rather than science."3 At least two companies offer custom NIV masks, including Inspirate (Singapore) and ApneaSeal, (Australia). To our knowledge, however, efficacy and compliance of custom versus commercial masks has not been tested rigorously. In addition, the published literature on customized masks for NIV therapy is small. For creating the masks de novo, one report details the fabrication of customized masks using maxillofacial prosthodontic laboratory techniques,4 while another reports a procedure including impression casting, 3D printing and silicone casting.5 Another approach describes modifying standard masks to create 3D-printed interfaces fitted to individual faces.6 1.3 Trial Conduct This study will be conducted in compliance with the protocol approved by the University of Alberta Health Research Ethics Board (HREB), and according to Good Clinical Practice standards. 1.4 Population Children already established on NIV (use for at least 3 month) between the ages of 6-12 years who continue to show sub-optimal adherence are able to be the participants in this clinical trial. Children with craniofacial disease or differences make up a large proportion of children using NIV. Craniofacial dimensions change with growth such that children using NIV may need to change to a different mask to provide the best possible fit. Children with developmental or physical disabilities that would prevent their successful completion of the study protocol (e.g., non-verbal, unable to follow 3-step commands, unable to lie still for 20 min) will be excluded from recruitment.
- Trial Objectives To compare the efficacy of custom NIV masks to commercial masks as measured by efficacy of treatment delivery, compliance, fit test, and ratings of comfort.
- Trial Design 3.1 Study Design/Type This is a non-randomized clinical trial using a crossover design comparing a custom NIV mask to the participants current commercial NIV mask. 3.2 Procedures There will be three parts to this trial to compare the custom mask to the participant's current commercial mask:
- Fit testing will assess both the unintentional leak and comfort of the custom mask compared to the participant's current commercial mask. This will be completed with the participant sitting in a seated position. For each mask, an in-line flow sensor will be used to assess unintentional leak (i.e., air leak around the mask) at two levels of mask tightness (typical used at home, loose) and two pressures (current mean airway pressure, 4 cmH20 higher). Participants will be asked to rate comfort for each trial using a pictorial visual analogue scale. The total testing time including set-up will be approximately 45 min. ii) Titration polysomnography will assess the treatment efficacy. Participants will undergo a standard clinical polysomnography in the Pediatric Sleep Laboratory using their current commercial mask and then the custom mask prior with a 2-week measurement of compliance after each polysomnography study. The titration studies will be scored according to the Pediatric Sleep Laboratory protocol and the data extracted for analysis. iii) NIV compliance \& end of trial questionnaire will assess compliance from NIV machine downloads as well as mask comfort and fit prior to and at the end of each 2-weeks compliance monitoring period, and preference assessed at the end of the study. After each titration study (custom, commercial mask), participants will use the same mask for 2-weeks with NIV machine downloads obtained specific to this time period for each mask. At the end of each 2-week period, participants and their parent/guardian will be asked to complete a questionnaire to assess participantive comfort and fit using a pictorial visual analogue scale as well as to provide narrative data on their experience. Participants and their parent/guardian will also be asked to describe any adverse events. There will be a minimum 2-week wash out period between mask trials where the participants will wear their current commercial ask without monitoring. After each participant has completed both 2-week trials, the participant and their parent/guardian will be asked which mask they prefer and why. The decision as to whether the custom mask is appropriate for on-going use outside the trial will be made by the participant, their parent/guardian, and the NIV clinical team (includes physicians, an NIV nurse practitioner, and an NIV respiratory therapist).
- Statistical Plan 4.1 Statistical Methods Descriptive statistics will be used to summarize demographic and health information of the participants. Pair-wise t-tests will be used to compare continuous data including unintended air leak, polysomnography variables, and compliance measurements between custom and commercial masks with corrections for multiple comparisons as appropriate. Categorical data, including comfort and mask preference, will be analyzed using Chi-square or Kruskal-Wallis tests.
4.2 Participant Population(s) for Analysis Power calculations show that based on the recruitment of 15 participants, we will have the ability to detect a 1 hour increase in NIV compliance (increase in average use per day from 360 min to 420 min, SD 60 min) with power = 0.86, α = 0.05. Participants will be identified through the NIV clinic and approached for participation as they are identified. As the sample is not random and will focus on those with low compliance, the study results will be relevant to those children most likely to benefit from a custom mask.
