Prosthesis UserNCT05790148
Precision of Three Different Scanbodies Used for Direct Digitalization Technique
A study testing 3Shape in people with Prosthesis User and Digitalism, run by Hacettepe University at 1 site in Turkey (Türkiye).
Trial summary
The goal of this clinical trials to evaluate precision of different scanbodies in same participant group. The main guestion it aim to answer is: 1. Are the precision of the three different scanbodies used in direct digitalization the same for the produce of implant-supported prostheses? Participants are healty and… Read more about this study
- Who is it for?
- Ages 18 years and olderHealthy volunteers can take part
- Conditions the study is for
- Prosthesis User, Digitalism
- What is being tested?
- 3Shape
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 25 participants
- Where
- 1 siteTurkey (Türkiye)
- Study dates
- 11 Aug 2020to 11 Jun 2022
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- Healthy volunteers accepted
- Adult, Older adult
Who may be able to join
- Be willing to voluntarily participate in the study after reading the informed consent form.
- Adult patient over 18 years of age who has completed growth and development
- Partial edentulism in the functional region for a two-implant-supported restoration with two or three occlusal members
- Having a fixed dentition in the opposing arch
- The occlusal relationship between the jaws does not require vertical and horizontal prosthetic treatment.
- Having bone-level implants placed with "straightforward" surgery according to the SAC classification system [248] and without advanced surgical technique
Who cannot join
- Not voluntarily agreeing to participate in the study after reading the informed consent form
- Having one or more of the conditions for which implant treatment is strictly contraindicated (patients who have received radiation therapy, bone cancer, metabolic disorders)
- Having systemic (steroid therapy, uncontrolled diabetes, immunological disorders, pregnancy) risk factors for implant treatment
- Having local (periodontal discomfort, bruxism, poor oral hygiene) risk factors for implant treatment
Trial locations and contacts
1 site in 1 country.
Turkey (Türkiye)1 site
Hacettepe University Faculty of Dentistry Department of Prosthodontics
Ankara, Altındağ, 06230
About this study
Official title: Precision of Different Scanbodies Used for Direct Digital Impression in Fabrication of Implant Supported Fixed Prosthesis: A Methodologic Clinical Study
The goal of this clinical trials to evaluate precision of different scanbodies in same participant group. The main guestion it aim to answer is:
- Are the precision of the three different scanbodies used in direct digitalization the same for the produce of implant-supported prostheses?
Participants are healty and have short edentulous span in posterior region that will receive implant-supported prostheses.
Read the detailed description
Twenty-five patients receiving two implant supported restorations in treatment of short-span partial edentulism were enrolled into the study. Three different scanbodies, original, non-original and generic, were employed for direct digitalization technique. Full contour PMMA restorations were CAD/CAM fabricated from each digital record, and were evaluated in terms of implant fit, axial- and occlusal-contact. Additionally, patient's impressions for digitalization and delivery procedures were recorded using a visual analog scale. Scanbody scan recordings were subjected to reverse engineering for analytical evaluation of 3D virtual implant positioning.
- Conditions
- Prosthesis User, Digitalism
- Being tested
- 3Shape
- Keywords
- digital dentistry, intraoral scanner, implant scanbody
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
3ShapeDevice
Also called Straumann (CARES Mono Scanbody; Straumann Holding AG), Medentika (Scanbody 2.generation; MEDENTIKA GmbH, Hügelsheim, Germany) , 3Shape (3Shape A/S, Copenhagen, Denmark)
original (Straumann), non-original (Medentika) and generic scan-bodies (3Shape) were utilized for direct digitalization using intraoral scanner with image stitching algorithm. Full contour temporary restorations were fabricated from each digital record, and were evaluated in terms of clinical and analytical.
| Study group | Role | What they receive |
|---|---|---|
| Evaluation precision of different scan-bodies | Other | Three different brand scanbodies (Straumann, Medentika, 3Shape) that applied in same participant group with randomization are used in this clinical study. These three different scan bodies are digitized using an intraoral scanner. Three different temporary restorations are designed in the CAD program and three different bridges are produced with the milling technique using the temporary restoration block. Clinical and analytic evaluations were perform and primarly, seconderly outcomes were achieved. Receives: Device: 3Shape |
What is being measured
The primary outcome is the main question the study is designed to answer.
Clinical fit
Compatibility between the manufactured restorations and implant
0: incompatible
1: compatible
Measured: 1 year
occlusal contact
Restoration occlusal contact with the opposite teeth.
I.Occlusal Contacts:
- Perfect: No need for occlusal contact adjustment,
- Acceptable: Minor occlusal contact adjustment is needed,
- Correction needed: Major occlusal contact adjustment is needed.
