Cardiac Conduction SystemHIPPOSNCT05491655

High Intensity His Bundle Pacing in Heart Failure Patients With Narrow QRS Outcome Study

A study testing High Intensity His Bundle pacing in people with Cardiac Conduction System and His Bundle Pacing, run by Miulli General Hospital at 1 site in Italy.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Cardiac Resynchronization Therapy (CRT) decreases heart failure hospitalizations and mortality and increases left ventricular Ejection Fraction (EF) in patients with dilated cardiomyopathy, left bundle branch block and QRS duration >130msec. His bundle pacing has a similar effect in this category of patients. Read more about this study

Who is it for?
Ages 18 to 90 years
What is being tested?
High Intensity His Bundle pacing
Type of treatment
Medical device
Could I receive a placebo?
Yes, some participants may receive a placebo
How many people
40 participants
Where
1 siteItaly
Study dates
29 Mar 2023to 1 Aug 2026
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 90 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Aged 18 or above
  • Ventricular Ejection Fraction (EF) < 50%; BNP needs to be ≥250ng/L or N Terminal-pro BNP≥600ng/L for patients with EF 36-50% and they should have an ICD indication
  • New York Heart Association (NYHA) class I-IV
  • Narrow QRS duration (≤110ms) on 12 lead ECG

Who cannot join

  • Other serious medical condition with life expectancy of less than 1 year
  • Lack of capacity to consent
  • Pregnancy
  • Previous aortic valve surgery

Trial locations and contacts

1 site in 1 country.

Italy1 site
  • Miulli General Hospital

    Acquaviva delle Fonti, Bari, 70021

Other trials in Italy

About this study

Cardiac Resynchronization Therapy (CRT) decreases heart failure hospitalizations and mortality and increases left ventricular Ejection Fraction (EF) in patients with dilated cardiomyopathy, left bundle branch block and QRS duration >130msec. His bundle pacing has a similar effect in this category of patients. However, CRT is not beneficial in heart failure (HF) patients with narrow QRS. His-bundle pacing delivers physiological ventricular activation and has been shown to improve acute hemodynamic function in patients with heart failure, a prolonged PR interval, and either a narrow QRS or RBBB through AV delay optimization. We observed an acute hemodynamic effect during application of higher pacing output (3.5 Volts/1 msec) in HF patients with dilated or ischemic cardiomyopathy and narrow QRS independently of the paced QRS duration or AV delay shortening.

This is a single-center, prospective randomized single-blinded study, recruiting a sub-population of patients with heart failure (dilated or ischemic cardiomyopathy, EF<50%, narrow QRS (<110 msec), in optimal medical treatment who have an indication for ICD.

Read the detailed description

Cardiac Resynchronization Therapy (CRT) decreases heart failure hospitalizations and mortality and increases left ventricular Ejection Fraction (EF) in patients with dilated cardiomyopathy, left bundle branch block and QRS duration >130msec. His bundle pacing has a similar effect in this category of patients. However, CRT is not beneficial in heart failure (HF) patients with narrow QRS. His-bundle pacing delivers physiological ventricular activation and has been shown to improve acute hemodynamic function in patients with heart failure, a prolonged PR interval, and either a narrow QRS or Right Bundle Branch Block (RBBB) through atrioventricular (AV) delay optimization. We observed an acute hemodynamic effect during application of higher pacing output (3.5 Volts/1 msec) in HF patients with dilated or ischemic cardiomyopathy and narrow QRS independently of the paced QRS duration or AV delay shortening.

This is a single-center, prospective randomized single-blinded study, recruiting a sub-population of patients with heart failure (dilated or ischemic cardiomyopathy, EF<50%, narrow QRS (<110 msec), in optimal medical treatment who have an indication for ICD.

All patients will be implanted with a CRT (Cardiac Resynchronization Therapy) defibrillator with one of the leads positioned on the His bundle to obtain direct His-bundle capture. (There will be a 1-month run-in period where the output voltage will be 3.5 Volts/1 or 2V/1msec according to the group so as to obtain stable threshold).

