Cardiac OutputNCT05508711
Comparability of Transesophageal Echocardiography and FloTrac/Vigileo System Three Different Positions
An observational study of Cardiac Output, run by Université Libre de Bruxelles at 1 site in Belgium.
Trial summary
The use of cardiac output monitoring to guide intraoperative fluid management and inotropic drugs as part of a hemodynamic therapy algorithm reduce the complication rate in major abdominal surgery. Read more about this study
- Who is it for?
- Ages 18 years and olderHealthy volunteers can take part
- Conditions the study is for
- Cardiac Output
- What is being tested?
- FloTrac/Vigileo system (© Edwards Lifesciences) (Edwards Lifesciences, Irvine, CA) device
- Type of treatment
- Medical device
- How many people
- 40 participants
- Where
- 1 siteBelgium
- Study dates
- 1 Oct 2021to 30 Jun 2022
- Phase
- Observational
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Study population: Patients without heart disease or hemodynamic instability scheduled for elective pancreatic, bladder or liver surgery requiring invasive monitoring and Trendelenburg position during the procedure.
Who may be able to join
- patients scheduled for elective pancreatic, bladder or liver surgery requiring invasive monitoring and Trendelenburg position during the procedure
Who cannot join
- age under 18 years
- weight under 40 kg
- preoperative left ventricular ejection fraction (LVEF) less than 45%
- severe heart valve disease
- known intra-and/or extracardiac shunt
- pulmonary hypertension
Show all 9Show fewer
- preoperative circulatory shock with need for hemodynamic inotropic support
- redo surgery
- pregnancy
Trial locations and contacts
1 site in 1 country.
About this study
Official title: Comparability of Transesophageal Echocardiography and Continuous Mini-invasive FloTrac/Vigileo System (© Edwards Lifesciences) for the Determination of Cardiac Output in Three Different Positions During General Anesthesia
The use of cardiac output monitoring to guide intraoperative fluid management and inotropic drugs as part of a hemodynamic therapy algorithm reduce the complication rate in major abdominal surgery. The FloTrac/Vigileo system (© Edwards Lifesciences) (Edwards Lifesciences, Irvine, CA) device estimate cardiac output by using arterial pulse contour analysis. The accuracy of FloTrac/Vigileo have been proven in patients with normal cardiac index. Most of studies regarding FloTrac/Vigileo were performed in patients in horizontal supine position, which is not usually the reality in the operation theater during abdominal surgery. Therefore, the investigators realized this monocentric prospective clinical trial to study the accuracy and trending ability of the fourth generation FloTrac/Vigileo system cardiac output estimation in three different positions (horizontal supine, Trendelenburg and reverse Trendelenburg positions) in anesthetized patients undergoing elective major abdominal surgery. The reference method of cardiac output measurement used was the transesophageal echocardiography.
- Conditions
- Cardiac Output
- Being tested
- FloTrac/Vigileo system (© Edwards Lifesciences) (Edwards Lifesciences, Irvine, CA) device
- Keywords
- Cardiac output monitoring, Mini-invasive
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
FloTrac/Vigileo system (© Edwards Lifesciences) (Edwards Lifesciences, Irvine, CA) deviceDevice
Concomitant cardiac output measurement with transesophageal echocardiography and with the FloTrac/Vigileo system (© Edwards Lifesciences) (Edwards Lifesciences, Irvine, CA) device in 3 different positions (horizontal supine, Trendelenburg and reverse Trendelenburg position).
| Study group | Role | What they receive |
|---|---|---|
| Group 1 | 1. st cardiac output measurement (horizontal supine position): Transesophageal echocardiographic cardiac output measurements, data recorded and in the meantime the data of the FloTrac system (© Edwards Lifesciences) monitor recorded also.
2. nd cardiac output measurement (Trendelenburg position): The operating table was then tilted in - 30 ° Trendelenburg (head-down) position. Echocardiographic measurements and FloTrac system (© Edwards Lifesciences) data were recorded.
3. rd cardiac output measurement: The patients were positioned from Trendelenburg to reverse-Trendelenburg, the above-described data were recorded again. Receives: Device: FloTrac/Vigileo system (© Edwards Lifesciences) (Edwards Lifesciences, Irvine, CA) device | |
| Group 2 | 1. st cardiac output measurement (horizontal supine position): Transesophageal echocardiographic cardiac output measurements, data recorded and in the meantime the data of the FloTrac system (© Edwards Lifesciences) monitor recorded also.
2. nd cardiac output measurement (reverse Trendelenburg position): The operating table was then tilted in + 30 ° reverse Trendelenburg (head-up) position. Echocardiographic measurements and FloTrac system (© Edwards Lifesciences) data were recorded.
