Pulse oximeters are common medical devices used to measure blood oxygen saturation (SpO2). These devices are either stand-alone or integrated into physiologic monitoring systems, using 2 wavelengths of light to determine SpO2. Read more about this study

Who is it for?
Ages 18 to 65 yearsHealthy volunteers can take part
Conditions the study is for
Oxygen Saturation
What is being tested?
Clarifi Modulum, Perimed PeriFlux 5000 and Apple Watch Oxygen Sensor
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
20 participants
Where
2 sitesUnited States
Study dates
9 Mar 2022to 7 Jul 2022
Phase
Interventional
Are there results?
Yes, posted in the registrySummary in the doctors' view

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 to 65 years
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Who may be able to join

  • Healthy volunteers
  • Able to understand and complete the Informed Consent
  • Both males and females
  • Age between 18-65 years
  • All ethnic backgrounds

Who cannot join

  • Patients or limited health conditions
  • Smoking tobacco product
  • Prisoners
  • Cannot consent for themselves

Trial locations and contacts

2 sites in 1 country.

United States2 sites
  • Indiana University, School of Medicine

    Indianapolis, Indiana, 15219/46202

  • Surya C. Gnyawali, University of Pittsburgh, UPMC

    Pittsburgh, Pennsylvania, 15227

Other trials in United States

About this study

Official title: Measurement of Oxygen Saturation in Healthy Human Volunteers Before, During, and After Hyperemic Events Using Multi-Modal Techniques: Spatial Frequency Domain Imaging, Transcutaneous Oxygen Measurement, Pulse Oximeter, and Apple Watch

Pulse oximeters are common medical devices used to measure blood oxygen saturation (SpO2). These devices are either stand-alone or integrated into physiologic monitoring systems, using 2 wavelengths of light to determine SpO2. With recent advances in technology, Spatial Frequency Domain Imaging (SFDI) uses a range of light wavelengths from red to near-infrared (NIR), and smartphones such as Apple Watch, and transcutaneous oximetry TCOM now have pulse oximetry capabilities. Since it is possible that most patients could utilize this technology, we sought to assess the accuracy, reliability, and usability of these oximeters and compare outcomes. In this study, a cohort of 20 healthy volunteers above the age of 18 including males and females of different skin colors will be assessed at the same site and data will be compared. We aim to provide a set of data that will support the clinical and scientific community and identify more than one reliable skin oxygen measurement modality.

Read the detailed description

The subjects will go through a questionnaire session about their medical history by a designated study team member. The questionnaire data will be placed in RedCap using a subject ID that cannot be linked back to the subject. Then the subject will consent and be enrolled. Then the non-invasive data-collecting procedure will start on the following equipment.

Spatial Frequency Domain Imaging (SFDI): During the consenting period, the Modulim equipment will be calibrated and set up ready for scanning. The subject's volar aspect of the thumb along with the palm surface will be ready to target the optical camera head. Actual scanning takes less than 60 seconds. The images will be processed offline. During processing 3-5 different regions of interest (ROI) will be taken to measure the oxygen parameters such as tissue oxygen saturation (StO2), oxy-hemoglobin (HbO2), deoxy-hemoglobin (HbR), superficial hemoglobin (HbT1, sub-surface hemoglobin (HbT2). The model used is a Clarifi Modulim Transcutaneous oxygen monitoring (TCOM): Transcutaneous oxygen monitoring (TCOM or TcpO2) is a noninvasive, clinically-approved method to obtain skin oxygen levels. The method is quantitative and measures oxygen delivery to the skin from underlying tissue. Before positioning the electrode, an adhesive fixation ring will be placed on the dry skin on the volar aspect of the thumb and an electrolyte as a contact liquid will be filled in half and the probe is aligned into it by rotating clockwise to fasten it. The recording will be started and waited for the oxygen level to stabilize and a fixed value will be recorded. The model used is a Perimed PeriFlux 5000. The probe will be heated to about 45 degrees C. Although this device has other options, only the measurement of O2 will be performed using this device.

