AzTrials
AzTrials

Position Sense DisordersNCT06057259

Validity and Reliability of Wrist Proprioception Measurement Methods

An observational study of Position Sense Disorders and Wrist, run by Gazi University at 1 site in Turkey (Türkiye).

Completed

Finished. The study has ended and is not enrolling. Results may be posted on the official record.

Official record
Search all trials

Trial summary

The goal of this observational study is to compare the validity and reliability of three Different methods used for wrist proprioception measurement in the healthy population. The main question[s] it aims to answer are: Are the methods valid and reliable? Which method is superior? Wrist proprioception measurement of… Read more about this study

Who is it for?
Ages 18 years and olderHealthy volunteers can take part
Conditions the study is for
Position Sense Disorders, Wrist
What is being tested?
Joint position sense measurement
Type of treatment
Medical device
How many people
32 participants
Where
1 siteTurkey (Türkiye)
Study dates
2 Jul 2018to 9 Jun 2019
Phase
Observational
Are there results?
None posted in the registry

Key requirements

Who can take part, as listed by the sponsor. Only the study team can confirm whether you are eligible, so take this list to your doctor.

  • Ages 18 years and older
  • All sexes
  • Healthy volunteers accepted
  • Adult, Older adult

Study population: Healthy volunteer participants

Who may be able to join

  • After providing detailed information about the study, individuals who had agreed to participate in the research were included in the study

Who cannot join

  • individuals who suffered an injury or underwent a surgical procedure in the last six months that could affect hand functions or senses were excluded from the study.
  • Individuals with a history of neuromuscular disease, traumatic nerve injury, congenital anomalies, or skin infections were excluded.

Trial locations and contacts

1 site in 1 country.

Turkey (Türkiye)1 site
  • Barış SEVEN

    Izmir, Çiğli

Other trials in Turkey (Türkiye)

About this study

Official title: Comparison of the Validity and Reliability of Three Different Methods Used for Wrist Proprioception Measurement

The goal of this observational study is to compare the validity and reliability of three Different methods used for wrist proprioception measurement in the healthy population. The main question[s] it aims to answer are:

  • Are the methods valid and reliable?
  • Which method is superior?

Wrist proprioception measurement of the participants is performed. Researchers compared the inclinometer, goniometer, and joint position sense goniometer to determine the superior method.

Read the detailed description

Proprioception is one of the most important mechanisms involved in ensuring the optimal position of the wrist to prevent injuries. It occurs through stimuli from different structures such as muscle, tendon, joint capsule and skin and provides the perception of the joint's position and movement characteristics (direction, speed, etc.). This perception is essential for effective and safe motor performance. Previous studies have provided evidence that proprioceptive training yields improvements in somatosensory and sensorimotor function. Furthermore, a relationship between the loss of proprioception and motor function has also been demonstrated. Additionally, proprioceptive training reduces the frequency of injuries and provides a faster and more efficient rehabilitation process. Therefore, it is essential to detect proprioceptive defects as a part of patient evaluation which is only achievable by using valid and reliable assessment tools.

Proprioception encompasses both static (i.e., joint position sense (JPS)) and dynamic (i.e., kinesthesia) components of joint perception. Many tools and methods are available to evaluate these components, including universal goniometer, inclinometer, wrist goniometer, mobile applications, robot-assisted assessment, and isokinetic dynamometers. Especially, goniometer, inclinometer, and isokinetic dynamometer are widely used in evaluating proprioception. However, the number of studies on the validity and reliability of these tools is very limited for the wrist. In addition to these tools, the joint position sense goniometer (JPSG) is replicated and used by researchers due to its low cost and accessibility.

Although some studies found goniometer to have high precision in wrist trauma patients, there are still no gold standard tests or tools available for evaluating wrist proprioception. Therefore, it becomes confusing for researchers and clinicians to decide which method should be used in their practice accurately. In line with all these data, the present study aimed to examine the validity and test-retest reliability of two frequently used methods (Goniometer and Inclinometer) and JPSG in wrist proprioception assessment.

The detailed information about the measurements is provided in the "Study Protocol" file.

Being tested
Joint position sense measurement
Keywords
joint, hand, sensation, Therapy, Occupational
Medical subject headings
Somatosensory Disorders

What participants receive

What participants receive. In a randomised study each person is assigned to one group by chance.

  • Joint position sense measurementDevice

    The participants' wrist joint position sense was evaluated.

Study groups in NCT06057259
Study groupRoleWhat they receive
InclinometerMeasuring Wrist Joint Position Sense with a Inclinometer
Receives: Device: Joint position sense measurement
GoniometerMeasuring Wrist Joint Position Sense with a Goniometer
Receives: Device: Joint position sense measurement
Joint position sense goniometerMeasuring Wrist Joint Position Sense with a joint position sense goniometer
Receives: Device: Joint position sense measurement

What is being measured

The primary outcome is the main question the study is designed to answer.