3. rd cardiac output measurement: The patients were positioned from reverse Trendelenburg to Trendelenburg, the above-described data were recorded again. Receives: Device: FloTrac/Vigileo system (© Edwards Lifesciences) (Edwards Lifesciences, Irvine, CA) device |
What is being measured
The primary outcome is the main question the study is designed to answer.
To verify the FloTrac/Vigileo's ability to estimate cardiac output (L/min) in horizontal supine position.
To study the fourth generation FloTrac/Vigileo system accuracy to estimate cardiac output (L/min) in horizontal supine position in anesthetized patients undergoing elective major abdominal surgery. The reference method of cardiac output (L/min) measurement used was the transesophageal echocardiography. The two cardiac output measurement techniques were assessed using Bland-Altman method.
Measured: Baseline
To verify the FloTrac/Vigileo's ability to estimate cardiac output (L/min) in Trendelenburg position.
To study the fourth generation FloTrac/Vigileo system accuracy to estimate cardiac output (L/min) in Trendelenburg position in anesthetized patients undergoing elective major abdominal surgery. The reference method of cardiac output (L/min) measurement used was the transesophageal echocardiography. The two cardiac output measurement techniques were assessed using Bland-Altman method.
Measured: Baseline
To verify the FloTrac/Vigileo's ability to estimate cardiac output (L/min) in reverse Trendelenburg position.
To study the fourth generation FloTrac/Vigileo system accuracy to estimate cardiac output (L/min) in reverse Trendelenburg position in anesthetized patients undergoing elective major abdominal surgery. The reference method of cardiac output (L/min) measurement used was the transesophageal echocardiography. The two cardiac output measurement techniques were assessed using Bland-Altman method.
Measured: Baseline
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted19 Aug 2022
- Study start1 Oct 2021
- Primary completion31 Jan 2022
- Study completion30 Jun 2022
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (6)Papers the sponsor has linked to this study.
- Other trials for Cardiac OutputStudies of the same condition, open and under way.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Observational
- Observational model
- Other
- Time perspective
- Prospective
- Enrolment
- 40 participants (actual)
Sponsor and investigators
- Lead sponsor
- Université Libre de Bruxelles
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Lucelia Fernandes Ricciardi, Université Libre de Bruxelles
- Investigators
- Lucélia FERNANDES RICCIARDI, M.D., Principal investigator, Université Libre de Bruxelles
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT05508711
- Sponsor's protocol ID
- B4062021000220
- Status last verified
- Aug 2022
- First submitted
- 15 Aug 2022
- Last updated
- 19 Aug 2022
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
Vender JS. Clinical utilization of pulmonary artery catheter monitoring. Int Anesthesiol Clin. 1993 Summer;31(3):57-85. doi: 10.1097/00004311-199331030-00006.
PubMed 8375911Mayer J, Boldt J, Wolf MW, Lang J, Suttner S. Cardiac output derived from arterial pressure waveform analysis in patients undergoing cardiac surgery: validity of a second generation device. Anesth Analg. 2008 Mar;106(3):867-72, table of contents. doi: 10.1213/ane.0b013e318161964d.
PubMed 18292432McLean AS, Huang SJ, Kot M, Rajamani A, Hoyling L. Comparison of cardiac output measurements in critically ill patients: FloTrac/Vigileo vs transthoracic Doppler echocardiography. Anaesth Intensive Care. 2011 Jul;39(4):590-8. doi: 10.1177/0310057X1103900409.
PubMed 21823375Suehiro K, Tanaka K, Mikawa M, Uchihara Y, Matsuyama T, Matsuura T, Funao T, Yamada T, Mori T, Nishikawa K. Improved Performance of the Fourth-Generation FloTrac/Vigileo System for Tracking Cardiac Output Changes. J Cardiothorac Vasc Anesth. 2015;29(3):656-62. doi: 10.1053/j.jvca.2014.07.022. Epub 2014 Nov 14.
PubMed 25440654Maeda T, Hamaguchi E, Kubo N, Shimokawa A, Kanazawa H, Ohnishi Y. The accuracy and trending ability of cardiac index measured by the fourth-generation FloTrac/Vigileo system and the Fick method in cardiac surgery patients. J Clin Monit Comput. 2019 Oct;33(5):767-776. doi: 10.1007/s10877-018-0217-1. Epub 2018 Nov 7.
PubMed 30406422Pearse RM, Harrison DA, MacDonald N, Gillies MA, Blunt M, Ackland G, Grocott MP, Ahern A, Griggs K, Scott R, Hinds C, Rowan K; OPTIMISE Study Group. Effect of a perioperative, cardiac output-guided hemodynamic therapy algorithm on outcomes following major gastrointestinal surgery: a randomized clinical trial and systematic review. JAMA. 2014 Jun 4;311(21):2181-90. doi: 10.1001/jama.2014.5305.
