Complex Congenital Heart DiseaseCapMagNCT05943275
Magnetic Sensor Validation of Hemodynamic Non-invasive Measurements Pressure During Cardiac Catheterization
A study testing Magnetic sensor in people with Complex Congenital Heart Disease and Chronic Right Heart Failure, run by University Hospital, Montpellier at 1 site in France.
Trial summary
Follow-up of patients with complex congenital heart disease (CHD) usually involves ultrasound imaging or even MRI or CT scans of the heart and stress testing. But these examinations can be challenged in terms of their sensitivity. Read more about this study
- Who is it for?
- Ages 18 years and older
- Conditions the study is for
- Complex Congenital Heart Disease, Chronic Right Heart Failure
- What is being tested?
- Magnetic sensor
- Type of treatment
- Medical device
- Could I receive a placebo?
- No, everyone receives an active treatment
- How many people
- 10 participants
- Where
- 1 siteFrance
- Study dates
- 13 Sep 2023to 14 Aug 2025
- Phase
- Interventional
- Are there results?
- None posted in the registry
Key requirements
Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.
- Ages 18 years and older
- All sexes
- No healthy volunteers
- Adult, Older adult
Who may be able to join
- Patient who receives a right-sided catheterization
- Age ≥ 18 years
- Informed consent
Who cannot join
- Patient with a metal implant near the area of use of the device
- Pregnant or breastfeeding woman
- Patient unwilling or unable to sign consent: patient under guardianship or conservatorship, mentally retarded, dementia, language barrier
- Patient not affiliated to a social security system
- Patient under court protection
Trial locations and contacts
1 site in 1 country.
France1 site
CHU de Montpellier Département de Cardiologie Hôpital Arnaud de Villeneuve
Montpellier, 34090
About this study
Official title: Validation of a Magnetic Sensor for the Non-invasive Measurement of Jugular Venous and Radial Arterial Pressure in Patients During Cardiac Catheterization
Follow-up of patients with complex congenital heart disease (CHD) usually involves ultrasound imaging or even MRI or CT scans of the heart and stress testing. But these examinations can be challenged in terms of their sensitivity. Thus, the development of non-invasive jugular venous and radial arterial pressure sensors, reflecting the hemodynamic function of the right heart, would be very useful to the clinician responsible for early detection of a deficit in right ventricular function.
Read the detailed description
Among the 1% of live births with congenital heart disease, 20% have complex congenital heart disease (CHD). Their life expectancy, initially low, is constantly improving due to diagnostic, follow-up and therapeutic advances, particularly surgical. The pediatric population surviving the neonatal period is increasingly high and the number of people reaching adulthood has even exceeded the pediatric population for the last 3 years, a number that puts adult cardiologists in difficulty as they have little knowledge of the natural history of these pathologies. Indeed, it is difficult to predict or diagnose early decompensation or deterioration of cardiac function, especially for those affecting right heart function, because the anatomic and hemodynamic particularities of these CHDs make the usual functional exploration parameters not very sensitive. Indeed, the dysfunction of ventricular function is progressive and these patients remain asymptomatic for a long time and then decompensate suddenly. The late symptoms and the anatomic difficulty in adapting paraclinical criteria used for morphologically normal hearts explain their difficult interpretation and a delay in management. The current evaluation of these CHDscombining ultrasound imaging or even MRI or cardiac CT and stress testing is often flawed in terms of their sensitivity, because of the anatomic geometric complexity of these heart diseases.
Thus, the development of a non-invasive jugular venous pressure sensor, reflecting the hemodynamic function of the right heart, would be very useful to the clinician responsible for the follow-up of subjects with CHD, in order to detect early a deficit in right ventricular function.
- Terki and H. Tran of the DynaCar team "Dynamics of cardiac couplings" of the Laboratory of Physiology Experimental Medicine (PhyMedExp), have developed an innovative medical detection device in partnership with the Laboratory of Coordination Chemistry LCC of the CNRS of Toulouse (A. Bousseksou) and the company eV-technologies (S. Wane and H. Tran), allowing to measure this jugular venous pressure by simple apposition of this one on the vein. A small magnet of 1cm X 1cm is placed beside the sensor. The very weak magnetic field of this magnet (0,02 Tesla) will generate a voltage at the terminals of the micro-sensor placed just beside. This voltage will reflect the pressure force related to the blood flow circulating in the cardiovascular network and give information on the heartbeat by magnetic measurements. The magnet and the micro-sensor are encapsulated in a plastic support of 3cm X1 cm and clipped on a flexible bracelet that can be affixed to the neck.