Apple Watch Oxygen Sensor: Smartwatch blood oxygen sensors also measure blood oxygen levels in the tissue. Apple Watch Series 6 introduced this new feature for monitoring blood oxygen levels using light-emitting diodes (LEDs) at the back of apple watches. A low blood oxygen level can be indicative of a serious health issue that needs immediate attention. The apple watch is equipped with green, red, and infrared LEDs that shine light onto the blood vessels in the wrist, with photodiodes measuring the amount of light reflected back. Apple's algorithms use this information to calculate the color of the blood, which is an indication of how much oxygen is in the blood. Bright red blood is well-oxygenated, while darker blood has less oxygen. This can measure blood oxygen levels between 70 and 100 percent. Most healthy people have blood oxygen levels that range from 95 to 100 percent. The apple watch sensor will be positioned on the user's preferred wrist.

Pulse Oximeter for Oxygen Monitoring: The pulse oximeter enables transcutaneous monitoring of the oxygen saturation of hemoglobin in arterial blood (StO2). Pulse oximetry is so widely prevalent in medical care that it is often regarded as a fifth vital sign[3]. It is important to understand how the technology functions as well as its limitations. To recognize the settings in which pulse oximeter readings of oxygen saturation (SpO2), an understanding of two basic principles of pulse oximetry is required: (i) how oxyhemoglobin (HbO2) is distinguished from deoxyhemoglobin (HbR) and (ii) how the SpO2 is calculated only from the arterial compartment of blood. Pulse oximetry is based on the principle that HbO2 and HbR differentially absorb red and near-infrared (IR) light. It is fortuitous that HbO2 and HbR have significant differences in absorption at red and near-IR light because these two wavelengths penetrate tissues well whereas blue, green, yellow, and far-IR light are significantly absorbed by non-vascular tissues and water [3]. HbO2 absorbs greater amounts of IR light and lower amounts of red light than does HbR; this is consistent with experience - well-oxygenated blood with its higher concentrations of HbO2 appears bright red to the eye because it scatters more red light than does HbR. On the other hand, HHR absorbs more red light and appears less red. Exploiting this difference in light absorption properties between HbO2 and HbR, pulse oximeters emit two wavelengths of light, red at 660 nm and near-IR at 940 nm from a pair of small light-emitting diodes located in one arm of the finger probe. The light that is transmitted through the finger is then detected by a photodiode on the opposite arm of the probe. In this study, the volar aspect of the thumb and index finger of the subject will be used to measure SpO2.

Being tested
Clarifi Modulum, Perimed PeriFlux 5000, Apple Watch Oxygen Sensor, Innovo iP 900AP
Keywords
SFDI, oxygenation, healthy volunteers

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Clarifi ModulumDevice

    Also called Spatial Frequency Domain Imaging (SFDI)

    During consenting period, the Modulim equipment will be calibrated and setup ready for scanning. Subject's volar aspect of the thumb along with the palm surface will be ready to target the optical camera head. Actual scanning takes less than 60 seconds. The images will be processed offline. During processing 3-5 different regions of interest will be taken to measure the oxygen parameters such as tissue oxygen saturation, oxy-hemoglobin, deoxy-hemoglobin, superficial hemoglobin, and sub-surface hemoglobin.

  • Perimed PeriFlux 5000Device

    Also called Transcutaneous oxygen monitoring (TCOM)

    Transcutaneous oxygen monitoring (TCOM or TcpO2) is a noninvasive, clinically-approved method to obtain skin oxygen levels. The method is quantitative, and measures oxygen delivery to the skin from underlying tissue. Before positioning the electrode, an adhesive fixation ring will be placed on the dry skin on the volar aspect of the thumb and an electrolyte as a contact liquid will be filled half and the probe is aligned into it by rotating clock-wise to fasten it. Recording will be started and waited for the oxygen level to stabilize and a fixed value will be recorded. The probe will be heated to about 45oC. Although this device has other options, only the measurement of O2 will be performed using this device.

  • Apple Watch Oxygen SensorDevice

    The apple watch is equipped with green, red, and infrared LEDs that shine light onto the blood vessels in the wrist, with photodiodes measuring the amount of light reflected back. Apple's algorithms use this information to calculate the color of the blood, which is an indication of how much oxygen is in the blood. Bright red blood is well oxygenated, while darker blood has less oxygen. This can measure blood oxygen levels between 70 and 100 percent. Most healthy people have blood oxygen levels that range from 95 to 100 percent. The apple watch sensor will be positioned on the user's preferred wrist.