PubMed 24842135
Study at a glance
From the registry record, last updated by the sponsor on 19 Aug 2022. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Comparability of Transesophageal Echocardiography and Continuous Mini-invasive FloTrac/Vigileo System (© Edwards Lifesciences) for the Determination of Cardiac Output in Three Different Positions During General Anesthesia
- ClinicalTrials.gov ID
- NCT05508711
- Acronym / sponsor ID
- B4062021000220
- Conditions
- Cardiac Output
- Keywords
- Cardiac output monitoring, Mini-invasive
- Study type
- Observational
- Recruitment status
- Completed
- Enrolment
- 40 participants (actual)
- Lead sponsor
- Université Libre de BruxellesUniversity, hospital or other
- Study start
- 1 Oct 2021 (actual)
- Primary completion
- 31 Jan 2022 (actual)
- Study completion
- 30 Jun 2022 (actual)
- First posted
- 19 Aug 2022 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The use of cardiac output monitoring to guide intraoperative fluid management and inotropic drugs as part of a hemodynamic therapy algorithm reduce the complication rate in major abdominal surgery. The FloTrac/Vigileo system (© Edwards Lifesciences) (Edwards Lifesciences, Irvine, CA) device estimate cardiac output by using arterial pulse contour analysis. The accuracy of FloTrac/Vigileo have been proven in patients with normal cardiac index. Most of studies regarding FloTrac/Vigileo were performed in patients in horizontal supine position, which is not usually the reality in the operation theater during abdominal surgery. Therefore, the investigators realized this monocentric prospective clinical trial to study the accuracy and trending ability of the fourth generation FloTrac/Vigileo system cardiac output estimation in three different positions (horizontal supine, Trendelenburg and reverse Trendelenburg positions) in anesthetized patients undergoing elective major abdominal surgery. The reference method of cardiac output measurement used was the transesophageal echocardiography.
Study design
- Observational model
- Other
- Time perspective
- Prospective
- Number of arms
- 2
| Arm | Type | Receives |
|---|---|---|
| Group 1 | – | Device: FloTrac/Vigileo system (© Edwards Lifesciences) (Edwards Lifesciences, Irvine, CA) device1. st cardiac output measurement (horizontal supine position): Transesophageal echocardiographic cardiac output measurements, data recorded and in the meantime the data of the FloTrac system (© Edwards Lifesciences) monitor recorded also. 2. nd cardiac output measurement (Trendelenburg position): The operating table was then tilted in - 30 ° Trendelenburg (head-down) position. Echocardiographic measurements and FloTrac system (© Edwards Lifesciences) data were recorded. 3. rd cardiac output measurement: The patients were positioned from Trendelenburg to reverse-Trendelenburg, the above-described data were recorded again. |
| Group 2 | – | Device: FloTrac/Vigileo system (© Edwards Lifesciences) (Edwards Lifesciences, Irvine, CA) device1. st cardiac output measurement (horizontal supine position): Transesophageal echocardiographic cardiac output measurements, data recorded and in the meantime the data of the FloTrac system (© Edwards Lifesciences) monitor recorded also. 2. nd cardiac output measurement (reverse Trendelenburg position): The operating table was then tilted in + 30 ° reverse Trendelenburg (head-up) position. Echocardiographic measurements and FloTrac system (© Edwards Lifesciences) data were recorded. 3. rd cardiac output measurement: The patients were positioned from reverse Trendelenburg to Trendelenburg, the above-described data were recorded again. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
- Study population
- Patients without heart disease or hemodynamic instability scheduled for elective pancreatic, bladder or liver surgery requiring invasive monitoring and Trendelenburg position during the procedure.
Key inclusion criteria (1 listed)
- patients scheduled for elective pancreatic, bladder or liver surgery requiring invasive monitoring and Trendelenburg position during the procedure
Key exclusion criteria (9 listed)
- age under 18 years
- weight under 40 kg
- preoperative left ventricular ejection fraction (LVEF) less than 45%
- severe heart valve disease
- known intra-and/or extracardiac shunt
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| FloTrac/Vigileo system (© Edwards Lifesciences) (Edwards Lifesciences, Irvine, CA) deviceConcomitant cardiac output measurement with transesophageal echocardiography and with the FloTrac/Vigileo system (© Edwards Lifesciences) (Edwards Lifesciences, Irvine, CA) device in 3 different positions (horizontal supine, Trendelenburg and reverse Trendelenburg position). | Device | Group 1, Group 2 |
Primary outcome
To verify the FloTrac/Vigileo's ability to estimate cardiac output (L/min) in horizontal supine position.
Time frame: Baseline
To study the fourth generation FloTrac/Vigileo system accuracy to estimate cardiac output (L/min) in horizontal supine position in anesthetized patients undergoing elective major abdominal surgery. The reference method of cardiac output (L/min) measurement used was the transesophageal echocardiography. The two cardiac output measurement techniques were assessed using Bland-Altman method.
