AzTrials
AzTrials

Respiratory FailureNCT05817968

Solid State vs. Balloon Esophageal Catheter for Estimation of Pleural Pressure

A study testing intelligent Esophageal Pressure Catheter (iEPC) in people with Respiratory Failure and Mechanical Ventilation, run by Erasmus Medical Center at 1 site in Netherlands.

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

Measurements of esophageal pressure (Pes) as surrogate for pleural pressure are routinely performed in selected ICU patients to facilitate lung-protective ventilation and assess breathing effort. Pes is clinically measured via a nasogastric esophageal catheter. Read more about this study

Who is it for?
Ages 18 years and older
Conditions the study is for
Respiratory Failure, Mechanical Ventilation
What is being tested?
intelligent Esophageal Pressure Catheter (iEPC)
Type of treatment
Medical device
Could I receive a placebo?
No, everyone receives an active treatment
How many people
16 participants
Where
1 siteNetherlands
Study dates
20 Oct 2023to 21 Mar 2024
Phase
Interventional
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • No healthy volunteers
  • Adult, Older adult

Who may be able to join

  • Signed informed consent
  • Patient requiring mechanical ventilation at the ICU following cardiothoracic or abdominal surgery
  • Age ≥ 18 year

Who cannot join

  • Pregnancy
  • Upper airway/esophageal/mouth or face pathology (i.e. recent surgery, esophageal varices, diaphragmatic hernia)
  • Nasal bleeding within the last <2 weeks
  • Presence of pneumothorax
  • Use of anticoagulants that increase the risk of catheter insertion

Trial locations and contacts

1 site in 1 country.

Netherlands1 site
  • Erasmus MC

    Rotterdam, South Holland, 3015GD

Other trials in Netherlands

About this study

Official title: Comparison of a Solid State Versus Balloon Esophageal Catheter for Estimation of Pleural Pressure in Surgical ICU Patients

Measurements of esophageal pressure (Pes) as surrogate for pleural pressure are routinely performed in selected ICU patients to facilitate lung-protective ventilation and assess breathing effort. Pes is clinically measured via a nasogastric esophageal catheter. Current techniques involve balloon catheters but have some important disadvantages as they could deflate over time and require a very precise positioning and filling volume. A solid-state sensor does not have disadvantages associated with balloon catheters and may therefore be a useful alternative in clinical practice.

This method-comparison study in adult mechanically ventilated ICU patients evaluates the accuracy of Pes measured using an esophageal catheter with a solid-state sensor as compared to a balloon catheter as reference standard.

Read the detailed description

Measurements of esophageal pressure (Pes) as surrogate for pleural pressure are routinely performed in selected ICU patients to facilitate lung-protective ventilation and assess breathing effort. Pes is clinically measured via a nasogastric esophageal catheter. Current techniques involve balloon catheters but have some important disadvantages as they could deflate over time and require a very precise positioning and filling volume. A solid state sensor does not have disadvantages associated with balloon catheters and may therefore be a useful alternative in clinical practice.

This method-comparison study in adult mechanically ventilated ICU patients evaluates the accuracy of Pes measured using an esophageal catheter with a solid-state sensor as compared to a balloon catheter as reference standard.

Subjects will receive a standard balloon esophageal catheter and a solid-state pressure catheter for simultaneous measurements of Pes. Study population will be post-surgical ICU patients. Measurements will be performed during clinical mechanical ventilation settings which include a first phase of passive controlled ventilation (patient is still sedated after surgery) as well a phase of partially-assisted ventilation where the patient's breathing effort has resumed and is assisted by the ventilator. During both phases, 10-15 minutes of tidal breathing will be recorded.

Being tested
intelligent Esophageal Pressure Catheter (iEPC)
Keywords
Esophageal manometry, Respiratory monitoring, Mechanical ventilation, Pleural pressure
Medical subject headings
Respiratory Insufficiency

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • intelligent Esophageal Pressure Catheter (iEPC)Device

    Also called Solid state esophageal pressure catheter, PulmoTech B.V.

    Placement of the iEPC nasogastric catheter with solid state sensor for esophageal manometry.

    Comparator: Esophageal balloon catheter (NutriVent).

Study groups in NCT05817968
Study groupRoleWhat they receive
Esophageal manometry using a solid state sensor vs. balloon catheterExperimentalPlacement of both a solid state and balloon esophageal pressure (Pes) catheter. Pes recordings of these catheters will be acquired simultaneously during both controlled mechanical ventilation and assisted mechanical ventilation, for 10-15 minutes per phase. Ventilator settings/protocol will be as per standard-of-care.
Receives: Device: intelligent Esophageal Pressure Catheter (iEPC)

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Difference in absolute Pes-derived parameters obtained by solid state catheter vs. balloon catheter.

    Absolute Pes value (in cmH2O) at end-expiration and at peak inspiration (based on flow recordings) will be recorded.

    Measured: 30 minutes

  2. Difference in relative Pes-derived parameters obtained by solid state catheter vs. balloon catheter.

    Relative Pes value (cmH2O) will be measured as the inspiratory amplitude in Pes.

    Measured: 30 minutes

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted18 Apr 2023
  2. Study start20 Oct 2023
  3. Primary completion21 Mar 2024
  4. Study completion21 Mar 2024

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Interventional
Phase
Phase N/A
Primary purpose
Other
Allocation
Not applicable
Intervention model
Single group
Model description
Method comparison study; participants serve as their own control
Masking
None (open label)
Enrolment
16 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT05817968
Sponsor's protocol ID
MEC-2023-0119
Status last verified
May 2024
First submitted
3 Apr 2023
Last updated
2 May 2024
Results posted
No
Data monitoring committee
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Publications

  • van Oosten JP, Goedendorp N, Mousa A, Flink RC, Schaart R, Flinsenberg M, Somhorst P, Gommers DAMPJ, Heunks L, Jonkman AH. Solid-state esophageal pressure sensor for the estimation of pleural pressure: a bench and first-in-human validation study. Crit Care. 2025 Jan 27;29(1):47. doi: 10.1186/s13054-025-05279-w.

    PubMed 39871347

Questions about this trial

What is this clinical trial studying?

A study testing intelligent Esophageal Pressure Catheter (iEPC) in people with Respiratory Failure and Mechanical Ventilation, run by Erasmus Medical Center at 1 site in Netherlands.

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 3 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 2 May 2024. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Netherlands. Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Difference in absolute Pes-derived parameters obtained by solid state catheter vs. balloon catheter. (time frame: 30 minutes). The study lists 2 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?

On the ClinicalTrials.gov record for NCT05817968, which also lists 1 linked publication.

Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 2 May 2024; AzTrials last refreshed its copy on 6 Nov 2026.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in