Study design
- Primary purpose
- Treatment
- Allocation
- Non-randomised
- Intervention model
- Crossover
- Masking
- None (open label)
- Number of arms
- 2
- Model description
- Within subject crossover
| Arm | Type | Receives |
|---|---|---|
| Custom mask | Experimental | Device: Custom maskCustom mask based on 3D facial photograph for administration of non-invasive ventilation |
| Current commercial mask | Active comparator | Device: Current commercial maskCurrent commercial mask used by the participant for administration of non-invasive ventilation |
Who may qualify
- Ages
- 8 to 12 years
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Child
Key inclusion criteria (3 listed)
- Children between 8-12 years of age
- Followed clinically by the Non-invasive ventilation clinic at the Stollery Children's Hospital
- Established on non-invasive ventilation as part of their treatment plan.
Key exclusion criteria (2 listed)
- Children with developmental or physical disabilities that would prevent their successful completion of the study protocol (e.g., non-verbal, unable to follow 3-step commands, unalbe to lie still for 20 min).
- Children whose parent/guardian are unable to provide consent because of an inability to read the study documents in english.
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Custom maskCustom mask based on 3D facial photograph for administration of non-invasive ventilation | Device | Custom mask |
| Current commercial maskCurrent commercial mask used for administration of non-invasive ventilation | Device | Current commercial mask |
Primary outcome
Change in apnea hypopnea index
Time frame: Baseline (commercial mask study), repeated measure at 1 month (custom mask)
Polysomnography parameter - apnea hypopnea index
Change in obstructive apnea hypopnea index
Time frame: Baseline (commercial mask study), repeated measure at 1 month (custom mask)
Polysomnography parameter - obstructive apnea hypopnea index
Change in oxygen desaturation index
Time frame: Baseline (commercial mask study), repeated measure at 1 month (custom mask)
Polysomnography parameter - oxygen desaturation index
Change in percent time with oxygen saturation less than 90%
Time frame: Baseline (commercial mask study), repeated measure at 1 month (custom mask)
Polysomnography parameter - percent time with oxygen saturation less than 90%
Change in percentage of nights used
Time frame: Two weeks of commercial versus custom mask use
Machine download
Change in average time used/night
Time frame: Two weeks of commercial versus custom mask use
Machine download
5 secondary outcomes
Change in mask air leak (bench testing)
Time frame: Baseline (commercial mask study), repeated measure at 1 month (custom mask)
Change in mask comfort - participant (visual likert scale, 1-9)
Time frame: End of two week of mask use of commercial versus custom mask
Change in mask comfort - parent (visual likert scale1-9)
Time frame: End of two week of mask use of commercial versus custom mask
Mask preference - participant (question)
Time frame: End of trial - 1 month
Mask preference - parent (question)
Time frame: End of trial - 1 month
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 9 Sep 2026.
- Individual participant dataSharing planned: No
Related trials for Noninvasive Ventilation
Recruiting
Bedside Spirometry for Acute Lung Injury
Respiratory Insufficiency
RecruitingObservational study
RESET-COPD Cohort: Real-Time Monitoring and Early Warning in COPD Patients Receiving Home NPPV
Pulmonary Disease, Chronic Obstructive (COPD), Chronic Respiratory Failure With Hypercapnia
Not yet recruiting
Feasibility of Noninvasive Trigeminal Nerve Stimulation During Exercise
COPD
Not yet recruiting
Effect of Systematic and Sequential Leg Elevation on Cardiac Output in Healthy Volunteers
Healthy Adult, Cardiac Output
Recruiting
HFNC Versus NIV in Hypercapneic COPD Patients
COPD (Chronic Obstructive Pulmonary Disease)
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Joanna E MacLean, MD, PhD principal investigator
University of Alberta
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Custom mask and Current commercial mask in people with Noninvasive Ventilation and Child, Only, run by University of Alberta at 1 site in Canada.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 9 Sep 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Canada. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Change in apnea hypopnea index (time frame: Baseline (commercial mask study), repeated measure at 1 month (custom mask)). The study lists 6 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 9 Sep 2026.