AzTrials
AzTrials

Fracture Tibia3DFRGNCT05741892

3D Planned Surgery of Acute Fractures Performed With 3D Guides Printed at the Point of Care

A study testing Fracture reposition with 3D printed patient specific repositions guides in people with Fracture Tibia and Fracture Femur, run by Insel Gruppe AG, University Hospital Bern at 1 site in Switzerland.

Unknown status

Status not confirmed. The sponsor has not verified this record for over two years, so it may be out of date.

Official record
Search all trials

Trial summary

The aim of the study is to assess the accuracy of fracture reduction performed with surgical guides designed and 3D printed at the point of care in comminuted fractures of femur- and tibia-shaft. Read more about this study

Who is it for?
Ages 18 to 99 years
What is being tested?
Fracture reposition with 3D printed patient specific repositions guides
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
15 participants
Where
1 siteSwitzerland
Study dates
1 Apr 2023to 1 Dec 2025
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 99 years
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Age between 18 and 99 years
  • Comminuted shaft fracture of tibia or femur
  • Intact contralateral tibia or femur
  • Patient willing to participate and sign the informed consent
  • Clear indication of surgical treatment

Who cannot join

  • Refusal to sign the informed consent
  • Abnormal contralateral bony anatomy (previous surgeries, poliomyelitis, previous injury, implants)
  • Pregnancy
  • Acute tumor or previous tumor disease
  • Acute infection

Trial locations and contacts

1 site in 1 country.

Switzerland1 site, 1 recruiting
  • Universitätsklinik für Orthopädische Chirurgie und Traumatologie

    Bern, 3010

    Andreas Hecker, MD, 031 632 21 11 ext. 0041, andreas.hecker@insel.ch

    Silvan Hess, MD

    Recruiting

Other trials in Switzerland

About this study

Official title: 3D Planned Surgery of Acute Fractures Performed With 3D Guides Printed at the Point of Care - a Prospective Case Series

The aim of the study is to assess the accuracy of fracture reduction performed with surgical guides designed and 3D printed at the point of care in comminuted fractures of femur- and tibia-shaft.

Read the detailed description

The 3D planning of surgeries and their execution with 3D printed templates adapted to the individual patient is an established procedure for elective surgeries such as corrective osteotomies for mal-united fractures. Currently, the planning and production of 3D templates are performed mainly by external companies. The duration until delivery usually exceeds four weeks. Therefore, it is not possible to use them in acute cases (e.g. acute fractures) that need to be treated surgically within a few days.

The most frequent postoperative deformity in long bone shaft fractures is malrotation. In femoral fractures, clinically relevant rotational errors (>15°) occur in up to 40% of cases after surgical treatment, which either results in a poor clinical outcome or requires revision surgery. In tibial diaphyseal fractures, up to 50% of rotational errors have been reported. The higher the degree of comminution the higher the chances of malrotation postoperatively. Due to the comminuted situation, no reliable bony references exist intraoperatively and the surgeon can only estimate the correct length, axis and, rotation based on the contralateral leg. This ultimately leads to a high number of revision surgeries or poor outcomes. Porcine and human cadaveric feasibility studies conducted by the study team utilizing site 3D planned and printed reduction guides showed excellent accuracy of fracture reduction.

This project aims to apply this technique to the clinical setting by conducting a clinical study. The accuracy of 3D planned surgery performed with surgical guides designed and printed at the point of care will be assessed and the complication rate will be compared to the known literature.

It was hypothesized that the mean deviation between the measured postoperative rotational alignment and planned rotation alignment in patients treated for comminuted fractures of femur- and tibia-shaft treated using 3D printed reposition guides will be less than 5°. Additionally, it was hypothesized that the rate of clinically relevant deviations between postoperative rotational alignment (e.g. 15°) and planned rotation in patients treated for comminuted fractures of femur- and tibia-shaft treated using 3D printed reposition guides will be less than 10%.

Being tested
Fracture reposition with 3D printed patient specific repositions guides
Keywords
Femur, Tibia, Comminuted fracture, 3D printing, personalized medicine
Medical subject headings
Tibial Fractures, Femoral Fractures, Fractures, Comminuted

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Fracture reposition with 3D printed patient specific repositions guidesDevice

    Comminuted tibial- or/and femur shaft fractures will be treated using 3D printed patient-specific repositions guides.

Study groups in NCT05741892
Study groupRoleWhat they receive
3D fracture reposition guide groupExperimentalComminuted tibial- or/and femur shaft fractures will be treated using 3D printed patient-specific repositions guides.
Receives: Device: Fracture reposition with 3D printed patient specific repositions guides

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Rotational deviation (Axial plane deviation) in degree

    Planned rotational alignment versus postoperative rotational alignment.

    Measured: Between 1 to 7 days postoperative, depending on the patients status

Secondary outcomes (3)
  1. Length deviation in mm

    Planed length versus postoperative length

    Measured: Between 1 to 7 days postoperative, depending on the patients status

  2. Frontal plane deviation in degree

    Planned varus/valgus alignment versus postoperative varus/valgus alignment

    Measured: Between 1 to 7 days postoperative, depending on the patients status

  3. Sagittal plane deviation in degree

    Planned flexion/extension of the proximal and distal fracture fragments compared to the postoperative position.

    Measured: Between 1 to 7 days postoperative, depending on the patients status

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted23 Feb 2023
  2. Study start1 Apr 2023
  3. Primary completion1 Dec 2024 (estimated)
  4. Study completion1 Dec 2025 (estimated)

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Treatment
Allocation
Not applicable
Intervention model
Single group
Model description
Prospective case series
Masking
None (open label)
Enrolment
15 participants (estimated)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05741892
Sponsor's protocol ID
5364
Acronym
3DFRG
Status last verified
Dec 2023
First submitted
13 Feb 2023
Last updated
6 Dec 2023
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

A study testing Fracture reposition with 3D printed patient specific repositions guides in people with Fracture Tibia and Fracture Femur, run by Insel Gruppe AG, University Hospital Bern at 1 site in Switzerland.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: status not confirmed, as of the sponsor's last update on 6 Dec 2023. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Switzerland. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Results are not available in the source record.

How can a doctor refer a patient or contact the research team?

Contact Hecker Andreas, MD (031 632 21 11 ext. 0041, andreas.hecker@insel.ch), or a site near the patient. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Rotational deviation (Axial plane deviation) in degree (time frame: Between 1 to 7 days postoperative, depending on the patients status). It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 6 Dec 2023.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in