The magnetic field of the magnet used is of the order of magnitude of that of the fridge magnets (0.02 Tesla). It is therefore not harmful. It is 75 times weaker than that used in MRI (1.5T).
This device does not require the use of contrast agents, no patch and no adhesive product and is without direct contact with the skin.
The signals detected by the microchip (microsensor) are then transmitted to a tablet or laptop computer via a wired USB connection. A second sensor will be positioned on the radial artery through a bracelet placed around the wrist. Thus a magnetic arterial measurement will be simultaneously recorded.
It is therefore proposed that this magnetic sensor, affixed to the jugular vein, which empties into the right atrium, has the same sensitivity as the bloody measurement of central venous pressure. For that purpose, in a first study, the research team want to compare, during a right catheterization, the blood venous pressure curve, which is the reference method, with the one obtained by the innovative magnetic sensor. Indeed, before evaluating the interest of this medical device on patients with a dysfunction of the cardiac pump, the sensitivity of the measurements obtained in subjects who will benefit from an invasive hemodynamic evaluation during their follow-up must be validated, which will allow us to obtain a reference measurement.
The technology proposed in this study is totally innovative. It is based on the measurement of the magnetic field generated by the blood fluid during its passage in a vessel, which is detected by a micro-sensor placed on the skin. Although the structure and measurement principle are completely innovative for this study, magnetic ultrasensitivity has been demonstrated. Validation of the sensitivity of these sensors to non-invasively detect variations in venous pressure at the jugular vein will allow the future development of non-invasive miniature 'smart devices' with very low energy consumption (80 microWatt) and high early prognostic value in relation to right heart failure, allowing the refinement of monitoring and re-evaluation of therapeutic management of patients with CHD. These devices will be developed, characterized, tested and deployed in Occitania. The synergy between academic (University of Montpellier, CNRS Toulouse, INSERM, CHUM) and industrial (eV-Technologies) actors will ensure that the entire value chain from the development of the microsensors to the acceleration of their valorization and technology transfer will be anchored in Occitanie.
- Being tested
- Magnetic sensor
- Keywords
- Non-invasive venous pressure measurement
What participants receive
What participants receive. In a randomised study each person is assigned to one group by chance.
Magnetic sensorDevice
During the right heart catheterization procedure, measurement of hemodynamic pressures by the non-invasive experimental method (Magnetic sensor) and the invasive control method
| Study group | Role | What they receive |
|---|---|---|
| Patient with an indication for right heart catheterization | Other | During the preparation of the subject on the cardiac catheterization table, a person specifically trained to the measurements of the medical device under test will be dedicated to this study. Once the skin has been cleaned with alcohol the device (magnet and micro-sensor encapsulated in the plastic support) will be placed on the subject's uninjured skin of the subject, on the path of the jugular vein. A second device will be placed at the level of the radial artery radial artery with the help of a bracelet. The signals will be recorded and observed on a screen for the duration of the invasive hemodynamic measurements, i.e. approximately 15 minutes. Receives: Device: Magnetic sensor |
What is being measured
The primary outcome is the main question the study is designed to answer.
Estimate the concordance between the mean peak atrial pressure values measured by the two methods (invasive and magnetic sensor) over a 15-minute period.
Average value of the atrial peak pressure measured by both methods (invasive and magnetic sensor) over a 15-minute period.
Measured: Baseline
Secondary outcomes (5)
Assess whether there is an overlap between the jugular venous pressure curve obtained with a magnetic sensor and the invasive central venous pressure curve
Concordance test between the average of the parameters describing the two pressure curves measured with the two methods (invasive and magnetic sensor) over a period of 15 minutes.
Value of the peak pressure for the ventricular contraction (c wave)
Measured: baseline
Assess whether there is an overlap between the jugular venous pressure curve obtained with a magnetic sensor and the invasive central venous pressure curve (atrial filling)
Concordance test between the average of the parameters describing the two pressure curves measured with the two methods (invasive and magnetic sensor) over a period of 15 minutes.
Value of the peak pressure for the atrial filling (v wave)
Measured: baseline
Assess whether there is an overlap between the jugular venous pressure curve obtained with a magnetic sensor and the invasive central venous pressure curve (Area under the pressure curve during a cardiac revolution)
Concordance test between the average of the parameters describing the two pressure curves measured with the two methods (invasive and magnetic sensor) over a period of 15 minutes.
Value of the peak pressure for the Area under the pressure curve during a cardiac revolution.