  1. Active joint position sense measurement with the Goniometer

    The goniometric (1° scale increments) measurement was performed with the elbow positioned at 90° flexion and resting on the table, the forearm was in mid-pronation, and the fingers were relaxed. The movement axis of the mid-carpal and radiocarpal joints is defined as the pivot point of the goniometer to ensure a compatible measurement of wrist movement. The stable arm of the goniometer was placed parallel to the radius, and the mobile arm followed the third metacarpal bone.

    Measured: through study completion, an average of 1 year

  2. Active joint position sense measurement with the Joint Position Sense Goniometer

    The JPSG consists of two wooden boards fixed at an angle of 90°. The plate perpendicular to the ground has an opening that the wrist can go through. 0 to 180° angle values with 1° increments were drawn on the plate that parallels the floor. For the evaluation, the participant was asked to sit in front of the table with the trunk upright and the shoulder in the neutral position. The patient's forearm passed through the opening in the JPSG, and the wrist joint was adjusted to match the axis of movement. The forearm was positioned in mid-pronation, the wrist was positioned at 0° flexion/extension, and the forearm was in the neutral position. Participants were asked not to contact the plates during the measurements.

    Measured: through study completion, an average of 1 year

  3. Active joint position sense measurement with the Inclinometer

    Another tool used to evaluate wrist active joint position sense was the digital dual inclinometer. The limb position used during the inclinometer evaluations was the same as the position for the goniometer. One of the inclinometer sensors was placed on the 3rd metacarpal bone on the dorsal side of the hand. The other sensor was placed on the dorsal side of the forearm, perpendicular to the flexion/extension movement axis.

    Measured: through study completion, an average of 1 year

Secondary outcomes (1)
  1. Active joint position sense measurement with the Cybex Isokinetic Dynamometer

    The Cybex isokinetic dynamometer was used as a reference standard to test the validity of the methods. The evaluation of proprioception using the isokinetic dynamometer was performed with the participants in sitting. The shoulder was positioned in the midline, the elbow was flexed about 90°, and the wrist was positioned in supination. During the evaluation, the forearm was fixed with a strap to prevent the forearm from moving and changing the angle of the wrist. The rotation axis of the dynamometer was aligned with the diagonal axis of the distal tubercule of radius and the head of ulna. The wrist was placed in a 0° position. In this starting position, the range of motion was set as 40° flexion and 40°extension. The device was calibrated before the evaluation of each participant.

    Measured: through study completion, an average of 1 year

Timeline

From the start of the study to its completion; the mark is today. Estimated dates are the sponsor’s plan.

  1. First posted28 Sep 2023
  2. Study start2 Jul 2018
  3. Primary completion12 Apr 2019
  4. Study completion9 Jun 2019

Resources

More details

For doctors and researchers: how the study is designed, who runs it, and its registry IDs.

Study design
Study type
Observational
Observational model
Cohort
Time perspective
Prospective
Enrolment
32 participants (actual)
IDs, dates and publications
ClinicalTrials.gov ID
NCT06057259
Sponsor's protocol ID
3
Status last verified
Sep 2023
First submitted
6 Sep 2023
Last updated
28 Sep 2023
Results posted
No
FDA-regulated drug
No
FDA-regulated device
No
Individual data sharing
No

Questions about this trial

What is this clinical trial studying?

An observational study of Position Sense Disorders and Wrist, run by Gazi University at 1 site in Turkey (Türkiye).

The full registered description is in the About this study section and the official record.

Who may be eligible to take part?

The sponsor lists 1 inclusion and 2 exclusion criteria. Eligibility is decided by the study team after screening, so read the full criteria and contact a listed site.

Is this clinical trial currently recruiting?

The record says: finished, as of the sponsor's last update on 28 Sep 2023. Status can change between updates, so confirm with the study contact before making plans.

Where is the study taking place?

The record lists 1 site in Turkey (Türkiye). Whether a site is taking part right now should be confirmed with that site. See every site.

What are the possible benefits and risks?

They depend on the study and the treatment, and no study can promise a benefit. The study team explains the known risks during informed consent, before anyone joins; the record itself does not list them.

Are results available for this study?

The study is completed, but results are not available in the source record. That does not mean the treatment did or did not work.

How can a doctor refer a patient or contact the research team?

The record lists no contact. The official record names the sponsor, who can be asked directly. AzTrials does not enrol participants or take referrals.

What does the primary outcome measure?

Active joint position sense measurement with the Goniometer (time frame: through study completion, an average of 1 year). The study lists 3 primary outcomes in all. It is what the study was designed to measure, not a finding.

Where can I read the original study information?
Does a listing mean the treatment is approved or proven to work?

No. A listing means the study is registered. It does not show that the treatment is safe, works, or is approved by a regulator.

How often is this information updated?

AzTrials copies changed records from ClinicalTrials.gov every night and reloads the whole registry every week. The sponsor last updated this record on 28 Sep 2023.

Free account

Log in to keep searching

You’ve used your 3 free searches. AzTrials is free: log in or create a free account to keep searching clinical trials and save the ones you want to follow.

Create a free accountLog in