A single-blinded design will then be employed to investigate the effect of His bundle pacing. Patients will be allocated in random order to six-month treatment periods in each of the following two states (1) 3.5 Volts/1 msec pacing output direct His-bundle pacing, AV delay will be programmed in order to obtain a PR interval of 120-140msec; (2)back up only pacing (pacemaker programmed to VVI 30 bpm or AAI(R-DDD(R) 60bpm). Endpoint measurements will be taken at baseline, 1 month run-in period of 3.5 Volts/1 msec or 2V/1msec pacing output and 6 months post randomization. Treating Physicians will be aware of assignment in order to facilitate routine device follow-up. Echocardiographic and electrocardiographic evaluation will be performed in a blinded manner. Treatment allocation will be blinded to the endpoint assessor and the patient.

Patients entering the study will attend for implantation of a CRT pacemaker device with one lead positioned on the His bundle. This will be performed in Miulli General Hospital (and other participating centres) no later than 2 months after the patient's screening visit.

Before the intervention patients will be randomized to either receive active pacing treatment with 3.5 V/1 msec or back up only pacing (pacemaker programmed to VVI 30 bpm or AAI(R)-DDD(R) 60) for 6 months. All patients will be implanted with an Implantable cardioverter defibrillator (ICD) and an ICD lead in the right ventricle (RV) (either RV apex or RV septum). In all patients a pacing lead will be positioned in the right atrium (typically the right atrial appendage). All patients will have a pacemaker lead positioned on the His bundle to obtain direct His-bundle capture.

After implantation of the device there will be a 1-month run-in period that the device will be programmed to deliver His bundle pacing therapy during this period at 3.5 Volts/1msec or 2V/1msec according to the assignment group.

One month after patients are implanted with their device, patients will either receive active pacing treatment with 3.5 V/1 msec or back up only pacing (pacemaker programmed to VVI 30 bpm or AAI(R)-DDD(R) 60bpm) for 6 months. Treatment allocation will be obtained using an Interactive Web Response System (IWRS) programmed with a randomization schedule provided by the trial statistician. Appropriate blocking will be used.

Being tested
High Intensity His Bundle pacing
Keywords
His bundle pacing, conduction system pacing, Heart failure, Cardiomyopathy, narrow QRS, Ejection Fraction
Medical subject headings
Arrhythmias, Cardiac, Heart Failure, Cardiomyopathies

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • High Intensity His Bundle pacingDevice

    All patients will be implanted with an Implantable cardioverter defibrillator (ICD) and an ICD lead in the right ventricle (either RV apex or RV septum). In all patients a pacing lead will be positioned in the right atrium (typically the right atrial appendage). All patients will have a pacemaker lead positioned on the His bundle to obtain direct His-bundle capture.

Study groups in NCT05491655
Study groupRoleWhat they receive
High intensity His bundle pacingExperimentalAfter implantation of the device there will be a 1-month run-in period that the device will be programmed to deliver His bundle pacing therapy during this period at 3.5V/1msec. After one month these patients will continue to receive active pacing treatment with 3.5V/1msec.
Receives: Device: High Intensity His Bundle pacing
Back up only ventricular pacingSham comparatorAfter implantation of the device there will be a 1-month run-in period that the device will be programmed to deliver His bundle pacing therapy during this period at 2V/1msec. After one month these patients will receive back up only pacing (pacemaker programmed to VVI 30 bpm or AAI(R)-DDD(R) 50bpm) for 6 months.
Receives: Device: High Intensity His Bundle pacing

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Change in left ventricular ejection fraction

    change in left ventricular ejection fraction measured by 2D echo at 6 months compared to baseline

    Measured: Baseline pre-intervention, randomisation and 6 months post randomisation

Secondary outcomes (3)
  1. Changes in B-type Natriuretic Peptide (BNP)

    Measured from blood samples

    Measured: Baseline pre-intervention, randomisation and 6 months post randomisation

  2. Changes in Quality of Life (QOL) Scores

    Change in QOL measured by the Kansas City Cardiomyopathy Questionnaire at 1 and 6 months compared to baseline. Scores are scaled 0-100, where 0 denotes the lowest reportable health status and 100 the highest

    Measured: Baseline pre-intervention,1 and 6 months post randomisation

  3. Changes in arrhythmia burden

    Measured during Pacemaker control

    Measured: 1 month and 6 months post randomization.