Measured: baseline
Evaluate whether there is an overlap, during a simultaneous measurement, between the jugular venous pressure curve and the radial arterial pressure curve obtained with a magnetic and the radial arterial pressure curve obtained with a magnetic sensor
visual identification of two pressure peaks with the presence of a cataclysmic incisure between systole and diastole on the blood pressure curve measured at the radial artery with the magnetic sensor.
Measured: baseline
To evaluate the safety of measuring jugular venous pressure or radial arterial pressure with a magnetic sensor in patients.
Collection of undesirable effects experienced by the patient during the installation of magnetic sensors during the measurement of venous pressure.
Measured: Baseline
Timeline
From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.
- First posted13 Jul 2023
- Study start13 Sep 2023
- Primary completion14 Aug 2025
- Study completion14 Aug 2025
Resources
- Official record on ClinicalTrials.govThe registry entry this page is built from, with its full change history.
- Other trials for Complex Congenital Heart DiseaseStudies of the same condition, open and under way.
- More trials run by University Hospital, MontpellierThe sponsor's other registered studies.
- What the trial phases meanHow a treatment moves from first tests in people to approval.
More details
For doctors and researchers: how the study is designed, who runs it, and its registry IDs.
Study design
- Study type
- Interventional
- Phase
- Phase N/A
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Model description
- comparison between two measurement methods, one of which serves as a reference in a single group of patients patients, without randomization, prospective and monocentric. This is a proof-of-concept pilot study. concept.
- Masking
- None (open label)
- Enrolment
- 10 participants (actual)
Sponsor and investigators
- Lead sponsor
- University Hospital, Montpellier
- Sponsor type
- University, hospital or other
- Collaborators
- Université Montpellier
- Responsible party
- Sponsor
- Investigators
- Quentin DELBAERE, MD, Study director, CHU de Montpellier
IDs, dates and publications
- ClinicalTrials.gov ID
- NCT05943275
- Sponsor's protocol ID
- RECHMPL21_0595
- Other IDs
- 2022-A00775-38
- Acronym
- CapMag
- Status last verified
- Jun 2026
- First submitted
- 23 Jun 2023
- Last updated
- 15 Jun 2026
- Results posted
- No
- Data monitoring committee
- No
- FDA-regulated drug
- No
- FDA-regulated device
- No
- Individual data sharing
- Undecided
Study at a glance
From the registry record, last updated by the sponsor on 15 Jun 2026. Recruitment status is as the sponsor reported it: confirm with the study team.
- Official title
- Validation of a Magnetic Sensor for the Non-invasive Measurement of Jugular Venous and Radial Arterial Pressure in Patients During Cardiac Catheterization
- ClinicalTrials.gov ID
- NCT05943275
- Acronym / sponsor ID
- CapMag / RECHMPL21_0595
- Keywords
- Non-invasive venous pressure measurement
- Study type
- Interventional
- Recruitment status
- Completed
- Enrolment
- 10 participants (actual)
- Lead sponsor
- University Hospital, MontpellierUniversity, hospital or other
- Collaborators
- Université Montpellier
- Study start
- 13 Sep 2023 (actual)
- Primary completion
- 14 Aug 2025 (actual)
- Study completion
- 14 Aug 2025 (actual)
- First posted
- 13 Jul 2023 (actual)
- Results
- Not posted in the source record
Clinical summary
The research question as the sponsor registered it. This describes what the study plans to test, not what it found.
Follow-up of patients with complex congenital heart disease (CHD) usually involves ultrasound imaging or even MRI or CT scans of the heart and stress testing. But these examinations can be challenged in terms of their sensitivity. Thus, the development of non-invasive jugular venous and radial arterial pressure sensors, reflecting the hemodynamic function of the right heart, would be very useful to the clinician responsible for early detection of a deficit in right ventricular function.
Detailed description
Among the 1% of live births with congenital heart disease, 20% have complex congenital heart disease (CHD). Their life expectancy, initially low, is constantly improving due to diagnostic, follow-up and therapeutic advances, particularly surgical. The pediatric population surviving the neonatal period is increasingly high and the number of people reaching adulthood has even exceeded the pediatric population for the last 3 years, a number that puts adult cardiologists in difficulty as they have little knowledge of the natural history of these pathologies. Indeed, it is difficult to predict or diagnose early decompensation or deterioration of cardiac function, especially for those affecting right heart function, because the anatomic and hemodynamic particularities of these CHDs make the usual functional exploration parameters not very sensitive. Indeed, the dysfunction of ventricular function is progressive and these patients remain asymptomatic for a long time and then decompensate suddenly. The late symptoms and the anatomic difficulty in adapting paraclinical criteria used for morphologically normal hearts explain their difficult interpretation and a delay in management. The current evaluation of these CHDscombining ultrasound imaging or even MRI or cardiac CT and stress testing is often flawed in terms of their sensitivity, because of the anatomic geometric complexity of these heart diseases.