  • Innovo iP 900APDevice

    Also called Pulse Oximeter

    The pulse oximeter enables transcutaneous monitoring of the oxygen saturation of hemoglobin in arterial blood. In this study, volar aspect of thumb and index finder of the subject will be used to measure blood oxygen saturation.

Study groups in NCT05784103
Study groupRoleWhat they receive
Multi-Modal Measurement of Oxygen SaturationOtherDuring a single study visit, participants will have oxygen saturation measured with a number of oximetry devices including Spatial Frequency Domain Imaging (SFDI), Transcutaneous oxygen monitoring (TCOM), an Apple Watch Oxygen Sensor, and a Pulse Oximeter. Each device will be used to measure oxygen saturation of the thumb and index fingers at rest, during occlusion of blood flow to the arm (using an inflated blood pressure cuff applied to the arm), and during the hyperemic post-occlusion period. Completion of all planned interventions may take up to 2 hours on the study visit day.
Receives: Device: Clarifi Modulum; Device: Perimed PeriFlux 5000; Device: Apple Watch Oxygen Sensor; Device: Innovo iP 900AP

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Device-wise Comparison of Tissue Oxygenation Measurement

    4 devices used to measures the tissue oxygen saturation on healthy human volunteers

    Measured: Visit 1, up to 2 hours in duration

  2. Male vs Female Comparison of Tissue Oxygenation Measurement

    Goal is to see if there is a variation in the gender biased. The criteria for the male vs female comparison were considered to find better or worse outcomes.

    Measured: 1 visit, 2hrs

  3. Skin Type Based Comparison of Tissue Oxygenation

    Fitzpatrick chart-based skin categorization of the skin type. The criteria for the Fitzpatrick Skin Type grades IV, II \& III were matched with Fitzpatric table and grades were considered to find better or worse outcomes.

    Please Note: The skin type analysis was performed irrespective to the devices. Only skin types were considered. So, there is no need of adding arms/groups other than the (1) Skin type IV and (2) the skin type II\& III.

    Measured: 1 visit, 2hrs duration

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted24 Mar 2023
  2. Study start9 Mar 2022
  3. Primary completion7 Jul 2022
  4. Study completion7 Jul 2022

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Not applicable
Intervention model
Single group
Masking
None (open label)
Enrolment
20 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05784103
Sponsor's protocol ID
13895
Status last verified
Nov 2023
First submitted
13 Mar 2023
Last updated
29 Nov 2023
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
Yes
Individual data sharing
No: Through Publication

Publications

  • Jones MD, Taylor JL, Barry BK. Occlusion of blood flow attenuates exercise-induced hypoalgesia in the occluded limb of healthy adults. J Appl Physiol (1985). 2017 May 1;122(5):1284-1291. doi: 10.1152/japplphysiol.01004.2016. Epub 2017 Feb 9.

    PubMed 28183823
  • El Masry M, Li R, Balasubramani GK, Roy S, Sen CK, Gnyawali SC. Comparative assessment of healthy tissue oxygenation using near-infrared imaging, transcutaneous oxygen measurement, and plethysmography. Sci Rep. 2025 Aug 19;15(1):30424. doi: 10.1038/s41598-025-15767-2.

    PubMed 40830190

Questions about this trial

What is this clinical trial studying?

A study testing Clarifi Modulum, Perimed PeriFlux 5000 and Apple Watch Oxygen Sensor in people with Oxygen Saturation, run by Indiana University at 2 sites in United States.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 5 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 29 Nov 2023. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 2 sites in United States. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

Yes. Results are posted in the registry (first posted 24 Nov 2023). A summary is in the For doctors view, and the full results are on ClinicalTrials.gov.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Device-wise Comparison of Tissue Oxygenation Measurement (time frame: Visit 1, up to 2 hours in duration). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT05784103, which also lists 2 linked publications.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 29 Nov 2023.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in