To verify the FloTrac/Vigileo's ability to estimate cardiac output (L/min) in Trendelenburg position.
Time frame: Baseline
To study the fourth generation FloTrac/Vigileo system accuracy to estimate cardiac output (L/min) in Trendelenburg position in anesthetized patients undergoing elective major abdominal surgery. The reference method of cardiac output (L/min) measurement used was the transesophageal echocardiography. The two cardiac output measurement techniques were assessed using Bland-Altman method.
To verify the FloTrac/Vigileo's ability to estimate cardiac output (L/min) in reverse Trendelenburg position.
Time frame: Baseline
To study the fourth generation FloTrac/Vigileo system accuracy to estimate cardiac output (L/min) in reverse Trendelenburg position in anesthetized patients undergoing elective major abdominal surgery. The reference method of cardiac output (L/min) measurement used was the transesophageal echocardiography. The two cardiac output measurement techniques were assessed using Bland-Altman method.
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 19 Aug 2022.
- Background: PubMed 8375911Vender JS. Clinical utilization of pulmonary artery catheter monitoring. Int Anesthesiol Clin. 1993 Summer;31(3):57-85. doi: 10.1097/00004311-199331030-00006.
- Background: PubMed 18292432Mayer J, Boldt J, Wolf MW, Lang J, Suttner S. Cardiac output derived from arterial pressure waveform analysis in patients undergoing cardiac surgery: validity of a second generation device. Anesth Analg. 2008 Mar;106(3):867-72, table of contents. doi: 10.1213/ane.0b013e318161964d.
- Background: PubMed 21823375McLean AS, Huang SJ, Kot M, Rajamani A, Hoyling L. Comparison of cardiac output measurements in critically ill patients: FloTrac/Vigileo vs transthoracic Doppler echocardiography. Anaesth Intensive Care. 2011 Jul;39(4):590-8. doi: 10.1177/0310057X1103900409.
- Background: PubMed 25440654Suehiro K, Tanaka K, Mikawa M, Uchihara Y, Matsuyama T, Matsuura T, Funao T, Yamada T, Mori T, Nishikawa K. Improved Performance of the Fourth-Generation FloTrac/Vigileo System for Tracking Cardiac Output Changes. J Cardiothorac Vasc Anesth. 2015;29(3):656-62. doi: 10.1053/j.jvca.2014.07.022. Epub 2014 Nov 14.
- Background: PubMed 30406422Maeda T, Hamaguchi E, Kubo N, Shimokawa A, Kanazawa H, Ohnishi Y. The accuracy and trending ability of cardiac index measured by the fourth-generation FloTrac/Vigileo system and the Fick method in cardiac surgery patients. J Clin Monit Comput. 2019 Oct;33(5):767-776. doi: 10.1007/s10877-018-0217-1. Epub 2018 Nov 7.
- Results publication: PubMed 24842135Pearse RM, Harrison DA, MacDonald N, Gillies MA, Blunt M, Ackland G, Grocott MP, Ahern A, Griggs K, Scott R, Hinds C, Rowan K; OPTIMISE Study Group. Effect of a perioperative, cardiac output-guided hemodynamic therapy algorithm on outcomes following major gastrointestinal surgery: a randomized clinical trial and systematic review. JAMA. 2014 Jun 4;311(21):2181-90. doi: 10.1001/jama.2014.5305.
- Individual participant dataSharing planned: No
Related trials for Cardiac Output
Not yet recruitingObservational study
Ultrasound-Calibrated Pulse Contour Cardiac Output Monitoring: Value and Accuracy in Hemodynamic Care
Sepsis, Circulatory Instability
RecruitingObservational study
Comparison of PPV and LVOT VTI During Passive Leg Raising to Predict Fluid Responsiveness
Hemodynamic Instability, Hypovolemia
Not yet recruiting
UltraTrac for Cardiac Output Monitoring in Congenital Heart Disease
Congenital Heart Disease, Cardiac Output
Active, not recruitingObservational study
Post-Induction Low Cardiac Output Syndrome in Coronary Artery Bypass Graft Surgery
Cardiac Output, Low, Coronary Arterial Disease
Not yet recruiting
Bedside Assessment of Right Ventricular Output Lying in Prone Or Supine
Right Ventricular Function, Prone Position
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Lucélia FERNANDES RICCIARDI, M.D. principal investigator
Université Libre de Bruxelles
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
An observational study of Cardiac Output, run by Université Libre de Bruxelles at 1 site in Belgium.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 1 inclusion and 9 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 19 Aug 2022. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Belgium. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
To verify the FloTrac/Vigileo's ability to estimate cardiac output (L/min) in horizontal supine position. (time frame: Baseline). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT05508711, which also lists 6 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 19 Aug 2022.