Measured: 1 year
interface contact
Restoration interface contacts with the adjacent teeth.
II. Interface Contacts:
- Perfect: The floss is inserted into the interdental space only under pressure,
- Acceptable (1): The contact is slightly tight but the floss is placed under pressure,
- Acceptable (2): The contact is slightly weak, the floss is placed in one stroke without applying pressure,
- Correction required: Contact is poor and 100 μm metal sheet passes easily.
Measured: 1 year
Analytical measurement of 3D implant positions
Analytical outcomes were obtained from scan bodies using reverse engineering software used to calculate 3D implant positions.
Measured: 1 year
Secondary outcomes (1)
Visual analog scale
Patient impression was done in two clinical stages, registration and restoration delivery, and a scale of five points from 0 to 100 was used. A value of 0 is set to be straightforward and 100 complex. During the registration phase, the patient's anxiety level about the direct digitalization procedure, which was explained in detail before registration, was determined. After the registration, it was asked to evaluate the difficulty of the process. The time spent for adjustment during the restoration delivery phase and the comfort feeling of the restoration after adjustment were evaluated.
Measured: 1 year
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted30 Mar 2023
- Study start11 Aug 2020
- Primary completion11 Dec 2021
- Study completion11 Jun 2022
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Publications (2)Papers the sponsor has linked to this study.
- Other trials for Prosthesis UserStudies of the same condition, open and under way.
- More trials run by Hacettepe UniversityThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Enrolment
- 25 participants (actual)
Sponsor and investigators
- Lead sponsor
- Hacettepe University
- Sponsor type
- University, hospital or other
- Responsible party
- Principal investigator, Kıvanç Akça, Hacettepe University
- Investigators
- Fatmanur Demir, DDS, Principal investigator, Hacettepe University Faculty of Dentistry Department of Prosthodontics Ankara, Turkey
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT05790148
- Sponsor's protocol ID
- KA-19091
- Status last verified
- Mar 2023
- First submitted
- 19 Dec 2022
- Last updated
- 30 Mar 2023
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- No
Publications
Oh KC, Park JM, Moon HS. Effects of Scanning Strategy and Scanner Type on the Accuracy of Intraoral Scans: A New Approach for Assessing the Accuracy of Scanned Data. J Prosthodont. 2020 Jul;29(6):518-523. doi: 10.1111/jopr.13158. Epub 2020 Jun 26.
PubMed 32133690Passos L, Meiga S, Brigagao V, Street A. Impact of different scanning strategies on the accuracy of two current intraoral scanning systems in complete-arch impressions: an in vitro study. Int J Comput Dent. 2019;22(4):307-319.
PubMed 31840139
Study at a glance
From the registry record, last updated by the sponsor on 30 Mar 2023. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Precision of Different Scanbodies Used for Direct Digital Impression in Fabrication of Implant Supported Fixed Prosthesis: A Methodologic Clinical Study
- ClinicalTrials.gov ID
- NCT05790148
- Acronym / sponsor ID
- KA-19091
- Conditions
- Prosthesis User, Digitalism
- Keywords
- digital dentistry, intraoral scanner, implant scanbody
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 25 participants (actual)
- Lead sponsor
- Hacettepe UniversityUniversity, hospital or other
- Study start
- 11 Aug 2020 (actual)
- Primary completion
- 11 Dec 2021 (actual)
- Study completion
- 11 Jun 2022 (actual)
- First posted
- 30 Mar 2023 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
The goal of this clinical trials to evaluate precision of different scanbodies in same participant group. The main guestion it aim to answer is:
- Are the precision of the three different scanbodies used in direct digitalization the same for the produce of implant-supported prostheses?
Participants are healty and have short edentulous span in posterior region that will receive implant-supported prostheses.
Detailed description
Twenty-five patients receiving two implant supported restorations in treatment of short-span partial edentulism were enrolled into the study. Three different scanbodies, original, non-original and generic, were employed for direct digitalization technique. Full contour PMMA restorations were CAD/CAM fabricated from each digital record, and were evaluated in terms of implant fit, axial- and occlusal-contact. Additionally, patient's impressions for digitalization and delivery procedures were recorded using a visual analog scale. Scanbody scan recordings were subjected to reverse engineering for analytical evaluation of 3D virtual implant positioning.
Study design
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
| Arm | Type | Receives |
|---|---|---|
| Evaluation precision of different scan-bodies | Other | Device: 3ShapeThree different brand scanbodies (Straumann, Medentika, 3Shape) that applied in same participant group with randomization are used in this clinical study. These three different scan bodies are digitized using an intraoral scanner. Three different temporary restorations are designed in the CAD program and three different bridges are produced with the milling technique using the temporary restoration block. Clinical and analytic evaluations were perform and primarly, seconderly outcomes were achieved. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (6 listed)
- Be willing to voluntarily participate in the study after reading the informed consent form.