Thus, the development of a non-invasive jugular venous pressure sensor, reflecting the hemodynamic function of the right heart, would be very useful to the clinician responsible for the follow-up of subjects with CHD, in order to detect early a deficit in right ventricular function.
- Terki and H. Tran of the DynaCar team "Dynamics of cardiac couplings" of the Laboratory of Physiology Experimental Medicine (PhyMedExp), have developed an innovative medical detection device in partnership with the Laboratory of Coordination Chemistry LCC of the CNRS of Toulouse (A. Bousseksou) and the company eV-technologies (S. Wane and H. Tran), allowing to measure this jugular venous pressure by simple apposition of this one on the vein. A small magnet of 1cm X 1cm is placed beside the sensor. The very weak magnetic field of this magnet (0,02 Tesla) will generate a voltage at the terminals of the micro-sensor placed just beside. This voltage will reflect the pressure force related to the blood flow circulating in the cardiovascular network and give information on the heartbeat by magnetic measurements. The magnet and the micro-sensor are encapsulated in a plastic support of 3cm X1 cm and clipped on a flexible bracelet that can be affixed to the neck.
The magnetic field of the magnet used is of the order of magnitude of that of the fridge magnets (0.02 Tesla). It is therefore not harmful. It is 75 times weaker than that used in MRI (1.5T).
This device does not require the use of contrast agents, no patch and no adhesive product and is without direct contact with the skin.
The signals detected by the microchip (microsensor) are then transmitted to a tablet or laptop computer via a wired USB connection. A second sensor will be positioned on the radial artery through a bracelet placed around the wrist. Thus a magnetic arterial measurement will be simultaneously recorded.
It is therefore proposed that this magnetic sensor, affixed to the jugular vein, which empties into the right atrium, has the same sensitivity as the bloody measurement of central venous pressure. For that purpose, in a first study, the research team want to compare, during a right catheterization, the blood venous pressure curve, which is the reference method, with the one obtained by the innovative magnetic sensor. Indeed, before evaluating the interest of this medical device on patients with a dysfunction of the cardiac pump, the sensitivity of the measurements obtained in subjects who will benefit from an invasive hemodynamic evaluation during their follow-up must be validated, which will allow us to obtain a reference measurement.
The technology proposed in this study is totally innovative. It is based on the measurement of the magnetic field generated by the blood fluid during its passage in a vessel, which is detected by a micro-sensor placed on the skin. Although the structure and measurement principle are completely innovative for this study, magnetic ultrasensitivity has been demonstrated. Validation of the sensitivity of these sensors to non-invasively detect variations in venous pressure at the jugular vein will allow the future development of non-invasive miniature 'smart devices' with very low energy consumption (80 microWatt) and high early prognostic value in relation to right heart failure, allowing the refinement of monitoring and re-evaluation of therapeutic management of patients with CHD. These devices will be developed, characterized, tested and deployed in Occitania. The synergy between academic (University of Montpellier, CNRS Toulouse, INSERM, CHUM) and industrial (eV-Technologies) actors will ensure that the entire value chain from the development of the microsensors to the acceleration of their valorization and technology transfer will be anchored in Occitanie.
Study design
- Primary purpose
- Other
- Allocation
- Not applicable
- Intervention model
- Single group
- Masking
- None (open label)
- Number of arms
- 1
- Model description
- comparison between two measurement methods, one of which serves as a reference in a single group of patients patients, without randomization, prospective and monocentric. This is a proof-of-concept pilot study. concept.