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted8 Aug 2022
  2. Study start29 Mar 2023
  3. Primary completion1 Aug 2026
  4. Study completion1 Aug 2026

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Randomised
Intervention model
Parallel groups
Masking
Triple blind
Who is masked
Participant, Care provider, Outcomes assessor
Enrolment
40 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05491655
Sponsor's protocol ID
MGH_003
Acronym
HIPPOS
Status last verified
Oct 2026
First submitted
4 Aug 2022
Last updated
16 Oct 2026
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • Grigorios E Katsouras, Stavros Stavrakis, Beneficial effects of high output His bundle pacing in patients with heart failure and narrow QRS, Heart Rhythm, Vol 20, Issue 5, Supplement, S479-S480

  • Bristow MR, Saxon LA, Boehmer J, Krueger S, Kass DA, De Marco T, Carson P, DiCarlo L, DeMets D, White BG, DeVries DW, Feldman AM; Comparison of Medical Therapy, Pacing, and Defibrillation in Heart Failure (COMPANION) Investigators. Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. N Engl J Med. 2004 May 20;350(21):2140-50. doi: 10.1056/NEJMoa032423.

    PubMed 15152059
  • Upadhyay GA, Vijayaraman P, Nayak HM, Verma N, Dandamudi G, Sharma PS, Saleem M, Mandrola J, Genovese D, Tung R; His-SYNC Investigators. His Corrective Pacing or Biventricular Pacing for Cardiac Resynchronization in Heart Failure. J Am Coll Cardiol. 2019 Jul 9;74(1):157-159. doi: 10.1016/j.jacc.2019.04.026. Epub 2019 May 9. No abstract available.

    PubMed 31078637
  • Cleland JG, Abraham WT, Linde C, Gold MR, Young JB, Claude Daubert J, Sherfesee L, Wells GA, Tang AS. An individual patient meta-analysis of five randomized trials assessing the effects of cardiac resynchronization therapy on morbidity and mortality in patients with symptomatic heart failure. Eur Heart J. 2013 Dec;34(46):3547-56. doi: 10.1093/eurheartj/eht290. Epub 2013 Jul 29.

    PubMed 23900696
  • Whinnett ZI, Shun-Shin MJ, Tanner M, Foley P, Chandrasekaran B, Moore P, Adhya S, Qureshi N, Muthumala A, Lane R, Rinaldi A, Agarwal S, Leyva F, Behar J, Bassi S, Ng A, Scott P, Prasad R, Swinburn J, Tomson J, Sethi A, Shah J, Lim PB, Kyriacou A, Thomas D, Chuen J, Kamdar R, Kanagaratnam P, Mariveles M, Burden L, March K, Howard JP, Arnold A, Vijayaraman P, Stegemann B, Johnson N, Falaschetti E, Francis DP, Cleland JGF, Keene D. Effects of haemodynamically atrio-ventricular optimized His bundle pacing on heart failure symptoms and exercise capacity: the His Optimized Pacing Evaluated for Heart Failure (HOPE-HF) randomized, double-blind, cross-over trial. Eur J Heart Fail. 2023 Feb;25(2):274-283. doi: 10.1002/ejhf.2736.

    PubMed 36404397

Questions about this trial

What is this clinical trial studying?

A study testing High Intensity His Bundle pacing in people with Cardiac Conduction System and His Bundle Pacing, run by Miulli General Hospital at 1 site in Italy.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 4 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 16 Oct 2026. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Italy. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. Some participants in this study may receive a placebo. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Change in left ventricular ejection fraction (time frame: Baseline pre-intervention, randomisation and 6 months post randomisation). It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT05491655, which also lists 5 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 16 Oct 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in