- Adult patient over 18 years of age who has completed growth and development
- Partial edentulism in the functional region for a two-implant-supported restoration with two or three occlusal members
- Having a fixed dentition in the opposing arch
- The occlusal relationship between the jaws does not require vertical and horizontal prosthetic treatment.
Key exclusion criteria (4 listed)
- Not voluntarily agreeing to participate in the study after reading the informed consent form
- Having one or more of the conditions for which implant treatment is strictly contraindicated (patients who have received radiation therapy, bone cancer, metabolic disorders)
- Having systemic (steroid therapy, uncontrolled diabetes, immunological disorders, pregnancy) risk factors for implant treatment
- Having local (periodontal discomfort, bruxism, poor oral hygiene) risk factors for implant treatment
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| 3ShapeAlso: Straumann (CARES Mono Scanbody; Straumann Holding AG), Medentika (Scanbody 2.generation; MEDENTIKA GmbH, Hügelsheim, Germany) , 3Shape (3Shape A/S, Copenhagen, Denmark)original (Straumann), non-original (Medentika) and generic scan-bodies (3Shape) were utilized for direct digitalization using intraoral scanner with image stitching algorithm. Full contour temporary restorations were fabricated from each digital record, and were evaluated in terms of clinical and analytical. | Device | Evaluation precision of different scan-bodies |
Primary outcome
Clinical fit
Time frame: 1 year
Compatibility between the manufactured restorations and implant 0: incompatible 1: compatible
occlusal contact
Time frame: 1 year
Restoration occlusal contact with the opposite teeth. I.Occlusal Contacts: 1. Perfect: No need for occlusal contact adjustment, 2. Acceptable: Minor occlusal contact adjustment is needed, 3. Correction needed: Major occlusal contact adjustment is needed.
interface contact
Time frame: 1 year
Restoration interface contacts with the adjacent teeth. II. Interface Contacts: 1. Perfect: The floss is inserted into the interdental space only under pressure, 2. Acceptable (1): The contact is slightly tight but the floss is placed under pressure, 3. Acceptable (2): The contact is slightly weak, the floss is placed in one stroke without applying pressure, 4. Correction required: Contact is poor and 100 μm metal sheet passes easily.
Analytical measurement of 3D implant positions
Time frame: 1 year
Analytical outcomes were obtained from scan bodies using reverse engineering software used to calculate 3D implant positions.
1 secondary outcome
Visual analog scale
Time frame: 1 year
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 30 Mar 2023.
- Results publication: PubMed 32133690Oh KC, Park JM, Moon HS. Effects of Scanning Strategy and Scanner Type on the Accuracy of Intraoral Scans: A New Approach for Assessing the Accuracy of Scanned Data. J Prosthodont. 2020 Jul;29(6):518-523. doi: 10.1111/jopr.13158. Epub 2020 Jun 26.
- Results publication: PubMed 31840139Passos L, Meiga S, Brigagao V, Street A. Impact of different scanning strategies on the accuracy of two current intraoral scanning systems in complete-arch impressions: an in vitro study. Int J Comput Dent. 2019;22(4):307-319.
- Individual participant dataSharing planned: No
Related trials for Prosthesis User
Recruiting
Impact of Footwear on Gait in Unilateral Transtibial Amputees
Transtibial Amputation, Lower Limb Amputation
Recruiting
Optimize Pattern Recognition Control of Powered Upper Limb Prosthesis
Prosthesis User, Prosthesis
Active, not recruiting
Optimizing Prosthetic Prescription to Mitigate the Effects of Perspiration
Amputation, Prosthesis User
Enrolling by invitation
Prosthetic Limb Movement Feedback for Upper and Lower Extremity Amputees
Prosthesis User, Amputation
RecruitingObservational study
Evaluating the Experience of Upper Limb Prosthesis Use
Prosthesis User, Amputation
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Fatmanur Demir, DDS principal investigator
Hacettepe University Faculty of Dentistry Department of Prosthodontics Ankara, Turkey
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing 3Shape in people with Prosthesis User and Digitalism, run by Hacettepe University at 1 site in Turkey (Türkiye).
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 6 inclusion and 4 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 30 Mar 2023. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in Turkey (Türkiye). Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Clinical fit (time frame: 1 year). The study lists 4 primary outcomes in all. It is what the study was designed to measure, not a finding.
Where can I read the original study information?
On the ClinicalTrials.gov record for NCT05790148, which also lists 2 linked publications.
Does a listing mean the treatment is approved or proven to work?
No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.
How often is this information updated?
AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 30 Mar 2023; AzTrials last refreshed its copy on 2 Nov 2026.