| Arm | Type | Receives |
|---|---|---|
| Patient with an indication for right heart catheterization | Other | Device: Magnetic sensorDuring the preparation of the subject on the cardiac catheterization table, a person specifically trained to the measurements of the medical device under test will be dedicated to this study. Once the skin has been cleaned with alcohol the device (magnet and micro-sensor encapsulated in the plastic support) will be placed on the subject's uninjured skin of the subject, on the path of the jugular vein. A second device will be placed at the level of the radial artery radial artery with the help of a bracelet. The signals will be recorded and observed on a screen for the duration of the invasive hemodynamic measurements, i.e. approximately 15 minutes. |
Who may qualify
- Ages
- 18 years and older
- Sex
- All
- Healthy volunteers
- Not accepted
- Age groups
- Adult, Older adult
Key inclusion criteria (3 listed)
- Patient who receives a right-sided catheterization
- Age ≥ 18 years
- Informed consent
Key exclusion criteria (5 listed)
- Patient with a metal implant near the area of use of the device
- Pregnant or breastfeeding woman
- Patient unwilling or unable to sign consent: patient under guardianship or conservatorship, mentally retarded, dementia, language barrier
- Patient not affiliated to a social security system
- Patient under court protection
Eligibility is decided by the study team after screening; this overview does not establish that a patient qualifies. Full inclusion and exclusion criteria.
Interventions
| Intervention | Type | Arms |
|---|---|---|
| Magnetic sensorDuring the right heart catheterization procedure, measurement of hemodynamic pressures by the non-invasive experimental method (Magnetic sensor) and the invasive control method | Device | Patient with an indication for right heart catheterization |
Primary outcome
Estimate the concordance between the mean peak atrial pressure values measured by the two methods (invasive and magnetic sensor) over a 15-minute period.
Time frame: Baseline
Average value of the atrial peak pressure measured by both methods (invasive and magnetic sensor) over a 15-minute period.
5 secondary outcomes
Assess whether there is an overlap between the jugular venous pressure curve obtained with a magnetic sensor and the invasive central venous pressure curve
Time frame: baseline
Assess whether there is an overlap between the jugular venous pressure curve obtained with a magnetic sensor and the invasive central venous pressure curve (atrial filling)
Time frame: baseline
Assess whether there is an overlap between the jugular venous pressure curve obtained with a magnetic sensor and the invasive central venous pressure curve (Area under the pressure curve during a cardiac revolution)
Time frame: baseline
Evaluate whether there is an overlap, during a simultaneous measurement, between the jugular venous pressure curve and the radial arterial pressure curve obtained with a magnetic and the radial arterial pressure curve obtained with a magnetic sensor
Time frame: baseline
To evaluate the safety of measuring jugular venous pressure or radial arterial pressure with a magnetic sensor in patients.
Time frame: Baseline
Results and safety
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
Research links
- Official record on ClinicalTrials.govLast updated by the sponsor 15 Jun 2026.
- Individual participant dataSharing planned: Undecided
Related trials for Complex Congenital Heart Disease
RecruitingObservational study
AI-Based Differential Diagnosis and Localization of Tachycardia Using ECG: Multicenter Registry (EP-AI ASSIST)
Tachycardia, Paroxysmal Supraventricular Tachycardia
RecruitingObservational study
Rare Disease Patient Registry & Natural History Study - Coordination of Rare Diseases at Sanford
Rare Disorders, Undiagnosed Disorders
Recruiting
Executive Function Intervention for Children With Complex Congenital Heart Disease
Heart Defect, Congenital, Executive Dysfunction
Active, not recruitingObservational study
ALTERRA Post-Approval Study
Pulmonary Valve Insufficiency, Complex Congenital Heart Defect
Recruiting
COMPASSION S3 - Evaluation of the SAPIEN 3 Transcatheter Heart Valve in Patients With Pulmonary Valve Dysfunction
Complex Congenital Heart Defect, Dysfunctional RVOT Conduit
Referral and contact
AzTrials does not enrol participants or take referrals. Contact the study team or a site listed below; they decide who can take part. This study is not recruiting at the moment.
Quentin DELBAERE, MD study director
CHU de Montpellier
1 site in 1 country: see every site and its status.
Questions about this trial
What is this clinical trial studying?
A study testing Magnetic sensor in people with Complex Congenital Heart Disease and Chronic Right Heart Failure, run by University Hospital, Montpellier at 1 site in France.
The full registered description is in the About this study section and the official record.
Who may be eligible to take part?
The sponsor lists 3 inclusion and 5 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.
Is this clinical trial currently recruiting?
The record says: finished, as of the sponsor's last update on 15 Jun 2026. Status can change between updates, so confirm with the study contact before making plans.
Where is the study taking place?
The record lists 1 site in France. Whether a site is taking part right now should be confirmed with that site. See every site.
What are the possible benefits and risks?
They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.
Are results available for this study?
The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.
How can a doctor refer a patient or contact the research team?
The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.
What does the primary outcome measure?
Estimate the concordance between the mean peak atrial pressure values measured by the two methods (invasive and magnetic sensor) over a 15-minute period. (time frame: Baseline). It is what the study was designed to measure, not a finding.